• Title/Summary/Keyword: gingival line

Search Result 46, Processing Time 0.018 seconds

MARGINAL FIDELITY ACCORDING TO THE MARGIN TYPES OF ALL CERAMIC CROWNS (전부도재관의 변연형태에 따른 변연적합도에 관한 연구)

  • Koo, Jae-Yong;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.445-457
    • /
    • 1997
  • Poor marginal fidelity resulting in a large marginal gap increases plaque accumulation, gingival inflammation and dental caries. The purpose of this study was to evaluate the marginal fit of three different cervical finishing methods of prepared teeth. A stereomicroscope was used to measure the space between the margin of restoration and the finishing line of prepared tooth. The results were statistically analyzed using the ANOVA and Multiple Range Test(Tukey's HSD). The results were as follows : 1. There were no significant differences concerning the types of tooth and positon (P>0.05), whereas the differences were statistically significant in case of cervical finishing methods (P<0.05). 2. There were statistically significant differences between before and after cementation (P<0.05). 3. In comparison according to variable margins after cementation, the gap discrepancies were increased in $130^{\circ}$ shoulder margin, chamfer margin and $90^{\circ}$ shoulder margin in ascending order, and there were significant differences between $90^{\circ}$ shoulder margin and chamfer, $130^{\circ}$ shoulder margin 4. In comparison according to variable margins, the gap discrepancies were increased in chamfer margin, $130^{\circ}$ shoulder margin and $90^{\circ}$ shoulder margin in ascending order, and there were significant differences between $90^{\circ}$ shoulder margin and chamfer, $130^{\circ}$ shoulder margin. 5. This study demonstrated a better marginal fit with all-ceramic crowns fabricated on chamfer and $130^{\circ}$ shoulder margin compared with $90^{\circ}$ shoulder margin.

  • PDF

Mechanism underlying Chios gum mastic-induced apoptosis on SCC25 human tongue squamous cell carcinoma cell line

  • Lee, Seung-Eun;Hur, Young-Joo;Kim, In-Ryoung;Kwak, Hyun-Ho;Kim, Gyoo-Cheon;Shin, Sang-Hun;Kim, Chul-Hoon;Park, Bong-Soo
    • International Journal of Oral Biology
    • /
    • v.34 no.2
    • /
    • pp.61-72
    • /
    • 2009
  • Chios gum mastic (CGM) is a resin produced from the stem and leaves of Pistiacia lentiscus L var chia, a plant which grows only on Chios Island in Greece. CGM has been used for many centuries as a dietary supplement and folk medicine for stomach and duodenal ulcers in many Mediterranean countries and is known also to induce cell cycle arrest and apoptosis in some cancer cells. In this study, we further investigated the induction and mechanisms underlying the apoptotic response to CGM treatment in the SCC25 human tongue squamous cell carcinoma cell line. The viability of SCC25 cells, human normal keratinocytes (HaCaT cells) and human gingival fibroblasts (HGF-1 cells), and the growth inhibition of SCC25 cells were assessed by MTT assay and clonogenic assay, respectively. Staining with Hoechst and hemacolor dyes and TUNEL assays were employed to detect SCC25 cells undergoing apoptosis. SCC25 cells were treated with CGM, and this was followed by western blotting, immunocytochemistry, confocal microscopy, FACScan flow cytometry, MMP activity and proteasome activity analyses. CGM treatment of SCC25 cells was found to result in a time- and dosedependent decrease in cell viability, a dose-dependent inhibition of cell growth, and apoptotic cell death. Interestingly, CGM showed a remarkable level of cytotoxicity in SCC25 cells but not in normal cells. Tested SCC25 cells also showed several lines of apoptotic manifestation. Taken together, our present findings demonstrate that CGM strongly inhibits cell proliferation by modulating the expression of G1 cell cycle-related proteins and induces apoptosis via the proteasome, mitochondria and caspase cascades in SCC25 cells.

Longitudinal Study of the Subgingival Microbial Change after Tetracycline Topical Application (Tetracycline 국소도포가 치은연하 세균분포에 미치는 영향)

  • Choi, Kwang-Choon;Lee, Young-Hee;Lee, Jin-Yong;Chung, Chong-Pyoung;Son, Seong-Heui
    • The Journal of the Korean Society for Microbiology
    • /
    • v.21 no.4
    • /
    • pp.503-513
    • /
    • 1986
  • Previous studies have developed the technique of topical application of tetracycline(TC) into the periodontal pockets and examined the change of clinical parameters and subgingival microbial morphotypes. The purpose of this study was to longitudinally examine the clinical and microbiological effects of topically applied TC in a double-blind and split-mouth design. Thirteen patients with moderate periodontitis, who were treated with or without TC application and scaling treatment, were examined. TC gel(3%) was used to apply into the selected periodontal pockets twice a week for 2 weeks. During the experiment, clinical parameters and subgingival microbial morphotypes were examined, and for isolation of black-pigmented Bacteroides(BPB) and streptococci, an anaerobic sample culturing was done at week 0, 2, and 7. In clinical observation the TC-scaled group exhibited a significant decrease of Gingival Inflammatory Index, Plaque Index, Sulcus Bleeding Index, pocket depth, and gingival crevicular fluid when compared to the TC-unsealed, placebo-scaled, and placebo-unsealed groups. The result of microbial morphotype observation showed a significant increase of coccal form and a decrease of spirochetes in the TC-scaled, TC-unscaled, and placebo-scaled groups. The culture study of streptococci revealed that TC with scaling treatment resulted in a significant increase of S. sanguis I at week 2, but its proportion had returned to the base line level. The anaerobic culture study showed that BPB was significantly reduced in the TC-scaled and TC-unsealed groups at week 7. Among BPB species, B. intermedius declined significantly with time treatment(week 2 and 7) in the TC-scaled and TC-unsealed groups. These results suggest that the settled pathogenic microflora can be succeeded by nonpathogenic microflora in periodontal pockets after TC treatment.

  • PDF

Immediate implant placement into extraction sites with periapical lesions in the esthetic zone: a case report (치근단 병소를 가진 치아의 발치 후 즉시 임플란트 식립 및 보철을 통한 심미성 회복)

  • Yi, Jae-Young;Kim, Jee-Hwan;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.191-197
    • /
    • 2012
  • Esthetics is important in restoring maxillary anterior area. Alveolar bone resorption and loss of interdental papilla may be minimized by immediate implantation. Previous studies showed successful results with the immediate implantation in healthy extraction socket, while many of these studies objected the immediate implantation into extraction sites with periapical lesions. Recent studies, however, reported successful results of the immediate implantation into extraction sites with periapical lesions with careful debridement of extraction sockets and general medication of antibiotics prior to implantation. A 73-year-old female visited the department of Prosthodontics in ${\bigcirc}{\bigcirc}$ University Dental Hospital with the chief complaint of fallen post-core and crown on left maxillary incisor. Although the incisor was with vertical root fracture and periapical lesion, the immediate implantation following the extraction of tooth was planned. Thorough socket debridement, irrigation with chlorhexidine, and tetracycline soaking were followed by immediate implantation. The general medication of antibiotics (Moxicle Tab.$^{(R)}$, 375 mg) was prescribed before and after the surgery. Immediate provisional restoration was delivered two days after the surgery, and the definitive metal-ceramic restoration was placed about six months later after reproducing the emergence profile from the provisional restoration. This case presents satisfying result esthetically and functionally upto two years after the placement of prosthesis with the harmonious gingival line and no loss of marginal bone.

Dental application of glass-ceramic materials for aesthetic restoration (심미수복을 위한 글라스-세라믹 재료의 치과 응용)

  • Bae, Tae Sung
    • The Journal of the Korean dental association
    • /
    • v.58 no.7
    • /
    • pp.435-442
    • /
    • 2020
  • Porcelain is the first ceramic material to be introduced into dentistry. Porcelain jacket crown was introduced by Dr. Charles H Land in 1886, which was an excellent aesthetic dental restoration but has not been widely used due to high firing shrinkage and low tensile strength. Then metal-ceramic system, which combines the esthetic properties of ceramics and the mechanical properties of metals, was introduced and nowadays it is still used in dental clinical field. However, the metal-ceramic system has shown some problems, such as increased lightness by reflection of light at opaque layer, shadow beneath the gingival line due to the block-out of light by metal coping, exposure of metal in margin part, bond failure between metal and porcelain, oxidation of metal coping during firing the porcelain, etc. Recently, along with the advance of fabrication methods of dental ceramics, the all-ceramic restorations with high esthetic and mechanical properties has increased and gradually replaced metal-ceramic restorations. Especially, CAD/CAM technology has opened a new era in fabricating the dental ceramic restorations. This overview will take a look at the past, present and future possibility of the dental ceramic materials.

  • PDF

A STUDY ON FRACTURE STRENGTH OF COLLARLESS METAL CERAMIC CROWN WITH DIFFERENT METAL COPING DESIGN (금속코핑 설계에 따른 Collarless Metal Ceramic Crown의 파절강도에 관한 연구)

  • Yun, Jong-Wook;Yang, Jae-Ho;Chang, Ik-Tae;Lee, Sun-Hyung;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.454-464
    • /
    • 1999
  • The metal ceramic crown is currently the most popular complete veneer restoration in dentistry, but in many cases, the metal cervical collar at the facial margin is unesthetic and unacceptable. Facial porcelain margin has been used in place of it. But this dose not solve the problems, such as dark gingival discoloration and cervical opaque reflection of porcelain veneer. Recently, metal copings which were designed to terminate its labio-cervical end on the axial walls coronal to the shoulder have been clinically used to solve the esthetic problem of metal ceramic crown. But in this design, porcelain veneer of labio-cervical area which is not supported by metal may not be able to resist the stress during cementation and mastication. The purpose of this study was to evaluate fracture strength and fractured appearance of crowns according to different coping designs. A resin maxillary left central incisor analogue was prepared for a metal ceramic crown, and metal dies were made with duplication mold. Metal copings were made and assigned to one of four groups based on facial framework designs: group 1, coping with 0.5mm metal collar; group 2, metal extended to the shoulder; group 3, metal extended to 1mm coronal tn the shoulder: group 4, metal extended to 2mm coronal to the shoulder. Copings and crowns were adjusted to be same size and thickness, and cemented to metal dies with zinc phosphate cement by finger pressure. Fracture strength was measured with Instron Universal Testing Machine. Metal dies were anchored in Three-way-vice at 3mm below finish line and at $130^{\circ}$ inclined to the long axis of the crown. Load was directed lingually at 2mm below midincisal edge. Load value at initial crack and at catastrophic fracture was recorded. The results obtained were as follows : 1. Fracture strength values at initial crack were higher in groups 1, 2 than in groups 3, 4 but this difference was not statistically significant(P<0.05). 2. Conventional metal collared crown had greater catastrophic fracture strength than any other collarless crowns. 3. The greater the labial metal coping reduction, the lower the catastrophic fracture strength of crowns but when more than 1mm of labial metal reduction was done, the difference in strengths was not statistically significant(p<0.05). 4. The strongest collarless coping design was group 2.

  • PDF