• 제목/요약/키워드: gas transfer

검색결과 1,720건 처리시간 0.035초

직접접촉식 액화천연가스 기화기의 특성에 관한 연구 (A Study on Characteristics of Direct Contact LNG Evaporator)

  • 한승탁;김종보
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.903-911
    • /
    • 1994
  • This study addresses the phenomena of bubbling, icing, eruption, component varieties of the evaporated natural gas, and volumetric heat transfer coefficients obtained during the operation of a proposed LNG evaporator between LNG and water in direct contact. In the present investigation, the explosive and eruption phenomena within the water column were not observed during the entire operation of the heat exchanger. Compared with the natural gas produced by conventional LNG evaporator, the analysis of the gas produced by the direct contact LNG evaporator shows that nitrogen, methane, and ethane components were reduced by 0.002~0.007mol%(4~14%), 1.6~1.92mol%(1.9~2.3%) and 0.17~1.28mol%(1.1~8.4%) respectively, while the moisture content was rather increased by 0.51~0.76mol%. The maximum volumetric heat transfer coefficient of the direct contact heat exchanger was found to be $21, 800kW/m^3\cdotK$.

Air Lift Fermentor에서 Sisomicin 발효시에 발효유사액을 이용한 산소전달속도 예측 (Prediction of Oxygen Transfer Rate During Sisomicin Fermentation Employing Air Lift Fermentor)

  • 김성룡;신철수
    • 한국미생물·생명공학회지
    • /
    • 제22권6호
    • /
    • pp.659-664
    • /
    • 1994
  • In order to predict gas hold-up and oxygen transfer rate during sisomicin fermentation employing air lift fermentor, simulated media similar to fermentation broths in rheological proper- ties were prepared and used. Rheological properties of fermentation broths from 40 hours and 60 hours of cultivation were analyzed by applying to Power's Law equation. Regardless of addition and no addition of MgSO$_{4}$, the tendencies, that n value was decreased and K value was increased as aeration rate was increased, were shown. Simulated media of twelve different fermentation broths were formulated in a range of 0.7 to 2.1% CMC, and the values of gas hold-up and k$_{L}$a depending on superficial air velocity were measured using these simulated media. And the relation- ships, $\varepsilon$=$\alpha$U$_{Gr}$$\beta$, K$_{L}$a=$\gamma$U$_{Gr}$$\delta$ were obtained, and these equations are thought to be used to predict the values of gas hold-up and k$_{L}$a during fermentation.

  • PDF

Radiative Transfer Solutions for Purely Absorbing Gray and Nongray Gases Within a Cubical Enclosure

  • Kim, Tae-Kuk;Park, Won-Hee;Lee, Chang-Hyung
    • Journal of Mechanical Science and Technology
    • /
    • 제15권6호
    • /
    • pp.752-763
    • /
    • 2001
  • Although there are many different solution schemes proposed for multidimensional radiative transfer, reference solutions to benchmark these methods are very rare in the literature. In this paper we produced some accurate solutions for purely absorbing gray and nongray gases including H$_2$O and CO$_2$by using the discrete transfer method with sufficiently accurate T(sub)95 quadrature set. The spectral transmittances of the mixtures of H$_2$O and CO$_2$are estimated by using the narrow band model. The gray gas solutions are obtained for different absorption coefficients, and the nongray real gas solutions are obtained for different mixture fractions of H$_2$O and CO$_2$. The numerical solutions presented in this paper are proved to be sufficiently accurate as compared to the available exact solutions and they may be used as reference solutions in evaluating various solution schemes.

  • PDF

전사 인쇄에 의한 3차원 백금 다공성 다층구조 (Three-dimensional and Multilayered Structure Prepared by Area of Platinum Transfer Printing)

  • 정승재;최용호;조정호
    • 센서학회지
    • /
    • 제28권2호
    • /
    • pp.113-116
    • /
    • 2019
  • A three-dimensional porous structure was fabricated by pattern transfer printing for applications of electrodes in gas sensors. To form replica patterns, solutions were mixed with acetone, toluene, heptane, and poly(methyl methacrylate). These replica patterns can also be formed on substrates such as polyimide, polydimethylsiloxane, and silicon. The wide range of line widths from 1 to $5{\mu}m$ was derived from the surface grating patterns of master substrates. The cross-bar pattern with 40 layers showed a thickness of 600 nm. The area of platinum transferred patterns with different line widths was enhanced to $20{\times}25mm$, which is applicable to various electrode patterns of gas sensors.

알루미늄 호일 부착 발포 폴리스티렌 단열재의 열전도율, 열방출시험 및 가스 유해성 시험 (Heat Transfer Coefficient, Heat Release and Gas Hazard Tests for Expanded Polystyrene Heat Insulating Materials with Aluminum Foil)

  • 공하성
    • 대한안전경영과학회지
    • /
    • 제20권4호
    • /
    • pp.15-19
    • /
    • 2018
  • The purpose of this study is to enhance heat insulation effect and to decrease fire hazard by attaching aluminum foil to expanded polystyrene, which is mainly used for insulating materials, to have fire retardant. The result of the test confirmed that the insulating materials, expanded polystyrene of $10kg/m^3$ and $14kg/m^3$ of density attached aluminum foil on both sides, showed 12%, 14% of improved heat transfer coefficient respectively compared to existing expanded polystyrene of the same density. Besides, they met all the standards for the testing of heat release and gas hazard. On the other hand, the one made of general expanded polystyrene could not meet the standards of the heat release test and the gas hazard test.

Numerical Analysis of Hypersonic Shock-Shock Interaction using AUSMPW+ Scheme and Gas Reaction Models

  • Lee, Joon Ho;Kim, Chongam;Rho, Oh-Hyun
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제1권1호
    • /
    • pp.21-28
    • /
    • 2000
  • The flowfield of hypersonic shock-shock interaction has been simulated using a two-dimensional Navier-Stokes code based on AUSMPW+ scheme. AUSMPW+ scheme is a new hybrid flux splitting scheme, which is improved by introducing pressure-based weight functions to eliminate the typical drawbacks of AUSM-type schemes, such as non-monotone pressure solutions. To study the real gas effects, three different gas models are taken into account in the present paper: perfect gas, equilibrium flow and non equilibrium flow. It has been investigated how each gas model influences on the peak surface loading, such as wall pressure and wall heat transfer, and unsteady structure of flowfield in the region of shock-shock interaction. With the results, the value of peak pressure is not sensitive to the real gas effects nor to the wall catalyticity. However, the value of peak heat transfer rates is affected by the real gas effects and the wall catalyticity. Also, the structure of the flowfield changes drastically in the presence of real gas effects.

  • PDF

Investigation of condensation with non-condensable gas in natural circulation loop for passive safety system

  • Jin-Hwa Yang;Tae-Hwan Ahn;Hwang Bae;Hyun-Sik Park
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1125-1139
    • /
    • 2023
  • The system-integrated modular advanced reactor 100 (SMART100), an integral-type pressurized water small modular reactor, is based on a novel design concept for containment cooling and radioactive material reduction; it is known as the containment pressure and radioactivity suppression system (CPRSS). There is a passive cooling system using a condensation with non-condensable gas in the SMART CPRSS. When a design basis accident such as a small break loss of coolant accident (SBLOCA) occurs, the pressurized low containment area (LCA) of the SMART CPRSS leads to steam condensation in an incontainment refuelling water storage tank (IRWST). Additionally, the steam and non-condensable gas mixture passes through the CPRSS heat exchanger (CHX) submerged in the emergency cooldown tank (ECT) that can partially remove the residual heat. When the steam and non-condensable gas mixture passes through the CHX, the non-condensable gas can interrupt the condensation heat transfer in the CHX and it degrades CHX performance. In this study, condensation heat transfer experiments of steam and non-condensable gas mixture in the natural circulation loop were conducted. The pressure, temperature, and effects of the non-condensable gas were investigated according to the constant inlet steam flow rate with non-condensable gas injections in the loop.

가스터빈 블레이드 팁의 열전달과 유동 특성에 대한 수치적 해석 (Numerical Analysis of Heat Transfer and Flow Characteristics on Squealer Tip of Gas Turbine Blade)

  • 쟈오리우;강영석;김동화;조진수
    • 한국항공우주학회지
    • /
    • 제44권12호
    • /
    • pp.1062-1070
    • /
    • 2016
  • 본 연구에서는 전산해석을 통해 냉각 터빈 블레이드 팁 간극의 유동 및 열전달 특성을 연구하였다. 1단 고압터빈 노즐 출구에서 획득한 속도, 온도 프로파일을 로터의 입구에 적용하여 로터 도메인을 대상으로 전산해석을 하였다. 스퀼러 팁이 적용된 블레이드의 팁 간극을 스팬의 1%부터 2.5%로 조절하여 팁 간극의 공력 손실, 열전달 계수와 막냉각 효율의 영향을 고찰했다. 팁 간극이 커질수록 출구에서 공력 손실과 블레이드 끝단 표면에서 열전달 계수는 증가하였다. 특히 팁 간극이 스팬의 2%일 때 평균 열전달 계수가 급격히 증가하였다. 팁 영역의 막냉각 효율은 팁 간극이 작을수록 높았고, 캐비티 내부 냉각 홀 근처의 막냉각 효율이 높았다.

공정안전관리 사업장의 열매체유 사용실태에 관한 연구 (A Study on the Actual Status of Heat Transfer oils in Industries for Process Safety Management)

  • 이근원;이주엽
    • 한국가스학회지
    • /
    • 제18권5호
    • /
    • pp.33-39
    • /
    • 2014
  • 열매체유는 화학플랜트의 가열시스템, 열교환시스템, 특정한 가스공정, 사출성형 시스템 및 펄프 제지공정에 사용되고 있다. 열매체유는 열적 산화 분해에 잘 견디며 안전성이 뛰어나며, 열매체유가 누출이나 분출의 경우에는 점화원이 있을때 쉽게 점화된다. 본 연구에서는 공정안전관리 사업장의 화재 폭발 사고를 예방하기 위해서 열매체유의 사용 실태조사를 통해 안전관리 상태를 고찰하였다. 사업장의 공정시스템에서 사용된 열매체유의 사용실태는 개발된 설문지에 의해서 조사되었다. 본 연구 결과는 열매체유의 관리나, 열매체유 공정의 안전한 운전과 유지와 관련된 화재 폭발 사고 예방을 위한 안전관리 대책 수립에 활용될 수 있을 것이다.

내부순환반응기의 Scale-up에 따른 동력학적 특성의 변화 (Dynamic Behavior of an Internal Loop Reactor during Scale-up)

  • 최윤찬;박영식
    • 한국환경과학회지
    • /
    • 제6권1호
    • /
    • pp.25-31
    • /
    • 1997
  • The variations of gas hold-up, overall volumetric oxygen mass transfer coefficients and liquid circulation velocity in an internal loop reactor were investigated to manifest scale-up effect. The relationship between superficial gas velocity and gas hold-up were found as Ugr = 0.045 $\varepsilon$r in the pilot-scale and Ugr = 0.056 $\varepsilon$r in the bench-scale reactor. The overall volumetric oxygen mass tractsfer coefficient, KLa was slightly increased in the pilot-scale than in the bench-scale reactor. Flow regime was changed from the bubble flow to the churn-turbulent flow when the superficial gas velocity reached to 3.5 - 4 cm/sec in the pilot-scale.

  • PDF