• Title/Summary/Keyword: gauge space

Search Result 92, Processing Time 0.02 seconds

A Study of Temporal Characteristics From Multi-Dimensional Precipitation Model (다차원 강우모형의 시간적인 특성 연구)

  • Kim, Sangdan;Yoo, Chulsang;Kim, Joong-Hoon;Yoon, Yong Nam
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.6
    • /
    • pp.783-791
    • /
    • 2000
  • A multidimensional representation for precipitation, given In the theory proposed by E. Waymire et al. (1984), is used for simulating rainfall in space and time. The model produces moving storms with realistic meso-scale meteorological features in time and space. The first- and second-order statistics derived from observed JX)int gauge data were used to estimate the model parameters based on the Nelder-Mead algorithm of optimization. Then twelve-year traces of rainfall intensities at fixed gage stations were generated at intervals of 1 hours. First- and second-order statistics are evaluated from the above series, which are used for estimating the parameters of one dimensional model of temporal rainfall at a point. As a result from the comparisons of one dimensional model parameters used observed and generated data from multidimensional model, we found that the multidimensional rainfall model generated visually realistic spatial patterns of rainfall as well as realistic temporal hyetographs of rainfall at a point. point.

  • PDF

Healing of the bone around pure titanium implants without primary bone contact (초기 골 접촉이 없는 순수 티타늄 임프란트 주위 골의 치유반응)

  • Ahn, Jae-Hyun;Kim, Heung-Joong;Park, Joo-Cheol;Han, Kyung-Yoon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.233-249
    • /
    • 1999
  • Primary fixation is one of the most important factor in establishing adequate osseointegration between implant and bone. To evaluate the initial healing response of bone around implants without primary bone contact, this study was designed to create considerable space between implant and bone in 5 mongrel dogs, about 1-year old. After 3 holes of 6.0mm in diameter were prepared at the femur neck of the dogs, commercially pure titanium thread type implants(STERI-$OSS^{(R)}$), 8mm in length and 3.8mm, 5.0mm and 6.0mm in diameter, were inserted. Implants were supported by only nonresorbable membrane($Teflon^{(R)}$), and the penetration of upper soft tissue into the gap was inhibited by it. The each implant was positioned in the center of the drilled hole. 9 implants with different diameters were inserted in 3 dogs for histologic observation, and 12 were inserted in 2 dogs for mobility test and removal torque test.Fluorescent dyes were injected in order of Doxycycline, Alizarin Red S, and Calcein at intervals of 2 weeks. At 4-, 8-, and 12-week after placement, 3 dogs were sacrificed for histologic observation, and at 8- and 12-week after placement, 2 dogs were sacrificed for mobility test using $Periotest^{(R)}$ (Simens AG, Bensheim, Germany) and torque test using Autograph AGS-1000D $series^{(R)}$(Japan). The result were as follows: 1. The wider the gap between bone and implant was, the less bone maturity was, and the later osseointegration was occurred. Trabecular direction of new bone around implant was changed from parallel to perpendicular to the implant, and the gap was filled with new bone, over time. 2. There was a decreasing tendency over time in the mobility of all implants, but the wider gap between bone and implant was, the smaller decrease of the mobility was. 3. There was a increasing tendency over time in the removal torque gauge of all implants, and the wider gap was, the smaller increase of the removal torque gauge was. The results suggest that osseointegration in case of implant without primary bone contact may be obtained by guided bone regeneration technique with prolonged healing period, but the time of second surgery should be considered carefully.

  • PDF

A experimental Feasibility of Magnetic Resonance Based Monitoring Method for Underground Environment (지하 환경 감시를 위한 자기공명 기반 모니터링 방법의 타당성 연구)

  • Ryu, Dong-Woo;Lee, Ki-Song;Kim, Eun-Hee;Yum, Byung-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.596-608
    • /
    • 2018
  • As urban infrastructure is aging, the possibility of accidents due to the failures or breakdowns of infrastructure increases. Especially, aging underground infrastructures like sewer pipes, waterworks, and subway have a potential to cause an urban ground sink. Urban ground sink is defined just as a local and erratic collapse occurred by underground cavity due to soil erosion or soil loss, which is separated from a sinkhole in soluble bedrock such as limestone. The conventional measurements such as differential settlement gauge, inclinometer or earth pressure gauge have a shortcoming just to provide point measurements with short coverage. Therefore, these methods are not adequate for monitoring of an erratic subsidence caused by underground cavity due to soil erosion or soil loss which occurring at unspecified time and location. Therefore, an alternative technology is required to detect a change of underground physical condition in real time. In this study, the feasibility of a novel magnetic resonance based monitoring method is investigated through laboratory tests, where the changes of path loss (S21) were measured under various testing conditions: media including air, water, and soil, resonant frequency, impedance, and distances between transmitter (TX) and receiver (RX). Theoretically, the transfer characteristic of magnetic field is known to be independent of the density of the medium. However, the results of the test showed the meaningful differences in the path loss (S21) under the different conditions of medium. And it is found that the reflection coefficient showed the more distinct differences over the testing conditions than the path loss. In particular, input reflection coefficient (S11) is more distinguishable than output reflection coefficient (S22).

Effect of epidural corticosteroid injection on magnetic resonance imaging findings

  • Kim, Min Soo;Jeong, Tae Yoon;Cheong, Yu Seon;Jeon, Young Wook;Lim, So Young;Kang, Seong Sik;Kim, In Nam;Chang, Tsong Bin;Seong, Hyun Ho;Hwang, Byeong Mun
    • The Korean Journal of Pain
    • /
    • v.30 no.4
    • /
    • pp.281-286
    • /
    • 2017
  • Background: Magnetic resonance imaging (MRI) of the spine is the preferred diagnostic tool for pathologic conditions affecting the spine. However, in patients receiving epidural corticosteroid injection (ESI) for treatment of spinal diseases, there is a possibility of misreading of MR images because of air or fluid in the epidural space after the injection. Therefore, we defined the characteristics of abnormal changes in MRI findings following an ESI in patients with low back pain. Methods: We reviewed the medical records of 133 patients who underwent MRI of the lumbar spine within 7 days after ESI between 2006 and 2015. All patients were administered an ESI using a 22-gauge Tuohy needle at the lumbar spine through the interlaminar approach. The epidural space was identified by the loss of resistance technique with air. Results: The incidences of abnormal changes in MRI findings because of ESI were 54%, 31%, and 25% in patients who underwent MRI at approximately 24 h, and 2 and 3 days after ESI, respectively. Abnormal MRI findings included epidural air or fluid, needle tracks, and soft tissue changes. Epidural air, the most frequent abnormal finding (82%), was observed in 41% of patients who underwent MRI within 3 days after injection. Abnormal findings due to an ESI were not observed in MR images acquired 4 days after ESI or later. Conclusions: Pain physicians should consider the possibility of abnormal findings in MR images acquired after epidural injection using the interlaminar approach and the loss of resistance technique with air at the lumbar spine.

A Spatial Statistical Approach to Residential Differentiation (I): Developing a Spatial Separation Measure (거주지 분화에 대한 공간통계학적 접근 (I): 공간 분리성 측도의 개발)

  • Lee, Sang-Il
    • Journal of the Korean Geographical Society
    • /
    • v.42 no.4
    • /
    • pp.616-631
    • /
    • 2007
  • Residential differentiation is an academic theme which has been given enormous attention in urban studies. This is due to the fact that residential segregation can be seen as one of the best indicators for socio-spatial dialectics occurring on urban space. Measuring how one population group is differentiated from the other group in terms of residential space has been a focal point in the residential segregation studies. The index of dissimilarity has been the most extensively used one. Despite its popularity, however, it has been accused of inability to capture the degree of spatial clustering that unevenly distributed population groups usually display. Further, the spatial indices of segregation which have been introduced to edify the problems of the index of dissimilarity also have some drawbacks: significance testing methods have never been provided; recent advances in spatial statistics have not been extensively exploited. Thus, the main purpose of the research is to devise a spatial separation measure which is expected to gauge not only how unevenly two population groups are distributed over urban space, but also how much the uneven distributions are spatially clustered (spatial dependence). The main results are as follows. First, a new measure is developed by integrating spatial association measures and spatial chi-square statistics. A significance testing method based on the generalized randomization test is also provided. Second, a case study of residential differentiation among groups by educational attainment in major Korean metropolitan cities clearly shows the applicability of the analytical framework presented in the paper.

Graphic system analysis on the Chil Sung Hwa(seven stars picture) (칠성화(七星畵)의 그래픽체계 분석)

  • 나윤화
    • Archives of design research
    • /
    • v.11
    • /
    • pp.22-29
    • /
    • 1995
  • I have to find standpoint of sight moulding of Chi I Sung Hwa(seven stars picture) analysis of graphic systems of a symbol sight native to our nation. And I will comprehend emotion of folkways by simple and graphic lines and colors in mathematical Grid of which ancestor had expressed in gauge moulding consciousness. This papers aim is to make a contribution to lead by on part of communication design. About structural analysis of pictorial graphic side. I) Mathematical thought of the Orient and space constitution are first basically the Orient expressed number notion of mathematics of unlimitedness and notion of zero so called space and empty second can analigize a diagonal expansion method by development of symmetry notion to basic the dual principle of the negative and positive by degrees development expressed space division method by direction notion. 2) About the proportion analysis it based the golden section globularity and in modern layout it takes vision center of position, after appointing the brow of sacred image of Chil Sung Hwa as center point of proportion and applied to the point proportion and so analigized the posibility of established. Rule in union of each elements and rule of forms about picture image. 3) Mathematical structure analysis to search a unified principle at the balanced arrangement and rule of forms it analigized the standard the rule of forms. it analigized the standard the rule of forms to body module of basic movement of protagonist and follower above basic forms of grid that is the basis of design system.

  • PDF

Bactericidal and wound disinfection efficacy of nanostructured titania

  • Azad, Abdul-Majeed;Aboelzahab, Asem;Goel, Vijay
    • Advances in materials Research
    • /
    • v.1 no.4
    • /
    • pp.311-347
    • /
    • 2012
  • Infections are caused due to the infiltration of tissue or organ space by infectious bacterial agents, among which Staphylococcus aureus bacteria are clinically most relevant. While current treatment modalities are in general quite effective, several bacterial strains exhibit high resistance to them, leading to complications and additional surgeries, thereby increasing the patient morbidity rates. Titanium dioxide is a celebrated photoactive material and has been utilized extensively in antibacterial functions, making it a leading infection mitigating agent. In view of the property amelioration in materials via nanofication, free-standing titania nanofibers (pure and nominally doped) and nanocoatings (on Ti and Ti6Al4V implants) were fabricated and evaluated to assess their efficacy to mitigate the viability and growth of S. aureus upon brief (30 s) activation by a portable hand-held infrared laser. In order to gauge the effect of exposure and its correlation with the antibacterial activities, both isolated (only titania substrate) and simultaneous (substrate submerged in the bacterial suspension) activations were performed. The bactericidal efficacy of the IR-activated $TiO_2$ nanocoatings was also tested against E. coli biofilms. Toxicity study was conducted to assess any potential harm to the tissue cells in the presence of photoactivated materials. These investigations showed that the photoactivated titania nanofibers caused greater than 97% bacterial necrosis of S. aureus. In the case of titania-coated Ti-implant surrogates, the bactericidal efficacy exceeded 90% in the case of pre-activation and was 100% in the case of simultaneous-activation. In addition to their high bactericidal efficacy against S. aureus, the benignity of titania nanofibers and nanocoatings towards tissue cells during in-vivo exposure was also demonstrated, making them safe for use in implant devices.

A STUDY ON THE ROOT CANAL MORPHOLOGY CHANGE BY NICKEL-TITANIUM AND STAINLESS STEEL FILE INSTRUMENTATION USING COMPUTERIZED TOMOGRAPHY (Nickel-Titanium file과 Stainless steel file을 이용한 근관형성시 컴퓨터 단층촬영사진상의 근관형태 변화에 관한 연구)

  • So, Mun-Seop;Im, Mi-Kyung;Lee, Keon-Il;Lee, Yong-Keun;Lee, Su-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.659-669
    • /
    • 1997
  • The goals of root canal instrumentation are complete debridement of pulp tissue, removal of microbes and affected dentin, and proper cleaning and shaping of the root canal space before obturation. Instrumentation with stainless steel files has been shown to produce undesirable results in canals, regardless of the improved technique or modified file type used. Nickel-Titanium(Ni-Ti) alloy has been shown to be exceptionally elastic, having a lower bending moment and lower permanent set after torsion, compared with similar gauge stainless steel. The purpose of this study was to evaluate the change of root canal prepared by Ni-Ti rotary and stainless steel instruments. Thirty-four single rooted teeth of similar shape and canal size were divided into three groups. The teeth were scanned by computed tomography before instrumentation. In group 1, canals were instrumented using a step-back technique with K-file. In group 2, canals were prepared with K-flex file using the same technique as group 1. Group 3 was prepared with nickel-titanium(Ni-Ti) rotary instrument using a manufacture's instruction. Instrumented teeth were again scanned using computed tomography, and reformated images of the uninstrumented canals were compared with images of the instrumented canals. K-flex file and Ni-Ti file caused significantly less canal transportation than K-file in the 8mm root canal section from the apex(p<0.05). K-flex file and Ni-Ti file produced more centered canal preparation than K-file in the 2mm section(p<0.05). Ni-Ti file maintained more precisely the center of the canal than K-flex file in the 10mm section (p<0.05). There was no difference in the removed volume of canals among each groups.

  • PDF

The Effect of Continuous Epidural Block in Lumbago and Sciatica (요통, 좌골 신경통 환자에서의 지속적 경막외 차단의 효과)

  • Kim, Seok-Hong;Lim, Kyung-Im;Sohn, Hang-Soo;Park, Hack-Ju
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.279-285
    • /
    • 1995
  • Extradural block is a form of treatment described as early as the beginning of the present centuries. It has since had positive criticism from a number of authors in different countries. Epidural injections of steroids with or without local anesthetic have become an occasional method of conservative treatment in sciatica & lumbago, especially in acute case. We assess the results of continuous epidural block with steroids and local anesthetics in sciatica & lumbago. From July 1994 to June 1995, we treated 46 case of lumbago and sciatica using continuous epidural block with steroids and local anesthetics. After placement of 17-Gauge Tuohy needle in the epidural space by the technique of loss of resistance, 0.25% bupivacaine 5 cc and triamcinolone 40 mg was administered and then epidural catheter was placed and connected to multiday infusor(Paragon) using 1% lidocaine with continuous infusion rate of 1 ml/hour. Usually, the catheter was removed after 1~2 weeks and then treated with the physical therapy. At the time of patient's discharge, 69.5% of all cases showed excellent or good results. Of particular note, 26 of the 46 cases were followed up by telephone. At present, in using Of particular note, 26 of the 46 cases were followed up by telephone. At present, in using continuous epidural block procedure, a relief in symptoms showed in 65.5% of these 26 cases. Continuous epidural block provides shortening of the recovery time from pain, avoidance of long period bed rest and early physical therapy and exercise. Therefore, continuous epidural block is simple and safe in the treatment of lumbago and sciatica, especially in acute phase.

  • PDF

Measuring the Degree of Content Immersion in a Non-experimental Environment Using a Portable EEG Device

  • Keum, Nam-Ho;Lee, Taek;Lee, Jung-Been;In, Hoh Peter
    • Journal of Information Processing Systems
    • /
    • v.14 no.4
    • /
    • pp.1049-1061
    • /
    • 2018
  • As mobile devices such as smartphones and tablet PCs become more popular, users are becoming accustomed to consuming a massive amount of multimedia content every day without time or space limitations. From the industry, the need for user satisfaction investigation has consequently emerged. Conventional methods to investigate user satisfaction usually employ user feedback surveys or interviews, which are considered manual, subjective, and inefficient. Therefore, the authors focus on a more objective method of investigating users' brainwaves to measure how much they enjoy their content. Particularly for multimedia content, it is natural that users will be immersed in the played content if they are satisfied with it. In this paper, the authors propose a method of using a portable and dry electroencephalogram (EEG) sensor device to overcome the limitations of the existing conventional methods and to further advance existing EEG-based studies. The proposed method uses a portable EEG sensor device that has a small, dry (i.e., not wet or adhesive), and simple sensor using a single channel, because the authors assume mobile device environments where users consider the features of portability and usability to be important. This paper presents how to measure attention, gauge and compute a score of user's content immersion level after addressing some technical details related to adopting the portable EEG sensor device. Lastly, via an experiment, the authors verified a meaningful correlation between the computed scores and the actual user satisfaction scores.