• Title/Summary/Keyword: gas flow

Search Result 5,567, Processing Time 0.032 seconds

Evaluation of Critical Flow Function by Using Helmholtz Free Energy for Natural Gas Flow Measurement (천연가스 유량 측정에서 헬름홀츠 자유에너지를 이용한 임계유동함수 계산)

  • Ha, Young-Cheol;Her, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1167-1173
    • /
    • 2013
  • This study aimed to calculate the CFFs (critical flow functions) of a sonic nozzle bank with a 12-nozzle package within 1 s. Toward this end, the Helmholtz free energy of natural gas was formulated by using the AGA8-dc equation of state in a form without integral terms, and thereafter, thermodynamic properties such as the enthalpy, entropy, speed of sound, and heat capacity, which are used in CFF calculation, were derived in analytical form. As a result, the calculation time of CFFs was improved from 6.7 s in a previous study to 0.6 s per 12-nozzle package and kept almost constant regardless of the number of components in natural gas. Furthermore, it was confirmed that the calculated CFF values were in agreement with the results of a CFF international comparison test carried out under ISO management in 1998-1999.

Numerical simulation of thermo-fluid flow in the blast furnace (고로내 열유동 현상의 수치해석 사례(I))

  • Jin, Hong-jong;Choi, Sang-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2038-2043
    • /
    • 2007
  • Analysis of the internal state of the blast furnace is needed to predict and control the operating condition. Especially, it is important to develop modeling of blast furnace for predicting cohesive zone because shape of cohesive zone influences on overall operating condition of blast furnace such as gas flow, temperature distribution and chemical reactions. Because many previous blast furnace models assumed cohesive zone to be fixed, they can't evaluate change of cohesive zone shape by operation condition such as PCR, blast condition and production rate. In this study, an axi-symmetric 2-dimensional steady state model is proposed to simulate blast furnace process using the general purpose-simulation code. And Porous media is assumed for the gas flow and the potential flow for the solid flow. Velocity, pressure and temperature distribution for gas and solid are displayed as the simulation results. The cohesive zones are figured in 3 different operating conditions.

  • PDF

CFD Simulation to Study Flow Characteristics in Cylindrical Gas-Liquid Cyclone Separator (실린더형 기-액 원심분리기 내의 유동특성 연구를 위한 CFD 시뮬레이션)

  • Park, Gyung-Do;Park, Jong-Chun;Kim, Kyung-Mi
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.280-287
    • /
    • 2014
  • In this paper, the numerical simulation of the gas-liquid flow in a cylinder cyclone separator is performed to investigate the flow characteristics using a commercial software, FLUENT, which solves the Reynolds-averaged Navier-Stokes(RaNS) equations. First, a single-phase flow with water in a gas-liquid cylinder cyclone(GLCC) separator is simulated and compared with the experiments(Farchi, 1990) and numerical simulations(Erdal, 1997). Then, the characteristics of the multi-phase flow for water-air, mud-only, and mud-air cases are discussed in the view point of the feasibilities for a mud handling system.

COMPUTATIONAL ANALYSIS FOR IMPROVING UNIFORMITY OF $SNO_2$ THIN FILM DEPOSITION IN AN APCVD SYSTEM ($SnO_2$ 박막증착을 위한 APCVD Reactor 내 유량 균일도 향상에 대한 수치 해석적 연구)

  • Park, J.W.;Yoon, I.R.;Chung, H.S.;Shin, S.W.;Park, S.H.;Kim, H.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.567-570
    • /
    • 2010
  • With continuously increasing flat panel display size, uniformity of thin film deposition has been drawing more attentions and associated fabrication methodologies are being actively investigated. Since the convective flow field of mixture gas plays a significant role for deposition characteristics of thin film in an APCVD system, it is greatly important to maintain uniform distribution and consistent concentration of mixture gas species. In this paper, computational study has been performed for the improvement of flow uniformity of mixture gas in an APCVD reactor during thin film deposition process. A diffuser slit has bee designed to spread the locally concentrated gas flow exiting from the flow distributor. A uniform flow distributor has been developed which has less dependency on operating conditions for global flow uniformity

  • PDF

Performance of Flow Rate Control of a Cavitating Venturi (캐비테이션 벤튜리의 유량제어 성능)

  • Cho Won Kook;Moon Yoon Wan;Kim Young-Mog
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.146-151
    • /
    • 2002
  • Characteristics of flow rate control has been studied for a cavitating venturi adopted in a liquid rocket propellant feed system. Numerical simulation has been peformed to give about $10\%$ discrepancy of mass flow rate to the experimental data for cavitating flow regime. Mass flow rate is confirmed to be saturated for pressure difference higher than $3\times10^5$pa when the upstream pressure is fixed to $22.8\times10^5$pa and the downstream pressure is varied. The evaporation amount depends substantially to non-condensable gas concentration. However the mass flow rate characteristic is relatively insensitive to the mass fraction of non-condensable gas. So it is reduced by only $2\%$ when the non- condensable gas concentration is increased from 1.5PPM to 150PPM. From the previous comparison the expansions of the non-condensable gas and the evaporation of liquid are verified to have same effect to pressure recovery.

  • PDF

Gas-Flow Sensor using Optical Fiber Bragg Grating(FBG)

  • Shim, Joon-Hwan;Cho, Seok-Je;Yu, Yung-Ho;Sohn, Kyung-Rak
    • Journal of Navigation and Port Research
    • /
    • v.32 no.9
    • /
    • pp.717-722
    • /
    • 2008
  • We have proposed and demonstrated an gas-flow sensor using optical fiber bragg grating(FEG). The flow sensor has no electronics and no mechanical parts in its sensing part and the structure is th11s simple and immune to electromagnetic interference(EMI). The FEG sensor was consisted qf the sensing element and a coil heater. The metal coil was used to supply the current to the FEG. While some currents supply to the coil, the refractive index of the FEG under the coil is changed and thus the wavelength shift of fiber optic sensor was induced In this work, the wavelength shift according to flow-rate was experimentally studied and was used to evaluate the gas flow-rate in a gas tube. As a result, it was possible to measure the flow-rate in a linear range from 5 to $20{\ell}/min$ with a resolution of approximately $1{\ell}/min$ at the applied currents of 100 mA and 120 mA. The measured sensitivities were $15.3\;pm/\ell/min$ for 100 mA and $20.2\;pm/\ell/min$ for 120 mA.

An Investigation of the Major Factors Relating to the Flow Fluctuation at a Natural Gas Metering Facility (천연가스 계량설비에서 발생하는 유량 헌팅 현상 원인 분석)

  • An, Seung-Hee;Her, Jae-Young;Jeong, Jong-Tae;Sin, Chang-Hun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.158-165
    • /
    • 2005
  • KOGAS(Korea Gas Corporation) has about a hundred of local stations to supply natural gas to the city gas companies and the power stations. As some severe flow fluctuation phenomena are observed in several governor stations, the investigation about the reasons and factors which are relating to flow fluctuation has been started. Some field surveys hav been carried out and experimental studies have been performed to find the fluctuation mechanism. As a result, it is found that the flow fluctuation is related with the length of straight pipe in front of the meter, the size of the header pipe and the variation of demand at the city gas company and the power station. Furthermore. it is also proved that both the length of the transmitter cable and the status of the coating of signal transmission cable do not affect flow fluctuation, but the measurement range of the differential pressure transmitter influences flow fluctuation. On the other hand, as the averaging the flow fluctuation is converged to less than 0.1 % in almost all of the cases, it is concluded that the quantity of flow fluctuation do not relates to metering accuracy directly.

  • PDF

Study on the Characteristics of Bubble and Liquid Slugs for Gas-Liquid Taylor Flow in a Rectangular Micro-channel (사각 마이크로 채널 내 Taylor Flow의 기포 및 액체 슬러그 유동 특성에 대한 연구)

  • Lee, Jun Kyoung;Lee, Kwan Geun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.520-526
    • /
    • 2015
  • The characteristics of gas-liquid Taylor (Slug) flow in a square micro-channel of $600{\sim}600{{\mu}m}$ were investigated experimentally in this paper. The test fluids were nitrogen and water. The liquid and gas superficial velocities were 0.01~3 m/s and 0.1~3 m/s, respectively. Bubble and liquid slug length, bubble velocity, and frequency were measured by analyzing optical images using a high speed camera. Bubble length decreased with higher liquid flow rate, which increased dramatically with higher gas flow rate. However, slug length did not vary with changes in inlet liquid conditions. Additionally, bubble velocities and frequencies increased with higher liquid and gas flow rates. It was found that measured bubble lengths were in good agreement with the empirical models in the existing literature, but slug lengths were not.

Numerical Analysis for Evaluation of Ejection Capacity Relationship of Safety Valves in Pressure Regulating Station(I) - Flow Analysis and Mass Flow Rate Verification of Pressure Regulator - (정압기지내의 안전밸브 분출용량 관계식 검증을 위한 유동해석(I) - 정압기 유동 해석 및 질량 유량 검증 -)

  • Gwon, Hyuk-Rok;Roh, Kyung-Chul;Kim, Young-Seop;Lee, Seong-Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.99-104
    • /
    • 2008
  • Gas pressure regulators in pressure regulating station reduce high-pressure gas in a process line to a lower. Gas pressure regulators are not flow control devices, they are used to control delivery pressure only. For the safety of pressure regulating station, it is essential to study flow regime and characteristics of a safety valves that is connected to a pressure regulator. For this, it is necessary to understand flow characteristics and the flow rate of upstream component part such as gas pressure regulators in regulating station. In the present study, numerical analysis of flow characteristics and the mass flow rate of a pressure regulator is conducted under the several inlet, outlet conditions and open rates. Then, the numerical result of the mass flow rate is verified with experimental equation from manufacture of pressure regulator. Consequently, the numerical result is comparatively good agreement with values from experimental equation.

  • PDF

Uncertainty Assessment Using Monte Carlo Simulation in Gas Flow Measurement (기체 유량 측정에서 몬테 카를로 모사를 이용한 측정불확도 평가)

  • Lee, Dae-Sung;Yang, In-Young;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1758-1765
    • /
    • 2003
  • Monte Carlo simulation(MC) method was used as an uncertainty assessment tool for gas flow measurement in this paper. Uncertainty sources for gas flow measurement were analyzed, and probability distribution characteristics of each source were discussed. Detailed MC methodology was described including the effect of the number of simulation. The uncertainty result was compared with that of the conventional sensitivity coefficient method, and it was revealed that the results were different from each other for this particular gas flow measurement case of which the modelling equation was nonlinear. The MC was comparatively simple, convenient and accurate as an uncertainty assessment method, especially in cases of complex, nonlinear measurement modelling equations. It was noted that the uncertainty assessment method should be selected carefully according to the mathematical characteristics of the measurement.