• Title/Summary/Keyword: gauge group

Search Result 177, Processing Time 0.026 seconds

Anti-inflammatory Effect on Desmodii Herba Pharmacopuncture at $KI_{10}$ on Nephritis in Rats (음곡 금전초약침이 LPS로 유도된 흰쥐의 신장염에 미치는 영향)

  • Yoon, Kwang-Shik;Kang, Jae-Hui;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.28 no.3
    • /
    • pp.43-54
    • /
    • 2011
  • Objectives : This study was designed to evaluate the effects of Desmodii herb pharmacopuncture (DH-HA) at $KI_{10}$(Umgok) on nephritis induced by lipopolysaccharide(LPS) in rat. Methods : Rats were injected LPS to induce nephritis. DH-HA group was treated with DH-HA at $KI_{10}$ three times for a week, NP group with 26 gauge needle, saline group with normal saline. To evaluate the effects of DH-HA at $KI_{10}$ on nephritis in rats, RBC, WBC, neutrophil in blood, TNF-a, CINC-1 in serum, creatinine and total protein in urine, renal TNF-a, renal MPO were measured and renal tissue was analyzed. Results : WBC in blood, CINC-1 in serum, renal MPO significantly reduced in DH-HA group. Conclusions : DH-HA at $KI_{10}$ is effective for nephritis in LPS-induced rats. Therefore, DH-HA at $KI_{10}$ may be useful for nephritis in clinical field.

The Effects of $\alpha$-Wave Music and Art Appreciation on Hand Function in Patient with Stroke (알파파 음악과 미술감상이 뇌졸중 환자의 손 기능에 미치는 영향)

  • Shim, Je-Myung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.3
    • /
    • pp.201-207
    • /
    • 2009
  • Purpose:The purpose of this study was to investigate the effect of $\alpha$-wave music and art appreciation on hand function in stroke with hemiplegia. Methods:A total of 32 stroke with hemiplegia participated in this study experimental group(16 subjects) received $\alpha$-wave music and art appreciation with general neurologic therapy. Control group(16 subjects) received general neurologic therapy. All subjects were assessed for hand function(manual dexterity, power grip, pinch grip, two point discrimination(parm, finger), tactile sense(parm, finger) using a purdue pegboard, dynamometer, pinch gauge, two-point anethesiometer and semmes-weinstein monofilament wire. The data were analyzed using paired and independent t-test. Results:The results were as follows : 1. In the experimental group, manual dexterity were significantly increased between pre and post intervention(p<.05). 2. In the experimental group, tactile sesne in finger were sifnificantly increased between pre and post intervention(p<.05). Conclusion:The results of this study shows that $\alpha$-wave music and art appreciation affect the hand function of hemiplegic side with regard to manual dexterity and tactile sense.

  • PDF

Absolute Distance Measurements Using the Optical Comb of a Femtosecond Pulse Laser

  • Jin, Jong-Han;Kim, Young-Jin;Kim, Yun-Seok;Kim, Seung-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.4
    • /
    • pp.22-26
    • /
    • 2007
  • We describe a new way of implementing absolute displacement measurements by exploiting the optical comb of a femtosecond pulse laser as a wavelength ruler, The optical comb is stabilized by locking both the repetition rate and the carrier offset frequency to an Rb clock of frequency standard. Multiwavelength interferometry is then performed using the quasi-monochromatic beams of well-defined generated wavelengths by tuning an external cavity laser diode consecutively to preselected light modes of the optical comb. This scheme of wavelength synthesizing allows the measurement of absolute distances with a high precision that is traceable to the definition of time. The achievable wavelength uncertainty is $1.9{\times}10^{-10}$, which allows the absolute heights of gauge blocks to be determined with an overall calibration uncertainty of 15 nm (k = 1). These results demonstrate a successful industrial application of an optical frequency synthesis employing a femtosecond laser, a technique that offers many possibilities for performing precision length metrology that is traceable to the well-defined international definition of time.

The Effects of $\alpha$-Wave Music and Art Appreciation on Hand Function (알파파 음악과 미술 감상이 손 기능에 미치는 영향)

  • Shim, Jae-Myoung;Kim, Chung-Sun;Goo, Bong-Oh
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.75-79
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the effect of $\alpha$-wave music and art appreciation on hand function. Methods: A total of 22 university students participated in this study (10 males and 12 females). Twelve subjects received $\alpha$-wave music and art appreciation. The other subjects received neither. All subjects were assessed for hand function (manual dexterity, power grip, pinch, lateral pinch, tactile sense) using a Purdue pegboard, dynamometer, pinch gauge, and Semmes-Weinstein monofilament wire. The data were analyzed using paired and independent t-tests. Results: The results were as follows: 1. In the experimental group, manual dexterity and tactile sense were significantly increased between pre- and post-intervention (p<0.05). Within the control group, manual dexterity and power grip were significantly increased between pre- and post-test (p<0.05). 2. With regard to dexterity and tactile sense, the experimental group experienced a significant post-intervention increase compared to the control group (p<0.05). There was no significant difference in power grip, pinch, or lateral pinch changes between the two groups (p>0.05). Conclusion: The results of this study show that $\alpha$-wave music and art appreciation affect hand function with regard to manual dexterity and tactile sense.

  • PDF

Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study

  • Elsyad, Moustafa Abdou;Setta, Fathi Abo;Khirallah, Ahmed Samir
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.116-124
    • /
    • 2016
  • PURPOSE. The aim of the present study was to evaluate, by means of strain gauge analysis, the effect of different implant angulations on strains around two implants retaining mandibular overdenture with Locator attachments. MATERIALS AND METHODS. Four duplicate mandibular acrylic models were constructed. Two implants were inserted in the canine regions using the following degrees of distal inclinations: group I (control); $0^{\circ}$, group II; $10^{\circ}$, group III; $20^{\circ}$, and group IV; $30^{\circ}$. Locator pink attachments were used to connect the overdenture to the implants and Locator red (designed for severely angled implants) was used for group IV (group $IV_{red}$). For each group, two linear strain gauges were attached at the mesial and distal surfaces of the acrylic resin around each implant. Peri-implant strain was measured on loading and non-loading sides during bilateral and unilateral loading. RESULTS. For all groups, the mesial surfaces of the implants at loading and non-loading sides experienced compressive (negative) strains, while the distal implant surfaces showed tensile (positive) strains. Group IV showed the highest strain, followed by group III, group II. Both group I and group $IV_{red}$ showed the lowest strain. The strain gauges at the mesial surface of the loading side recorded the highest strain, and the distal surface at non-loading side showed the lowest strain. Unilateral loading recorded significantly higher strain than bilateral loading. CONCLUSION. Peri-implant strains around two implants used to retain mandibular overdentures with Locator attachments increase as distal implant inclination increases, except when red nylon inserts were used.

An experimental Study on the Development of a Program for the Promotion of the Compliance with Sick Role Behavior in the Hypertensives (고혈압자의 환자역할행위 이행증진을 위한 프로그램개발에 관한 연구)

  • 최부옥;차영남;장효순;김영희
    • Journal of Korean Academy of Nursing
    • /
    • v.19 no.1
    • /
    • pp.5-23
    • /
    • 1989
  • This experimental study was undertaken to gauge the possibility of application and extension of a program for hypertension care to be operated by Community Health Practitioners. Four community health posts were selected. Two places were experimental groups and the other two control groups. The study was carried out from April 1987 to March 1988. In this study the hypertensives were screened form a group of adults who were over 20 years old. The rate of prevalence was 10.7% in the experimental group, and 11.1% in the control group. The hypertension care program was composed of three parts : regular care by CHPs, reinforcement of education and family support for the changing of health beliefs. The data for this analysis is based on 109 the hypertensives, with 78 from the experimental group and 31 from the control group. After the program was completed, the results obtained were as follows ; 1) Sick role behavior compliance in the experimental group were significantly higher than the control group. 2) Blood pressures were decreased in both systolic and diastolic in the experimental group. Diastolic pressure was strikingly decreased from those of the control group and showed statistical significance (p<0.05). 3) In the experimental group, benefits, perceived family support and family support behavior were high, out benefits was significantly higher than those of the control group(p=0.000). Sensitivity, seriousness and barriers were high in the control group, but not statistically significant. 4) In conclusion, it is revealed that hypertension care program developed in this study has an effect of decreasing blood pressure and promoting sick role behavior compliance.

  • PDF

Effect of Electrode Placement on Procaine Iontophoresis (전극배치가 Procaine 이온도입에 미치는 영향)

  • Lee, Jae-Hyoung;Song, In-Young;Kook, Jee-Youn
    • Journal of Korean Physical Therapy Science
    • /
    • v.4 no.2
    • /
    • pp.399-403
    • /
    • 1997
  • The purpose of this study was to determine the efficacy of electrode placement on procaine iontophoresis. Thirty-three healthy students with an age range of 19 to 34 years, were participated in this study. The subjects were randomly assigned into 3 groups. Each subjects received iontophoresis on the proximal 1/3 of volar surface of dominant forearm with soft cotton pad($3.5{\times}3.5cm$) soaked in 2 ml of 4% procaine hydrochloride (pH 5.1) at 4 mA for 10 minutes(total current 40 mA min) of anodal DC. In transversal electrode placement(TEP) group, dispersive electrode was placed on the proximal 1/3 of dorsal surface of the forearm. In longitudinal electrode placement (LEP) group and control group, dispersive electrode were placed on the distal 1/3 of volar surface of the forearm. After procaine iontophoresis, duration of anesthesia were evaluated at five minutes intervals on five random locations in the iontophoretically area using a 21-gauge sterile hypodermic needle pressed with 1 mm invagination until return the sharp pin-pricking pain sensation. The data were ana lysed with one-way ANOVA to determine signific~nt differences between groups. The results showed significantly differences in the local anesthetic duration between the 3 groups(p<0.001). The anesthetic durations of TEP group and LEP group were significantly longer when compared with control group(p<0.05). Anesthetic durations of TEP group and LEP group were not significantly difference, but anesthetic duration of LEP group tends to longer than TEP group. In view of these results, clinicians should consider the electrode placement method when performing the iontophoresis.

  • PDF

A STUDY OF THE STRESS TRANSMISSION OF VARIOUS ARTIFICIAL TEETH AND DENTURE BASE MATERIALS TO THE UNDER-LYING SUPPORTING TISSUES (인공치와 의치상의 재질에 따른 의치상 하부 지지조직에의 응력전달에 관한 연구)

  • Chung, Hyun-Gun;Chung, Moon-Kyu;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.79-100
    • /
    • 1989
  • The Purpose of this study was to investigate material differences in stress transmission among various artificial teeth and denture base materials. For this study, a two-dimensional finite element model and a two-dimensional photoelastic model of a mandible with complete denture were made. A resin tooth and a porcelain tooth were used as artificial teeth, and a resin base, a metal lined base, and a soft-liner lined base were used as denture bases. An occlusal load was applied and principal stresses generated in the supporting tissues were compared. To test the impact stress transmission, strain gauge attached to the denture base specimens made of the different materials were made in thick and thin groups. Voltage outputs from hitting the specimen with a steel ball were compared. The results were as follows : 1. In FEM, increasing the mucosal thickness reduced the maximum principal stresses in the supporting tissues, but altering the tooth materials and the base materials induced no difference in the stresses. 2. In photoelastic model study, no difference in fringe order among the specimens were observed, but the thick mucosa group and the soft-liner lined group revealed a more uniform distribution of the load. 3. In strain measuring, the impact force transmission was highest in the soft-liner lined group, and was the lowest in the metal lined group(p<0.01). 4. In the thin group using the resin base, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the thick group. In the soft-liner lined group, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the metal lined group. 5. The thick group showed lower impact stress transmission than the thin group(p<0.01).

  • PDF

Peripheral metabotropic glutamate receptors differentially modulate mustard oil-induced craniofacial muscle pain in lightly anesthetized rats

  • Lee, Min-K.;Yang, Gwi-Y.;Ahn, Dong-K.
    • International Journal of Oral Biology
    • /
    • v.33 no.3
    • /
    • pp.97-103
    • /
    • 2008
  • The present study investigated the role of peripheral group I, II, and III metabotropic glutamate receptors (mGluRs) in mustard oil (MO)-induced nociceptive response in the masseter muscles of lightly anesthetized rats. Experiments were carried out on male Sprague-Dawley rats weighing 300-350 gm. After initial anesthesia with sodium pentobarbital (40 mg/kg, i.p.), one femoral vein was cannulated and connected to an infusion pump for intravenous infusion of sodium pentobarbital. The rate of infusion was adjusted to provide a constant level of anesthesia. MO (30 ${\mu}L$) was injected into the mid-region of the left masseter muscle via a 30-gauge needle over 10 seconds. After 30 mL injection of 5, 10, 15, or 20% MO into the masseter muscle, total number of hindpaw-shaking behavior was monitored. Intramuscular administration of MO significantly produced hindpawshaking behavior in a dose-dependent manner, as compared with the vehicle (mineral oil)-treated group. Intramuscular pretreatment with 10 or 100 ng DHPG, a group I mGluRs agonist, enhanced MO-induced hindpaw-shaking behavior, while APDC (20 or 200 ${\mu}g$), a group II mGluRs agonist, or L-AP4 (2 ${\mu}g$), a group III mGluRs agonist, significantly reduced MO-induced nociceptive behavior. The antinociception, produced by group II or III mGluRs agonists, was abolished by pretreatment with LY341495, a group II mGluRs antagonist, or CPPG, a group III mGluRs antagonist, res-pectively. Based on these observations, peripheral mGluRs differentially modulated MO-induced nociceptive behavior response in the craniofacial muscle pain and peripheral group II and III mGluRs agonists could be used in treatment of craniofacial muscle nociception.

Effectiveness of education regarding cuff pressure after endotracheal intubation (기관내 튜브삽관 후 커프 압력에 대한 교육 효과)

  • Uhm, Dong-Choon;Koh, Bong-Yeun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.2
    • /
    • pp.7-15
    • /
    • 2017
  • Purpose: This study investigated the effectiveness of education regarding cuff pressure following endotracheal tube intubation using a quasi-experimental design with a pre- and posttest non-equivalent control group. Methods: A total of 78 students from two universities participated in an education intervention on the importance of cuff pressure after endotracheal tube intubation between October and December, 2016. The intervention lasted 40 minutes. Data were collected from each student before the intervention and one week following the intervention. Analyses were conducted using chi-square tests, Fisher's exact tests, and analysis of covariance. Results: A total of 38 students were assigned to the experimental group and 40 to the control group. The educational intervention of cuff pressure following endotracheal tube intubation was associated with prevention of possible complications from excessive cuff pressure (F=121.02, p<.001). Conclusion: Training with a pressure gauge and an intubation manikin is necessary to determine the appropriate cuff pressure in the intubation protocol of the practical examination in the emergency medical technology.