• Title/Summary/Keyword: geometric standard deviation

Search Result 101, Processing Time 0.029 seconds

Collection Efficiency of Electrostatic Precipitator using Moment Method (모멘트 방법을 이용한 전기집진기의 집진 효율)

  • 정창훈;이규원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.345-353
    • /
    • 2002
  • A study of polydispersed aerosol dynamics by Electrostatic Precipitator (ESP) was carried out. The log-normal particle size distribution was assumed and moment method was considered. In order to apply moment method in Deutsch-Anderson equation, Cunningham slip correction factor and Cochet's charge equation were simplified for certain range of particle size. The three parameters, which explain the particle size distribution, such as total number concentration, geometric mean diameter, and geometric standard deviation were considered to derive the analytic solution. The obtained solution was compared with available numerical results (Bai et al., 1995). The comparison of the numerical and analytic results showed a good agreement.

Automatic Image Mosaicking

  • Song Nak-hyun;Cho Woosug;Cho Seong-Ik;Yun YoungBo
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.121-124
    • /
    • 2004
  • This paper proposed the method of creating image mosaic in automated fashion. It is well known that geometric and radiometric balance in adjacent images should be maintained in mosaicking process. The seam line to minimize geometric discontinuity was extracted using Minimum Absolute­Gray-Difference Sum considering constraint condition in search width. To maintain the radiometric balance of images acquired at different time, we utilized Match Cumulative Frequency, Match Mean and Standard Deviation and Hue Adjustment algorithm. The mosaicked image prepared by the proposed method was compared with those of commercial software. Experiments show that seam lines were extracted significantly well from roads, rivers. ridgelines etc. and Match Cumulative Frequency algorithm was performed pretty good in histogram matching

  • PDF

Analysis of Aerosol Dynamics, Heat and Mass Transfer in the Modified Chemical Vapor Deposition (수정된 화학증착공정에서 에어로졸 역학, 열전달 및 물질전달 해석)

  • Park, Kyong Soon;Lee, Bang Weon;Choi, Mansoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.262-271
    • /
    • 1999
  • A study of aerosol dynamics has been done to obtain axially and radially varying size distributions of particles generated in the Modified Chemical Vapor Deposition process. Heat and mass transfer have also been studied since particle generation and deposition strongly depend on the temperature field in a tube. Bimodal size distributions of particles have been obtained both in the particulate flow and in the deposited particle layer for the first time using the sectional method to solve aerosol dynamics. Variations of geometric mean diameter, geometric standard deviation have been studied for various parameters; flow rates and maximum wall temperature. The comparison between one-dimensional and two-dimensional approaches has also been made.

An Experiment on the Particle Collection Characteristics in a Packed Wet Scrubber (충진층식 세정집진기의 집진특성 실험)

  • 유경훈;노희환;최은수;김종균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.305-311
    • /
    • 2003
  • DOP aerosol particles with geometric mean diameter of 0.5-3.0 ${\mu}{\textrm}{m}$, geometric standard deviation of 1.1-1.3 and total number concentration of 1,500-8,000 Particles/㎤ were used to determine collection efficiencies of a packed wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. Meanwhile, as for the particle size variation, all of the collection efficiency curves increased rapidly between 0.57-1.41${\mu}{\textrm}{m}$ for the range of water injection rate above 30 L/min. It was also seen that the collection efficiency of a packed wet scrubber is mainly governed by the mechanism of inertial impaction.

An Experimental Study on the Characteristics of Generated Particle using Homogeneous Condensation Particle Generator (응축입자 발생기에서의 입자 발생특성에 관한 실험적 연구)

  • Kim, J.H.;Kim, S.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.392-397
    • /
    • 2000
  • Mono-disperse particles generated by a condensation particle generator are widely used to meet the experimental and industrial needs. The characteristics of particles generated by homogeneous nucleation have been studied experimentally using a laminar flow condensation particle generator. Dry nitrogen gas saturated with oleic acid vapor was cooled well below the saturation temperature causing the highly supersaturated vapor to nucleate. The dependence of GSD(Geometric Standard Deviation), GMD(Geometric Mean Diameter), and the mass concentration of particles on the temperature at the evaporator, flow rate and the temperature condition at condenser was studied. The experimental results show that the mass concentration of particles is affected by the radial temperature profile at condenser. Nucleation at the center of the condenser causes the mass concentration of particles to increase. The experimental results also show that the suppression of additional nucleation by a constant temperature condition at the condenser increases the mean diameter of particle.

  • PDF

An Experiment on Particle Collection Characteristics of a Duct-type Wet Scrubber (덕트형 세정집진기의 입자포집 특성실험)

  • Yoo, Kyung-Hoon;Yeo, Kuk-Hyun;Son, Seung-Woo;Hwang, Kwang-Ho;Jung, Jin-Won;Kim, Yoon-Shin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1795-1800
    • /
    • 2004
  • DOS and NaCl aerosol particles with geometric mean diameter of $0.1{\sim}3.0{\mu}m$ geometric standard deviation of $1.1{\sim}1.8$ and total number concentration of $450{\sim}400$ $particles/cm^3$ were used to determine collection efficiencies of a duct-type wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. It was also seen that the collection efficiency of the Duct-type wet scrubber is mainly governed by the mechanism of inertial impaction.

  • PDF

Evaluation of Ultra-high and High Degree Geopotential Models for Improving the KGEOID98

  • Yun, Hong-Sic
    • Korean Journal of Geomatics
    • /
    • v.2 no.1
    • /
    • pp.7-15
    • /
    • 2002
  • Recent development of ultra-high and high degree Earth geopotential model opens new avenues to determine the Earth gravity field through spectral techniques to a very high accuracy and resolution. However, due to data availability, quality, and type, the performance of these new EGMs needs to be validated in regional or local scale geoid modeling. For establishing the best reference surface of geoid determination, recent geopotential models are evaluated using GPS/Leveling-derived geometric geoid and the Korean gravimetrical GEOID (KGEOID98) developed by National Geography Institute in 1998. Graphical and statistical comparisons are made for EGM96, GFZ97, PGM2000A and GPM98A models. The mean and standard deviation of difference between geometric height and geoid undulation calculated from GFZ97 are $1.9\pm{46.7}\;cm$. It is shown that the GFZ97 and the GPM98A models are better than the others in the Korean peninsula because the GFZ97 has a smaller bias. It means that the KGEOID98 needs some improvement using the GFZ97 instead of EGM96.

  • PDF

Evaluation of General 2D Geometric Transport Code, HELIOS

  • Kim, Taek-Kyum;Kim, Young-Jin;Chang, Moon-Hee
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.58-63
    • /
    • 1996
  • This paper is devoted to evaluating the accuracy of general 2D geometric transport code, HELIOS, and determining the order of merit in modeling for some important HELIOS input parameters. Benchmark test for 12 critical lattices show that HELIOS predicts criticality accurately within experimental uncertainties, showing only 250 pcm overestimation with a standard deviation of 450 pcm. The sensitivity test suggest that current coupling order, neutron group library, geometrical modeling, and resonance options must be considered carefully to obtain accurate results. Especially, current coupling order and sub-rings in fuel regions turn out to be most critical in HELIOS modeling. For MOX loaded cores, it is additionally necessary to pay attention to the resonance option and the validity of small group neutron library.

  • PDF

Development of Color Inspection System of Printed Texture using Scanner (스캐너를 이용한 직물의 색상검사기 개발)

  • 조지승;정병묵;박무진
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.70-75
    • /
    • 2003
  • It is very important to inspect the color of printed texture in the textile process. The standard colorimetric system used for the recognition of the color in the textile industry. It uses XYZ color system defined by CIE (Commission Internationale de 1Eclairage), but is too expensive. Therefore, in this paper, we propose a color inspection system of the printed texture using a color scanner. Because the scanner uses RGB value for color, it is necessary the mapping from RGB to XYZ. However, the mapping is not simple, and the scanner has even positional deviation because of the geometric characteristics. To transform from RGB to XYZ, we used a NN (neural network) model and also compensated the positional deviation. In real experiments, we could get fairly exact XYZ value from the proposed color inspection system in spite of using a color scanner with large measuring area.

A Study on Estimation on Air Exchange Rate and Source Strength in Indoor Air Using Multiple Measurements of Nitrogen Dioxide (이산화질소 다중측정을 이용한 실내공기의 환기량 밀 발생량 추정에 관한 연구)

  • Yang, Won-Ho;Lee, Ki-Young;Chung, Moon-Ho;Zong, Moon-Shik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.160-169
    • /
    • 2000
  • Daily indoor and outdoor nitrogen dioxide ($NO_2$) concentration for 30 days were measured in 28 houses with questionnaire of housing characteristics in Brisbane, Australia. Using mass balance equation and regression analysis, penetration factors and source strength factors were calculated. The penetration factors of 27 houses except one house were between zero and 1, though penetration factor should be between zero and 1 by means of mass balance equation. Relationship between indoor and outdoor concentrations in each 27 house was calculated using regression analysis. According to the obtained linear regression equation, the slope means penetration factor and the intercept means source strength factor. Calculated mean and standard deviation of coefficients of determination ($R^2$) in electric and gas range houses were $0.70{\pm}0.13$ and $0.57{\pm}0.21$, respectively. The source strength factors were more than zero in 27 houses. Mean and standard deviation of slopes in electric and gas range houses were $0.65{\pm}0.18$ and $0.56{\pm}0.12$, respectively. Mean and standard deviation of intercepts in electric and gas range houses were $1.49{\pm}1.25$ and $5.77{\pm}3.55$, respectively. Air exchange rate and source strength were calculated from penetration factor and source strength factor, respectively. Geometric mean and standard deviation of calculated air exchange rates in 27 houses were $1.1/hr{\pm}1.5$. Presence of gas range was the most significant factor contributing to indoor $NO_2$ level in house characteristics (p=0.003). In gas range houses, source strengths ranged from 4.1 to $33.1cm^3/hr{\cdot}m^3$ with a mean $12.7cm^3/hr{\cdot}m^3$ and a standard deviation 9.8. The source strengths of gas range houses were significantly different from those of electric range houses by t-test (p<0.001)

  • PDF