지중온도회복을 고려한 지열 히트펌프 시스템의 운전방법 검토 (Study on the Operation Method of Ground Source Heat Pump System Considering Recovery of Ground Temperature)

  • 배상무;전재영;권영식;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.24-30
    • /
    • 2020
  • Ground source heat pump (GSHP) systems are actively introduced as cooling and heating conditioning systems of buildings due to annual stable performance and easily maintenance. However, ground temperature imbalance is occurred when the GSHP is used for a long period. Therefore, in this study, we proposed the operation method of the system that considered the recovery time of heat source temperature. The entering water temperature (EWT) and heat exchange rate (HER) were comparatively analyzed according to the continuous and intermittent operation. Furthermore, the underground thermal environment was evaluated by numerical analysis model. As the result, the intermittent operation was a maximum of 12.3% higher HER during the heating period than the continuous operation. In addition, the overall ground heat source temperature at the intermittent operation was higher than it at the continuous operation.

바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구 (A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.

신재생에너지 이용 과채류에 대한 소비자 인식 및 지불의사에 관한 연구 (A Study on Consumers' Perception and Willingness to Pay for Fruits and Vegetables Using Renewable Energy)

  • 김성휘;이춘수
    • 한국유기농업학회지
    • /
    • 제29권4호
    • /
    • pp.485-505
    • /
    • 2021
  • This study investigated consumers' perceptions and willingness to pay (WTP) for fruit and vegetables grown using renewable energy such as solar power, geothermal, waste heat from incinerators, hot water from thermal power plants. To this end, this study conducted an online survey of 1,050 consumers in Seoul, Gyeonggi, and the six metropolitan cities, and the main findings are as follows. First, most of the consumers perceived climate change as a serious problem, and 82.8% recognized the government's declaration of carbon zero was appropriate, which means that the government's active response to climate change is important. Second, on the pros and cons of the use of renewable energy when cultivating fruits and vegetables, opinions in favor of solar power were the highest, followed by geothermal heat, waste heat from waste incineration plants, and thermal power generation hot drainage. Third, at least 28.0% to 41.7% of consumers were willing to purchase fruits and vegetables using renewable energy more expensive than fruits grown using fossil energy such as kerosene. This means that the fruit and vegetable market using renewable energy is valuable as a niche market.

공동주택의 공기열원 히트펌프 적용가능성 검토를 위한 운전성능 및 탄소배출량 평가 (Evaluation of Operational Performance and Carbon Emissions for the Feasibility of Air Source Heat Pump Application in Residential Buildings)

  • 김준석;김종수;전용석
    • 한국지열·수열에너지학회논문집
    • /
    • 제20권2호
    • /
    • pp.24-36
    • /
    • 2024
  • This study analyzed the feasibility of the air source heat pump in residential buildings based on operational performance and carbon emissions. The operational performance and carbon emissions were compared between a gas boiler and an air source heat pump by calculating the annual heating and hot water load based on the 21A and 36A models for actual residential buildings. For the operational performance of the air source heat pump, the lowest (2.3) and highest COP (5.9) were attained during the winter and summer seasons, respectively. The carbon emissions depend on the amount of energy consumed during operations. An air source heat pump consumed 65.10% and 65.4% less energy per year in the 21A and 36A models, respectively compared to the existing gas boiler. Consequently, for air source heat pump carbon emissions were also reduced by 13.3% and 15.1% per year for the 21A and 36A models, respectively. It shows the effectiveness of applying an air source heat pump compared to an existing gas boiler.

순환식 지하수 수막시스템 그린하우스 난방을 위한 스탠딩컬럼웰 열교환율 산정 (Estimation of Heat Exchange Rate of Standing Column Well for Sustainable Groundwater Curtain for Greenhouse Heating)

  • 심병완;백승균;정성훈
    • 한국지열·수열에너지학회논문집
    • /
    • 제20권2호
    • /
    • pp.11-23
    • /
    • 2024
  • In order to design a standing column well (SCW) for a sustainable groundwater curtain system for greenhouse heating, we conducted parameter sensitivity tests. These tests simulated the outlet temperature changes of the SCW in a groundwater recirculating greenhouse cultivation system. Our modeling considered ground thermal conductivity and hydrogeological conditions. Specifically, we examined several factors, including SCW length, enhanced thermal conductivity of the ground, and groundwater circulation rate. The simulation results indicated that there was not a significant difference in the heat exchange rate based on the characteristics of enhanced thermal conductivity. However, we anticipate a substantial difference in the case of varying SCW lengths. Therefore, we conclude that the simulation results are primarily influenced by conductive heat exchange values, as the circulating water remains at a constant groundwater level.

Durability enhancement of anion exchange membranes for water electrolysis: an updated review

  • Akter, Mahamuda;Park, Jong-Hyeok;Kim, Beom-Seok;Lee, Minyoung;Jeong, Dahye;Shin, Jiyun;Park, Jin-Soo
    • 한국표면공학회지
    • /
    • 제55권6호
    • /
    • pp.319-327
    • /
    • 2022
  • Ion exchange membranes have been developed from laboratory tools to industrial products with significant technical and trade impacts in the last 70 years. Today, ion exchange membranes are successfully applied for water and energy for different electro-membrane processes. Hydrogen could be produced by electrochemical water splitting using renewable energy, for example, solar, biomass, geothermal and wind energy. This review briefly summarizes the recent studies reporting the state-of-the-art anion-exchange membrane water electrolysis, especially focusing on the enhancement of the durability of anion-exchange membranes. Anion-exchange membrane water electrolysis could be used as inexpensive non-noble metal electrocatalysts that are capable of producing low cost of hydrogen. However, the main challenge of anion-exchange membrane water electrolysis is to increase the performance and durability. In this mini review, the limiting factors of the durability and the technology enhancing the durability will be discussed for anion exchange membrane water electrolysis.

지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES) (A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage)

  • ;한정상;한혁상;한찬;김형수
    • 자원환경지질
    • /
    • 제38권6호
    • /
    • pp.717-729
    • /
    • 2005
  • 일반적으로 대규모 건물의 피크 냉방 부하는 난방부하보다 크다. 북위도의 한냉한 지역에 소재한 대규모건물의 냉난방 설비는 건물 내부에서 생성되는 발열량과 태양으로부터 획득되는 열량에 따라 좌우된다. 최대 냉방부하에 적합하도록 냉난방설비와 지중루프를 설치하는데 소요되는 비용은 일반적으로 초기투자비가 적게 드는 전통적인 HVAC시스템에 비해 다소 고가이다. 빙축열조(Thermal ice storage, TES)시스템은 과거 수년동안 일반 HVAC에서 냉동기의 용량을 축소시키거나 최대 전력부하 시간대를 바꾸기 위해 사용되어온 기술이다. 일반적으로 건물 난방을 위해서는 보일러와 같은 전통적인 난방설비를 이용하고 그 다음날의 건물냉방을 위해서는 전력료가 저렴한 야간에 빙축을 시키는 빙축열기법을 이용한다. 얼음에서 추출한 잠열 에너지의 장점을 이용하기 위해 설계된 분배시스템(distribution system)과 열원과 열배출원(열침, sink)대신에 지중열 교환기(지중루프)를 이용하면 많은 장점이 있다. 공간 난방과 급탕을 공급하기위한 분리형 설비를 별도로 사용하지 않아도 된다. 공간난방용으로 소요되는 설비용량을 축소시킬 수 있으며-소요 지중열 교환기의 규격과 비용을 절감시킴은 물론 지열 HVAC시스템의 효율을 배가 시킬 수 있으며 온실가스 배출량을 대폭 감축시킬 수 있다. 또한 TES를 적용하면 대규모 건물의 냉난방부하와 열펌프의 용량을 $40\~60\%$ 정도 감축시킬 수 있으며 설비대수와 기계실 공간을 줄일 수 있다. 뿐만아니라 피크 냉난방부하를 토대로 설계한 지원 열펌프 시스템(Ground source heat pump system)의 지중루프를 $1/4\~1/3$가지 줄일 수 있어 도심지역에서 지중루프를 설치할 때 장애요인인 지중루프 설치공간문제와 지중암석의 열적특성문제를 동시에 해결할 수 있다.문이며, 따라서 $^{137}Cs$의 분포는 광물분포 보다는 TOC의 함량에 더 큰 영향을 받고 있음을 보여준다.과 위기 고조 단계, 그리고 갈등 해소 단계등 모든 시기에서 두 신문의 주요 행위자 구성에 있어서 차이가 나타났다. 다시 말해, 조선일보는 기본적으로 총파업을 둘러싼 문제의 구성과 발전, 해소 과정에서 정당이나 대통령, 야당 지도자 등과 같은 정치관련 행위자를 강조하고 있었다. 반면에, 한겨레는 대체로 로든 사건진행 단계에서 노동 관련 단체들과 시민단체의 역동적인 연대와 활동에 초점을 맞추고 있는 것으로 나타났다.술 후 24시간에 599.4$\pm$145.6, 678.8 $\pm$256.4였다(t-test, p < 0.05). 동종 수혈은 RAP군에서 34명 중 7명에서(20.6$\%$), 대조군에서는 46명중 16명에서(34.8$\%$) 시행되어, RAP군에서 유의하게 빈도가 낮았다(Chi-square test, p < 0.05). 결론: 역행성 자가 충전법은 심폐바이패스의 충전에 의한 혈액희석을 최소화함으로서, 개심술 후 출혈과 동종수혈을 또한 줄이는 데 효과적인 방법이 될 수 있다고 생각된다.타내지 않았다.성 교사, 가정 전공 교사가 그렇지 않은 교사보다 해석적, 해방적 행동목표를 더 중요하게 인식하고 있었다. 특히 가정교육 철학을 배운 경험이 있는 교사가 그렇지 않은 교사보다 해방적 행동체계 목표를 중요시하는 것으로 나타났다. 이 연구 결과는, 실천 비판적인 가정 교과의 본질을 구현하기 위해서는 주생활 영역의 교육과정에 기술적, 해석적, 해방적 행동에 대한 목표들을 고루 포함하여야 하며 특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한

개방형 지열 히트펌프 시스템의 운전 특성 (Operation Characteristics of Open Type Geothermal Heat Pump)

  • 임효재;공형진;송윤석;박성구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.701-706
    • /
    • 2006
  • Groundwater heat pump systems are the oldest of the ground-souce systems and it has various type. Standing column well type are must be located in hard rock geology site and produce sufficient water for the conventional open loop system. These system are indirect type(the building circulating loop and ground water are intercept). Existence of the exchanger the foundation protect water quality to use of open loop. The design of open loop system are concern on the power requirements. An experimental study was analysis the extremely heating operation COP of ground water heat pump system. Operation efficiency of the 50RT systems shows that, COP $2.9{\sim}5.0$ in heating operation. And generally it shows 3.4.

  • PDF

종합적 물리탐사에 의한 파쇄대 및 심부 지하수 탐사 (Frture mapping and deep-seated ground water exploration in the crystalline rocks by integrated geophysical techniques)

  • 정승환;김정호;조인기;전정수
    • 지질공학
    • /
    • 제2권2호
    • /
    • pp.113-130
    • /
    • 1992
  • 지하 심부에 발달된 파쇄대 및 단층등은 지하수의 유통통로가 되어 심부 지하수 개발과 직접적인 관련이 있다. 그러므로 지표에서 지하 파쇄대 및 단층을 탐지함은 심부 지하수 개발 대책 수립에 대단히 중요하다. 본 연구에서는 이와 같은 문제에 대한 물리탐사법의 확립을 위해 경주 보문 관관단지내에서 다수의 물리탐사법을 동원하여 종합적인 탐사를 실시 그 자료를 해석하였다. 경주지역은 자력탐사, VLF 전자탐사, 쌍극자 배열 전기탐사, CSAMT 탐사등이 실시되었다. 자려탐사의 목적은 관입암으로 추정되는 화성암의 분포상황의 파악에 VLF 전자탐사는 지표천부의 파쇄대의 탐지에 있다. 쌍극자 배열 전기탐사는 비교적 천부으 비저항 분포 및 단층 파쇄대의 탐지에 CSAMT 탐사는 비교적 심부까지의 비저항 분포 및 단층 파쇄층 탐지에 있다. 경주지역 탐사자료의 종합적인 해석 결과 자력탐사에 의해 퇴적암 하부에 발달하는 화강암의 분포상황을 파악할 수 있었으며, VLF 탐사로써 지표천부의 다수의 파쇄대를 확인하였다. 자력탐사와 전기탐사 그리고 전기탐사의 종합적인 해석에 의해 거의 남북 방향으로 달리는 구조선 및 비저항 분포 상태를 파악할 수 있었으며 이에 의하여 시추가 추천되었다.

  • PDF

EMP 방호시설의 덕트 및 배관 최적 설계 방안 (Design Optimization for Air Ducts and Fluid Pipes at Electromagnetic Pulse(EMP) Shield in Highly Secured Facilities)

  • 방승기;김재훈
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권4호
    • /
    • pp.15-24
    • /
    • 2014
  • This study conducted a computational fluid dynamics(CFD) analysis to find an appropriate diameter or sectional area of air ducts and fluid pipes which have an electromagnetic pulse(EMP) shied to protect indoor electronic devices in special buildings like military fortifications. The result shows that the optimized outdoor air intake size can be defined with either the ratio of the maximum air velocity in the supply duct to the air intake size, or the shape ratio of indoor supply diffuser to the outdoor air intake. In the case of water channel, the fluid velocity at EMP shield with the identical size of the pipe, decreases by 25% in average due to the resistance of the shield. The enlargement of diameter at the shield, 2 step, improves the fluid flow. It illustrated that the diameter of downstream pipe size is 1step larger than the upstream for providing the design flow rate. The shield increases friction and resistance, in the case of oil pipe, so the average flow velocity at the middle of the shield increase by 50% in average. In consideration of the fluid viscosity, the oil pipe should be enlarged 4 or 5 step from the typical design configuration. Therefore, the fluid channel size for air, water, and oil, should be reconsidered by the engineering approach when EMP shield is placed in the middle of channel.