• 제목/요약/키워드: general electric facility

검색결과 19건 처리시간 0.03초

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제19권6호
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.

A Study of Industrial Patients from Selected General Hospitals in the Kyung Pook and Taegu City Areas (일부지역 산업재해환자 실태 연구 -대구, 경북지역 일부 종합병원 중심으로-)

  • 허춘복;남철현
    • Journal of Environmental Health Sciences
    • /
    • 제17권2호
    • /
    • pp.78-94
    • /
    • 1991
  • The purpose of this study is to research the actual conditions of industrial accident patients and to produce worker satisfaction and a rational and effective counter measure pain. Direct interviews with 179 cases (in and out patients) were carried out during a three month period from April to July 1990, at six hospitals two general hospitals Sun Lin and Sung Mo in Po Hang, and four general hospitals in Taegu Kyung Pook University Hospital, Dong San Medical Center, Young Nam Medical Center and Catholic Hospital. The results of this study are summarized as follows: 1. Among the 179 cases, 51.6 % were male and 48.4 % were female. The two largest age groups were 30~39, 31.8 % and 20~29, 27.4 %. Among the 179 cases, 51.6% were married, the largest family number was 2 to 3, 41.1% and 4 to 5, 25.6%. Educationally, graduation from high school was the largest group, 46.4% among the patients, followed by middle school and primary school. The largest group income level was from 40~69만원, 45.2%. The largest group of patients who worked over 50 hrs. a week was 52.0%. The largest group of patients who worked less than 1 year was 44.7%, of the patients in work places of less than 100 people, 60.3% were injured and in work places of 100~299 people, 20.1% were injured. In manufacturing, the lagest group injured was 55.3%, the next group was transport, stroage, communication. The largest group of production workers injured was 40.2%. 2. The cause of injury in the largest group was facility problems, 33.5%. The next group was unsafe habits, 30.2% a lack of safety knowledge, 17.9% and insufficient supervision, 12.3%. The 30~39 year age group was head the highest number of injuries, 40.4% work places with more than 10 yeras of work, 44.4% work palces with more than 1000 people, 56.3% and mining accidents, 80.0%. Among these groups the highest cause of injury was due to facility problems. 3. The accident pattern showed machinery injuries 28.5% as the largest group, followed by falls & falling objects 17.3%, fire & electric 15.1%, struke by an object 14.5%, followed by overaction and vehicular accidents. The accident pattern showed 46.4 % among workers over the 50 year age group, workers in the 5~10 year group, 50.0 % places employing more than 1000 workers, 35.3 % : construction 73.7%, and construction workers 57.1%, among these fall & falling objects caused the greatest number of injuries. 4. The largest group of injuries was fractures 54.8%, trauma 14.5%, amputation 11.7%, open wound, and burns. The largest number of fractures occurred in people in the 30~39 year age group, 63.2 % over 10 years of work, 55.6% in work places of 300~400 people, 63.6% construction 63.2% and general workers 57.2 %. 5. The largest group of injuries was upper extremity 45.3%, lower extremity 24.0%, trunk 18.5 % and head or neck 12.2%. Of these groups, upper extremity injuries were the highest in those less 20 years old 75.0%, less than 1 years of work 59.5%, in work places of 500~999 people 60.0%, manufacturing 56.6 % and production workers 55.6%. 6. Periods of injury showed 34 people injured in September, to be the largest followed by October, 32 August, 22 people July, 19 people and the lowest December, 2 people. During the week, Friday had the largest group injured, 35 people followed by Saturday, 26 people and the lowest was Wednesday, 17 people, During the day 1400 hours had the largest group injured, 38 people followed by 800 hours, 31 people. 7. On a basis of 5 as the highest mark, the average, according to worker satisfaction showed facility safety 3.55, work environment 3.47, income 3.44, job 3.21 and treatment 2.98. 8. The correlation between general characteristics and injury showed that age was directly correlated to the duration of work(r=.2591) p<0.01, age was directly correlated to industry (r=2311) p<0.01, and the duration was directly correlated to occupation(r =.4372) p<0.001.

  • PDF

A Study of Industrial Patients from Selected General in the Kyung Pook and Taegu City areas (일부지역 산업재해환자 실태 조사 연구 -대구${\cdot}$경북지역 일부 종합병원 중심으로-)

  • Huh, Choon-Bok
    • The Journal of Korean Physical Therapy
    • /
    • 제3권1호
    • /
    • pp.151-174
    • /
    • 1991
  • The purpose of this study is to research the actual conditions of industrial accident patients and to produce worker satisfaction and a rational and effective counter measure plan. Direct interviews with 179 cases (in and out patients) were carried out during a three month period from April to July 1990, at six hospitals : two general hospitals Sun Lin and Sung Mo in Po Hang, and four general hospitals in Taegu : Kyung pooh University Hospital, Dong San Medical Center, Young Nam Medical Center and Catholic Hospital. The results of this study are summarized as fellows : 1. Among the 179 cases, $51.6\%$ were male and $48.4\%$ were female. The two largest age groups were 30-39, $31.8\%$ and 20-29, $27.4\%$. Among the 179 cases, $51.6\%$ were married, the largest family number was 2 to 3, $41.1\%$ and 4 to 5, $25.6\%$. Educationally, graduation from high school was the largest group, $46.4\%$ among ,the patients, followed by middle school and primary school. The largest group income level was from 40-69 만원, $45.2\%$. The largest group of patients who worked over 50 hrs. a week was $52.0\%$. The largest group of patients who worked less than 1 year was $44.7\%$, of the patients in work places of less than 100 people, $60.3\%$ were injured and in work places of 100-299 people, $20.1\%$ were injured. In manufacturing, the largest group injured was $55.3\%$, the next group was transport, storage, communication. The largest group of production workers injured was $40.2\%$. 2. The cause of injury in the largest group was facility problems, $33.5\%$. The next group was unsafe habits, $30.2\%$ ; a lack of safety knowledge, $17.9\%$ ; and insufficient supervision, $12.3\%$. The 30-39 year age group head the highest number of injuries, $40.4\%$ ; work places with more than 10 years of work, $44.4\%$ ; work places with more than 1000 people, $56.3\%$ and mining accidents, $80.0\%$. Among. these groups the highest cause of injury was due to facility problems. 3. The accident pattern showed machinery injuries $28.5\%$ as the largest group, followed by falls & falling objects $17.3\%$, fire & electric $15.1\%$, strucke by an object $14.5\%$, followed by overaction and vehicular accidents. The accident pattern showed $46.4\%$ among workers over the 50 year age group, workers in the 5-10 year group, $50.0\%$ ; places employing more than 1000 workers, $35.3\%$ ; construction $73.7\%$, and construction workers $57.1\%$, among these fall & falling objects caused the greatest number of injuries. 4. The largest group of injuries was fractures $54.8\%$, trauma $14.5\%$, amputation $11.7\%$, open wound, and burns. The largest number of fractures occurred in people in the 30-39 year age group, $63.2\%$ : over 10 years of work, $55.0\%$ ; in work places of 300-490 people, $63.6\%$ ; construction $63.2\%$ and general workers $57.2\%$. 5. The largest group of injuries was upper extremity $45.3\%$, lower extremity $24.0\%$, trunk $18.5\%$ and head or neck $12.2\%$. Of these groups, upper extremity injuries were the highest in those less than 20 years old $75.0\%$, less than 1 year or work $59.5\%$, in work places of 500-999 people $60.0\%$, manufacturing $56.6\%$ and production workers $55.6\%$. 6. Periods of injury showed 34 people injured in September, to be the largest followed by October, 32 ; August, 22 people : July, 19 people and the lowest December, 2 people. During the week, Friday had the largest group injured, 35 people ; followed by Saturday, 26 people and the lowest was Wednesday, 17 people, During the day 1400 hours had the largest group injured, 38 people ; followed by 800 hours, 31 people. 7. On a basis of 5 as the highest mark, the average, according to worker satisfaction showed facility safety 3.55, work environment 3.47, income 3.44, job 3.21 and treatment 2.98. 8. The correlation between general characteristics and injury showed that age was directly correlated to the duration of work (r=2591) p<0.01, age was directly correlated to industry (r=2311) p<0.01, and the duration was directly correlated to occupation (r=4372) p<0.001.

  • PDF

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • 제10권4호
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

Development of Gas Leak Detecting System Based on Quantum Technology (양자기술기반 가스 누출 감지 시스템 개발)

  • Kwon, Oh Sung;Park, Min Young;Ban, Changwoo
    • Journal of the Korean Institute of Gas
    • /
    • 제25권5호
    • /
    • pp.57-62
    • /
    • 2021
  • Gas is an energy source widely used in general households and industrial sites, and is also a process material widely used in petrochemical and semiconductor processes. However, while it is easy to use, it can cause large-scale human damage due to leakage, explosion, and human inhalation. Therefore, a gas facility safety management solution that can be safely used at home and industrial sites is essential. In particular, the need to develop advanced gas safety solutions is emerging as gas facilities are aging. In this paper, a technology was developed to measure the presence and concentration of gas leaks from a distance by irradiating photons, the minimum energy unit that can no longer be divided into gas facilities, and analyzing the number of reflected photons. This overcomes technical limitations such as short detection distance and inability to detect fine leaks, which are the limitations of conventional electric/chemical gas sensors or infrared-based gas leak detectors.

An Analysis of Determinants of Health Knowledge, Attitude and Practice of Housewives in Korea (한국부인의 보건지식, 태도 및 실천에 영향을 미치는 제요인분석)

  • 남철현
    • Korean Journal of Health Education and Promotion
    • /
    • 제2권1호
    • /
    • pp.3-50
    • /
    • 1984
  • The levels of health knowledge, attitude and practice of housewives considerably effect to the health of households, communities and the nation. This study was designed to grasp the levels of health knowledge, attitude and practice of houswives and analyse the various factors effecting to health in order to provide health education services as well as materials for effective formulation and implementation of health policy to improve the health of the nation. This study has been conducted through interviews by trained surveyers for 4,281 housewives selected from 4,500 households throughout the country for 40 days during July 11-August 20, 1983. The results of survey were analysed by stepwise multiple regression and path analysis are summarized as follows; 1. Based on the measurement instrument applied to this study, the levels of health knowledge, attitude and practice of housewives were extremely low with 54.5 points out of 100 points in full. Higher level with 72 points and above was approximately 21 percent and lower level with 39 points and below was approx. 24 percent. The middle level was approx. 55 percent. In order to implement health programs successively, health education should be more strengthened and to improve the level of health knowledge, attitude and practice (KAP) of the nation, political consideration as a part of spiritual reformation must be concentrated on health. 2. The level of health knowledge indicated the highest points with 57.3 the level of attitude was the second with 55.0 points and the practice level was the lowest with 50.0 point. Therefore, planning and implementation of health education program must be based on the persuasion and motivation that health knowledge turn into practice. 3. Housewives who had higher level of health knowledge, showed their practice level was relatively lower and those who had middle or low level of it practice level was the reverse. 4. Correlations among health knowledge, attitude and practice (KAP) were generally higher and statistically significant at 0.1 percent level. Correlation between total health KAP level and health knowledge was the highest with r=.8092. 5. Health KAP levels showed significant differences according to the age, number of children, marital status, self-assessed health status and concern on health of the housewives interviewed (p<0.001) 6. Health KAP levels also showed significant differences according to the education level, economic status, employment before marriage and grown-up area of the housewives interviewed. (p<0.001) 7. Heath KAP levels showed significant differences according to health insurance benificiary and the existence of patients in the family. (p<0.001). 8. Health KAP levels showed significant differences according to distance to government organizations, schools, distance to health facilities, telephone possession rate, television possession rate, newspaper reading rate and activities of Ban meeting and Women's club. (p<0.001) 9. Health KAP levels showed significant differences according to electric mass communication media such as television, radio and village broadcasting etc. and printed media such as newspaper, magazine and booklets etc., IEC variables such as individual consultation and husband-wife communication, however, there was no significance with group training. 10. Health KAP of the housewives showed close correlation with personal characteristics variables, i.e., education level (r=.5302), age (r=-.3694) grown-up area (r=.3357) and employment before marriage. In general, correlation of health knowledge level was higher than the levels of attitude or practice. In case of health concern and health insurance, correlation of practice level was higher than health knowledge level. 11. Health KAP levels showed higher correlation with community environmental characteristics, Ban meeting and activity of Women's club, however, no correlation with New-village movement. 12. Among IEC variables, husband-wife communication showed the highest correlation with health KAP levels and printed media, electric mas communication media and health consultation in order. Therefore, encouragement of husband-wife communication and development of training program for men should be included in health education program. 13. Mass media such as electric mass com. and printed media were effective for knowledge transmission and husband-wife communication and individual consultation were effective for health practice. Group training was significant for knowledge transmission, however, but not significant for attitude formation or turning to health practice. To improve health KAP levels, health knowledge should be transmitted via mass media and health consultation with health professionals and field health workers should be strengthened. 14. Correlation of health KAP levels showed that knowledge level was generally higher than that of practice and recognized that knowledge was not linked with attitude or practice. 15. The twenty-five variables effecting health KAP levels of housewives had 41 per cent explanation variances among which education level had great contribution (β=.2309) and electric mass com. media (β=.1778), husband-wife communication (β=.1482), printed media, grown-up area, and distance to government organizations in order. Variances explained (R²) of health KAP were 31%, 15%, and 30% respectively. 16. Principal variables contributed to health KAP were education level (β=.12320, β=.1465), electric mass comm. media (β=.1762, β=.1839), printed media, (β=.1383, β=.1420) husband-wife communication (β=.1004, β=.1067), grown-up area and distance to government organizations, in order. Since education level contributes greatly to health KAP of the housewives, health education including curriculum development in primary, middle and high schools must be emphasized and health science must be selected as one of the basic liberal arts subject in universities. 17. Variences explained of IEC variables to health KAP were 19% in total, 14% in knowledge, 9% in attitude, and 10% in health practice. Contributions of IEC variables to health KAP levels were printed media (β=.3882), electric mass comm media (β=.3165), husb-band wife com. (β=.2095,) and consultation on health (β=.0841) in order, however, group training showed negative effect (β=-.0402). National fund must be invested for the development of Health Program through mass media such as TV and radio etc. and for printed materials such as newspaper, magazines, phamplet etc. needed for transmission of health knowledge. 18. Variables contributed to health KAP levels through IEC variables with indirect effects were education level (Ind E=0.0410), health concern (Ind E=.0161), newspaper reading rate (Ind E=.0137), TV possession rate and activity of Ban meeting in order, however, health facility showed negative effect (Ind E=-.0232) and other variables showed direct effect but not indirect effect. 19. Among the variables effecting health KAP level, education level showed the highest in total effect (TE=.2693) then IEC (TE=.1972), grown-up city (TE=.1237), newspaper reading rate (TE=.1020), distance to government organization (TE=.095) in order. 20. Variables indicating indirect effects to health KAP levels were; at knowledge level with R²=30%, education level (Ind E=.0344), newspaper reading rate (Ind E=.0112), TV possession rate (Ind E=.0689), activity of Ban meeting (Ind E=.0079) in order and at attitude level with R²=13%, education level (Ind E=. 0338), activity of Ban meeting (Ind E=.0079), and at practice level with R²=29%. education level (Ind E=.0268), health facility (Ind E=.0830) and concern on health (Ind E=.0105). 21. Total effect to health KAP levels and IEC by variable characteristics, personal characteristics variables indicated larger than community characteristics variables. 22. Multiple Correlation Coefficient (MCC) expressed by the Personal Characteristic Variable was .5049 and explained approximately 25% of variances. MCC expressed by total Community environment variable was .4283 and explained approx. 18% of variances. MCC expressed by IEC Variables was .4380 and explained approx. 19% of variances. The most important variable effected to health KAP levels was personal characteristic and then IEC variable, Community Environment variable in order. When the IEC effected with personal characteristic or community characteristic, the MCC or the variances were relatively higher than effecting alone. Therefore it was identified that the IEC was one of the important intermediate variable.

  • PDF

Seismic Fragility Evaluation of Cabinet Panel by Nonlinear Time History Analysis (비선형시간이력해석을 이용한 수배전반의 지진취약도 도출)

  • Moon, Jong-Yoon;Kwon, Min-ho;Kim, Jin-Sup;Lim, Jeong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제19권2호
    • /
    • pp.50-55
    • /
    • 2018
  • Earthquakes are almost impossible to predict and take place in a short time. In addition, there is little time to take aggressive action when an earthquake occurs. Therefore, there are more casualties and property damage than with other natural disasters. Recently, earthquakes have been occurring all over the world. As the number of earthquakes increase, studies on the safety of structures are being carried out. On the other hand, there are few studies on the electric facilities, which are relatively non - structural factors. Currently, electrical equipment in Korea is often not designed for earthquake safety and is quite vulnerable to damage when an earthquake occurs. Therefore, in this study, modeling was conducted through ABAQUS similar to an actual cabinet panel and 3D dynamic nonlinear analysis was performed using a natural seismic. According to seismic zone I and normal ground rock conditions of the power transmission and transmission facility seismic design practical guide, the maximum response acceleration of the performance level was 0.157g. In this study, however, it was not safe to reach the limit state of 30% of the analytical result at 0.1g for the general cabinet panel. From the results, the seismic fragility curve was derived and analyzed. The derived seismic fragility curve is presented as a quantitative basis for determining the limit state of the cabinet panel and can be utilized as basic data in related research.

The Profile of Milling Plants in Korea (우리나라 양곡가공공장의 현황분석)

  • 정창주;금동혁;강화석
    • Journal of Biosystems Engineering
    • /
    • 제3권1호
    • /
    • pp.47-63
    • /
    • 1978
  • This study was conducted to obtain a basic information necessary to assess present rice milling technology in Korea The profiles for milling plants was analyzed by survey work.For the private custom-work mills, which process about 80 percent of domestic rice consumption ,their actual milling test for the identical samples as used for filed mills was conducted. Two rice varieties Japonica and Tongil-type were associated with the experiments. The results are summarized as follows: 1. Analyses for private custom-work mills showed their general aspects as; about 91 percent of the mills belonged to an individual owner ship ; more than 93 percent of the mills was established earlier than 1950 ; about 80 percent of the mills was powered with electric motor; mills having less than two employees were about 75 percent; about 45 percent of the mills provided for warehouse in storing customers cereal grains. 2. The polishers installed in 1,255mills within the surveyed area (7 counties) have been supplied by 44 different domestic manufacturers ;in but about 60 percent of which was supplied by 6major manufacturers. The polishers could be classified into two categories in terms of principles of their polishing actions ;jet-pearler and friction types. About 51 percent of the mills was equipped with the former which has been recognized as giving greater milling recovery than the friction types. 3. Reason for owners of private mills to supplement new machines was due mainly to pgrading their mills to meet the requirements that established by the Government. However, about 60 percent of the mill owners intended to replace with new pearler by their own needs to meet with new high yielding varieties. 4. Processing systems of each previate rice mills surveyed could be classified into three categories, depending upon whether the systems posessed such components as precleaner and paddy separator or not. Only 36.7 percent of mills was installed with both precleanr ad paddy seperrator, 5.0 percent of mills did have neither percleaner nor paddy seperator, and rest of them equipped only one of the two. Hence,it is needed for about 63% of rice miils to be supplemented with these basic facilities to meet with the requirements for the standaized system. 5. Actual milling capacity measured at each field rice mills was shown a wide variation, having range from about 190 to 1,210 kg/hr. The percentages of mills classified according to daily milling capacity based on this hourly capacity were 24.3% for the capacity less than 3 M/T a day; 20.0% for 3-4 M/T; 15.6% for 4-5 M/T; 6.7% for 5-6 M/T; 22.3% for 6-7 M/T; and 11.0% for more than 7 M/T a day. 6. Actual amount of rice processed was about 310 M/T a year in average. About 42% of total milled rice was processed during October to Decembear, which formed a peak demand period for rice mills. The amount of rice milled during January to May was relatively small, but it had still a large amount compared to that during June to September. 7. Utilization rate of milling facility, i. e., percentage of the actual amount of milled rice to the capacity of rice mills, was about 18% on the year round average, about 41% in the peak demand season, and about 10% during June to September. Average number of operating days for mills surveyed was about 250 days a year, and about 21 days a month. 8. Moisture contents of paddy at the time of field mill tests were ranged 14.5% to 19.5% for both Japonica and Tong-i] varieties, majority of paddy grains having moisture level much higher than 1530. To aviod potential reduction of milling recovery while milling and deterioration of milled rice while storage due to these high grain mJisture contents, it may be very important for farmers holding rice to dry by an artificial drying method. 9. Milling recovery of JapJnica varieties in rice mills was 75.0% in average and it was widely ranged from 69.0% to 78.0 % according to mills. Potential increase in milJing recovery of Japonica variety with improvement of mill facilities was estimated to about 1.9%. On the other hand, milling recovery of Tong-il varieties in the field mill tests was 69.8% in average and it ranged from 62% to 77 %, which is much wider than that of Japonica varieties. It is noticed that the average milling recovery of Tong-il variety of 69.8% was much less than that of the Japonica-type. It was estimated th3.t up to about 5.0% of milling recovery for Tong-il variety could be improved by improving the present lo'.ver graded milling technology. 10. Head rice recoveries, as a factor of representing the quality of commercial goods, of Japonica and Tong-il varieties were 65.9% and 53.8% in average, and they were widely ranged from 52% to 73% and from 44% to 65% , respectively. It was assessed that head rice recovery of Japonica varieties can be improved up 3.3% and that of Tong-il varieties by 7.0% by improving mill components and systems.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제25권6호
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.