• 제목/요약/키워드: generator

검색결과 8,674건 처리시간 0.029초

Fluid-elastic Instability Evaluation of Steam Generator Tubes

  • Cho, Young Ki;Park, Jai Hak
    • International Journal of Safety
    • /
    • 제11권1호
    • /
    • pp.1-5
    • /
    • 2012
  • It has been reported that the plugged steam generator tube of Three Mile Island Unit 1 in America was damaged by growing flaw and then this steam generator tube destroyed the nearby steam generator tubes of normal state. On this account, stabilizer installation is necessary to prevent secondary damage of the steam generator tubes. The flow-induced vibration is one of the major causes of the fluid-elastic instability. To guarantee the structural integrity of steam generator tubes, the flow-induced vibration caused by the fluid-elastic instability is necessary to be suppressed. In this paper, the effective velocity and the critical velocity are calculated to evaluate the fluid-elastic instability. In addition, stability ratio value of the steam generator tubes is evaluated in order to propose one criterion when to determine stabilizer installation.

계자코일 파라메터추정 기법을 이용한 동기발전기의 성능개선 (Performance Improvement of Synchronous Generator using Exciter Control with Field Coils Parameter Estimation Technique)

  • 강성현;박성미;이화춘;박성준
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.31-40
    • /
    • 2013
  • This paper proposes a performance improvement of synchronous generator using exciter control with field coils parameter estimation technique. In general, the generator excitation system controller uses the PID controller. When the Field winding impedance changed, the PID gains must be changed. General method is difficult to apply varying capacity of the synchronous generator. The proposed control method determine automatically measure the internal impedance of the synchronous generator's exciter and configure the controller. This method can be applied regardless of the generator capacity. So it is possible to apply a variety of synchronous generator systems. The validity of the proposed algorithm is verified by simulations and experiments.

평판에서의 열전달 및 와류발생기에 의한 열전달 촉진에 관한 연구 (A Study on the Heat Transfer from a Flat Plate and the Heat Transfer Enhancement by the Vortex Generator)

  • 유성연;송시영;박종학
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1447-1452
    • /
    • 2003
  • Vortex is very interesting flow phenomena on the heat transfer enhancement. In the present study, naphthalene sublimation technique is used to determine the average and local mass transfer coefficients on the flat plate with vortex generator. A parametric study with Reynolds number and angle of attack is carried out to investigate the heat transfer enhancement. The heat transfer coefficients on the flat plate with rectangular type and delta type vortex generator are compared with those of the flat plate without the vortex generator. Comparing heat transfer coefficients between rectangular type and delta type vortex generator, rectangular type vortex generator has much higher value than delta type vortex generator at the same condition.

  • PDF

심구 또는 이중 농형 회전자를 가진 유도기의 전동 또는 발전 운전시 특성 해석 (Characteristics Analysis for Motor or Generator Operating of Induction Machine with Deep or Double Cage Rotor)

  • 김종겸
    • 신재생에너지
    • /
    • 제10권4호
    • /
    • pp.3-8
    • /
    • 2014
  • Both of induction generator and synchronous generator is available in the hydroelectric power plant. If the output of the power station is large, the synchronous generator is mainly used but when its output is low, the induction generator is often used. If the output capacity is small, there is a case in which induction motor is used as a generator. Torque at rated operation and start of the induction motor is different depending on the shape of the rotor. Small and medium-sized squirrel-cage induction motor is used primarily double cage rotor or deep bar. In this study, we attempt to interpret characteristics for double cage rotor or deep bar that occur when operating in the induction generator based on the parameters that have been designed and manufactured as an induction motor.

진동모니터링을 위한 자가진동발전기의 개발 (Development of Vibration Powered Generator for Vibration Monitoring)

  • 김재민;최남섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.434-441
    • /
    • 2003
  • This paper presents a generator for stand-alone vibration monitoring system of bridge structure based on ambient vibration of bridge. In this paper, a novel electric power generator which has minimum effect of armature reaction is proposed. The related mechanical and electrical design equations are obtained and a pilot generator has been implemented. In addition, the charging system for extremely low generator current is discussed, and some improvements are identified for the system. This investigation reveals that diode characteristics of rectifier is dominant factor in the charging process. Finally, both the simulation, which uses real measurement data of the Namhae bridge as input of the pilot generator, and indoor test are carried out. The results showed the applicability and effectiveness of the stand-alone vibration powered generator.

  • PDF

발전기 보호용 계자상실 계전기의 적용 분석 (Application Analysis for Loss of Excitation Relay of Generator Protection)

  • 오용택;박철원
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.322-326
    • /
    • 2014
  • Recently, the LOE(loss of excitation) incidents are occurred in domestic synchronous generator frequently, the synchronous generator protection system has been much attention for the LOE protection of the incidents that threats synchronous generators and power systems. This paper was showed the characteristics and practices of distance relay that widely used LOE protection relaying in generator. Firstly, the operating characteristics and the impedance locus for LOE of the generator protection were introduced. Even if the conventional simulation program is used for modeling, but it is difficult to implement a LOE modeling and simulation of synchronous generator. So, the LOE relay operation data collected from thermal power plant and nuclear power plant in real fields were analyzed. By reviewing the applications of GE Mho relays, the reliability of LOE for synchronous generator protection in domestic were improved.

3D electromagnetic design and electrical characteristics analysis of a 10-MW-class high-temperature superconducting synchronous generator for wind power

  • Kim, J.H.;Park, S.I.;Le, T.D.;Kim, H.M.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권2호
    • /
    • pp.47-53
    • /
    • 2014
  • In this paper, the general electromagnetic design process of a 10-MW-class high-temperature superconducting (HTS) synchronous generator that is intended to be utilized for large scale offshore wind generator is discussed. This paper presents three-dimensional (3D) electromagnetic design proposal and electrical characteristic analysis results of a 10-MW-class HTS synchronous generator for wind power. For more detailed design by reducing the errors of a two-dimensional (2D) design owing to leakage flux in air-gap, we redesign and analyze the 2D conceptual electromagnetic design model of the HTS synchronous generator using 3D finite element analysis (FEA) software. Then electrical characteristics which include the no-load and full-load voltage of generator, harmonic contents of these two load conditions, voltage regulation and losses of generator are analyzed by commercial 3D FEA software.

회전자 형상에 따른 유도발전기 전압강하에 대한 연구 (A Study on the Voltage Drop of Induction Generator along the Rotor Shape)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제64권2호
    • /
    • pp.62-66
    • /
    • 2015
  • Induction generator is easy to durability and maintenance than the synchronous generator. So, recently Induction generator has been widely applied to small-scale hydroelectric power plant. When the rotor is operating faster than synchronous speed, induction machine can generate electric power. Induction generator has a large inrush currents, such as the starting current of the induction motor. Induction motor has been designed a variety of rotor shape in order to reduce starting current. Since the occurrence of high inrush current cause a voltage drop to the system, it will need to reduce possible. Because the starting current of the squirrel-cage induction motor varies in accordance with the rotor shape, it is necessary to analyze the magnitude of inrush current in order to apply to the generator. In this study, we analyzed the inrush current and the voltage drop caused in accordance with the rotor shape of 1500kw induction generator.

전력계통 구조를 고려한 발전기 무효예비력 산정 (Calculation of Generator Reactive Reserve Considering Network Configuration)

  • 서상수;김대정;최윤혁;이병준
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.711-716
    • /
    • 2011
  • This paper defines a generator reactive reserve considering power system network. Conventional generator reserve is calculated by the difference between the maximum reactive power output of generator and the current reactive power of generator. However, all generators could not affect on the whole power system. Thus, the effective generators should be selected by sensitivity analysis. The sensitivity depends on network configuration is the relation between generator reactive power outputs and reactive power loads. Using the sensitivity, the effective generator reactive reserve can be calculated.

Design of Trajectory Generator for Performance Evaluation of Navigation Systems

  • Jae Hoon Son;Sang Heon Oh;Dong-Hwan Hwang
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권4호
    • /
    • pp.409-421
    • /
    • 2023
  • In order to develop navigation systems, simulators that provide navigation sensors data are required. A trajectory generator that simulates vehicle motion is needed to generate navigation sensors data in the simulator. In this paper, a trajectory generator for evaluating navigation system performance is proposed. The proposed trajectory generator consists of two parts. The first part obtains parameters from the motion scenario file whereas the second part generates position, velocity, and attitude from the parameters. In the proposed trajectory generator six degrees of freedom, halt, climb, turn, accel turn, spiral, combined, and waypoint motions are given as basic motions with parameters. These motions can be combined to generate complex trajectories of the vehicle. Maximum acceleration and jerk for linear motion and maximum angular acceleration and velocity for rotational motion are considered to generate trajectories. In order to show the usefulness of the proposed trajectory generator, trajectories were generated from motion scenario files and the results were observed. The results show that the proposed trajectory generator can accurately simulate complex vehicle motions that can be used to evaluate navigation system performance.