• Title/Summary/Keyword: gastrointestinal endoscopy

Search Result 235, Processing Time 0.021 seconds

Estimating Gastrointestinal Transition Location Using CNN-based Gastrointestinal Landmark Classifier (CNN 기반 위장관 랜드마크 분류기를 이용한 위장관 교차점 추정)

  • Jang, Hyeon Woong;Lim, Chang Nam;Park, Ye-Suel;Lee, Gwang Jae;Lee, Jung-Won
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.9 no.3
    • /
    • pp.101-108
    • /
    • 2020
  • Since the performance of deep learning techniques has recently been proven in the field of image processing, there are many attempts to perform classification, analysis, and detection of images using such techniques in various fields. Among them, the expectation of medical image analysis software, which can serve as a medical diagnostic assistant, is increasing. In this study, we are attention to the capsule endoscope image, which has a large data set and takes a long time to judge. The purpose of this paper is to distinguish the gastrointestinal landmarks and to estimate the gastrointestinal transition location that are common to all patients in the judging of capsule endoscopy and take a lot of time. To do this, we designed CNN-based Classifier that can identify gastrointestinal landmarks, and used it to estimate the gastrointestinal transition location by filtering the results. Then, we estimate gastrointestinal transition location about seven of eight patients entered the suspected gastrointestinal transition area. In the case of change from the stomach to the small intestine(pylorus), and change from the small intestine to the large intestine(ileocecal valve), we can check all eight patients were found to be in the suspected gastrointestinal transition area. we can found suspected gastrointestinal transition area in the range of 100 frames, and if the reader plays images at 10 frames per second, the gastrointestinal transition could be found in 10 seconds.

Changes in Pediatric Gastrointestinal Endoscopy: Review of a Recent Hospital Experience (일개 대학병원에서의 소아 위장관 내시경 시술의 최근 경험)

  • Park, Kyung-Heui;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.1
    • /
    • pp.20-27
    • /
    • 2007
  • Purpose: This study was performed to review the recent experiences of pediatric gastrointestinal (GI) endoscopy done in one university hospital. Methods: A retrospective review of medical records was conducted of 1,040 pediatric cases who underwent GI endoscopy at the Pusan National University Hospital between January 2001 to June 2005. Results: A total of 1,040 endoscopies (upper 840 and lower 200) were performed. The male/female ratio was 1.25:1. Neonates and infants accounted for 6.0% and 16.5% respectively. Half of the children were below 5 years (mean age $8.5{\pm}2.1$ years). Upper and lower GI diagnostic endoscopies were performed in 634 and 163 children respectively. Abdominal pain (38.8%), vomiting (19.4%), foreign body (17.7%), and hematemesis (10.3%) were the main reasons for esophagogastroduodenoscopy. Hematochezia (56.0%), abdominal pain (27.5%) and diarrhea (3.0%) were the main reasons for colonoscopy. Upper GI therapeutic procedures included retrieval of foreign bodies, balloon dilatations of esophageal stricture, PEG, and variceal ligation in 148, 27, 15, and 3 children, respectively. Therapeutic lower GI endoscopies were performed in 37 children (polypectomy in 92%, argon lazer cauterization for angiodysplasia in 4%). Conclusion: GI endoscopy played an important role in the diagnosis and treatment of GI diseases in children. Procedures in younger aged children, cases evaluated by colonoscopy and therapeutic endoscopies are increasing in pediatric practice.

  • PDF

Comparing Endoscopy and Upper Gastrointestinal X-ray for Gastric Cancer Screening in South Korea: A Cost-utility Analysis

  • Chang, Hoo-Sun;Park, Eun-Cheol;Chung, Woo-Jin;Nam, Chung-Mo;Choi, Kui-Son;Cho, Eun;Cho, Woo-Hyun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2721-2728
    • /
    • 2012
  • Background: There are limited data evaluating the cost-effectiveness of gastric cancer screening using endoscopy or upper gastrointestinal x-ray in the general population. Objective: To evaluate the cost-effectiveness of population-based screening for gastric cancer in South Korea by decision analysis. Methods: A time-dependent Markov model for gastric cancer was constructed for healthy adults 30 years of age and older, and a deterministic sensitivity analysis was performed. Cost-utility analysis with multiple strategies was conducted to compare the costs and effects of 13 different screening alternatives with respect to the following eligibility criteria: age at the beginning of screening, screening interval, and screening method. The main outcome measurement was the incremental cost-effectiveness ratio. Results: The results revealed that annual endoscopic screening from ages 50-80 was the most cost-effective for the male population. In the females, biennial endoscopy screening from ages 50-80 was calculated as the most cost-effective strategy among the 12 screening alternatives. The most cost-effective screening strategy may be adjustable according to the screening costs and the distribution of cancer stage at screening. The limitation was that effectiveness data were obtained from published sources. Conclusions: Using the threshold of $19,162 per quality-adjusted life year on the basis of the Korean gross domestic product (2008), as suggested by the World Health Organization, endoscopic gastric cancer screening starting at the age of 50 years was highly cost-effective in the Korean population. The national recommendation for gastric cancer screening should consider the starting age of screening, the screening interval, and the screening modality.

Clinical Role of Magnifying Endoscopy with Narrow-band Imaging in the Diagnosis of Early Gastric Cancer (조기 위암의 진단에 있어서 확대 내시경을 동반한 협대역 내시경의 역할)

  • Soo In Choi
    • Journal of Digestive Cancer Research
    • /
    • v.10 no.2
    • /
    • pp.56-64
    • /
    • 2022
  • Narrow-band imaging (NBI) is the most widely used image-enhanced endoscopic technique. The superficial microanatomy of gastric mucosa can be visualized when used with a magnifying endoscopy with narrow-band imaging (ME-NBI). The diagnostic criteria for early gastric cancer (EGC), using the classification system for microvascular and microsurface pattern of ME-NBI, have been developed, and their usefulness has been proven in the differential diagnosis of small depressed cancer from focal gastritis and in lateral extent delineation of EGC. Some studies reported on the prediction of histologic differentiation and invasion depth of gastric cancer using ME-NBI; however, its application is limited in clinical practice, and further well-designed studies are necessary. Clinicians should understand the ME-NBI classification system and acquire appropriate diagnostic skills through various experiences and training to improve the quality of endoscopy for EGC diagnosis.

Heterotopic bone formation in normal gastric cardiac mucosa (정상 위 분문부 점막에서 발견된 이소성 골 형성)

  • Eom, Seok Hyeon;Park, Chang Hwan;Chung, Duk Won;Lee, Sang Hyeok;Seo, Ji Young;Kim, Yeong Sung;Kwak, Dong Hyup;Kim, Jung Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.146-149
    • /
    • 2016
  • Heterotopic bone formation in the gastrointestinal tract is a rare phenomenon. Most reported cases were associated with benign and malignant neoplasms, except for a case in which heterotopic bone formation was found in a patient with Barrett's esophagus. The exact pathogenesis of the disease has not yet been established. However, most heterotopic bones found in the gastrointestinal tract were associated with mucinproducing tumors of the appendix, colon, and rectum. Inflammation may also play a role in osseous metaplasia in a case with bone formation at the base of an ulcer in Barrett's esophagus. Here, we report on a patient with heterotopic bone formation in normal gastric cardiac mucosa. A 50-year-old female visited our hospital for a routine health examination. She had no gastrointestinal symptoms, and her physical examination, blood test, X-ray, urine, and stool examination results were normal. A 0.3 cm sized polypoid lesion located just below the squamocolumnar junction was observed on upper gastrointestinal endoscopy. A piece of biopsy was taken. Histologically, a lamella bone trabecula and chronic inflammatory cells were observed in the gastric cardiac mucosa. The follow-up endoscopy performed one month later showed no residual lesion.

Clinical Analysis of Foreign Bodies in Gastrointestinal Tract in Children (소아에서 위장관내 이물질의 임상적 고찰)

  • Choi, Eunsoo;Lee, Hyo Gyun;Choi, Soo Jin Na;Chung, Sang Young
    • Advances in pediatric surgery
    • /
    • v.20 no.1
    • /
    • pp.12-16
    • /
    • 2014
  • Foreign body ingestion is a common problem among paediatric populations. Most of the ingested foreign bodies spontaneously pass through the gastrointestinal tract, but approximately less then 10% of them remain without being discharged, and trigger complications. Therefore, proper evaluation and treatment according to the situation is required. In this study, clinical progress and complications were analyzed according to the clinical features and treatment in children who ingested foreign bodies. Among pediatric patients under 18 who were admitted to Chonnam National University Hospital after ingesting foreign bodies between January 2008 to June 2012, only the patients who had their foreign body in the gastrointestinal tract were included in this study. Based on medical records, age, type of foreign body, time spent till admission, and whether the endoscopy was done or not, complication were researched retrospectively. According to symptoms and plain abdomen X-ray findings, treatment was chosen and conducted among endoscopy, observation and emergency operation. Among 273 patients, 9 (3.3%) of them had surgical removal. Seven (2.6%) of them had an emergency operation on the day of admission, and the rest 2 (0.7%) had operation during observation. Removal through initial endoscopic approach was tried in 157 (57.5%) patients. Eleven (70.8%) of them had their foreign body removed at the initial trial, and 5 (4.9%) of them at the second trial. Among 109, who were on observation status, 9 (8.3%) of them needed endoscopic removal, and 2 (1.8%) of them suffered from surgical removal. It is thought to be better to approach slowly considering the type, size and symptoms in foreign body ingestion of pediatric patients, rather than immediate and invasive removal.

Robotics for Advanced Therapeutic Colonoscopy

  • Wong, Jennie YY;Ho, Khek Yu
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.552-557
    • /
    • 2018
  • Although colonoscopy was originally a diagnostic imaging procedure, it has now expanded to include an increasing range of therapeutic interventions. These procedures require precise maneuvers of instruments, execution of force, efficient transmission of force from the operator to the point of application, and sufficient dexterity in the mobilization of endoscopic surgical instruments. The conventional endoscope is not designed to support technically demanding endoscopic procedures. In case of colonoscopy, the tortuous anatomy of the colon makes inserting, moving, and orientating the endoscope difficult. Exerting excessive pressure can cause looping of the endoscope, pain to the patient, and even perforation of the colon. To mitigate the technical constraints, numerous technically enhanced systems have been developed to enable better control of instruments and precise delivery of force in the execution of surgical tasks such as apposing, grasping, traction, counter-traction, and cutting of tissues. Among the recent developments are highly dexterous robotic master and slave systems, computer-assisted or robotically enhanced conventional endoscopes, and autonomously driven locomotion devices that can effortlessly traverse the colon. Developments in endoscopic instrumentations have overcome technical barriers and opened new horizons for further advancements in therapeutic interventions. This review describes examples of some of these systems in the context of their applications to advanced therapeutic colonoscopy.

Have we Comprehensively Evaluated the Effectiveness of Endoscopic Screening for Gastric Cancer?

  • Hamashima, Chisato
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3591-3592
    • /
    • 2015
  • Endoscopy has been increasingly used in clinical practice and as a standardized examination procedure for gastrointestinal diseases. However, only a few studies on endoscopic screening for evaluating mortality reduction from gastric cancer have been carried out. Even if a high detection rate is obtained in clinical practice, such a rate cannot be directly accepted as evidence providing the effectiveness of cancer screening. Endoscopic screening for gastric cancer is not an exception of possibility to detect overdiagnosis. If detection rate is used for the evaluation of the effectiveness of cancer screening, the possibility of overestimating the effectiveness of cancer screening cannot be ruled out. To avoid the effect of overdiagnosis and confirm the effectiveness of endoscopic screening, mortality reduction from gastric cancer must be carefully evaluated by conducting reliable studies. The burden of gastric cancer remains real and this cannot be ignored in Eastern Asian countries. To determine the best available method for gastric cancer screening, evaluation of its effectiveness is a must. Endoscopic screening for gastric cancer has shown promising results, and thus deserves further comprehensive evaluation to reliably confirm its effectiveness and how its optimal use can be strategically promoted.

Treatment Using the SpyGlass Digital System in a Patient with Hepatolithiasis after a Whipple Procedure

  • Harima, Hirofumi;Hamabe, Kouichi;Hisano, Fusako;Matsuzaki, Yuko;Itoh, Tadahiko;Sanuki, Kazutoshi;Sakaida, Isao
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.596-599
    • /
    • 2018
  • An 89-year-old man was referred to our hospital for treatment of hepatolithiasis causing recurrent cholangitis. He had undergone a prior Whipple procedure. Computed tomography demonstrated left-sided hepatolithiasis. First, we conducted peroral direct cholangioscopy (PDCS) using an ultraslim endoscope. Although PDCS was successfully conducted, it was unsuccessful in removing all the stones. The stones located in the B2 segment were difficult to remove because the endoscope could not be inserted deeply into this segment due to the small size of the intrahepatic bile duct. Next, we substituted the endoscope with an upper gastrointestinal endoscope. After positioning the endoscope, the SpyGlass digital system (SPY-DS) was successfully inserted deep into the B2 segment. Upon visualizing the residual stones, we conducted SPY-DS-guided electrohydraulic lithotripsy. The stones were disintegrated and completely removed. In cases of PDCS failure, a treatment strategy using the SPY-DS can be considered for patients with hepatolithiasis after a Whipple procedure.

Analysis and Evaluation of Slanted-edge-based Modulation Transfer Function and Focus Measurements for Optimal Assembly of Imaging Modules in Gastrointestinal Endoscopy

  • Wonju Lee;Ki Young Shin;Dong-Goo Kang;Minhye Chang;Young Min Bae
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.398-407
    • /
    • 2023
  • We explored a method to evaluate imaging performance for the optimal assembly of an endoscopic miniature lens and a sensor constituting an imaging module at the distal end of gastrointestinal endoscopy. For the assembly of the imaging module, the image sensor was precisely located at the focal plane when collimated light passed through the endoscopic lens. As another method, the distance between the lens and sensor was adjusted to obtain the highest focus index from images measured the star chart of the International Organization for Standardization (ISO) standard at various positions. We analyzed the slanted-edge modulation transfer function (MTF), corresponding depth of field, and number of line pairs for MTF 50% and 20% at each working distance within the range of 5-100 mm for imaging modules assembled in different ways. Assembly conditions of the imaging module with better MTF performance were defined for each working distance range of 5-30 mm and 30-100 mm, respectively. In addition to the MTF performance, the focus index of each assembled module was also compared. In summary, we examined the performance of imaging modules assembled with different methods within the suggested working distance and tried to establish the optimal assembly protocol.