• Title/Summary/Keyword: gastrointestinal time

Search Result 508, Processing Time 0.031 seconds

In-hospital malnutrition among adult patients in a national referral hospital in Indonesia

  • Dyah Purnamasari;Nur Chandra Bunawan;Dwi Suseno;Ikhwan Rinaldi;Drupadi HS Dillon
    • Nutrition Research and Practice
    • /
    • v.17 no.2
    • /
    • pp.218-227
    • /
    • 2023
  • BACKGROUND/OBJECTIVES: Malnutrition during hospitalization is linked to increased morbidity and mortality, but there are insufficient studies observing clinical factors contributing to weight loss during hospitalization in Indonesia. This study was therefore undertaken to determine the rate of weight loss during hospitalization and the contributing factors. SUBJECTS/METHODS: This was a prospective study involving hospitalized adult patients aged 18-59 yrs, conducted between July and September 2019. Body weight measurement was taken at the time of admission and on the last day of hospitalization. The factors studied were malnutrition at admission (body mass index < 18.5 kg/m2), immobilization, depression (Beck Depression Inventory-II Indonesia), polypharmacy, inflammatory status (neutrophil-lymphocytes ratio; NLR), comorbidity status (Charlson Comorbidity Index; CCI), and length of stay. RESULTS: Totally, 55 patients were included in the final analysis, with a median age of 39 (18-59 yrs) yrs. Of these, 27% had malnutrition at admission, 31% had a CCI score > 2, and 26% had an NLR value of ≥ 9. In all, 62% presented with gastrointestinal symptoms, and depression was documented in one-third of the subjects at admission. Overall, we recorded a mean weight loss of 0.41 kg (P = 0.038) during hospitalization, with significant weight loss observed among patients hospitalized for 7 days or more (P = 0.009). The bivariate analysis revealed that inflammatory status (P = 0.016) was associated with in-hospital weight loss, while the multivariate analysis determined that the contributing factors were length of stay (P < 0.001) and depression (P = 0.019). CONCLUSIONS: We found that inflammatory status of the patient might influence the incidence of weight loss during hospitalization, while depression and length of stay were independent predictors of weight loss during hospitalization.

Using US Patent Analysis to Monitor the Technological Trend in the Field of Gastrointestinal Microbiome - Implications on Korean Medicine Research and Development - (미국 특허분석으로 보는 장내 미생물 기술 발전 현황 - 한의학 연구 및 한의약 기술 발전에 주는 시사점 -)

  • Geoncheol Jo;Sejun Yoon;Jeong Woon ,Bae;Byung Joo Kim
    • The Journal of Korean Medicine
    • /
    • v.44 no.1
    • /
    • pp.38-55
    • /
    • 2023
  • Objectives: The purpose of this study was to provide direction for future research in the field of Korean medicine by analyzing microbiome based technologies emerging as a new diagnostic and treatment paradigm. Methods: To achieve the purpose of the study intellectual property data was used. After establishing citation network from registered microbiome-related US patents, citation network was analyzed by knowledge persistence-based main path approach to understanding technological trajectories. Furthermore, community detection algorithms were used to quantitatively identifying specific technological domain in a particular time period. Results: Results shows that early technologies in livestock industry contribute most to the recent patents. Knowledge in the patents flow through the path of food and beverage technological domain, and finally are inherited to the recent development of diagnosis, treatment and prevention technic. Conclusions: This study indicate that developing diagnostic tools which can link the composition of microbiome to specific diseases should be given high priority. Researches should lead to novel therapeutic strategies. Specifically, improving reliability of pattern identification and finding effective therapeutic compositions based on principles of Korean medicine is necessary.

Dosimetric Evaluation of Synthetic Computed Tomography Technique on Position Variation of Air Cavity in Magnetic Resonance-Guided Radiotherapy

  • Hyeongmin Jin;Hyun Joon An;Eui Kyu Chie;Jong Min Park;Jung-in Kim
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.142-149
    • /
    • 2022
  • Purpose: This study seeks to compare the dosimetric parameters of the bulk electron density (ED) approach and synthetic computed tomography (CT) image in terms of position variation of the air cavity in magnetic resonance-guided radiotherapy (MRgRT) for patients with pancreatic cancer. Methods: This study included nine patients that previously received MRgRT and their simulation CT and magnetic resonance (MR) images were collected. Air cavities were manually delineated on simulation CT and MR images in the treatment planning system for each patient. The synthetic CT images were generated using the deep learning model trained in a prior study. Two more plans with identical beam parameters were recalculated with ED maps that were either manually overridden by the cavities or derived from the synthetic CT. Dose calculation accuracy was explored in terms of dose-volume histogram parameters and gamma analysis. Results: The D95% averages were 48.80 Gy, 48.50 Gy, and 48.23 Gy for the original, manually assigned, and synthetic CT-based dose distributions, respectively. The greatest deviation was observed for one patient, whose D95% to synthetic CT was 1.84 Gy higher than the original plan. Conclusions: The variation of the air cavity position in the gastrointestinal area affects the treatment dose calculation. Synthetic CT-based ED modification would be a significant option for shortening the time-consuming process and improving MRgRT treatment accuracy.

Diagnosis of Metastatic Undifferentiated Sarcoma by Endoscopic Ultrasound Guided Fine Needle Aspiration (EUS-FNA) (내시경초음파 세침흡인술을 통한 전이성 미분화육종의 진단)

  • Si Young Kim;Hee Seung Lee;Moon Jae Chung;Jeong Youp Park;Seungmin Bang;Seung Woo Park;Si Young Song
    • Journal of Digestive Cancer Research
    • /
    • v.5 no.2
    • /
    • pp.120-124
    • /
    • 2017
  • A-49-year-old male patient with no specific medical history was admitted to the clinic because of persistent epigastric pain radiating to back for 4 months. He had multiple parenchymal tumors in body and tail of pancreas, para-spinal muscle, and mediastinum on abdomen CT image. Cytologic examination of the pancreas which was done by endoscopic ultrasound guided fine needle aspiration (EUS-FNA) showed adenocarcinoma, whereas histological examination of the para-spinal mass showed undifferentiated sarcoma. Histologic examination of the pancreatic mass was made through endoscopic ultrasound guided fine needle biopsy (EUS-FNB) for accurate diagnosis, and the histologic examination of both the pancreas and posterior mediastinal mass showed the same undifferentiated sarcoma. Therefore, we reviewed the cytopathic tissue obtained from the pancreas for the first time, and it was confirmed to be similar to histologic findings in the mediastinal mass.

  • PDF

Response to Capecitabine Treatment Following Palliative Chemotherapy for Metastatic Colorectal Cancer: A Case Report (고식적 항암화학요법 후에 Capecitabine 단독치료에 반응을 보인 전이성 대장암 환자 1례)

  • Dae Hwa Park;Ju Seok Kim;Sun Hyung Kang;Hee Seok Moon;Jae Kyu Sung;Hyun Yong Jeong
    • Journal of Digestive Cancer Research
    • /
    • v.5 no.1
    • /
    • pp.66-69
    • /
    • 2017
  • Approximately 40% of patients with colorectal cancer have metastatic lesions at the time of diagnosis, and chemotherapy is generally prescribed for these patients. Though several drugs are used, 5-FU has long been the backbone of chemotherapy for colorectal cancer. Capecitabine is an oral 5-FU prodrug approved by the FDA in 2005 and is used alone or in combination for treatment of colorectal cancer. Recently, capecitabine has been used for a number of off-label indications, including the treatment of advanced or metastatic colorectal cancer. Here, we report a rare case of a 59-year-old woman, diagnosed with metastatic colorectal cancer who first presented with abdominal discomfort and dyspepsia. She showed a partial response to palliative first line FOLFOX chemotherapy, which had to be stopped due to peripheral neuropathy, as a side effect. She was next put on a second line chemotherapy regimen with capecitabine alone, since then she showed good treatment response without any disease progression.

  • PDF

Novel Clean End-to-End Anastomosis Method, Without Opening the Stomach Lumen, in Totally Laparoscopic or Robotic Pylorus-Preserving Gastrectomy

  • Takashi Mitsui;Kazuyuki Saito;Yuhei Hakozaki;Yoshiyuki Miwa;Takuji Noro;Emiko Takeshita;Taizen Urahashi;Yasuyuki Seto;Takashi Okuyama;Hideyuki Yoshitomi
    • Journal of Gastric Cancer
    • /
    • v.23 no.4
    • /
    • pp.523-534
    • /
    • 2023
  • Purpose: Intra-abdominal infection is a common postoperative complication of laparoscopic pylorus-preserving gastrectomies (PPGs). Many studies have reported that intra-abdominal infectious complications after gastrectomy adversely affect patient survival outcomes. To prevent gastric fluid leakage into the abdominal cavity, we developed a novel anastomosis method in which the stomach lumen is not opened (termed the non-opened clean end-to-end anastomosis method [NoCEAM]) and evaluated its feasibility. Materials and Methods: Subsequent to lymphadenectomy, the oral and anal resection lines were sutured using an intraoperative endoscope. After closing the stomach circumferentially with clips, the specimen was rolled outward like a "donut." We resected the specimen circumferentially using a linear stapler, and anastomosis was completed simultaneously. We examined the feasibility of this procedure ex vivo, using three porcine stomachs, and in vivo, using one pig. Subsequently, we applied the procedure to 13 consecutive patients with middle-third early gastric cancer utilizing laparotomic, laparoscopic, and robotic PPG. Results: NoCEAM was completed in all porcine models and human cases. In the human cases, the mean operation time (±standard deviation) was 279±51 minutes, and mean blood loss volume was 22±45 mL. The mean number of linear staples used was 5.06±0.76. None of the patients had complications, and all were discharged on the eighth postoperative. The serum total protein, serum albumin, and hemoglobin levels did not change significantly after surgery. Conclusions: NoCEAM is feasible and safe for performing totally laparoscopic or robotic PPG. It may reduce postoperative complications, such as intra-abdominal infections.

Unconventional shunt surgery for non-cirrhotic portal hypertension in patients not suitable for proximal splenorenal shunt

  • Harilal, S L;Biju Pottakkat;Senthil Gnanasekaran;Kalayarasan Raja
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.3
    • /
    • pp.264-270
    • /
    • 2023
  • Backgrounds/Aims: Proximal splenorenal shunt (PSRS) is a commonly performed procedure to decompress portal hypertension, in patients with refractory variceal bleed, especially in non-cirrhotic portal hypertension (NCPH). If conventional methods are hindered by any technical or pathological factors, alternative surgical techniques may be required. This study analyzes the effectiveness of various unconventional shunt surgeries performed for NCPH. Methods: A retrospective analysis of NCPH patients who underwent unconventional shunt surgeries during the period July 2011 to June 2022 was conducted. All patients were followed up for a minimum of 12 months with doppler study of the shunt to assess shunt patency, and upper gastrointestinal endoscopy to evaluate the regression of varices. Results: During the study period, 130 patients underwent shunt surgery; among these, 31 underwent unconventional shunts (splenoadrenal shunt [SAS], 12; interposition mesocaval shunt [iMCS], 8; interposition PSRS [iPSRS], 6; jejunal vein-cava shunt [JCS], 3; left gastroepiploic-renal shunt [LGERS], 2). The main indications for unconventional shunts were left renal vein aberration (SAS, 8/12), splenic vein narrowing (iMCS, 5/8), portalhypertensive vascular changes (iPSRS, 6/6), and portomesenteric thrombosis (JCS, 3/3). The median fall in portal pressure was more in SAS (12.1 mm Hg), and operative time more in JCS, 8.4 hours (range, 5-9 hours). During a median follow-up of 36 months (6-54 months), shunt thrombosis had been reported in all cases of LGERS, and less in SAS (3/12). Variceal regression rate was high in SAS, and least in LGERS. Hypersplenism had reversed in all patients, and 6/31 patients had a recurrent bleed. Conclusions: Unconventional shunt surgery is effective in patients unsuited for other shunts, especially PSRS, and it achieves the desired effects in a significant proportion of patients.

Utility of narrow-band imaging with or without dual focus magnification in neoplastic prediction of small colorectal polyps: a Vietnamese experience

  • Tien Manh Huynh;Quang Dinh Le;Nhan Quang Le;Huy Minh Le;Duc Trong Quach
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.479-489
    • /
    • 2023
  • Background/Aims: Accurate neoplastic prediction can significantly decrease costs associated with pathology and unnecessary colorectal polypectomies. Narrow-band imaging (NBI) and dual-focus (DF) mode are promising emerging optical technologies for recognizing neoplastic features of colorectal polyps digitally. This study aimed to clarify the clinical usefulness of NBI with and without DF assistance in the neoplastic prediction of small colorectal polyps (<10 mm). Methods: This cross-sectional study included 530 small colorectal polyps from 343 consecutive patients who underwent colonoscopy at the University Medical Center from September 2020 to May 2021. Each polyp was endoscopically diagnosed in three successive steps using white-light endoscopy (WLE), NBI, and NBI-DF and retrieved for histopathological assessment. The diagnostic accuracy of each modality was evaluated with reference to histopathology. Results: There were 295 neoplastic polyps and 235 non-neoplastic polyps. The overall accuracies of WLE, WLE+NBI, and WLE+NBI+NBI-DF in the neoplastic prediction of colorectal polyps were 70.8%, 87.4%, and 90.8%, respectively (p<0.001). The accuracy of WLE+NBI+NBI-DF was significantly higher than that of WLE+NBI in the polyp size ≤5 mm subgroup (87.3% vs. 90.1%, p<0.001). Conclusions: NBI improved the real-time neoplastic prediction of small colorectal polyps. The DF mode was especially useful in polyps ≤5 mm in size.

Covered self-expandable metallic stents versus plastic stents for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction

  • Taro Shibuki;Kei Okumura;Masanari Sekine;Ikuhiro Kobori;Aki Miyagaki;Yoshihiro Sasaki;Yuichi Takano;Yusuke Hashimoto
    • Clinical Endoscopy
    • /
    • v.56 no.6
    • /
    • pp.802-811
    • /
    • 2023
  • Background/Aims: Covered self-expandable metallic stents (cSEMS) have become popular for endoscopic ultrasound-guided hepaticogastrostomy with transmural stenting (EUS-HGS). We compared the time to recurrent biliary obstruction (TRBO), complications, and reintervention rates between EUS-HGS using plastic stent (PS) and cSEMS in patients with unresectable malignancies at multicenter institutions in Japan. Methods: Patients with unresectable malignant biliary obstruction who underwent EUS-HGS between April 2015 and July 2020 at any of the six participating facilities were enrolled. Primary endpoint: TRBO; secondary endpoints: rate of complications other than recurrent biliary obstruction and technical success rate of reintervention were evaluated. Results: PS and cSEMS were used for EUS-HGS in 109 and 43 patients, respectively. The TRBO was significantly longer in the cSEMS group than in the PS group (646 vs. 202 days). Multivariate analysis identified two independent factors associated with a favorable TRBO: combined EUS-guided antegrade stenting with EUS-HGS and the use of cSEMS. No significant difference was observed in the rate of complications other than recurrent biliary obstruction between the two groups. The technical success rate of reintervention was 85.7% for PS and 100% for cSEMS (p=0.309). Conclusions: cSEMS might be a better option for EUS-HGS in patients with unresectable malignancies, given the longer TRBO.

Usefulness of a new polyvinyl alcohol hydrogel (PVA-H)-based simulator for endoscopic submucosal dissection training: a pilot study

  • Dong Seok Lee;Gin Hyug Lee;Sang Gyun Kim;Kook Lae Lee;Ji Won Kim;Ji Bong Jeong;Yong Jin Jung;Hyoun Woo Kang
    • Clinical Endoscopy
    • /
    • v.56 no.5
    • /
    • pp.604-612
    • /
    • 2023
  • Background/Aims: We developed a new endoscopic submucosal dissection (ESD) simulator and evaluated its efficacy and realism for use training endoscopists. Methods: An ESD simulator was constructed using polyvinyl alcohol hydrogel sheets and compared to a previous ESD simulator. Between March 1, 2020, and December 30, 2021, eight expert endoscopists from three different centers analyzed the procedure-related factors of the simulator. Five trainees performed gastric ESD exercises under the guidance of these experts. Results: Although the two ESD simulators provided overall favorable outcomes in terms of ESD-related factors, the new simulator had several benefits, including better marking of the target lesion's limits (p<0.001) and overall handling (p<0.001). Trainees tested the usefulness of the new ESD simulator. The complete resection rate improved after 3 ESD training sessions (9 procedures), and the perforation rate decreased after 4 sessions (12 procedures). Conclusions: We have developed a new ESD simulator that can help beginners achieve a high level of technical experience before performing real-time ESD procedures in patients.