• Title/Summary/Keyword: gas monitoring

Search Result 1,029, Processing Time 0.027 seconds

Variations of Temperature, Chemical Component and Helium Gas of Geothermal Water by Earthquake Events in Pohang Area (포항 지열수의 지진에 의한 수온, 화학성분 및 헬륨가스의 변화)

  • Lee, Yong Cheon;Jeong, Chan Ho;Lee, Yu Jin;Kim, Young-Seog;Kang, Tae-Seob
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.647-658
    • /
    • 2021
  • In this study, the change of temperature, chemical composition, and helium gas of thermal water in Pohang area was observed from January 2018 to June 2019 in order to interpret the relationship with earthquake events. During observation period earthquakes above M 2.0 within 100 km in a radius from a geothermal well occurred 58 including two earthquake events with a magnitude of 3.0~3.9 and two earthquake events with a magnitude of 4.0~4.9. We introduce a q-factor and earthquake effectiveness (ε) to express the influence of each earthquake as magnitude and distance factors. The geothermal well of 715 m deep was developed in the Bulguksa biotite granite, and the water temperature was observed in the variation from 51.8 to 56.3℃ during monitoring period. At M 4.1 and M 4.6 earthquake events, the increase of geothermal water temperature (𝜟T 2.6~4.5℃) was recorded, and slight change in specific ionic components such as SO4 and Cl, and of chemical types on the Piper diagram were observed. In the 3He/4He vs 4He/20Ne diagram, the original mixing ratio of helium isotope before and after the magnitude 4.1 earthquake was slightly changed from 83.0% to 83.2% of crust-origin 4He, and the from 16.3% to 16.7% of mantle-origin 3He. Hot-cold water mixing ratio before and after earthquakes by using the quartz and chalcedony solubility curves of the silica-enthalpy mixing model was calculated to interpret the temperature change of geothermal water. The model calculation shows the increase of 6.93~7.72% and 1.65~4.94% of hot water ratio at E1 and E2 earthquakes, respectively. Conclusively, the magnitude of earthquake for observable change in the temperature and helium isotope of thermal water is of 4.1 or higher and q-factor value of 30.0 or higher in the study site.

Establishment of Analytical Method for Dichlorprop Residues, a Plant Growth Regulator in Agricultural Commodities Using GC/ECD (GC/ECD를 이용한 농산물 중 생장조정제 dichlorprop 잔류 분석법 확립)

  • Lee, Sang-Mok;Kim, Jae-Young;Kim, Tae-Hoon;Lee, Han-Jin;Chang, Moon-Ik;Kim, Hee-Jeong;Cho, Yoon-Jae;Choi, Si-Won;Kim, Myung-Ae;Kim, MeeKyung;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.3
    • /
    • pp.214-223
    • /
    • 2013
  • BACKGROUND: This study focused on the development of an analytical method about dichlorprop (DCPP; 2-(2,4-dichlorophenoxy)propionic acid) which is a plant growth regulator, a synthetic auxin for agricultural commodities. DCPP prevents falling of fruits during their growth periods. However, the overdose of DCPP caused the unwanted maturing time and reduce the safe storage period. If we take fruits with exceeding maximum residue limits, it could be harmful. Therefore, this study presented the analytical method of DCPP in agricultural commodities for the nation-wide pesticide residues monitoring program of the Ministry of Food and Drug Safety. METHODS AND RESULTS: We adopted the analytical method for DCPP in agricultural commodities by gas chromatograph in cooperated with Electron Capture Detector(ECD). Sample extraction and purification by ion-associated partition method were applied, then quantitation was done by GC/ECD with DB-17, a moderate polarity column under the temperature-rising condition with nitrogen as a carrier gas and split-less mode. Standard calibration curve presented linearity with the correlation coefficient ($r^2$) > 0.9998, analysed from 0.1 to 2.0 mg/L concentration. Limit of quantitation in agricultural commodities represents 0.05 mg/kg, and average recoveries ranged from 78.8 to 102.2%. The repeatability of measurements expressed as coefficient of variation (CV %) was less than 9.5% in 0.05, 0.10, and 0.50 mg/kg. CONCLUSION(S): Our newly improved analytical method for DCPP residues in agricultural commodities was applicable to the nation-wide pesticide residues monitoring program with the acceptable level of sensitivity, repeatability and reproducibility.

Monitoring of Polycyclic Aromatic Hydrocarbons in Sediments and Organisms from Korean Coast

  • Moon Hyo-Bang;Choi Hee-Gu;Kim Sang-Soo;Jeong Seung-Ryul;Lee Pil-Yong;Ok Gon
    • Fisheries and Aquatic Sciences
    • /
    • v.4 no.4
    • /
    • pp.219-228
    • /
    • 2001
  • Surface sediments (0- 5 cm), mussels (Mytilus coruscus and M. edulis) and oysters (Crassostrea gigas) were sampled at 20 stations in Korean coast during a period of February to July 2000. Samples were analyzed for polycyclic aromatic hydrocarbons (PAHs) content using gas chromatography coupled to mass spectrometer detector (GC/MSD). The sediment $\sum PAH$ concentration varied from 7 to 1,214 ng/g dry weight and the level of carcinogenic PAHs of six species ranged from 1 to 563 ng/g dry weight in surface sediments. In organisms, the levels of $\sum PAH$ were in the range of 63-876 ng/g dry weight and the concentrations of carcinogenic PAHs of six species were in the range of 4-582 ng/g dry weight. The highest PAH concentrations in sediments and organisms were in samples from Station 5 in Pohang coast and Station 8 in Jinhae coast, respectively. $\sum PAH$ concentrations in sediments and organisms collected from Korean coast were slightly low or comparable to those in other countries. The contribution of ring aromatic groups to sum of 16 PAHs in sediments and organisms showed a similar pattern for most stations. In sediments, the predominant contributions were four and five ring aromatics like fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene and benzo[a]pyrene. In the organisms, four ring aromatics like fluoranthene, pyrene, benzo[a]anthracene and chrysene were predominant PAH species. Several molecular indices such as phenanthrene/anthracene, fluoranthene/pyrene and LMW/HMW ratio were used to identify the origin of PAH contamination in sediments. The results indicate that PAHs of Korean coast were mainly of pyro1ytic contaminants with slight petrogenic input. A high correlation within individual PAH compound in marine sediments was observed, while correlation in organisms showed a highly significant relationship for heavier molecular weight PAHs.

  • PDF

Performance Evaluation of Wireless Sensor Networks in the Subway Station of Workroom (지하철 역사내 기능실에 대한 무선 센서 네트워크 성능 분석)

  • An, Tea-Ki;Shin, Jeong-Ryol;Kim, Gab-Young;Yang, Se-Hyun;Choi, Gab-Bong;Sim, Bo-Seog
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1701-1708
    • /
    • 2011
  • A typical day in the subway transportation is used by hundreds of thousands are also concerned about the safety of the various workrooms with high underground fire or other less than in the subway users could be damaging even to be raised and there. In 2010, in fact, room air through vents in the fire because smoke and toxic gas accident victims, and train service suspended until such cases are often reported. In response to these incidents in subway stations, even if the latest IT technology, wireless sensor network technology and intelligent video surveillance technology by integrating fire and structural integrity, such as a comprehensive integrated surveillance system to monitor the development of intelligent urban transit system and are under study. In this study, prior to the application of the monitoring system into the field stations, authors carried out the ZigBee-based wireless sensor networks performance analyzation in the Chungmuro station. The test results at a communications room and ventilation room of the station are summarized and analyzed.

  • PDF

Evaluation of QuEChERS Method for Determination of pesticide Residues Using GC/NPD and GC/ECD (GC/NPD와 GC/ECD를 이용한 잔류농약 정량 분석법으로써의 QuEChERS의 평가)

  • Cho, Tae Hee;Park, Young Hye;Park, Hye Won;Hwang, Lae Hwong;Cho, In Soon;Kim, Min Jung;Kim, Hyun Jeong;Kim, Mu Sang;Chae, Young Zoo
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.1
    • /
    • pp.65-71
    • /
    • 2013
  • The modified QuEChERS method was evaluated for rapid determination of pesticide residues in spinach by gas chromatography-nitrogen phosphorous detector (NPD) and electron capture detector (ECD). Fifty GC-amenable pesticides which were most frequently detected in monitoring were selected in the current study. Matrix-matched calibration was performed. The detector response for all pesticides was linear with determination coefficients higher than 0.995. LODs for most compounds ranged between 0.001 and 0.1 ug/g, and about 90% of the compounds had LODs of less than 0.05 ug/g. LOQs ranged from 0.001 to 0.32 ug/g, which were well below the MRLs permitted for most of pesticides. In the majority of cases, the recoveries (80-120%) and relative standard deviations (RSDs) (less than 20%) were within acceptable levels except for dichlorvos, propamocarb, chlorothalonil, dichlofluanid, cyhalothrin and fenvalerate. Also, this method which is applied to routine samples showed good results when comparing with traditional multi-residue method.

Interference of Sulphur Dioxide on Balloon-borne Electrochemical Concentration Cell Ozone Sensors over the Mexico City Metropolitan Area

  • Kanda, Isao;Basaldud, Roberto;Horikoshi, Nobuji;Okazaki, Yukiyo;Benitez-Garcia, Sandy-Edith;Ortinez, Abraham;Benitez, Victor Ramos;Cardenas, Beatriz;Wakamatsu, Shinji
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.162-174
    • /
    • 2014
  • An abnormal decrease in ozonesonde sensor signal occurred during air-pollution study campaigns in November 2011 and March 2012 in Mexico City Metropolitan Area (MCMA). Sharp drops in sensor signal around 5 km above sea level and above were observed in November 2011, and a reduction of signal over a broad range of altitude was observed in the convective boundary layer in March 2012. Circumstantial evidence indicated that $SO_2$ gas interfered with the electrochemical concentration cell (ECC) ozone sensors in the ozonesonde and that this interference was the cause of the reduced sensor signal output. The sharp drops in November 2011 were attributed to the $SO_2$ plume from Popocat$\acute{e}$petl volcano southeast of MCMA. Experiments on the response of the ECC sensor to representative atmospheric trace gases showed that only $SO_2$ could cause the observed abrupt drops in sensor signal. The vertical profile of the plume reproduced by a Lagrangian particle diffusion simulation supported this finding. A near-ground reduction in the sensor signal in March 2012 was attributed to an $SO_2$ plume from the Tula industrial complex north-west of MCMA. Before and at the time of ozonesonde launch, intermittent high $SO_2$ concentrations were recorded at ground-level monitoring stations north of MCMA. The difference between the $O_3$ concentration measured by the ozonesonde and that recorded by a UV-based $O_3$ monitor was consistent with the $SO_2$ concentration recorded by a UV-based monitor on the ground. The vertical profiles of the plumes estimated by Lagrangian particle diffusion simulation agreed fairly well with the observed profile. Statistical analysis of the wind field in MCMA revealed that the effect Popocat$\acute{e}$petl was most likely to have occurred from June to October, whereas the effect of the industries north of MCMA, including the Tula complex, was predicted to occur throughout the year.

Step Count Detection Algorithm and Activity Monitoring System Using a Accelerometer (가속도 센서를 이용한 보행 횟수 검출 알고리즘과 활동량 모니터링 시스템)

  • Kim, Yun-Kyung;Lho, Hyung-Suk;Cho, We-Duke
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.2
    • /
    • pp.127-137
    • /
    • 2011
  • We have developed a wearable device that can convert sensor data into real-time step counts and activity levels. Sensor data on gait were acquired using a triaxial accelerometer. A test was performed according to a test protocol for different walking speeds, e.g., slow walking, walking, fast walking, slow running, running, and fast running. Each test was carried out for 36 min on a treadmill with the participant wearing a portable gas analyzer (K4B2), an Actical device, and the device developed in this study. The signal vector magnitude (SVM) was used to process the X, Y, and Z values output by the triaxial accelerometer into one representative value. In addition, for accurate step-count detection, we used three algorithms: an heuristic algorithm (HA), the adaptive threshold algorithm (ATA), and the adaptive locking period algorithm (ALPA). A regression equation estimating the energy expenditure (EE) was derived by using data from the accelerometer and information on the participants. The recognition rate of our algorithm was 97.34%, and the performance of the activity conversion algorithm was better than that of the Actical device by 1.61%.

Analytical Determination of Vitamin B12 Content in Infant and Toddler Milk Formulas by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

  • Lee, Jung-Hoon;Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.35 no.6
    • /
    • pp.765-771
    • /
    • 2015
  • The development of a sample preparation method and optimization of the analytical instrumentation conditions were performed for the determination of the vitamin B12 content in emulsified baby foods sold on the Korea market. After removal of the milk protein and fats by chloroform extraction and centrifugation, the vitamin B12 was water extracted from the sample. Following filtration of the solution through a nylon filter, the water-soluble extract was purified by solid-phase extraction using a Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS). The solution eluted from the cartridge was dried under a stream of nitrogen gas and reconstituted with 1 mL of water. The sample solution was injected into an LC-MS/MS system after optimizing the mobile phase for vitamin B12 detection. The calibration curve showed good linearity with the coefficient of correlation (r2) value of 0.9999. The limit of detection was 0.03 µg/L and the limit of quantitation was 0.1 µg/L. The method of detection limit was 0.02 µg/kg. The vitamin B12 recovery from a spiking test was 99.62% for infant formula and 99.46% for cereal-based baby food. The sample preparation method developed in this study would be appropriate for the rapid determination of the vitamin B12 content in infant formula and baby foods with emulsified milk characteristics. The ability to obtain stable results more quickly and efficiently would also allow governments to exercise a more extensive quality control inspection and monitoring of products expected to contain vitamin B12. This method could be implemented in laboratories that require time and labor saving.

Electronic Spectroscopy of Protonated Tyr-Ala Dipeptide Ions (Tyr-Ala 펩타이드 이온의 전자전이 분광 연구)

  • Choi, Chang-Min;Kwon, Jang-Sook;Kim, Hwan-Jin;Yoon, Tae-Oh;Yang, Min-O;Kim, Nam-Joon
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.4
    • /
    • pp.318-323
    • /
    • 2007
  • Electronic photofragmentation spectrum of protonated tyrosine-alanine dipeptide ions(YAH+) was obtained in the wavenumber region of 34500~36700 cm-1 using a quadrupole ion trap time-of-flight mass spectrometer (QIT-TOFMS). YAH+ ions were produced by electrospray ionization, stored in the ion trap and then irradiated by ultraviolet laser pulses which induced photofragmentation of the ions. The electronic photofragmentation spectrum was obtained by monitoring the photodissociation yields of YAH+ ions as a function of the laser wavelength. The spectrum exhibited two broad peaks which were assigned as S1 and S2 by theoretical calculations using a time-dependent density functional method. The broad widths of the peaks in the spectrum were explained by the overlaps of the peaks originated from various conformers of YAH+ ions which were present in the gas phase at room temperature and also by the contributions of the hot bands.

Exposure Assessment of PCDD/Fs and Monitoring of Health Effects on Workers and Resident near the Waste Incinerators in Korea (국내 일부 소각장 근로자와 주변지역주민들의 PCDDs/Fs 노출과 건강 영향 평가)

  • Hong, Yun-Chul;Lee, Kwan-Hee;Kwon, Ho-Jang;Jang, Jae-Yeon;Leem, Jong-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.4
    • /
    • pp.314-322
    • /
    • 2003
  • Objectives : In this study, the exposure status of the hazardous substances from incinerators, such as polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), were studied , and the relationship between the exposure of these hazardous substances and their heath effects on the workers and residents near municipal solid waste (MSW) incinerators and an industrial incinerator investigated. Methods : Between July 2001 and Jure 2002, 13 workers at two MSW incinerators, 16 residents from the area around the two MSW incinerators, 6 residents from the control area, and further 10 residents near an industrial incinerator, estimated to emit higher levels of hazardous substances, were interviewed. Information, including sociodemographic information, personal habits, and work history, detailed gynecologic and other medical history were collected through interviews. Blood samples were also collected from 45 subjects, and analyzed for PCDD/DFs, by high resolution gas chromatography -high resolution mass spectrometry, using the US EPA 1613 method. In addition to the questionnaire survey, urinary concentrations of 8-hydroxydeoxyguanosine (8-OH-dG) and malondialdehyde (MDA) were measured as oxidative injury biomarkers. The urinary concentrations of 8-OH-dG were determined by in vitro ELISA, and the MDA by HPLC, using u adduct with thiobarbituric acid. Results : The PCDD/DFs concentrations in the residents near the industrial incinerator were higher than those in the controls, workers and residents near the MSW incinerators. The average TEQ (Toxic Equivalencies) concentrations of the PCDD/DFs in residents near the industrial incinerator were 53.4pg I-TEQs/g lipid. The estimated daily intakes were within the tolerable daily intake range (1-4 pg I-TEQ/Kg bw/day) suggested by WHO (1997) in only 30% to the people near the industrial incinerator. Animal studies have already shown that even a low body border of PCDD/DFs, such as 10 ng TEQ/kg bw, can cause oxidative damage in laboratory animals. Our study also showed that the same body burden of PCDD/DFs can cause oxidative damage to humans. Conclusions : The exposures to PCDD/DFs and the oxidative stress of residents near the industrial incinerator, were higher than those in the controls, workers and residents near the MSW incinerators. Proper protection strategies against these hazardous chemicals are needed. Because a lower body burden of PCDD/Fs, such as 10ng TEQ/kg bw, can cause oxidative damage, the tolerable daily intake range should be restrictedly limited to 1pg I-TEQ/kg bw/day.