• Title/Summary/Keyword: gas multiplication

Search Result 14, Processing Time 0.053 seconds

A Study of 2-dimensional X-ray Detector using Monte Carlo Simulation (몬테 카를로 시뮬레이션을 이용한 2차원 X-선 검출기에 대한 연구)

  • Shin, Hyoung-Sup;Lee, Hak-Jae;Lee, Ki-Sung;Kang, Jung-Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.4
    • /
    • pp.67-70
    • /
    • 2010
  • X-ray absorption rate and multiplication factor of X-ray detector were calculated with Garfield code. High Z (= atomic number) was important factor to increase the absorption rate but low Z is also important to increase the multiplication. Five different gas composition were examined under the condition of 1400 V bias and 400 um gap. Xe 100% gas showed the highest absorption rate and He 96% + isobutene 4% showed the highest multiplication.

CORRECTION OF GAS MULTIPLICATION UNIFORMITY OF X-RAY DETECTOR BY VOLTAGE COMPANSATION METHOD (전압 보상법에의한 X-선 검출기의 이득 보정)

  • 남욱원;최철성;문신행
    • Journal of Astronomy and Space Sciences
    • /
    • v.10 no.1
    • /
    • pp.86-93
    • /
    • 1993
  • We experiment of the method to obtain the uniform gas multiplication in multiwire proportional counter. The general techenique of anode wire connection for the high voltage supply could not secure the uniformity of multiplication because of the edge effect at the outer anode wires. We found that the variation of the multiplication could be corrected in the accuracy of $\pm$1.6% rms using the voltage compansation method.

  • PDF

Calculation of Primary Electron Collection Efficiency in Gas Electron Multipliers Based on 3D Finite Element Analysis (3차원 유한요소해석을 이용한 기체전자증폭기의 1차 전자수집효율의 계산)

  • Kim, Ho-Kyung;Cho, Min-Kook;Cheong, Min-Ho;Shon, Cheol-Soon;Hwang, Sung-Jin;Ko, Jong-Soo;Cho, Hyo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • Gas avalanche microdetectors, such as micro-strip gas chamber (MSGC), micro-gap chamber (MGC), micro-dot chamber (MDOT), etc., are operated under high voltage to induce large electron avalanche signal around micro-size anodes. Therefore, the anodes are highly exposed to electrical damage, for example, sparking because of the interaction between high electric field strength and charge multiplication around the anodes. Gas electron multiplier (GEM) is a charge preamplifying device in which charge multiplication can be confined, so that it makes that the charge multiplication region can be separate from the readout micro-anodes in 9as avalanche microdetectors possible. Primary electron collection efficiency is an important measure for the GEM performance. We have defined that the primary electron collection efficiency is the fractional number of electron trajectories reaching to the collection plane from the drift plane through the GEM holes. The electron trajectories were estimated based on 3-dimensional (3D) finite element method (FEM). In this paper, we present the primary electron collection efficiency with respect to various GEM operation parameters. This simulation work will be very useful for the better design of the GEM.

Development of the WSGGM with Gray Gas Regrouping and Application to the 3-Dimensional Radiative Transfer (회색가스재조합을 이용한 회색가스가중합법 개발 및 3차원 복사열전달에의 적용)

  • Kim Tae-Kuk;Park Won-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.101-109
    • /
    • 2006
  • The narrow band-averaged transmissivity of $CO_2-H_2O$ mixtures is expressed by multiplying the transmissivities of $CO_2\;and\;H_2O$. Applying the multiplication property of narrow band transmissivities for gas mixtures of $CO_2-H_2O$ of the narrow band based WSGGM (weighted sum of gray gases model), the number of gray gases, required for accurate representation of the absorption characteristics by using the narrow band based WSGGM, is significantly increased. To reduce the computational loads by reducing the number of gray gases, we propose a gray gas regrouping process where the gray gases used for .the WSGGM are regrouped into a specified number of groups according to the magnitudes of absorption coefficients. To evaluate the proposed WSGGM for gas mixtures, the radiative transfer problems through 3-dimensional gas media are considered. The radiative source terms and the radiative heat fluxes obtained by using the proposed method are fairly well compared to previous results obtained by using the SNB model and other models. The regrouping technique results in an excellent computational efficiency with minor loss of accuracy.

3-Dimensional Radiative Transfer Analysis by Using the Narrow Band Based WSGGM with a Gray Gas Regrouping Technique (회색가스 재조합에 의한 좁은밴드 회색가스가중합법을 이용한 3 차원 복사열전달 해석 연구)

  • Park, Won-Hee;Kim, Tae-Kuk;Son, Bong-Sei
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.284-289
    • /
    • 2003
  • The narrow band-averaged transmissivity of $CO_2-H_2O$ mixtures is expressed by multiplying the transmissivities of $CO_2$ and $H_2O$. Applying the multiplication property of narrow band transmissivities for gas mixtures of $CO_2-H_2O$, the number of gray gases, required for accurate representation of the absorption characteristics by using the narrow band based WSGGM, is significantly increased. To reduce the computational loads by reducing the number of gray gases, we propose a gray gas regrouping process where the gray gases used for the WSGGM are regrouped into a specified number of groups according to the magnitudes of absorption coefficients. To evaluate the proposed WSGGM for gas mixtures, the radiative transfer problems through three-dimensional gas media are considered. The radiative source terms and the radiative heat fluxes obtained by using the proposed method are fairly well compared to those obtained by using the SNB model. The regrouping technique results in an excellent computational efficiency with minor loss of accuracy.

  • PDF

Study on Regrouping of Gray Gases in spectral WSGGM for Arbitrary Mixtures of CO2 and H2O Gases (이산화탄소-수증기 혼합가스에 대한 파장별 회색가스가중합법에서 회색가스재조합에 대한 연구)

  • Park, Won-Hee;Kim, Tae-Kuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.2
    • /
    • pp.227-235
    • /
    • 2003
  • The WSGG-based narrow band model was employed to solve the radiative transfer equations along isothermal and non-isothermal paths through $CO_2-H_2O-N_2$ gas mixtures at 1 atm. When the WSGGM is applied for arbitrary gas mixtures by considering the multiplication property of transmissivity in overlapping bands, the number of gray gases is significantly increased. To reduce the computation time, three different regrouping methods for the gray gases are tested in obtaining the mean absorption coefficient for each gray gas group. Among them, the regrouping method by minimizing the regrouping error shows the best results. For the isothermal media, 10 gray gases show fairly good agreement with the results by statistical narrow band(SNB) model which are regarded as reference solutions. For non-isothermal media, 20 gray gases show good agreement with reference solutions.

Measurement of Linear Energy Spectra for 135 MeV/u Carbon Beams in HIMAC Using Prototype TEPC (프로토 타입 조직등가비례계수기의 중입자가속기연구소의 135 MeV/u 탄소 이온에 대한 선형에너지 스펙트럼 측정)

  • Nam, Uk-Won;Lee, Jaejin;Pyo, Jeonghyun;Park, Won-Kee;Moon, Bong-Kon;Lim, Chang Hwy;Moon, Myung Kook;Kitamure, Hisashi;Kobayashi, Shingo;Kim, Sunghwan
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.197-201
    • /
    • 2014
  • TEPC (Tissue Equivalent Proportional Counter) was usually used for high LET radiation dosimetry. We developed a prototype TEPC for micro-dosimetry in the range of $0.2{\sim}300 keV/{\mu}m$. And, the simulated site diameter of the TEPC is $2{\mu}m$, of similar size to a cell nucleus. For purposes of characterization the response for high LET radiation of the TEPC has been investigated under 135MeV/u Carbon ions in HIMAC (Heavy Ion Medical Accelerator). We determined the gas multiplication factor and measured the lineal energy spectrum [yd(y)] of 135 MeV/u Carbon ions. The value of the gas multiplication factor was 315 at 700 V bias voltage. As a result of the experiment, we could more understand the performance of the TEPC for high LET (Linear Energy Transfer) radiation. And the procedure of high LET radiation dosimetry using TEPC is established.

Performance Prediction of a Micro Gas Turbine Cogeneration System Using Correction Curves and its Applications (보정곡선을 이용한 마이크로가스터빈 열병합발전시스템의 성능예측과 활용)

  • Choi, Byeong Seon;Kim, Jeong Ho;Kim, Min Jae;Kim, Tong Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.27-35
    • /
    • 2016
  • The purpose of this study is to develop a method to predict the performance and economics of a micro gas turbine cogeneration system using performance correction curves. The variables of correction curves are ambient temperature, ambient pressure, relative humidity and load fraction. All of the values of correction factors were expressed as relative values with respect to design values at the ISO conditions. Once the correction curves are obtained, system performance can be predicted relatively easily compared to a detailed performance analysis method through a simple multiplication of the correction factors of various variables at any operating conditions. The predicted results using the correction curve method were compared with those by the detailed and more complex performance analysis in a wide operating range, and its feasibility was confirmed. To illustrate the usability of the correction curve method, the results of an economic analysis of a cogeneration system considering varying operating ambient condition and load was presented.

Analysis of the first core of the Indonesian multipurpose research reactor RSG-GAS using the Serpent Monte Carlo code and the ENDF/B-VIII.0 nuclear data library

  • Hartanto, Donny;Liem, Peng Hong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2725-2732
    • /
    • 2020
  • This paper presents the neutronics benchmark analysis of the first core of the Indonesian multipurpose research reactor RSG-GAS (Reaktor Serba Guna G.A. Siwabessy) calculated by the Serpent Monte Carlo code and the newly released ENDF/B-VIII.0 nuclear data library. RSG-GAS is a 30 MWth pool-type material testing research reactor loaded with plate-type low-enriched uranium fuel using light water as a coolant and moderator and beryllium as a reflector. Two groups of critical benchmark problems are derived on the basis of the criticality and control rod calibration experiments of the first core of RSG-GAS. The calculated results, such as the neutron effective multiplication factor (k) value and the control rod worth are compared with the experimental data. Moreover, additional calculated results, including the neutron spectra in the core, fission rate distribution, burnup calculation, sensitivity coefficients, and kinetics parameters of the first core will be compared with the previous nuclear data libraries (interlibrary comparison) such as ENDF/B-VII.1 and JENDL-4.0. The C/E values of ENDF/B-VIII.0 tend to be slightly higher compared with other nuclear data libraries. Furthermore, the neutron reaction cross-sections of 16O, 9Be, 235U, 238U, and S(𝛼,𝛽) of 1H in H2O from ENDF/B-VIII.0 have substantial updates; hence, the k sensitivities against these cross-section changes are relatively higher than other isotopes in RSG-GAS. Other important neutronics parameters such as kinetics parameters, control rod worth, and fission rate distribution are similar and consistent among the nuclear data libraries.

A thin film condition of material for AR and HR coating by the DC/RF Magnetron Sputter (DC/RF Magnetron Sputter를 이용한 무반사 및 고반사 박막증착)

  • Yang, Jin-Seok;Jo, Woon-Jo;Lee, Cheon;Kim, Dong-Woo;Shinn, Chun-Kyo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.206-209
    • /
    • 2003
  • The purpose of AR and HR coating is acquire the very low reflection rate and the high reflection rate through the deposition of a thin film using the refraction ofmaterial. Basically if the high refractive material and the low refractive material are chosen and the condition for the experiment is determined, then we solve theproject with the optical design and multi thin film coating. First of all, we choose $SiO_2$for the low refractive material and $TiO_2$ for the high refractive material and apply Sputtering System easy to control the refraction rate and excellent in reconstruction to the equipment of thin film multiplication. For the control of the refraction rate and growth rate we modify RF Power and the ratio of Gas(Ar:O2), And we use Ellipsometer for estimation and analysis of the refraction rate and growth rate and AFM&SEM for the analysis of surface and component.

  • PDF