• 제목/요약/키워드: gated blood pool SPECT

검색결과 6건 처리시간 0.021초

게이트심장혈액풀 스캔과 게이트심장혈액풀 SPECT를 이용한 심실기능의 평가 (Assessment of Ventricular Function Using Gated Blood Pool Scan and Gated Blood Pool SPECT)

  • 박석건
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.100-106
    • /
    • 2005
  • Non-invasive evaluation of cardiac function by nuclear medicine technologies are one of the major contribution of nuclear medicine. Gated cardiac blood pool scan was once a novel and robust technique which enabled evaluation of ventricular function. Concept of EKG gating was one of the major breakthrough in nuclear cardiology. According to the evolution of echocardiographic techniques, and as the evaluation of myocardial perfusion by perfusion SPECT became feasible, number of gated blood pool study dong in nuclear medicine laboratory is declining. And recently, evaluation of ventricular function with gated perfusion SPECT further decreased the use of gated blood pool scan. In this article, assessment of ventricular function using gated blood pool scan is discussed including some insight about the role of gated blood pool SPECT.

게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구 (Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography)

  • 정지욱;이효영;윤종준;이화진;이무석;송현석;박세윤;김재환
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.150-154
    • /
    • 2010
  • 심장기능을 평가하는데 중요한 기준이 되는 심박출계수의 측정은 반복검사가 용이한 심초음파가 가장 흔히 사용되고 있다. 현재 게이트심장혈액풀스캔의 검사 빈도가 낮고 게이트심장혈액풀 SPECT를 이용한 좌심실 심박출계수의 결과는 게이트심장혈액풀스캔과 심초음파의 결과와 비교적 잘 맞는 것으로 알려져 있으나 임상적으로는 잘 이용되지 못하고 있다. 이에 본 연구에서는 게이트심장혈액풀스캔 및 SPECT에서의 심박출계수를 심초음파와 비교하여 분석하였다. 2007년 1월부터 2010년 5월까지 34명의 환자를 대상으로 심초음파 검사 후 게이트심장혈액풀스캔과 SPECT를 함께 시행하였다. 대상 환자 가운데 남자가 23명이었고 여자는 11명이었으며 평균연령은 $52.6{\pm}27.2$세였다. 환자에게 생리식염수로 희석한 pyrophosphate 1 cc를 먼저 정맥주사하고 15분 후 20 mCi의 $^{99m}{TcO_4}^-$를 정맥주사 하였다. 10분 후 안정 상태에서 심전도를 부착한 뒤 planar와 SPECT를 연속하여 촬영하고 ADAC Laboratories, Ver. 4.20 software를 이용하여 영상을 분석하고 각각의 심박출계수를 측정하였다. 일원배치 분산분석(one-way anova) 후 사후검정(Tukey test)을 통해 평균값을 비교하고 서로 간 pearson 상관계수를 구하였다(SPSS Ver 17.0). 심박출계수의 평균값과 표준편차값은 planar에서 $56.3{\pm}13.9$ (%), SPECT에서 $60.4{\pm}16.0$ (%), 심초음파에서는 $59.1{\pm}14.4$ (%)로 유의한 차이는 없었으며(p=0.486) 이에 대한 사후 검정은 planar-심초음파 p=0.697, SPECT-심초음파 p=0.928, planar-SPECT p=0.469로 유의한 차이가 없었다. 상관관계에서는 planar-심초음파 r=0.801, SPECT-심초음파 r=0.810, planar-SPECT r=0.873 비교적 높은 상관관계를 보였다(p<0.01). 게이트혈액풀스캔 및 SPECT와 심초음파를 이용하여 구한 좌심실의 심박출계수는 높은 상관성을 보였으며 평균값에서도 유의한 차이는 없었다. 현재 게이트혈액풀스캔은 시행건수가 줄어들고 스캔의 정확성이나 재현성에 대한 문제는 남아있으며 SPECT의 경우 임상적으로 잘 적용되지 못하고 있으나 다양한 심기능 지표들을 얻을 수 있고 혈액풀스캔에서의 심박출계수와 좋은 일치율을 보이므로 심초음파를 대체할 수 있는 유용한 검사법이라 생각된다.

  • PDF

심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성 (Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography)

  • 배문선;문대혁
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

관상동맥질환에서 휴식기의 심근관류 정도와 휴식기 심기능 변화의 비교 - Dipyridamole 부하 $^{99m}Tc-MIBI$ SPECT와 휴식기 Gated Blood Pool Scan - (Comparison between Myocardial Perfusion and Function in Rest State in Coronary Artery Disease - Dipyridamole $^{99m}Tc-MIBI$ SPECT and Rest Gated Blood Pool Scan -)

  • 최창운;이동수;김상은;배상균;양형인;정준기;이명묵;이명철;박영배;서정돈;이영우;고창순
    • 대한핵의학회지
    • /
    • 제26권2호
    • /
    • pp.265-273
    • /
    • 1992
  • Rest gated blood pool scan (Rest GBP scan) and dipyridamole $^{99m}Tc-MIBI$ SPECT were Performed in 34 patients with or suspected coronary artery disease. Both studies were performed within $2\sim32$ days (mean 8.1 days). A significant correlation was present between left ventricular ejection fraction (r= -0.7356, p<0.001) and peak ejection rate and peak filling rate in rest GBP scan and perfusion defect in MIBI SPECT. And there were acceptable correlations (0.05$26.2{\pm}10.8%$, severe hypokinesia, akinesia or dyskinesia in 16 regions: $78.2{\pm}23.7$, p<0.001). These data indicate there is a significant coupling between the degree of myocardial perfusion and the myocardial functional change in coronary artery disease.

  • PDF

게이트 Tl-201 관류 SPECT와 Cedars 소프트웨어를 이용하여 측정한 좌심실 구혈률 (Left Ventricular Ejection Fraction Determined by Gated Tl-201 Perfusion SPECT and Quantitative Software)

  • 현인영;김성은;서정기;홍의수;권준;박금수;이우형
    • 대한핵의학회지
    • /
    • 제34권3호
    • /
    • pp.222-227
    • /
    • 2000
  • 목적: 게이트 Tl-201 관류 SPECT와 Cedars 소프트웨어로 구혈률을 측정하고 게이트 심장 혈액풀 스캔으로 얻은 구혈률과 비교하여 상관과 일치도를 분석하였다. 대상 및 방법: 총 18명을 대상으로 게이트 Tl-201 관류 SPECT와 게이트 심장 혈액풀 스캔을 촬영하였다. 게이트 관류 SPECT를 재구성하고 Cedars 소프트웨어로 구혈률을 측정하였다. 게이트 Tl-201 관류 SPECT와 게이트 심장 혈액풀 스캔으로 얻은 구혈률의 상관을 분석하고 Bland Altman 도표를 그려 일시도를 평가하였다. 결과: 게이트 심장 혈액풀 스캔($43%{\pm}14%$)보다 게이트 Tl-201 관류 SPECT로 측정한 구혈률($40%{\pm}14%$)이 유의하게 작았고(p<0.05), 상관은 좋았다(r=0.94). Bland Altman 도해에서 두 방법의 일치도에 대한 95% 신뢰도를 나타내는 2표준편차에 상당하는 범위는 ${\pm}9.8%$로 작지 않았다. 결론: 게이트 Tl-201 관류 SPECT와 심장 혈액풀 스캔으로 측정한 구혈률의 상관은 좋았으나 일치도에 대한 넓은 오차 범위 때문에 구혈률 측정에 두 검사 방법을 교체하여 사용할 수는 없었다.

  • PDF

Tc-99m-MIBI 심근 SPECT 극성지도 분석에 의한 심근 기능의 정량적 평가 (A Quantitative Method for the Assessment of Myocardial Function using the Polar Analysis of Tc-99m-MIBI Myocardial SPECT)

  • 곽철은;이동수;여정석;이경한;정준기;이명철;서정돈;고창순
    • 대한핵의학회지
    • /
    • 제28권2호
    • /
    • pp.172-176
    • /
    • 1994
  • 심근 SPECT에 의한 심근질환의 심도 및 허혈부위를 평가하는 방법으로 정상인의 극성지도와의 비교에 의한 결손지도 평가방법이 상용화되었으나 본 연구에서는 결손부위의 범위만을 산출할 수 있었던 종래의 방법을 개선할 수 있는 관류회복정도 및 심도성적 산출 방법을 시도하여 보았다. 허혈 및 심도성적의 산출에서 부하 및 휴식기 극성지도의 차이를 3등급으로 분할하여 각 등급에 해당되는 화소의 수를 가중하므로서 관류결손부위의 면적이 반영된 허혈 및 심도성적 산출방법을 제안하고자 하였으며, 등급 및 가중치의 할당은 정상인의 잔상동맥영역별 관류분포를 반영하여 고른 등급 할당방법보다 상관도가 개선된 결과를 얻을 수 있었다.