• 제목/요약/키워드: gasfication

검색결과 9건 처리시간 0.023초

대표적인 열분해가스화 용융시설의 공정별 다이옥신 배출거동에 관한 연구 (A study on the Dioxin behavior in the process of representative pyrolysis/gasfication/melting plant)

  • 신찬기;신대윤
    • 환경위생공학
    • /
    • 제22권1호
    • /
    • pp.1-16
    • /
    • 2007
  • The incineration process has commonly used for wastes amount reduction and thermal treatments of pollutants as the technologies accumulated. However, the process is getting negative public images owing to matter of hazardous pollutants emission. Specially dioxins became a main issue and is mostly emitted from municipal solid wastes incineration. In this reason, pyrolysis/gasfication/melting process is presented as a alternative of incineration process. The pyrolysis/gasfication/melting process, a novel technology, is middle of verification of commercial plant and development of technologies in Korea. But the survey about the pollutant emission from the process, and background data in these facilities is necessary. So in this survey, it Is investigated that the behavior of dioxins in three pyrolysis/gasfication/melting plant (S, T, P) of pilot scale. In case of S plant, concentration of dioxins shows high at latter part of cogenerated boiler and stack which are operate on low temperature conditions than a latter parts of pyrolysis and melting furnace which are operate on high temperature condition. Concentration of gas phage dioxins had increased after combusted gas passed cogenerated boiler and this is attributed to react of precursor materials such as chlorobenzene and chlorophenol. Concentration of dioxins in T plant showed lower levels at latter part of cooling equipment which are operate with water spray type on low temperature conditions than a latter parts of gasfied melting furnace which are operate on high temperature condition. Removal efficiency of dioxins at gas treatment equipment was 78.8 %. Concentration of dioxins in P plant was low at latter part of SDA/BF which is operate at low temperature conditions than a latter parts of pyrolysis gasfied chamber which are operate at high temperature condition. Removal efficiency of dioxins of SDA/BF was 85.9 % and therefore, it showed high efficiency at those of stoker type incineration facility. However, concentration of dioxins which emitted at high temperature condition were low in three facilities and satisfied present standard emission level of dioxins. To consider the distribution ratio of dioxins, Particulate phase dioxins at S and P plants showed similar ratio with which shows in current stoker type for middle scale domestic waste incineration facility. It is necessary to continuos monitoring the ratio of distribution of dioxins in T plant in because ratio of gas phage dioxins showed high.

A Room-Corner Fire Model을 적용한 건축내장재의 화재확산 특성 평가(1)

  • 김운형
    • 방재기술
    • /
    • 통권24호
    • /
    • pp.32-39
    • /
    • 1998
  • A room-corner fire scenario of ISO 9705 with flame spread model developed by Quintiere is applied to the interior finish materials to show the sensitivity of properties derived from AST, E-1321 and ASTM E-1354 is investigated and various range of thermal properties by the author were analyzed in the model. There are including flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The time for total energy release rate to reach 1MW is examined. Though some areas are neede for improvements, The model appears to predict good results with all the range of input properties and could be

  • PDF

초고분말 IGCC 플라이애시가 혼입된 프리팩트 그라우팅 몰드의 초기 강도 특성 (Initial strength charactistic of Prepacked Grouting Mold with IGCC Ultra-Fine Fly Ash)

  • 임창민;권현우;김영민;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.23-24
    • /
    • 2022
  • In this study, the Prepacked infilling mortar to which IGCC Ultra-Fine Fly Ash was added was evaluated when grouting aggregates. Efflux, Consistency, and Compressive Strength were measured, and it was found to have high fluidity when mixing IGCC Ultra-Fine Fly Ash, but the initial compressive strength was low

  • PDF

건물 내장재의 화재위험성 평가 방법 (A Fire Hazard Assessment of Interior Finish Materials)

  • 김운형
    • 한국화재소방학회논문지
    • /
    • 제12권2호
    • /
    • pp.17-28
    • /
    • 1998
  • 건물 화재시 예상되는 내장재의 실째 화재성농올 기준으로 한 위험성 명가방법올 제시하였다. 이률 위해 ISO Room Corner Test. (9705)를 기준으로 Qui ntie re의 화재확산 모델을 이용하여 내장재의 열 적 특성과 플래쉬 오버 도달시간과의 상관성을 유도하고 스쩨덴의 실제 시험결과와 비교 분석하였다. 이 결과, 내장재의 상대척인 화재위험성은 화재확산 변수 b륨 기준으로 명가될 수 있었다.

  • PDF

小型 디이젤機關에 있어서 알코올 利용에 관한 硏究

  • 노상순;허병무
    • 대한기계학회논문집
    • /
    • 제11권3호
    • /
    • pp.386-394
    • /
    • 1987
  • 본 연구에서는 우수한 출력성능 때문에 광범위한 범위에서 사용되고 있는 디 이젤기관을 그 대상으로 하여 실요상 보다 간편하고 액체연료만이 아니고 기체연료의 사용도 가능한 기화디이젤법, 즉 추연료로서 알코올을 흡기관으로부터 흡입시키는 한 편, 연소실내에 착화원으로서 경유를 분사시켜 알코올의 연소를 확보하도록 하는 방법 을 이용하여 기관의 연소성, 출력성능, 또는 배기특성 등에 대하여, 조사분석하여 알 코올이 대체연로로서의 이용가능성을 확고히 하고져 함에 그 목적이 있다.

APPLICATIONS OF A MODEL TO COMPARE AFLAME SPREAD AND BEAT RELEASE PROPERTIES OF INFERIOR FINISH MATERIALS IN A COMPARTMENT

  • Kim, Woon-Hyung;James G. Quintiere
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.193-200
    • /
    • 1997
  • Flame spread and heat release properties and incident heat flux of interior materials subject to an igniter heat flux in a compartment are investigated and compared by using computer model. A comer fire ignition source is maintained for 10 minutes at 100 kw and subsequently increased to 300kw. In executing the model, base-line material properties are selected and one is changed for each run. Also 4 different igniter heat flux conditions and examined. Results are compared for the 12 different materials tested by the ISO Room Comer Test (9705). The time for total energy release rate to reach 1MW is examined. The parameters considered include flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The model can show the importance of each property in causing fire growth on interior Hnish materials in a compartment. The effect of ignitor heat flux and material property effects were demonstrated by using dimensionless parameters a, b and Tb. Results show that for b greater than about zero, flashover time in the ISO Room-Corner test is principally proportional to ignition time and nothing more.

  • PDF

300MW급 IGCC를 위한 건식 분류층 석탄 가스화 공정의 동적 상태 모사 (The Process Simulation of Entrained Flow Coal Gasification in Dynamic State for 300MW IGCC)

  • 김미영;주용진;최인규;이중원
    • 한국수소및신에너지학회논문집
    • /
    • 제21권5호
    • /
    • pp.460-469
    • /
    • 2010
  • To develop coal gasfication system, many studies have been actively conducted to describe the simulation of steady state. Now, it is necessary to study the gasification system not only in steady state but also in dynamic state to elucidate abnormal condition such as start-up, shut-down, disturbance, and develop control logic. In this study, a model was proposed with process simulation in dynamic state being conducted using a chemical process simulation tool, where a heat and mass transfer model in the gasifier is incorporated, The proposed model was verified by comparison of the results of the simulation with those available from NETL (National Energy Technology Laboratory) report under steady state condition. The simulation results were that the coal gas efficiency was 80.7%, gas thermal efficiency was 95.4%, which indicated the error was under 1 %. Also, the compositions of syngas were similar to those of the NETL report. Controlled variables of the proposed model was verified by increasing oxygen flow rate to gasifier in order to validate the dynamic state of the system. As a result, trends of major process variables were resonable when oxygen flow rate increased by 5% from the steady state value. Coal flow rate to gasifier and quench gas flow rate were increased, and flow rate of liquid slag was also increased. The proposed model in this study is able to be used for the prediction of gasification of various coals and dynamic analysis of coal gasification.

플라즈마 방식 열분해 가스화용융시설의 공정별 클로로벤젠 및 클로로페놀 배출거동에 관한 연구 (A Study on the Chlorobenzene and Chlorophenol Behavior in Plasma Type Pyrolysis/Gasfication/Melting Process)

  • 신찬기;신대윤;김기헌;손지환
    • 환경위생공학
    • /
    • 제22권2호
    • /
    • pp.9-20
    • /
    • 2007
  • The incineration process has commonly used for wastes amount reduction and thermal treatments of pollutants as the technologies accumulated. However, the process is getting negative public images owing to matter of hazardous pollutants emission. Specially dioxins became a main issue and were mostly emitted from municipal solid wastes incineration. In this reason, pyrolysis/gasification/melting process is presented as an alternative of incineration process. The pyrolysis/gasification/melting process, a novel technology, is middle of verification of commercial plant and development of technologies in Korea. But the survey about the pollutant emission from the process, and background data in these facilities is necessary. So in this survey, t is investigated that the behavior of chlorobenzenes and chlorophenols in plasma type pyrolysis/gasification/melting plant of pilot scale. We investigated discharging behavior of each phase of chlorobenzene through each process in the plsasma type pyrolysis/gasification/melting process. From this result, it was found that about 99 percent of particle-phase chlorobenzene was removed, but on the other hand gas-phase chlorobenzene was increased by about 600 percent through heat exchanger, flue gas cooling, system and semi dry absorption bag filter(SDA/BF). Also, this investigation presented that di-chlorobenzene(DCB) tri-chlorobenzene(TCB), tetra-chlorobenzene(TeCB), penta-chlorobenzene (PCB), except mono-chlorobenzene(MCB) and hexa-chlorobenzene(HCB) were increased through the flue gas cooling system and the semi dry absorption bag filter(SDA/BF). It was investigated that concentration of particle-phase chlorophenol was decreased by about 66 percent, but on the other hand, concentration of gas-phase chlorophenol was increased by about 170 percent through heat exchanger, flue gas cooling system, and semi dry absorption bag filter(SDA/BF). Also, it was found that di-chlorophenol(DCP), tri-chlorophenol(TCP), and penta-chlorophenol(PCP) were increased through the flue gas cooling system, and the semi dry absorption bag filter(SDA/BF). It can be considered that small-scale pilot facility and short investigation period might cause the concentration increase through the flue gas cooling system and the semi dry absorption bag filter(SDA/BF). A further study on real-scale pilot facility and accurate investigation may be required.

사례분석을 통한 농촌형 저탄소 녹색마을 타당성 검토 (A Study on the Validity of Rural Type Low Carbon Green Village Through Case Analysis)

  • 도인환;황은진;홍수열;배재근
    • 대한환경공학회지
    • /
    • 제33권12호
    • /
    • pp.913-921
    • /
    • 2011
  • 본 연구는 저탄소 녹색마을을 Y군의 협조를 얻어 A, B, C마을에 설치한다는 전제에서 환경성, 경제성, 에너지자립도 등을 분석하여 종합적인 타당성을 검토하였다. 대상 바이오매스의 종류 및 양은 가축분뇨 28톤/일, 과수전정지 2톤/일로 하루 30톤 규모로 시설용량을 설정, 시설은 습식계(가축분뇨) 바이오매스를 이용한 바이오가스화 시설과 건식계(전정가지) 바이오매스를 이용한 화목보일러 시설, 열병합발전기, 퇴비화시설 등으로 구성하였다. 구성된 시스템을 운전하였을 때, 전기생산량은 540,540 kWh/년, 열에너지 생산량은 1,762 Gcal/년으로 분석되었다. 대상마을 가구(129가구)에서 기존에 사용하고 있는 전기에너지는 309,600 kWh/년으로 시설에서 생산된 전기에너지를 공급하면 대상지역의 전기에너지 자립률은 100%가 되며, 잉여전력은 230,940 kWh/년이었다. 또한 열에너지는 대상마을의 비닐하우스에서 소요되는 양을 산정하였으며, 기존 사용량 1,415 Gcal/년으로 열에너지 자립률 역시 100%가 되며, 잉여량은 347 Gcal/년이 되었다. 경제성은 시설설치비용 504,000만원, 운영비 48,509만원, 수익 33,712만원으로 연간 약 1억 4천만원 적자, 15년 동안 약 22억원의 적자이나, 환경성 분석에서 원유대체효과 약 178백만원, 온실가스감축효과 약 92백만원으로 연간 총 2억 7천만원의 환경적 편익이 발생되어, 종합적으로는 연간 약 1억 3천만원 정도의 편익이 발생되었다. 정부 및 지자체의 예산지원을 통하여 진행되더라도 경제성, 환경성, 에너지자립도를 종합하여 볼 때, 충분한 타당성이 있는 사업이라고 판단되었다.