• Title/Summary/Keyword: gas monitoring

Search Result 1,029, Processing Time 0.029 seconds

Awareness during general anesthesia despite simultaneous bispectral index and end-tidal anesthetic gas concentration monitoring

  • Lee, Jungwon;Park, Chorong;Kim, Saeyoung
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.1
    • /
    • pp.50-53
    • /
    • 2019
  • Awareness during general anesthesia occurs in approximately 0.1-0.2% of cases; nevertheless, particular attention is required because it can lead to critical complications including insomnia, depression, anxiety, and post-traumatic stress disorder. To prevent these complications, bispectral index (BIS) and end-tidal anesthetic gas (ETAG) concentration monitoring are commonly used to examine patient consciousness during surgery. In the present case, an 80-year-old man was scheduled for total gastrectomy. Anesthesia was maintained using desflurane 4.0-5.0% vol, oxygen, and nitrous oxide. The authors simultaneously monitored BIS, which was maintained between 37 and 43, and ETAG, which was maintained between 0.9 and 1.2 minimum alveolar concentration (MAC). After the operation, however, the authors were surprised to learn that the patient complained of awareness during anesthesia. Although BIS and ETAG concentration monitoring are useful in preventing awareness during anesthesia, they cannot be completely trusted. Even though BIS was maintained at approximately 40 and ETAG at 0.7-1.3 MAC, awareness during anesthesia occurred.

Design of CIM(Common Information Model) Profile for Smart City Energy Monitoring (스마트시티 에너지 감시를 위한 CIM(Common Information Model) 프로파일 설계)

  • Youngil, Kim;Changhun, Chae;Yeri, Kim;Jihoon, Lee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.127-135
    • /
    • 2022
  • With the advent of high technologies such as the 4th Industrial Revolution and artificial intelligence and big data, efforts are being made to solve urban problems and improve the quality of life by applying new technologies in the smart city field. In addition, as carbon neutrality has emerged as an important issue due to global warming, smart city energy platform technologies such as urban energy management, efficiency improvement, and carbon reduction are in the spotlight. In order to effectively manage urban energy, energy resource information such as electricity, water, gas, hot water, heating, etc. must be collected from the management system of various energy utilities and managed on the central platform. The centrally integrated data is delivered to external city management systems that require city energy information through an energy platform. This study developed a CIM profile for smart city energy monitoring required to provide energy data to external systems. Electric data model were designed using the CIM class of IEC 61970, and water, gas, and heat data model were designed in compliance with the UML-based design ideas of IEC 61970.

Suggestions for the Estimation of the Methane Emission from a Landfill Site

  • Lee, Kyungho;Jeon, Eunjeong;Lee, Youngmin;Park, Junghyun
    • Journal of Urban Science
    • /
    • v.9 no.1
    • /
    • pp.69-73
    • /
    • 2020
  • Sudokwon landfill("Sudokwon" means regions of Seoul, Kyunggi and Incheon metropolitan cities in Korea), the world's largest sanitary landfill, has been systematically managing statistics on the incoming and dumping wastes and satisfactorily controlling pollutants including leachate and LFG. According to our long time experience of LFG field monitoring, the emission of GHG from landfill estimated by the IPCC Guideline showed much difference with our results. C&D waste has high concentration of sulfate compared to other wastes. Increased C&D waste of dumping waste had changed the COD/sulfate ratio in the landfill, which caused the increase of H2S gas and the decrease of CH4 gas. But the IPCC estimation method does not consider the effects of sulfate. In addition to that, the oxidation factor of the cover soil is set to the default values of 0.1 but the measured values by the field monitoring, are showing much higher than that, especially in the closed landfill.

State of The Art of Offshore Survey Technology for Monitoring Underwater Gas Export Pipeline Installation at DongHae-1 Gas Field (동해-1 가스전 해저배관 설치공사에 적용된 최신 해양 측량기술)

  • Park, Joseph
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.722-740
    • /
    • 2005
  • 본 논문은 최근의 석유탐사 및 개발사업 현장에서 사용되고 있는 최신의 측량기술 및 해양공사의 측량 기술 표준화 동향을 소개하고, 이에 기반하여 동해1 가스전 해저배관 공사에 적용한 사례를 기술하였다. 해저배관 시설공사를 수행하기 위한 사전측량 및 시공지원 측량은 다양한 탐사장비가 동원되며, 각 장비들의 운영, 자료처리, 해석, 도면화를 위하여 실시간지원이 가능한 시스템을 운영하는 기술이 요구된다. 이를 위하여 해저배관 시공단계별(Pre-Installation Survey, Touch-down Monitoring, As-laid As-Built Survey, Post-installation Survey) 요구되는 측량성과 및 이를 획득하기 위한 소해측량 시스템의 성능평가 및 정확도 분석을 수행하였다. 또한, 해저지형 탐사를 위해 동원된 소해측량시스템(Swath Sonar System)에서 취득되는 수심(Bathymetry) 및 후방산란 음압(Backscattered Amplitude) 자료를 맵핑하여 해저배관의 설치 경로를 측량하는 기법에 대하여 소개하고, 추후 해저배관 보호 및 관리시의 효율적인 모니터링 기법을 제시한다.

  • PDF

불포화 토양내에서 가스상 오존 측정을 위한 광섬유센서의 적용

  • 정해룡;최희철
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.111-114
    • /
    • 2003
  • A new monitoring system has been developed for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone was obtained by converting the normalized intensity into ozone concentration. The FOTDP system reflected the ideal transport phenomena of gas phase ozone at various flow rates. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of SOM. However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

  • PDF

Comparative Studies on Two Types Derivatives of Gibberellins for the Gibberellin Analysis by Gas Chromatography-Selected Ion Monitoring (GC-SIM에 의한 두종의 gibberellin유도체의 분석)

  • Park, Keun-Hyung
    • Applied Biological Chemistry
    • /
    • v.28 no.2
    • /
    • pp.82-87
    • /
    • 1985
  • Aiming at the improvement of accuracy and sensitivity of gibberellin analysis by gas chromatography-selected ion monitoring (GC-SIM), the mass spectra of two types of 29 gibberellin derivatives, methyl ester-trimethylsilyl ethers and trimethylsilyl ester-trimethylsilyl ethers, were obtained and their advantages and disadvantages in GC-SIM analysis are discussed.

  • PDF

Development of an Architecture Monitoring System Using Wireless Sensor Network (무선 센서네트워크를 이용한 건축물 모니터링 시스템 구현)

  • Chang, Hyung-Jun;Kim, Beom-Soo;Kong, Young-Bae;Park, Gwi-Tae;Shim, II-Joo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.6
    • /
    • pp.568-573
    • /
    • 2007
  • Environmental information (temperature, humidity, vibration, $CO_2$, gas leakage, etc.) of building is an essential item to manage and monitor a building. For intelligent building, it is necessary to get temperature and illumination information to save energy and crack information to prevent structural problems. Moreover, temperature and gas leakage information to alarm a tire precaution, or humidity information to maintain comfortable environment. However, there have not been many researches on systems for gathering environmental information and building maintenance due to high costs. In this paper, wireless sensor network technology is applied to collecting building environmental information. Wireless sensor network is one of the latest issues and has low-power consumption, low-cost, self-configuration features.

On-line UHF partial discharge monitoring system for Gas- insulated switchgears (GIS) (가스절연개폐장치 고장예방을 위한 UHF 부분방전 상시 감시 시스템)

  • Choi, Jae-Ok;Kim, Young-Ro;Hwang, Chul-Min;Lee, Young-Sang;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2066-2068
    • /
    • 2005
  • We developed an on-line Ultra-high frequency partial discharge monitoring system to prevent a catastrophic failure of gas- insulated switchgears. The system has been tested in the laboratory for detection of various UHF PD signals. We also performed detection sensitivity verification tests and compared them with conventional IEC60270 method.

  • PDF

The implementation of liquefaction equipment monitoring system based on Android (안드로이드 기반의 유증기 액화장치 모니터링 시스템 구현)

  • Park, Man-Kyu;Tack, Han-Ho;Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.3
    • /
    • pp.583-589
    • /
    • 2016
  • Volatile organic compounds(VOCs) are regarded as a harmful cause substance not only causing air pollutions but also causing global warming phenomenon. For this reason, VOCs are managed politically to reduce emissions by each country. In particular, the vapor from the gas station contains VOCs which is harmful to the human body such as carcinogens benzene and pollute the atmosphere, the Ministry of Environment defined every gas station must install vapor recovery equipment to recover volatile organic compounds. Recently, there are many accidents caused by existing vapor treatment methods, the liquefaction recovery technology is getting the spotlight to cool the vapor at the field. However, because the liquefaction recovery technology have risks of fire or explosion in accordance with temperature, the real time monitoring is critical factor. In this paper, we implement an Android-based monitoring application for liquified vapor recovery device which attached sensor module for temperature and power to monitoring real time information.

Development of Wireless Communication Based Operation State Monitoring System for Open Rack Vaporizer (무선 통신 기반 해수식 기화기 운영 상태 모니터링 시스템 개발)

  • Yoo, Seung-Yeol;Joen, Ming-Sung;Lee, Jae-Chul;Kang, Dong-Hoon;Kim, Dong-Goen;Lee, Soon-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.5
    • /
    • pp.280-287
    • /
    • 2022
  • An open rack vaporizer is a facility that vaporizes liquefied natural gas using sea water. When a vaporization efficiency of the open rack vaporizer decreases, liquefied natural gas can leak, which can cause great damage to the facility. Operators have to monitor the operation state of the facility in real-time to prevent the accident. However, operators have visited the site and have checked the state by looking at the value of sensors installed in the open rack vaporizer through indicators. For the safe operation of the open rack vaporizer, a monitoring system is needed to monitor the operation state of the open rack vaporizer in real-time without the need for operators to visit the site. In this paper, we developed a long term evolution based monitoring system to monitor the operation state of the open rack vaporizer. The developed system can monitor the real-time operation state of the open rack vaporizer at a control center far from the facility. For the system development, data transmission infrastructure using long term evolution was built. Afterwards a software was developed to monitor the operation state of the open rack vaporizer in real-time using the transmitted data. Finally, performance evaluation was conducted to confirm that the developed system operated successfully without data transmission delay or data missing.