• Title/Summary/Keyword: geometric safety

Search Result 415, Processing Time 0.032 seconds

A study on the advanced mirror mold for automobile (첨단 자동차용 거울의 금형에 관한 연구)

  • 홍민성;백철승
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.134-140
    • /
    • 1999
  • The side mirrors play an important role in driver's safety and convenience. People drive safely based on the side mirrors and room mirror through observation of environment. However, the drivers can not completely confront environments because of the dead angle of the side mirrors. In this research, based on geometric optics and geometric modeling, aspheric surfaces of the side mirror mold with dead angle free has been designed and machined in CNC machining center, Surface roughness of the mold was evaluated by using surface shaping system. The analysis on the shape of formed mirrors shows the mirrors have been reduced the dead angle comparing with the original mold.

  • PDF

Development of Korean Standard Horizontal Design Spectrum Based on the Domestic and Overseas Intra-plate Earthquake Records (국내외 판내부 지진기록을 이용한 한국 표준수평설계스펙트럼의 개발)

  • Kim, Jae Kwan;Kim, Jung Han;Lee, Jin Ho;Heo, Tae Min
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.369-378
    • /
    • 2016
  • The design spectrum for Korea, which is known to belong to an intra-plate region, is developed from the ground motion records of the earthquakes occurred in Korea and overseas intra-plate regions. The horizontal spectrum is defined as geometric mean spectrum, GMRotI50. From the statistical analysis of the geometric mean spectra, a mean plus one standard deviation spectrum in lognormal distribution is obtained. Regression analysis is performed on this curve to determine the shape of spectrum including transition periods. The developed design spectrum is valid for the estimation both spectral acceleration and displacement.

Improvement of Quantitative Condition Assessment Criteria for Reservoir Embankment Safety Inspection Considering Characteristics of Small Reservoirs in Korea (소규모 저수지의 특성을 고려한 제체 안전진단의 정량적 상태평가 기준 개선)

  • Jeon, Geonyeong;Bang, Donseok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.5
    • /
    • pp.27-38
    • /
    • 2021
  • The physical condition assessment criteria of fill dam safety inspection are now weakly regulated and inappropriate for small agricultural reservoirs since these criteria have fundamental backgrounds suitable for large-scale dams. This study proposes the degree (critical values) of defects for the quantitative condition assessment of the embankment in order to prepare the condition assessment criteria for a small reservoir with a storage capacity of less than one (1) million cubic meters. The critical values of defects were calculated by applying the method that considers the size ratios based on the dimensional data of reservoirs, and the method of statistical analysis on the measured values of the defect degree which extracted from comprehensive annual reports on reservoir safety inspection. In comparison with the current criteria, the newly proposed critical values for each condition assessment item of the reservoir embankment are presented in paragraphs 4 and 6 of the conclusion. In addition, this study presents a method of displaying geometric figures to clarify the rating classification for condition assessment items with the two defect indicators.

Proposal of residual stress mitigation in nuclear safety-related austenitic stainless steel TP304 pipe bended by local induction heating process via elastic-plastic finite element analysis

  • Kim, Jong-Sung;Kim, Kyoung-Soo;Oh, Young-Jin;Oh, Chang-Young
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1451-1469
    • /
    • 2019
  • This paper proposes a residual stress mitigation of a nuclear safety-related austenitic stainless steel TP304 pipe bended by local induction heating process via performing elastic-plastic finite element analysis. Residual stress distributions of the pipe bend were calculated by performing finite element analysis. Validity of the finite element analysis procedure was verified via comparing with temperature histories measured by using thermocouples, ultrasonic thickness measurement results, and residual stress measurement results by a hole-drilling method. Parametric finite element stress analysis was performed to investigate effects of the process and geometric shape variables on the residual stresses on inner surfaces of the pipe by applying the verified procedure. As a result of the parametric analysis, it was found that it is difficult to considerably reduce the inner surface residual stresses by changing the existing process and geometric shape variables. So, in order to mitigate the residual stresses, effect of an additional process such as cooling after the bending on the residual stresses was investigated. Finally, it was identified that the additional heating after the bending can significantly reduce the residual stresses while other variables have insignificant effect.

A Study on the Difference of Geometrical Modeling in the Calculation of Shielding and Activation Using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 차폐 및 방사화 계산에서 기하학적 모델링의 차이에 따른 결과 연구)

  • Heo, Seunguk;Song, Yongkeun;Cho, Gyuseok;Han, Moojae;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.429-435
    • /
    • 2017
  • In order to increase the therapeutic effect of radiation, there has been an increase in the use of conventional photon therapy. The intensive care unit should pay more attention to the radiation safety evaluation due to the higher energy and the larger facility compared to the existing Photon treatment. These radiation safety evaluations are mainly performed by using Monte Carlo simulation, and the first thing to be done is geometric modeling. The Heavy-ion treatment facility uses synchrotron as the accelerating device, which is difficult to precisely model geometrically and is mostly modeled briefly. This study investigated the effect of simplification and precise implementation of Dipole magnet among the components of synchrotron acceleration device on the radiation safety evaluation. The results show that the simplified geometric model is overestimated with the precisely implemented geometric model. Therefore, it is considered that the radiological safety evaluation results in more reliable results of the precise geometric modeling.

Exposure assessment of Polynuclear aromatichydrocarbons(PAHs) for heat treat workers using Metalworking fluids (금속가공유 취급 근로자의 다핵방향족탄화수소 노출 평가)

  • Joo, Kui Don;Kim, Eun A;Choi, Seong Bong;Kim, Myeong Ock
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.71-80
    • /
    • 2007
  • The purpose of this study was to assess the ambient level of Polynuclear aromatic hydrocarbons(PAHs), oil mist of the metalworking fluids(MWFs), especially in heat treat industry and non heat treat industry. And we assessed the relationship of the pattern of exposed PAHs with oil mist during survey day. The study population of heat treat industries contained 98 workers, non-heat treat industry contained 40 workers. Personal samples were taken for ambient monitoring of PAHs and oil mist. PAHs was to analyze the relationship of airborne oil mist. The geometric mean of airborne total PAHs was $3.44{\mu}g/m^3$ in heat treat industry and $0.13{\mu}g/m^3$ in non heat treat industry, Pyrene and Benzo(a)pyrene was detected from heat treat industry and Naphthalene in heat treat industry was significantly detected higher than in non heat treat industry. The geometric mean of airborne oil mist was $0.19{\mu}g/m^3$ in heat treat industry and $0.70{\mu}g/m^3$ in non-heat treat industry. The correlation between oil mist and total PAHs was shown below, total PAHs in workers of non heat treat industry and heat treat industry were not significantly correlated with oil mist

Occupational Exposure of Semiconductor Workers to ELF Magnetic Fields (반도체 제조 근로자의 극저주파 자기장 노출 평가)

  • Chung, Eun Kyo;Kim, Kab Bae;Chung, Kwang Jae;Lee, In Seop;You, Ki Ho;Park, Jung-Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.1
    • /
    • pp.42-51
    • /
    • 2012
  • Objectives: To compare the exposure level of extremely low frequency (ELF) magnetic fields among semiconductor workers, shipyard welders and office workers. Methods: To measure the ELF magnetic field concentration, EMDEX LITE (Enertech, USA) were used and monitored for eight hours continuously. Five companies handling the electric and magnetic field (EMF) source were investigated, which the exposure groups were classified into three groups: semiconductor workers, welders, and office workers. Welder group was chosen as a high exposed group and office group as a low exposed group. Results: The arithmetic mean (${\pm}SD$) and geometric mean (GSD) of personal exposure level of semiconductor workers were 0.73 (${\pm}1.33$) ${\mu}T$, 0.43 (2.88) ${\mu}T$, respectively. The ceiling value ranged between 0.18 and 123.2 ${\mu}T$. Welders were exposed high with the arithmetic mean value of 3.46 (${\pm}\;13.46$) ${\mu}T$ and geometric mean value of 0.45 (4.70) ${\mu}T$, respectively, and ceiling value range of 75.5~129.6 ${\mu}T$. The exposure levels of office workers were low compared to other exposed groups; the arithmetic mean 0.05 (${\pm}0.13$) ${\mu}T$, geometric mean 0.03 (2.38) ${\mu}T$ and ceiling value range 0.37~3.35 ${\mu}T$. This study revealed statistically significant differences of the mean ELF magnetic field exposure doses among three groups (p < 0.01). Conclusions: The average ELF magnetic field exposure doses of semiconductor workers were much higher than those of office workers in control group, but were lower than those of welders in high exposure group.

CRITICALITY SAFETY OF GEOLOGIC DISPOSAL FOR HIGH-LEVEL RADIOACTIVE WASTES

  • Ahn, Joon-Hong
    • Nuclear Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.489-504
    • /
    • 2006
  • A review has been made for the previous studies on safety of a geologic repository for high-level radioactive wastes (HLW) related to autocatalytic criticality phenomena with positive reactivity feedback. Neutronic studies on geometric and materials configuration consisting of rock, water and thermally fissile materials and the radionuclide migration and accumulation studies were performed previously for the Yucca Mountain Repository and a hypothetical water-saturated repository for vitrified HLW. In either case, it was concluded that it would be highly unlikely for an autocatalytic criticality event to happen at a geologic repository. Remaining scenarios can be avoided by careful selection of a repository site, engineered-barrier design and conditioning of solidified HLW. Thus, criticality safety should be properly addressed in regulations and site selection criteria. The models developed for radiological safety assessment to obtain conservatively overestimated exposure dose rates to the public may not be used directly for the criticality safety assessment, where accumulated fissile materials mass needs to be conservatively overestimated. The models for criticality safety also require more careful treatment of geometry and heterogeneity in transport paths because a minimum critical mass is sensitive to geometry of fissile materials accumulation.

Development of Road Safety Estimation Method using Driving Simulator and Eye Camera (차량시뮬레이터 및 아이카메라를 이용한 도로안전성 평가기법 개발)

  • Doh, Tcheol-Woong;Kim, Won-Keun
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.185-202
    • /
    • 2005
  • In this research, to get over restrictions of a field expreiment, we modeled a planning road through the 3D Virtual Reality and achieved data about dynamic response related to sector fluctuation and about driver's visual behavior on testers' driving the Driving Simulator Car with Eye Camera. We made constant efforts to reduce the non-reality and side effect of Driving Simulator on maximizing the accord between motion reproduction and virtual reality based on data Driving Simulator's graphic module achieved by dynamic analysis module. Moreover, we achieved data of driver's natural visual behavior using Eye Camera(FaceLAB) that is able to make an expriment without such attaching equipments such as a helmet and lense. In this paper, to evaluate the level of road's safety, we grasp the meaning of the fluctuation of safety that drivers feel according to change of road geometric structure with methods of Driving Simulator and Eye Camera and investigate the relationship between road geometric structure and safety level. Through this process, we suggest the method to evaluate the road making drivers comfortable and pleasant from planning schemes.

  • PDF

An Examination of Blood Lead Levels in Thai Nielloware Workers

  • Decharat, Somsiri;Kongtip, Pornpimol;Thampoophasiam, Prapin;Thetkathuek, Anamai
    • Safety and Health at Work
    • /
    • v.3 no.3
    • /
    • pp.216-223
    • /
    • 2012
  • Objectives: The objectives of this study were to determine the lead levels in blood samples from nielloware workers, to determine airborne lead levels, to describe the workers' hygiene behaviors, and to ascertain and describe any correlations between lead levels in blood samples and lead levels in airborne samples. Methods: Blood samples and airborne samples from 45 nielloware workers were collected from nielloware workplaces in Nakhon Sri Thammarat Province, Thailand. Lead levels were determined by flame atomic absorption spectrometry (FAAS), at a wavelength of 283.3 nm. FAAS was used especially adequate for metals at relatively high concentration levels. Results: The geometric mean of the 45 airborne lead levels was 81.14 ${\mu}g/m^3$ (range 9.0-677.2 ${\mu}g/m^3$). The geometric mean blood lead level of the 45 workers was 16.25 ${\mu}g/dL$ (range 4.59-39.33 ${\mu}g/dL$). No worker had a blood lead level > 60 ${\mu}g/dL$. A statistically significantly positive correlation was found between airborne lead level and blood lead levels (r = 0.747, p < 0.01). It was observed that personal hygiene was poor; workers smoked and did not wash their hands before drinking or eating. It was concluded that these behaviors had a significant correlation with blood lead levels (p < 0.001). Conclusion: Improvements in working conditions and occupational health education are required due to the correlation found between blood leads and airborne lead levels.