• Title/Summary/Keyword: general image

Search Result 2,266, Processing Time 0.028 seconds

Ideal Nasal Preferences: A Quantitative Investigation with 3D Imaging in the Iranian Population

  • Kiarash Tavakoli;Amir K. Sazgar;Arman Hasanzade;Amir A. Sazgar
    • Archives of Plastic Surgery
    • /
    • v.50 no.4
    • /
    • pp.340-347
    • /
    • 2023
  • Background Though in facial plastic surgery, the ideal nasal characteristics are defined by average European-American facial features known as neoclassical cannons, many ethnicities do not perceive these characteristics as suitable. Methods To investigate the preferences for nasofrontal angle, nasolabial angle, dorsal height, alar width, and nasal tip projection, manipulated pictures of one male and one female model were shown to 203 volunteer patients from a tertiary university hospital's facial plastic clinic. Results The most aesthetically preferred nasofrontal angles were 137.64 ± 4.20 degrees for males and 133.55 ± 4.53 degrees for females. Acute nasofrontal angles were more desirable in participants aged 25 to 44. The most preferred nasolabial angles were 107.56 ± 5.20 degrees and 98.92 ± 4.88 degrees, respectively. Volunteers aged 19 to 24 preferred more acute male nasolabial angles. A straight dorsum was the most desirable in both genders (0.03 ± 0.78 and 0.26 ± 0.75 mm, respectively). The ideal male and female alar widths were -0.51 ± 2.26 and -1.09 ± 2.18 mm, respectively. More 45- to 64-year-old volunteers preferred alar widths equal to intercanthal distance. The ideal female and male tip projections were 0.57 ± 0.01 and 0.56 ± 0.01, respectively. Conclusion Results indicate that the general Iranian patients prefer thinner female noses with wider nasofrontal angles for both genders. However, the ideal nasolabial angles, dorsal heights, and tip projections were consistent with the neoclassical cannons. Besides ethnic differences, the trend of nasal beauty is also affected by gender, age, and prior history of aesthetic surgery.

Neuroprotective Effect of Aloesin in a Rat Model of Focal Cerebral Ischemia

  • K.J. Jung;Lee, M.J.;E.Y. Cho;Y.S. Song;Lee, Y.H.;Park, Y.L.;Lee, Y.S.;C. Jin
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2003.11a
    • /
    • pp.62-62
    • /
    • 2003
  • It is now convincing that free radical generation is involved in the pathophy siological mechanisms of ischemic stroke, particularly in ischemia-reperfusion injury. The present study, therefore, examined neuroprotective effect of aloesin isolated from Aloe vera, which was known to have antioxidative activity, in a rat model of transient focal cerebral ischemia. Transient focal cerebral ischemia was induced by occlusion of middle cerebral artery for 2 hr with a silicone-coated 4-0 nylon monofilament in male Sprague-Dawley rats under isoflurane anesthesia Aloesin (1, 3, 10, 30 and 50 mg/kg/injection) was administered intravenously 3 times at 0.5, 2 and 4 hr after onset of ischemia. Neurological score was measured 24 hr after onset of ischemia immediately before sacrifice. Seven serial coronal slices of the brain were stained with 2,3,5-triphenyltetrazolium chloride and infarct size was measured using a computerized image analyzer. Treatment with the close of 1 or 50 mg/kg did not significantly reduce infarct volume compared with the saline vehicle-treated control group. However, treatments with the closes of 3 and 10 mg/kg significantly reduced both infarct volume and edema by approximately 47% compared with the control group, producing remarkable behavioral recovery effect. Treatment with the close of 30 mg/kg also significantly reduced infarct volume to a lesser extent by approximately 33% compared with the control group, but produced similar degree of behavioral recovery effect. In addition, general pharmacological studies showed that aloesin was a quite safe compound. The results suggest that aloesin can serve as a lead chemical for the development of neuroprotective agents by providing neuroprotection against focal ischemic neuronal injury.

  • PDF

Proposed Institutional Diagnostic Reference Levels in Computed and Direct Digital Radiography Examinations in Two Teaching Hospitals

  • Emmanuel Gyan;George Amoako;Stephen Inkoom;Christiana Subaar;Barry Rahman Maamah
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.9-14
    • /
    • 2023
  • Background: The detectors of both computed radiography (CR) and direct digital radiography (DR) have a wide dynamic range that could tolerate high values of exposure factors without an adverse effect on image quality. Therefore, this study aims to assess patient radiation dose and proposes institutional diagnostic reference levels (DRLs) for two teaching hospitals in Ghana. Materials and Methods: CR and DR systems were utilized in this study from two teaching hospitals. The CR system was manufactured by Philips Medical Systems DMC GmbH, while the DR system was manufactured by General Electric. The entrance skin doses (ESDs) were calculated using the standard equation and the tube output measurements. Free-in-air kerma (µGy) was measured using a calibrated radiation dosimeter. The proposed institutional DRLs were estimated using 75th percentiles values of the estimated ESDs for nine radiographic projections. Results and Discussion: The calculated DRLs were 0.4, 1.6, 3.4, 0.5, 0.4, 1.1, 1.0, 1.2, and 1.7 mGy for chest posteroanterior (PA), lumbar spine anteroposterior (AP), lumbar spine lateral (LAT), cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively in CR system. In the DR system, the values were 0.3, 1.6, 3.1, 0.4, 0.3, 0.7, 0.6, 0.9, and 1.3 for chest PA, lumbar spine AP, lumbar spine LAT, cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively. Conclusion: Institutional DRLs in nine radiographic projections have been proposed for two teaching hospitals in Ghana for the first time. The proposed DRLs will serve as baseline data for establishing local DRLs in the hospitals and will be a valuable tool in optimizing patient doses.

Cone-beam computed tomographic evaluation of the root canal anatomy of the lower premolars and molars in a Brazilian sub-population

  • Jessica Cecilia Almeida;Amanda Pelegrin Candemil;Gunther Ricardo Bertolini;Aline Evangelista Souza-Gabriel;Antonio Miranda Cruz-Filho;Manoel Damiao Sousa-Neto;Ricardo Gariba Silva
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.77-82
    • /
    • 2023
  • Purpose: This study evaluated anatomical variations in the root canals of the lower premolars and molars in a Brazilian sub-population using cone-beam computed tomography (CBCT). Materials and Methods: In total, 121 CBCT images of patients were selected from a database. All images contained lower first and second premolars and molars on both sides of the arch, fully developed roots, and no treatment, resorption, or calcifications. In each image, the root canals of the lower premolars and molars were evaluated according to the Vertucci classification in On-Demand 3D software in the multiplanar reconstruction with dynamic navigation. Twenty-five percent of the images were re-assessed to analyze intraobserver confidence with the kappa test. Data were statistically evaluated with linear regression to evaluate the correlations of anatomic variations with age and sex, and the Wilcoxon test to analyze the laterality of variations, with a significance level of 5%. Results: The intraobserver agreement (0.94) was excellent. In general, the root canals of lower premolars and molars showed a higher prevalence of type I than other Vertucci classification types, followed by type V in premolars and type II in molars. When the molar roots were evaluated separately, type II was more frequent in mesial roots and type I in distal roots. Although age showed no correlations with the results, sex and laterality showed correlations with tooth 45 and the lower second premolars, respectively. Conclusion: The lower premolars and molars of a Brazilian sub-population showed a wide range of root canal anatomic variations.

Analysis of Bonding Characteristics of Ag-System Brazing Filler Metal (은계 필러메탈 브레이징 접합부의 특성 분석)

  • Soon-Gil Lee;Hwa-In Lee;Jin-Oh Son;Gwang-Il Ha;Bon-Heun Koo
    • Korean Journal of Materials Research
    • /
    • v.33 no.5
    • /
    • pp.214-221
    • /
    • 2023
  • As a filler metal for lowering the melting point of Ag, many alloy metal candidates have emerged, such as cadmium, with zinc, manganese, nickel, and titanium as active metals. However, since cadmium is known to be harmful to the human body, Cd-free filler metals are now mainly used. Still, no study has been conducted comparing the characteristics of joints prepared with and without cadmium. In addition, studies have yet to be conducted comparing the typical characteristics of brazing filler metals with special structures, and the joint characteristics of brazing filler metals with available frames. In this study, the characteristics of junctions of silver-based intercalation metals were compared based on the type of filler metal additives, using a special structure, a filler metal sandwich structure, to protect the internal base metal. The general filler metal was compared using the structure, and the thickness of the filler metal according to the thickness was reached. A comparison of the characteristics of the junction was conducted to identify the characteristics of an intersection of silver-based brazing filler metal and the effect on joint strength. Each filler metal's collective tensile strength was measured, and the relationship between joint characteristics and tensile joint strength was explored. The junction was estimated through micro strength measurement, contact angle measurement with the base metal when the filler metal was melted, XRD image observation, composition analysis for each phase through SEM-EDS, and microstructure phase acquisition.

Long-Term Extrinsic Uniformity Analysis of Gamma Cameras (감마카메라의 중장기 외인성 균일도 분석)

  • Yoon-Jae Kim;Woo-Young Jung;Dong-Hoon Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.36-41
    • /
    • 2023
  • Purpose The long-term trend of extrinsic uniformity by type of gamma camera was analyzed, and the factors affecting uniformity were investigated. Based on this, the purpose was to predict the life of the gamma camera, pay attention to factors that affect uniformity, and obtain better quality images. Materials and methods Four of the gamma cameras in operation at a senior general hospital in Seoul were selected and the trend of extrinsic uniformity from the first operation date to the present was analyzed. In order to minimize various factors affecting uniformity, a detailed analysis was conducted by calculating the monthly and annual average of the uniformity values. Results Two Symbia E gamma cameras from SIEMENS, one Symbia Evo Excel gamma camera, and one Symbia Intevo16 gamma camera were selected and analyzed. The uniformity of Symbia E1 (2012 warehousing) changed unevenly, and the uniformity of Symbia E2 (2014 warehousing) changed according to the replacement cycle of 57Co sheet sources. The uniformity of Symbia Evo Excel (received in 2017) and Symbia Intevo 16 (received in 2017) was constant compared to Symbia E. Conclusion The extrinsic uniformity of the gamma camera gradually increased over time. However, there was a difference in uniformity for each type of gamma camera, and there was a change in uniformity in which the cause could not be accurately identified. In order to improve the quality of the image, it is necessary to periodically check changes in uniformity and minimize factors that affect uniformity.

  • PDF

A Study on the Use of Haar Cascade Filtering to check Wearing Masks and Fever Abnormality (Haar Cascade 필터링을 통한 마스크 착용 여부와 발열 체크)

  • Kim, Eui-Jeong;Kim, In-Jung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.474-477
    • /
    • 2021
  • Recently, in order to prevent the proliferation of COVID-19, which began in earnest in 2020, an increasing number of places have been measuring the temperature and required to wear a mask. However, as wearing a mask and checking the temperature are typically measured directly by a person or by a single individual positioned in front of the machine, standards may vary based on the person's manual measurement method, wasting workforce. While standing in front of a device often measures the maximum temperature of the face, the standard of fever is also unclear. Both approaches can create bottleneck situations when checking large numbers of people. Furthermore, it is unable to conduct periodic measurements and tracking because the measuring machines are generally put only at the entrance. Thus, this study suggests a method for preventing the spread of infectious diseases by automatically identifying and displaying unmasked people and those with fever in real-time using a general camera, a thermal imaging camera, and an artificial intelligence algorithm.

  • PDF

Radio and Senior Generation: Focused on Radio Program for Senior (라디오와 노인: 라디오 노인 대상 프로그램을 중심으로)

  • Hong, Myungshin
    • 한국노년학
    • /
    • v.30 no.4
    • /
    • pp.1329-1344
    • /
    • 2010
  • This study is intended to find out how production people have been creating senior radio program. For this purpose, the study set up the three research questions and employed in-depth interviews with ten production people: First, production people find out senior radio listeners who have been very royal attendance of the program for a long time. And they examined senior listeners prefer to listen about health care, information about elderly life and singing contest. They have been made para-social interaction with master of ceremonies (MC). Second, unlike other radio program, the senior radio program has concentrated on the radio station's image and public interest rather than financial profit and viewing rate. Normally, it was known that radio program for senior used carried on break of the day. But some program has been broadcasted on prime time in the afternoon. Target audience of senior radio program has been expanded over the forties and the fifties from sixties. Thirdly, in general the role of producer is critically important to produce program. However, MC and scriptwriter are far more experienced and specialized on the field than producer in radio program for senior.

Postoperative Imaging of Rotator Cuff Tear (회전근개 파열의 수술 후 영상)

  • Min Hee Lee;Hee Jin Park;Ji Na Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1388-1401
    • /
    • 2021
  • Postoperative imaging of the rotator cuff may be performed routinely, even if pain or disability develops after surgery or if there are no symptoms. Postoperative images are obtained through MRI or US, and the purpose is to confirm the integrity of the restored tendon in general. Postoperative MRI has a relatively poor diagnostic accuracy compared to that of preoperative images because various materials used in surgeries deteriorate the image quality. US can dynamically check the condition of the restored tendon and avoid artifacts from the surgical instruments used for recovery. Although imaging findings are not always consistent with the clinical symptoms or prognosis, sub-deltoid fluid retention is more important for pain and functional recovery than the thickness of the reconstructed tendon. Strain elastography can also be a useful method for predicting the prognosis.

Reducing error rates in general nuclear medicine imaging to increase patient satisfaction (핵의학 일반영상 검사업무 오류개선 활동에 따른 환자 만족도)

  • Kim, Ho-Sung;Im, In-Chul;Park, Cheol-Woo;Lim, Jong-Duek;Kim, Sun-Geun;Lee, Jae-Seung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.295-302
    • /
    • 2011
  • To n the field of nuclear medicine, with regard to checking regular patients, from the moment they register up to the doctor's diagnosis, the person in charge of the checks can find errors in the diagnosis, reexamine, reanalyze the results or save images to PACS. Through this process, the results obtained from the readings are delayed due to checks and additional tests which occur in hospitals, causing patient satisfaction and affected reliability. Accordingly, the purpose is to include visual inspection of the results to minimize error, improve efficiency and increase patient satisfaction. Nuclear medicine and imaging tests from examines at Asan Medical Center, Seoul, from March 2008 to December 2008, were analyzed for errors. The first stage, from January 2009 to December 2009, established procedures and know-how. The second stage from January 2010 until June 2010 conducted Pre-and Post-filtering assessment, and the third stage from July 2010 until October 2010 consisted of cross-checks and attaching stickers and comparing error cases. Of 92 errors, the 1st, 2nd and 3rd stage had 32 cases, and there were 46 cases after the 4th stage, with the overall errors reduced by 74.3% from 94.6%. In the field of general nuclear medicine, where various kinds of checks are performed according to the patient's needs, analysis, image composition, differing images in PACS, etc, all have the potential for mistakes to be made. In order to decrease error rates, the image can continuously Cross-Check and Confirm diagnosis.