• Title/Summary/Keyword: gas laser

Search Result 717, Processing Time 0.025 seconds

Laser-Induced Plasma Spectroscopy Measurement on Surface Roughness in Surface Treatment of Titanium Alloys (티타늄 합금의 표면 처리에 있어 표면 거칠기에 대한 레이저 유도 플라즈마 분광분석법 측정 적용 연구)

  • Kim, Ji-Hun;Kim, Joohan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.9-17
    • /
    • 2020
  • In this study, the surface changes of titanium alloy using laser surface treatment and the surface analysis using laser-induced plasma spectroscopy were carried out. The laser surface treatment induced changes in surface roughness and the diffusion of atmospheric elements. Excessive melting or less melting caused roughness changes, but when moderate levels of energy were applied, a smoother surface could be obtained than the initial surface. In the process, the diffusion of atmospheric elements took place. To analyze the diffusion of atmospheric elements with respect to surface morphology, the surfaces were re-shaped with grinding. In this experimental conditions, the effect of plasma formation by surface roughness was identified. Compensated plasma signals for the material properties were obtained and analysed by removing the background plasma signal.

Characteristics of Plasma Emission Signals in Fiber Laser Welding for API Steel (I) -Variation of Signals by Measuring Conditions- (API강재의 화이버레이저 용접시 유기하는 플라즈마의 방사특성 (I) -측정조건에 따른 광신호의 변화-)

  • Kim, Jong-Do;Lee, Chang-Je;Lee, Mok-Young
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.94-94
    • /
    • 2010
  • Fiber laser is a heat source which is introduced recently, and so has a little researched data compare with conventional laser processing. Moreover basic data for welding monitoring are also insufficient. Therefore, in this study, the change of signal with measuring position and angle of plasma emission signals were analysed as a basic experiment for real time monitoring in fiber laser welding. As a result, the signals measured from the side, front and rear had the biggest intensity at $60^{\circ}$, and frequency peak to reflect the behavior of keyhole and swing of plasma by shield gas was detected at $45{\sim}60^{\circ}$. However, both intensity of signal and the result of FFT for monitoring were satisfied at the angle of $45^{\circ}$ from the side.

  • PDF

Analysis of Xe Plasma by LAS (레이저 흡수법을 이용한 제논 플라즈마 분석)

  • Yang, Jong-Kyung;Her, In-Sung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.220-222
    • /
    • 2005
  • We can classify two cases in a way to observe an atom of gas state or a molecule using the laser. First case is way to use dispersion phenomenon like Rayleigh scattering, Thomson scattering, Mie scattering, Raman Scattering. And Second case is a way to use change phenomenon like a LAS (Laser Absorption Spectroscopy), LIF (Laser Induced Fluorescent). In this paper, we have measured the meta-stable density and the distribution by using a LAS method in Xe discharge lamp. The laser absorption spectroscopy (LAS) is useful to investigate the behavior of such species. The xenon atoms in the $1S_4$ and $1S_5$ generate excited $Xe^*$(147nm) and $Xe_{2}^*$(173nm) dimers in Xe plasma. It is found that the intensity of VUV 147nm emission is proportional to that of the IR 828nm emission, and the VUV 173nm emission is roughly proportional to that of the IR 823nm emission. The laser is used CW laser that consist of AlGaAs semiconductor and energy level is used 823.16nm wavelength. We measured signal of monochrometer from the lamp center while will change a discharge electric current by 6mA in 3mA and calculated meta-stable state density of a xenon atom through a measured value.

  • PDF

Spectral Line Identification and Emission Characteristics of the Laser-Induced Plasma in Pulsed Nd:YAG Laser Welding (펄스 YAG 레이저 용접시 유기하는 플라즈마의 스펙트럼선 동정과 발광특성)

  • 김종도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.360-368
    • /
    • 1999
  • The paper describes spectroscopic characteristics of plasma induced in the pulsed YAG laser welding of alloys containing a large amount of volatile elements. The authors have conducted the spectroscopic analyses of laser induced Al-Mg alloys plasma in the air and argon atmosphere. In the air environment the identified spectra were atomic lines of Al, Mg, Cr, Mn, Cu, Fe and Zn and singly ionized Mg lines as well as the intense molecular spectra of ALO and MgO formed by chemi-cal reactions of evaporated Al and Mg atoms from the pool surface with oxygen in the air. In argon atmosphere MgO and AlO spectra vanished but AlH spectrum was detected. the hydrogen source was presumable hydrogen dissolved in the base metals water absorbed on the surface oxide layer or $H_2$ and $H_2O$ in the shielding gas. The resonant lines of Al and Mg were strongly self-absorbed in particular self-absorption of the Mg line was predominant. These results show that the laser induced plasma was made of metallic vapor with relatively low temperature and high density.

  • PDF

A Study on Laser Assisted Machining for Silicon Nitride Ceramics (I) - Preheating Characteristics and Oxidation Behaviors of Silicon Nitride Ceramics with Machining Parameters - (질화규소 세라믹의 레이저 예열선삭에 관한 연구 (I) - 공정변수에 따른 질화규소의 예열특성 및 산화거동 -)

  • Kim, Jong-Do;Lee, Su-Jin;Shu, Jeong;Lee, Jae-Hoon
    • Journal of Welding and Joining
    • /
    • v.28 no.4
    • /
    • pp.61-66
    • /
    • 2010
  • Silicon nitride is widely used as an engineering ceramics because it has high strength, abrasion resistance and corrosion resistance even at high temperature. However, machining of silicon nitride is difficult due to its high hardness and brittleness. Laser assisted machining(LAM) allows effective cutting using CBN tool by locally heating the cutting part to the softening temperature of YSiAlON using the laser beam. The effect of preheating depending on process parameters were studied to find out the oxidation mechanism. If silicon nitride is sufficiently preheated, the surface is oxidized and $N_2$ gas is formed and escapes from the material, thereby making the cutting process more advantageous. During laser preheating process before machining, high temperature results in strong oxidation which makes the bloating, silicate layers and micro cracks. Using the results of these experiments, preheating characteristics and oxidation behavior were found out.

A Study on the Laser Welding of Cladding Tube with Temp. Sensor for Fuel Irradiation Test (핵연료 조사시험용 온도센서 피복재의 레이저용접 연구)

  • Kim, Su-Seong;Lee, Cheol-Yong;Kim, Ung-Gi;Lee, Jeong-Won;Go, Jin-Hyeon;Lee, Yeong-Ho
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.106-108
    • /
    • 2005
  • The instrumented fuel irradiation test at a research reactor is needed to evaluate the performance of the developed nuclear fuel. The fuel elements can be designed to measure the center line temperature of fuel pellets during the irradiation test by using temperature sensor. The thermal sensor was composed of thermocouple and sensor sheath. Micro-laser welding technology was adopted to seal between seal tube and sensor sheath with thickness of 0.15 mm. The soundness of welding area has to be confirmed to prevent fission gas of the fuel from leaking out of the element during the fuel irradiation test. In this study, fundamental data for micro-laser welding technology was proposed to seal temperature sensor sheath of the instrumented fuel element. And, micro-laser welding for dissimilar metals between sensor sheath and seal tube was characterized by investigating welding conditions. Moreover, the micro-laser welding technology is closely related to advanced industry. It is expected that the laser material processing technology will be adopted to various a pplications in the industry.

  • PDF

A Study on the Pulsed $CO_2$ Laser by the Switching Control of Leakage Transformer Primary (누설변압기 1차측의 스위칭 제어에 의한 펄스형 $CO_2$레이저에 관한 연구)

  • Chung, Hyeon-Ju;Lee, Dong-Hoon;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.9
    • /
    • pp.541-545
    • /
    • 2000
  • We propose a pulsed $CO_2$laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantages of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5 Hz to 60 to Hz control laser output. In this laser a low voltage open loop control for high voltage pulse discharge circuit is employed to aviod the Hv sampling or switching and high voltage leakage transformer is used to convert low voltage pulse rectified from AC to high voltage one. A ZCS(Zero Crossing Switch) circuit and a PIC(programble one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leadkage inductance. The maximum laser output was about 23 W at pulse repetition rate of 60Hz total gas mixture of $CO_2$ : $N_2$ : He=1: 9: 15 and total pressure of 18 Torr

  • PDF

Operational Characteristics of a Nitrogen Laser with Sliding Discharge and Longitudinal Excitation (종방향 여기 방식과 표면방전에 의한 질소레이저의 동작 특성)

  • Lee, Bong-Yeon
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.450-455
    • /
    • 2005
  • We have studied on operational characteristics of the nitrogen laser with sliding discharge and longitudinal excitation. We could observe radiation of nitrogen laser excited by a sliding discharge along the surface of a dielectric. The shape of the beam was a ring type which had 2 mm or 4mm in diameter depending on the sliding discharge tube shape. In this experiment, We show the possibilities to make other shapes of laser beam, for example, rectangle, ellipse, and to excite another gas laser system like an excimer laser.

Effect of Laser Heat-treatment on WC-CoFe Coated Surface by HVOF (초고속화염용사 WC-CoFe 코팅층의 레이저 표면 열처리 효과)

  • Joo, Yunkon;Yoon, Jaehong;Lee, Jehyun
    • Korean Journal of Materials Research
    • /
    • v.29 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • The microstructure, hardness, and wear behaviors of a High Velocity Oxygen Fuel(HVOF) sprayed WC-CoFe coating are comparatively investigated before and after laser heat treatments of the coating surface. During the spraying, the binder metal is melted and a small portion of WC is decomposed to $W_2C$. A porous coating is formed by evolution of carbon oxide gases formed by the reaction of the free carbon and the sprayed oxygen gas. The laser heat treatment eliminates the porosity and provides a more densified microstructure. After laser heat treatment, the porosity in the coating layer decreases from 1.7 % to 1.2 and the coating thickness decreases from $150{\mu}m$ to $100{\mu}m$. The surface hardness increases from 1440 Hv to 1117 Hv. In the wear test, the friction coefficient of coating decreases from 0.45 to 0.32 and the wear resistance is improved by the laser heat treatment. The improvement is likely due to the formation of oxide tribofilms.

Respiratory Protection for LASER Users

  • Lee, Sang Joon;Chung, Phil-Sang;Chung, Sang Yong;Woo, Seung Hoon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • The plume produced by vaporizing tissue with a laser contains a variety of contaminants called laser-generated air pollutants (LGACs). LGACs consist of a mixture of toxic gas components, biomicroparticles, dead and living cells, and viruses. Toxic odors and thick smoke from surgical incisions and the coagulation of tissues can irritate eyes and airways, as well as cause bronchial and pulmonary congestion. Because of the potential risk of the smoke, it is advisable to appropriately remove it from the surgical site. We recommend using a smoke evacuator to remove the smoke. Suction nozzles should be placed as close as possible to the surgical site in a range of 2 cm or less. In-line filters should be used between the inlet and outlet of the surgical site. All air filtration devices should be capable of removing particles below 0.1 microns in size. The filter pack should be handled according to infection control procedures in the operating room. The laser mask can be an auxiliary protective device if it is properly worn. Some smoke inhaled under the nose wrap or over the side of the mask will not be filtered. As in electrosurgical operations, a suitable mask should be worn while smoke is present.