• 제목/요약/키워드: gas flowmeter

검색결과 39건 처리시간 0.026초

전달 시간차 방식 다회선 초음파 가스 유량계 개발 (Study on the Development of Multi-Path Ultrasonic Gas Flowmeter)

  • 황원호;박상국;이치환;장경영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1046-1050
    • /
    • 2003
  • In this paper, we describe study on the development or multi-path ultrasonic gas flowmeter using a transit time method. This system includes 5 pairs of ultrasonic transducers. ultrasonic signal processing unit using switch matrix method, computation algorithm of gas flow rate, spool piece type multi-path pipe unit. We have developed enhanced type of main ultrasonic signal processing unit using switch matrix method fer multi-path ultrasonic gas flowmeter. Also, we have developed the new transmitting & receiving method of ultrasonic waves and the new signal processing algorithm for the computation of ultrasonic transit time from received ultrasonic waves. In this study, we have designed more compact signal processing unit compared with the conventional hardware system of multi-path ultrasonic gas flowmeter. We have confirmed its reliability for multi-path ultrasonic gas flowmeter through the laboratory test using calibration system. In the future. we will perform the field test for the developed system in the POSCO gas line.

  • PDF

초음파 가스 유량계 개발 연구 (Study on the development of ultrasonic gas flowmeter)

  • 황원호;박상국;양규홍;장경영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.76-81
    • /
    • 2001
  • Ultrasonic flowmeters have more advantages than the conventional method using pressure-difference. In these reasons, many advanced nations are already selling the commercial model. In RIST, we have been developed ultrasonic gas flow meter for the localization since a project was been contracted with POSCO in 1997. This paper describes a new ultrasonic gas flowmeter. This ultrasonic gas flowmeter is developed for accurate measurement of gases in a harsh environmental conditions. It is especially suited for measuring LDG, COG, BFG gases produced in iron & steel making process. In this study, we had developed the commercial model about the first tested model and applied a completed system to the POSCO gas line. Its performance has already well been proven by extensive field tests for several months in POSCO, iron & steel making company.

  • PDF

기체유량계용 초음파 센서의 설계 및 공진 특성 (Design and Resonant Characteristics of the Ultrasonic Sensor for Gas Flowmeter)

  • 홍재일;이상철
    • 전기학회논문지P
    • /
    • 제51권4호
    • /
    • pp.193-197
    • /
    • 2002
  • In this paper, the ultrasonic sensor for gas flowmeter was simulated, fabricated and measured according to the assembly step and the piezoelectric vibrator layers. The simulated resonant frequency and the measured resonant frequency were similar except two layer sensor. The simulated resonant frequency of three layer sensor was 48 kHz and the measured resonant frequency of three layer sensor was 45.2 kHz. From the results, the ultrasonic sensor for gas flowmeter could be designed and expected without fabrication.

초음파 가스 유량계 개발 연구 (Study on the Development of Ultrasonic Gas Flowmeter)

  • 황원호;박상국;장경영
    • 대한기계학회논문집A
    • /
    • 제27권1호
    • /
    • pp.138-143
    • /
    • 2003
  • Ultrasonic flowmeters have more advantages than the conventional method using pressure-difference. In these reasons, many advanced nations are already selling the commercial model. In RIST, we have been developed ultrasonic gas flow meter for the localization since a project was been contracted with POSCO in 1997. This paper describes a new ultrasonic gas flowmeter. This ultrasonic gas flowmeter is developed for accurate measurement of gases in a harsh environmental conditions. It is especially suited for measuring LDG. COG, BFG gases produced in iron & steel making process. In this study, we had developed the commercial model about the first tested model and applied a completed system to the POSCO gas line. Its performance has been proven by extensive field tests for several months in POSCO, iron & steel making company.

초음파 가스 유량계 개발과 활용 (Development and Application of an Ultrasonic Gas Flowmeter)

  • 황원호;박상국;정희돈;장경영
    • 비파괴검사학회지
    • /
    • 제22권3호
    • /
    • pp.246-253
    • /
    • 2002
  • 제철공정에서 발생하는 열악한 환경의 가스를 계측하기 위해서 개발한 초음파 가스 유량계와 현장 적용 결과에 대해서 기술한다. 개발된 초음파 유량계는 제철공정에 생산되는 부생가스인 LDG, COG, BFG 등의 활용에 적합하도록 개발했다. 그리고 본 초음파 유량계는 초음파 전달시간차 방식을 채택하고 있다. 전달 시간차 방식의 초음파 유량계를 구현하기 위한 초음파 신호의 송수신 알고리즘 및 초음파 신호처리 알고리즘을 개발했다. 유량계의 성능을 검증하기 위해서 대용량 유량 검 교정 장치를 자체 제작하여 유량계 검 교정 실험을 행했고 Venturi Type의 기준유량계와 비교실험을 통해서 측정오차를 평가했다. 실제 제철공정에 1년 이상의 적용 테스터를 통해 초음파 유량계의 신뢰성을 확인했으며 현재 상업화 모델이 개발되어 현장에서 활용 중에 있다.

기체유량계용 초음파 센서 개발 (Development of the Ultrasonic Sensor for Gas Flowmeter)

  • 홍재일;이상철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.131-134
    • /
    • 2002
  • In this paper, the ultrasonic sensor for gas flowmeter was simulated, fabricated and measured with assembly step and piezoelectric vibrator layers. The simulated resonant frequency and the measured resonant frequency were similar except sensor 2. The simulated resonant frequency of sensor 3 was 48 kHz and the measured resonant frequency of sensor 3 was 45.2 kHz. From the results, the ultrasonic sensor for flowmeter could be designed and expected without fabrication.

  • PDF

슬러그 2상유동에서 전류형식 전자기유량계 수치적 신호예측 및 보정 (Numerical Signal Prediction and Calibration Using the Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Slug Flow)

  • 안예찬;오병도;김종록;김무환;강덕홍
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.671-686
    • /
    • 2005
  • The transient nature and complex geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et al.). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. The velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method, and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for simulating slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are proposed for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

슬러그류 액상속도 측정용 전류형식 전자기유량계 개발 (Development of a Current-Type Electromagnetic Flowmeter to Obtain the Liquid Mean Velocity in Two-Phase Slug Flow)

  • 강덕홍;안예찬;김종록;오병도;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1951-1956
    • /
    • 2004
  • The transient nature and complex flow geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et $al.^{(1)}$). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. To do this, the velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for the simulated slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are required for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

  • PDF

천연가스 유량계 교정 시스템의 설계${\cdot}$구축 및 운영 (Design, Construction & Operation of Natural Gas Flowmeter Calibration System)

  • 이승준;이강진;정종태;하영철;안승희;이철구;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.389-393
    • /
    • 2001
  • Korea Gas Corporation(KOGAS) have constructed a gas flowmeters' calibration facilities at Jungdong Bucheon. The facilities consisting of 6 reference turbine meters can perform calibrations of large capacity natural gas flowmeters up to $9,600 m^3/h$ at 95 kPa. This large capacity and high pressure natural gas facilities is traceable to the national standard of gas flow rate (KRISS). In this article the motive of construction and description of design are summarized.

  • PDF