• 제목/요약/키워드: gas transfer

검색결과 1,717건 처리시간 0.026초

단일액적연소현상에서 비회색체복사에 관한 연구 (Investigation of a droplet combustion with nongray gas radiation effects)

  • 최창은;박재현;박승욱
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1363-1370
    • /
    • 1997
  • Single liquid droplet combustion processes including heating, evaporation, droplet burning and flame radiation were theoretically investigated by adopting nongray gas radiation model for the radiative transfer equation (RTE). n-Heptane was chosen as a fuel and the numerical results were compared with the experimental data available in the literature. The discrete ordinate method (DOM) was employed to solve the radiative transfer equation and the weighted sum of gray gases model (WSGGM) was applied to account for nongray effect by CO$_{2}$, and H$_{2}$0. Therefore, detailed effects by nongray gas and its comparison with the gray gas model could be figured out in the results. It is found that the radiative heat flux is higher when the nongray model is used, thereby reducing the maximum gas temperature and the flame thickness, but the total burning time increases due to the deceased conductive heat flux in nongray model. Consequently, a better agreement with experimental data could be obtained by using nongray model.

적외선 센서용 극저온 용기의 냉각특성에 관한 실험적 연구 (An Experimental Study on the Cooling Characteristics of an Infrared Detector Cryochamber)

  • 강병하;이정훈;김호영
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.889-894
    • /
    • 2004
  • Infrared (IR) detectors are widely used for many applications, such as temperature measurement, intruder and fire detection, robotics and industrial equipment, thermoelstic stress analysis, medical diagnostics, and chemical analysis. Quantum detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal analysis of cryochamber includes the conduction heat transfer through a cold well, the gases conduction and gas outgassing, as well as radiation heat transfer, The transient cooling characteristics of an infrared detector cryochamber are investigated experimentally in the present study. The transient cooling load increases as the gas pressure is increased. Gas pressure becomes significant as the cooling process proceeds. Cool down time is also increased as the gas pressure is increased. It is also found that natural convection effects on cool down time become significant when the gas pressure is increased.

고점성 낮은표면장력 매체 기포탑에서 열전달 (Heat Transfer in Bubble Columns with High Viscous and Low Surface Tension Media)

  • 김완태;임대호;강용
    • Korean Chemical Engineering Research
    • /
    • 제52권4호
    • /
    • pp.516-521
    • /
    • 2014
  • 고점성이며 낮은 표면장력 매체로 구성된 기포탑에서 축방향 국부 열전달 계수와 총괄 열전달 계수에 대해 고찰하였다. 기체공탑유속(0.02~0.10 m/s), 액체 점도($0.1{\sim}0.3Pa{\cdot}s$) 그리고 액체 표면장력($66.1{\sim}72.9{\times}10^{-3}N/m$)이 국부 및 총괄 열전달 계수에 미치는 영향을 검토하였다. 열전달 영역은 기포탑 내부 열원과 기포탑 간의 열전달계로 구성하였다. 즉, 기포탑의 중앙에 수직 열원을 설치하여 내부 열원으로 하였다. 열전달 계수는 주어진 운전조건에서 열원에 제공되는 열량과 내부 열원과 기포탑 간의 온도차를 연속적으로 측정하여 결정하였다. 국부 열전달 계수는 기체공탑유속이 증가함에 따라 증가하였으나 기체 분산판으로 부터의 축방향 거리가 증가함에 따라, 액체의 표면장력이 증가함에 따라 감소하였다. 총괄 열전달 계수는 기체공탑유속이 증가함에 따라 증가하였으나 액상의 점도와 표면장력이 증가함에 따라서는 감소하였다. 총괄 열전달 계수는 기체공탑유속, 액상의 점도와 표면장력의 함수로 상관계수 0.91의 상관식을 얻을 수 있었으며 넛셀 수, 레이놀즈 수, 플란틀 수 그리고 웨버 수의 함수로 상관계수 0.92의 상관식으로 나타낼 수 있었다. $$h=2502U^{0.236}_{G}{\mu}^{-0.250}_{L}{\sigma}^{-0.028}_L$$ $$Nu=325Re^{0.180}Pr^{-0.067}We^{0.028}$$.

Experimental assessment of thermal radiation effects on containment atmospheres with varying steam content

  • R. Kapulla;S. Paranjape;U. Doll;E. Kirkby;D. Paladino
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4348-4358
    • /
    • 2022
  • The thermal-hydraulics phenomena in a containment during an accident will necessarily include radiative heat transfer (i) within the gas mixture due to the high radiative absorption and emission of steam and (ii) between the gas mixture and the surrounding structures. The analysis of some previous PANDA experiments (PSI, Switzerland) demonstrated the importance of the proper modelling of radiation for the benefit of numerical simulations. These results together with dedicated scoping calculations conducted for the present experiments indicated that the radiative heat transfer is considerable, even for a very low amount of steam (≈2%). The H2P2 series conducted in the large-scale PANDA facility at the Paul-Scherrer-Institut (PSI) in the framework of the OECD/NEA HYMERES-2 project is intended to enhance the understanding of thermal radiation phenomena and to provide a benchmark for corresponding numerical simulations. Thus, the test matrix was tailored around the two opposite extremes: either gas compositions with small steam content such that radiative heat transfer phenomena can be neglected. Or gas mixtures containing larger amounts of steam, so that radiative heat transfer is expected to play a dominant role. The H2P2 series consists of 5 experiments designed to isolate the radiation phenomena from convective and diffusive effects as much as possible. One vessel with a diameter of 4 m and a height of 8 m was preconditioned with different mixtures of air / steam at room and elevated temperatures. This was followed by the build-up of a stable helium stratification at constant pressure in the upper part of the vessel. After that, helium was injected from the top into the vessel which leads to an increase of the vessel pressure and a corresponding elevation-dependent and transient rise of the gas temperature. It is shown that even the addition of small amounts of steam in the initial gas atmosphere considerably impacts the radiative heat transport throughout all phases of the experiments and markedly influences i) the monitored gas peak temperature, ii) the temperature history during the compression and iii) the following relaxation phase after the compression was stopped. These PANDA experiments are the first of its kind conducted in a large scale thermal-hydraulic facility.

Investigations of Mixing Time Scales in a Baffled Circular Tank with a Surface Aerator

  • Kumar, Bimlesh;Patel, Ajey;Rao, Achanta
    • Environmental Engineering Research
    • /
    • 제16권1호
    • /
    • pp.47-51
    • /
    • 2011
  • The oxygen transfer rate is a parameter that characterizes the gas-liquid mass transfer in surface aerators. Gas-liquid transfer mechanisms in surface aeration tanks depend on two different extreme lengths of time; namely, macromixing and micromixing. Small scale mixing close to the molecular level is referred to as micromixing; whereas, macromixing refers to mixing on a large scale. Using experimental data and numerical simulations, macro- and micro-scale parameters describing the two extreme time scales were investigated. A scale up equation to simulate the oxygen transfer rate with micromixing times was developed in geometrically similar baffled surface aerators.

A Convective Heat Transfer Correlation for Turbulent Gas-Liquid Two-Phase Flow in Vertical Pipes

  • Kim, Dong-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.27-36
    • /
    • 2001
  • A new two-phase non-boiling convective heat transfer correlation for turbulent flow $(Re_{SL}>4000)$ in vertical tubes with different fluid flow patterns and fluid combinations was developed using experimental data available from the literature. The correlation presented herein originates from a careful analysis of the major non-dimensional parameters affecting two-phase heat transfer. This model takes into account the appropriate contributions of both the liquid and gas phases using the respective cross-sectional areas occupied by the two phases. A total of 255 data points from three available studies (which included the four sets of data) were used to determine the curve-fitted constants in the improved correlation. The performance of the new correlation was compared with two-phase correlations from the literature, which were developed for specific fluid combinations.

  • PDF

화염전달함수를 이용한 연소불안정 모델링 기법 소개 (Introduction to Combustion Instability Modeling Using Flame Transfer Function)

  • 김대식
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.71-72
    • /
    • 2014
  • The current paper introduce the flame transfer function calculation results using CFD in order to quantify the heat release fluctuations in a lean premixed gas turbine combustor. Comparisons of the modeled and measured flame shapes were made using the optimized heat transfer conditions.

  • PDF

혈관 내 신형 폐보조장치의 기체전달 및 용혈 특성 (Gas Transfer and Hemolysis Characteristics of a New Type Intravenous Lung Assist Device)

  • 김기범;권대규;정경락;이삼철
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권2호
    • /
    • pp.121-126
    • /
    • 2003
  • 본 연구는 진동형 장치의 활용을 통해 혈관 내 폐 보조장치의 기체전달 효율을 향상시키고자 시도하였으며, 진동에 따른 혈액의 용혈 문제에 있어서 한계 용혈이 발생하는 영역을 선정하고자 하였다. 가진 주파수가 0 Hz일 때를 기준으로 하여 중공사 수의 변화에 따라 산소전달속도를 측정하였다. 최대의 산소전달속도를 나타내는 중공사 모듈에서 가진 주파수의 변화에 따른 산소전달속도를 측정하고 혈액의 용혈도를 측정하였다. 측정결과 액체 유속의 변화에 따라 최대 산소전달속도를 나타내는 중공사 모듈은 type 6으로 이때의 중공사 개수는 675개이다. 또한, 중공사를 가진하지 않았을 때 최대의 산소전달속도를 보여주는 모듈은 type 6이었다. 모듈 type 6의 가진 주파수의 변화에 따른 산소전달속도는 7 Hz에서 최대산소전달속도를 나타내었으며 최대산소전달속도를 나타내는 7 Hz의 가진 주파수에서의 혈액 용혈도를 측정한 결과 혈액의 용혈도는 낮았다. 그러므로 최대 흔들림이 일어나는 7 Hz를 한계 용혈 주파수로 결정할 수 있었다.

固體分末 이 浮上된 二相亂流 管流動 의 熱傳達 解析 (Analysis of Turbulent Heat Transfer of Gas-Solid Suspension Flow In Pipes)

  • 김재웅;최영돈
    • 대한기계학회논문집
    • /
    • 제6권4호
    • /
    • pp.331-340
    • /
    • 1982
  • Numerical analysis is made on the turbulent heat transfer with suspension of solid particles in circular tube with constant heat flux. The mean motion of suspending particles in mixture is treated as the secondary gas flow with virtual density and viscosity. Our modeling of turbulent transport phenomena of suspension flow is based on this assumption and conventional mixing length theory. This paper gives the evidence that the mixing length models can be extended to close the governing equations for two phase turbulent flow with solid boundary at a first order level. Results on Nusselt numbers obtained by analytical treatments are compared with available experimental data and discussed. They suggest that the most important parameters of two phase turbulent heat transfer phenomena are relative particle diameter to pipe diameter, gas-solid loading ratio, and specific heat of suspending material.

충전탑에서 흡수에 따른 물질전달과 수력학적 거동에 관한 연구 (A Study on Hydraulic Behavior and Mass Transfer by Absorption in Packing Tower)

  • 김석택
    • 한국환경과학회지
    • /
    • 제9권5호
    • /
    • pp.393-396
    • /
    • 2000
  • Packing tower has been used in the chemical industry and the protection of environment for a long time. In the view of environmental protection purification of exhaust gas can be performance effective by gas absorption in counter-current packing tower. In this study characteristics of hydraulic and mass transfer were investigated in D. $0.3m {\times} H. 1.4m$ packing tower with 50mn plastic Hiflow-ring. This study was carried out "Test systems were experimented in conditions of Air, $Air/H_2O. NH_3-Air/H_2O, NH_3-Air/H_2O-H_2SO_4$ and $SO_2-Air/H_2O-NaOH$ under steady state" The extent of test included dry and wetting pressure drop physical law separation efficiency and hold-up as function of gas and liquid load.quid load.

  • PDF