• Title/Summary/Keyword: gas leakage scenarios

Search Result 36, Processing Time 0.023 seconds

A Study on the Analysis of the Leakage Characteristics and the Selection of Leakage Scenarios of the Blending Hydrogen into Natural Gas Pipeline (수소혼입 천연가스 배관망의 누출 특성 분석 및 누출 시나리오 선정에 관한 연구)

  • Song Su Tak;Ki Seop Lim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.27-32
    • /
    • 2024
  • This study analyzed cases of hydrogen (H2) and natural gas (CH4) leakage from a hydrogen-blended natural gas pipeline to determine a range of leakage characteristics, including leakage type, pipe material, pipe diameter, pressure, and damage size. Based on the results of this analysis, five hydrogen-blended natural gas leakage scenarios were selected. The national vision for a carbon-neutral society by 2050 is a very important strategic objective and promotes environmentally sustainable economic development in the age of the climate crisis. Accordingly, zero-carbon and low-carbon policies are being promoted in various fields, including energy production, consumption, and industrial processes. Hydrogen-blended natural gas is eco-friendly and is considered an important step towards carbon neutrality, with various countries including the United States and several European countries conducting empirical research to further investigate its potential. In Korea, a national research project commenced in April 2023 to verify and demonstrate the life cycle safety of blending hydrogen into the natural gas network. The results of this study will provide important data for the analysis of the damage impacts caused by the leakage of hydrogen-blended natural gas, such as the diffusion of gas clouds, fires, and gas explosions.

Diffusion Range and Pool Formation in the Leakage of Liquid Hydrogen Storage Tank Using CFD Tools

  • Kim, Soohyeon;Lee, Minkyung;Kim, Junghwan;Lee, Jaehun
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.653-660
    • /
    • 2022
  • In liquid hydrogen storage tanks, tank damage or leakage in the surrounding pipes possess a major risk. Since these tanks store huge amounts of the fluid among all the liquid hydrogen process facilities, there is a high risk of leakage-related accidents. Therefore, in this study, we conducted a risk assessment of liquid hydrogen leakage for a grid-type liquid hydrogen storage tank (lattice-type pressure vessel (LPV): 18 m3) that overcame the low space efficiency of the existing pressure vessel shape. Through a commercially developed three-dimensional computational fluid dynamics program, the geometry of the site, where the liquid hydrogen storage tank will be installed, was obtained and simulations of the leakage scenarios for each situation were performed. From the computational flow analysis results, the pool formation behavior in the event of liquid hydrogen leakage was identified, and the resulting damage range was predicted.

Study on the Consequence Analysis about Leakage Scenarios for Hydrogen Gas (수소가스 누출 시나리오에 따른 피해예측에 관한 연구)

  • Kim, Tae Hun;Oh, Young Dal;Lee, Man Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.159-165
    • /
    • 2014
  • For the hydrogen economy system being tried starting with the 21st century, the fields that was not dealt with so far, such as the safety measure for large leakage accidents, the safety problem at infrastructures like a hydrogen station, the safety problem in terms of automobiles depending on introduction of hydrogen cars, the safety problem in a supply for homes like fuel cells, etc., are being deeply reviewed. In order to establish a safety control system, an essential prerequisite in using and commercializing hydrogen gas as an efficient energy source, it is necessary to conduct an analysis, such as analysis of hydrogen accident examples, clarification of physical mechanisms, qualitative and quantitative evaluation of safety, development of accident interception technologies, etc. This study prepared scenarios of hydrogen gas leakage that can happen at hydrogen stations, and predicted damage when hydrogen leaks by using PHAST for this.

DetGas: A Carbon Monoxide Gas Leakage Detector Mobile Application

  • Kamaruddin, Farhan Fikri Mohd;Hadiana, Ana;Lokman, Anitawati Mohd
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.11
    • /
    • pp.59-66
    • /
    • 2021
  • Many incidents of Carbon Monoxide (CO) poisoning have occurred because of people being unaware of its presence. There are currently available systems on the market, but they are limited to measuring CO in a certain area and lack vital functions. Additionally, little to no evidence-based information on their quality was available. Thus, a mobile application for detecting CO gas leakage in a vehicle and critical features to assist victims was developed. A usability and functionality test were conducted to determine the product's quality utilizing nine usability and six functionality task scenarios (n=5). Then, a System Usability Scale test was performed to obtain system satisfaction, usability, and learnability (n=50). The usability and functionality test shows that all the tasks given for both tests were 100% successful. The overall score obtained for SUS was 71.4, which indicates good acceptance and usability. Around 20% of respondents claimed that they would need the support of a technical person to be able to use the application and that they needed to learn a lot of things before they could use the application, which indicates the overall high learnability of the application. The result provides empirical evidence that the CO gas leakage detection mobile application is successful and receives good usability, functionality, acceptability, learnability, and satisfaction assessments. DetGas could benefit automobile owners and other stakeholders by mitigating the risk and harm associated with gas leaking that exceeds the safe limit.

Analysis of Risk Assessment Factors for Gas leakage and Dispersion in Underground Power Plant (지하복합발전플랜트 내의 가스 누출 및 확산에 의한 위험성 평가 인자 분석)

  • Choi, Jinwook;Li, Longnan;Park, Jaeyong;Sung, Kunhyuk;Lee, Seonghyuk;Kim, Daejoong
    • Journal of ILASS-Korea
    • /
    • v.20 no.2
    • /
    • pp.101-106
    • /
    • 2015
  • Gas leakage and dispersion in the underground LNG power plant can lead to serious fire and explosion accident. In this study, computational fluid dynamics simulation was applied to model the dynamic process of gas leakage and dispersion phenomena in a closed space. To analyze the risk assessment factor, such as the flammable volume ratio, transient simulations were carried out for different scenarios. The simulation results visualized the gas distribution with time in the closed space. The flammable volume ratio was introduced for quantitative analysis the fire/explosion probability.

Development of Accident Scenarios for Hydrogen Refueling Station and Fuel Cell Vehicle (수소충전소 및 수소자동차의 사고 시나리오 개발)

  • Byoungjik Park;Yangkyun Kim;Ohk Kun Lim
    • Journal of Auto-vehicle Safety Association
    • /
    • v.15 no.1
    • /
    • pp.27-34
    • /
    • 2023
  • The registration rate of eco-friendly vehicles, such as hydrogen vehicles, is increasing rapidly, however, few first responders have experienced related accidents. Accident scenarios at hydrogen refueling stations and hydrogen vehicles on a road were investigated, and the relative importance of each scenario was analyzed using AHP analysis. Leakage, jet flame, and explosion that occurred inside and outside the hydrogen refueling station were reviewed, and the hydrogen gas explosion in the compartment showed the highest importance value. In case of the hydrogen vehicle, traffic accident statistics and actual accidents were used. It was analyzed that the hydrogen vessel explosion on the road due to the failure of TPRD and the leakage in the underground parking area were difficult to respond. The developed accident scenarios are expected to be used for first responder training.

Validity of solar energy generation at the underused Space of LPG filling station (LPG충전소 유휴공간의 태양광발전설비 설치 유효성)

  • Lee, Minkyung;Kim, Jeonghwan;Lee, Jinhan;Joe, Youngdo;Lee, Yeonjae
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.25-32
    • /
    • 2016
  • The purpose of this study is safety evaluation of solar energy generation which is installed on the canopy at the LPG filling station. in case of a gas station, the solar energy generation was become legalization through a related law reform in 2008. Also, in case of a LPG filling station, the solar energy generation was become legalization through a related law reform in 2015. So, the related law that KGS CODE and Safety control of dangerous substances law and the case of installed solar energy generation in gas, LPG filling station was investigated. two scenarios are supposed for the CFD. Release of safety valve pipeline and ruptured dispenser leakage are the scenarios. The FLACS which developed GexCon in Norway was used for simulation. LPG dispersion to the upper side of canopy was very small with safety distance.

LPG Cylinder Leak Experiment from Multiple Leak Scenarios (누출종류에 따른 LP가스용기 누출량 실증 실험)

  • Lee, Minkyung;Lee, Kang-Ok;Kim, Young Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.61-66
    • /
    • 2019
  • Unlike NG supplied through pipes, LPG is mainly used for independent storage of cylinders or small storage tanks. As LPG is widely used in islands and underdeveloped areas, accidents due to neglect of safety management are high. Houses and businesses that have LPG accidents are likely to be damaged due to relatively high population density. Therefore, the necessity of strengthening the safety management of LPG is constantly raised. Accordingly, in 1996, Korea Gas Safety Corporation conducted an LPG leak test. In this study, based on the 96-year experiment, the gas leakage measurement of LPG vessels was conducted by adding several conditions such as outside temperature and pipe condition. Through this, the trend of leakage for various scenarios of LPG leakage was examined. In the case of a gas leak, when the article which may affect the pressure such as a regulator is not connected, the leakage amount is greatly changed by the outside air temperature, and when the regulator is fastened, the influence of the outlet pressure is large. It is expected that the experiment can be used as basic data for determining gas accidents and leakages that may occur later.

Analysis of Safety by Expansion of Hydrogen Charging Station Facilities (수소충전소 설비 증설에 따른 안전성 해석)

  • Park, Woo-Il;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.83-90
    • /
    • 2020
  • This study conducted a risk assessment using the HyKoRAM program created by international joint research. Risk assessment was conducted based on accident scenarios and worst-case scenarios that could occur in the facility, reflecting design specifications of major facilities and components such as compressors, storage tanks, and hydrogen pipes in the hydrogen charging station, and environmental conditions around the demonstration complex. By identifying potential risks of hydrogen charging stations, we are going to derive the worst leakage, fire, explosion, and accident scenarios that can occur in hydrogen storage tanks, treatment facilities, storage facilities, and analyze the possibility of accidents and the effects of damage on human bodies and surrounding facilities to review safety.

Smart Home Safety Platform Program for City Gas Leakage (도시가스 누출에 따른 스마트 홈 안전 플랫폼 프로그램 구축)

  • Ji, HyunMin;Lee, Ugwiyeon;Oh, Jeongseok
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.97-102
    • /
    • 2019
  • In this study, city gas is the most commonly used in homes, and gas accidents are increasing as demand increases. Among them, accidents due to user carelessness are the most and we try to provide information by establishing scenarios to effectively prevent this. The gas leak in the home is an enclosed space, and the appropriate Gaussian model is applied. As smart home control technology is developed by the 4th industrial revolution, it will make a foundation to provide information through program to predict and prevent gas leakage accidents and apply it to smart home safety platform.