• Title/Summary/Keyword: gas exchange

Search Result 652, Processing Time 0.03 seconds

Autotrophic Growth of Dendranthema grandiflorum R. 'Bongwhang' Plantlets In Vitro as Affected by PPF, Air Exchange Rate and $\textrm{CO}_2$ Concentration (봉황국화의 자가영양배양시 광도, 환기횟수 및 $\textrm{CO}_2$농도가 기내생육에 미치는 영향)

  • 김영회;정병룡
    • Journal of Bio-Environment Control
    • /
    • v.8 no.1
    • /
    • pp.56-66
    • /
    • 1999
  • Growth of Dendranthema grandiflorum R. ‘Bongwhang’plantlets, as affected by three levels of photosynthetic photon flux (PPF), 70, 150 and 220 $\mu$mol. $m^{-2}$ . $s^{-1}$ , three levels of C $O_{2}$ concentration, 400-500 (ambient), 1000 and 2000 $\mu$mol.mo $l^{-1}$ , and two levels of number of air exchanges per hour (NAEH), 0.1 $h^{-1}$ and 2.8 $h^{-l}$, was studied. Explants were obtained from photomixotrophically-micropropagated plantlets. Four explants were planted in each 3.7$\times$10$^{-4}$ $m^{3}$ polycarbonate box containing MS medium supplemented with 1.25 meq. $L^{-1}$ $H_{2}$P $O_{4}$$^{[-10]}$ and no added sugar. Explants were cultured under cool-white fluorescent lamps (16 h. $d^{-1}$ ), at 25$\pm$1$^{\circ}C$ temperature, and 70-80% relative humidity. In treatments of 2.8 $h^{-1}$ NAEH, a 10 mm round hole made on the vessel cap was sealed with a microporous filter For higher C $O_{2}$ concentrations in the culture room, C $O_{2}$ gas was provided from a tank of liquefied C $O_{2}$. Fresh and dry weights, height, length of the longest roots, number of leaves, and leaf area significantly increased with increasing PPF and especially, with increasing C $O_{2}$ concentration. Growth was enhanced with increased number of air exchanges per hour (2.8 $h^{-1}$ ). Overall, treatment of 220$\mu$mol. $m^{-2}$ . $s^{-1}$ PPF combined with 2000$\mu$mol.mo $l^{-1}$ C $O_{2}$ and 2.8 $h^{-1}$ NAEH gave the most vigorous growth of Dendranthema grandiflorum R. ‘Bongwhang’ plantlets in vitro.o.

  • PDF

Development of 'Carbon Footprint' Concept and Its Utilization Prospects in the Agricultural and Forestry Sector ('탄소발자국' 개념의 발전 과정과 농림 부문에서의 활용 전망)

  • Choi, Sung-Won;Kim, Hakyoung;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.4
    • /
    • pp.358-383
    • /
    • 2015
  • The concept of 'carbon footprint' has been developed as a means of quantifying the specific emissions of the greenhouse gases (GHGs) that cause global warming. Although there are still neither clear definitions of the term nor rules for units or the scope of its estimation, it is broadly accepted that the carbon footprint is the total amount of GHGs, expressed as $CO_2$ equivalents, emitted into the atmosphere directly or indirectly at all processes of the production by an individual or organization. According to the ISO/TS 14067, the carbon footprint of a product is calculated by multiplying the units of activity of processes that emit GHGs by emission factor of the processes, and by summing them up. Based on this, 'carbon labelling' system has been implemented in various ways over the world to provide consumers the opportunities of comparison and choice, and to encourage voluntary activities of producers to reduce GHG emissions. In the agricultural sector, as a judgment basis to help purchaser with ethical consumption, 'low-carbon agricultural and livestock products certification' system is expected to have more utilization value. In this process, the 'cradle to gate' approach (which excludes stages for usage and disposal) is mainly used to set the boundaries of the life cycle assessment for agricultural products. The estimation of carbon footprint for the entire agricultural and forestry sector should take both removals and emissions into account in the "National Greenhouse Gas Inventory Report". The carbon accumulation in the biomass of perennial trees in cropland should be considered also to reduce the total GHG emissions. In order to accomplish this, tower-based flux measurements can be used, which provide a direct quantification of $CO_2$ exchange during the entire life cycle. Carbon footprint information can be combined with other indicators to develop more holistic assessment indicators for sustainable agricultural and forestry ecosystems.

Energy expenditure of physical activity in Korean adults and assessment of accelerometer accuracy by gender (성인의 13가지 신체활동의 에너지 소비량 및 가속도계 정확성의 남녀비교)

  • Choi, Yeon-jung;Ju, Mun-jeong;Park, Jung-hye;Park, Jong-hoon;Kim, Eun-kyung
    • Journal of Nutrition and Health
    • /
    • v.50 no.6
    • /
    • pp.552-564
    • /
    • 2017
  • Purpose: The purpose of this study was to measure energy expenditure (EE) the metabolic equivalents (METs) of 13 common physical activities by using a portable telemetry gas exchange system ($K4b^2$) and to assess the accuracy of the accelerometer (Actigraph $GT3X^+$) by gender in Korean adults. Methods: A total of 109 adults (54 males, 55 females) with normal BMI (body mass index) participated in this study. EE and METs of 13 selected activities were simultaneously measured by the $K4b^2$ portable indirect calorimeter and predicted by the $GT3X^+$ Actigraph accelerometer. The accuracy of the accelerometer was assessed by comparing the predicted with the measured EE and METs. Results: EE (kcal/kg/hr) and METs of treadmill walking (3.2 km/h, 4.8 km/h and 5.6 km/h) and running (6.4 km/h) were significantly higher in female than in male participants (p < 0.05). On the other hand, the accelerometer significantly underestimated the EE and METs for all activities except descending stairs, moderate walking, and fast walking in males as well as descending stairs in females. Low intensity activities had the highest rate of accurate classifications (88.3% in males and 91.3% females), whereas vigorous intensity activities had the lowest rate of accurate classifications (43.6% in males and 27.7% in females). Across all activities, the rate of accurate classification was significantly higher in males than in females (75.2% and 58.3% respectively, p < 0.01). Error between the accelerometer and $K4b^2$ was smaller in males than in females, and EE and METs were more accurately estimated during treadmill activities than other activities in both males and females. Conclusion: The accelerometer underestimated EE and METs across various activities in Korean adults. In addition, there appears to be a gender difference in the rate of accurate accelerometer classification of activities according to intensity. Our results indicate the need to develop new accelerometer equations for this population, and gender differences should be considered.

Experimental Fetal Cardiopulmonary Bypass in the Fetal Lamb Model (태아양 모델을 이용한 실험적 태아 심폐우회술)

  • 이정렬;임홍국;김원곤;김종성;최정연;김용진
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.495-503
    • /
    • 1999
  • Background: We tested the technical feasibility of fetal cardiac bypass and collected baseline data on the fetal hemodynamics and placental functions related to the cardiopulmonary bypass in the fetal lamb model. Material and Method: Eleven fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Eight served as a group in which placenta was excluded from the extracorporeal circulation by clamping the umbilical cord during the bypass(the oxygenator group) and in the remaining three, the placenta worked as the only source of oxygen supply(the placenta group). Observations were made every 10 minute during a 30-minute bypass and 30-minute post bypass period. No prostaglandin inhibitors were used both in ewes and in fetuses. Result: Weights of the fetuses ranged from 1.9 to 5.2 kg. In the oxygenator group, means of arterial pressure, PaO2, atrial pressure, heart rate, and bypass flow rate ranged 69.8 to 82.6 mmHg, 201.7 to 220.9 mmHg, 4.1 to 4.3 mmHg, 169 to 182/min, and 140.3 to 164.0 ml/kg/min, respectively during bypass, but rapid deterioration of the fetal cardiac functions and the placental gas exchange was observed after the cessation of bypass. In the placenta group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of PaCO2 increased from 61.9 to 129.6 mmHg during bypass. Flow rate was suboptimal(74.3 to 97.0 ml/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. Conclusion: In this study, the technical feasibility of fetal cardiopulmonary bypass was confirmed in the fetal lamb model. However, further studies with modifications of the bypass including an addition of prostaglandin inhibitor, an application of the total spinal anesthesia on the fetus, a creation of more concise bypass circuit, and a use of active pump are mandatory to improve the outcome.

  • PDF

Prediction of Intubation after Bronchoscopy with Non-invasive Positive Pressure Ventilation Support in Patients with Acute Hypoxemic Respiratory Failure (급성 저산소혈증 환자에서 비침습적 양압환기 적용 하 기관지경 검사 후 기관 삽관의 예측 인자)

  • Song, Jae-Uk;Kim, Su-A;Choi, E Ryoung;Kim, Soo Min;Choi, Hee Jung;Lim, So Yeon;Park, So Young;Suh, Gee Young;Jeon, Kyeongman
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • Background: Non-invasive positive pressure ventilation (NPPV) ensures adequate gas exchange during bronchoscopy in spontaneously breathing, hypoxemic patients, thus avoiding endotracheal intubation. However, in some patients, endotracheal intubation is eventually required after bronchoscopy. This study investigated the incidence of intubation and predictors of a need for emergency intubation prior to NPPV bronchoscopy initiation. Methods: On a retrospective basis, we reviewed the medical records of 36 patients (median age, 55 years; interquartile range [IQR], 43~65 years) with acute hypoxemic respiratory failure who required NPPV during bronchoscopy between January 2005 and October 2007. Results: All patients were hypoxemic (median $PaO_2/FiO_2$ ratio 155; IQR 90~190), but tolerated bronchoscopy with NPPV support. SOFA score and SAPS II score immediately before NPPV initiation were 4 (3~7) and 36 (30~42), respectively. Seventeen (47%) patients needed endotracheal intubation at a median time of 22 (2~50) hours after bronchoscopy. Patients who needed intubation after bronchoscopy had a higher in-hospital mortality (11 [65%] vs. 4 [21%], p=0.017). Upon multiple logistic regression analysis, the need for intubation after bronchoscopy was independently associated with a $P_aO_2/FiO_2$ ratio (OR, 0.961; 95% CI, 0.924~0.999; p=0.047) immediately before NPPV initiation for bronchoscopy. Conclusion: The severity of the hypoxemia immediately prior to NPPV initiation for bronchoscopy was associated with the need for intubation after bronchoscopy in patients with hypoxemic respiratory failure.

Factors Related to the Development of Myocardial Ischemia During Mechanical Ventilation (인공 호흡기 적용에 따른 심근 허혈의 발생에 관한 연구)

  • Kim, Tae-Hyung;Kim, You-Ho;Lim, Chae-Man;Kim, Won;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.645-653
    • /
    • 1999
  • Introduction : Although myocardial ischemia tends to occur more frequently than can he documented in ventilated patients, it has not been well studied on the factors related to the occurrence of the ischemia. Methods : To investigate the related factors to ischemia development, a prospective study was done in 95 cases with consecutive 73 patients who had received mechanical ventilation(MV) in MICU. In addition to 24 h holter monitoring, echocardiogram, electrolytes, cardiac enzymes, hemodynamic, and gas exchange measurements were done within 24 h after initiation of MV in 69 cases. The measurements were repeated at weaning period in 26 cases. The ischemia was defined by the ST segment changes; up-sloping depression more than 1.5 mm or down-sloping or horizontal depression more than 1.0 mm from isoelectric baseline for 80 ms following J point. Results : Twelve patients(12.6% in 95 cases) developed ischemia in total. The incidence of ischemia development showed an increased tendency in the initial 24 hr after MV (15.9%) and in patients with left-sided heart failure found by echocardiogram (18.2%) compared with that of the weaning period (3.8%) and patients without heart failure (10.9%) (P=0.12, P=0.09, in each). There were no differences in APACHE III score, baseline ECG findings, electrolytes abnormalities, use of inotropics or bronchodilators, presence of sepsis or shock, mode of ventilation, and survival rate according to the development of ischemia. Maximal heart rates and mean arterial pressure also were not different between patients with ($137.2{\pm}30.9/min$, $82.5{\pm}15.9$ mm Hg) and without ischemia ($l29.5{\pm}29.7/min$, $83.8{\pm}17.6$ mm Hg). Conclusion : Although the incidence of myocardial ischemia was 12.6% in total, there were no clinically predictable factors to the development of ischemia during mechanical ventilation.

  • PDF

Impacts of R&D and Smallness of Scale on the Total Factor Productivity by Industry (R&D와 규모의 영세성이 산업별 총요소생산성에 미치는 영향)

  • Kim, Jung-Hwan;Lee, Dong-Ki;Lee, Bu-Hyung;Joo, Won
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.2 no.4
    • /
    • pp.71-102
    • /
    • 2007
  • There were many comprehensive analyses conducted within the existing research activities wherein factors affecting technology progress including investment in R&D vis-${\Box}$-vis their influences act as the determinants of TFP. Note, however, that there were few comprehensive analysis in the industrial research performed regarding the impact of the economy of scale as it affects TFP; most of these research studies dealt with the analysis of the non -parametric Malmquist productivity index or used the stochastic frontier production function models. No comprehensive analysis on the impacts of individual independent variables affecting TFP was performed. Therefore, this study obtained the TFP increase rate of each industry by analyzing the factors of the existing growth accounting equation and comprehensively analyzed the TFP determinants by constructing a comprehensive analysis model considering the investment in R&D and economy of scale (smallness by industry) as the influencers of TFP by industry. First, for the TFP increase rate of the 15 industries as a whole, the annual average increase rate for 1993${\sim}$ 1997 was approximately 3.8% only; during 1999${\sim}$ 2000 following the foreign exchange crisis, however, the annual increase rate rose to approximately 7.8%. By industry, the annual average increase rate of TFP between 1993 and 2000 stood at 11.6%, the highest in the electrical and electronic equipment manufacturing business and IT manufacturing sector. In contrast, a -0.4% increase rate was recorded in the furniture and other product manufacturing sectors. In the case of the service industry, the TFP increase rate was 7.3% in the transportation, warehousing, and communication sectors. This is much higher than the 2.9% posted in the electricity, water, and gas sectors and -3.7% recorded in the wholesale, food, and hotel businesses. The results of the comprehensive analysis conducted on the determinants of TFP showed that the correlations between R&D and TFP in general were positive (+) correlations whose significance has yet to be validated; in the model where the self-employed and unpaid family workers were used as proxy variables indicating the smallness of industry out of the total number of workers, however, significant negative (-) correlations were noted. On the other hand, the estimation factors of variables surrogating the smallness of scale in each industry showed that a consistently high "smallness of scale" in an industry means a decrease in the increase rate of TFP in the same industry.

  • PDF

Growth and Physiological Characteristics of Five Common Foliage Plant Species Grown under the Influence of Static Magnetic Field (정자기장 처리에 따른 실내 관엽식물의 생육 및 생리적 특성 변화)

  • Lee, Seong Han;Woo, Su Young;Kwak, Myung Ja
    • Horticultural Science & Technology
    • /
    • v.30 no.5
    • /
    • pp.484-492
    • /
    • 2012
  • The present study aimed to investigate the effect of static magnetic field (SMF) on the growth and physiological characteristics of common indoor plant species. Five foliage plant species, Spathiphyllum spp., Ardisia pusilla DC., Syngonium podophyllum, Peperomia pereskiifolia, and Pilea cadierei were potted into plastic pot equipped with round type anisotropic sintered NdFeB permanent magnet inside the pot. The surface magnetic flux density of each magnet was 3,500 G. After 6 months of growth period, the biomass accumulations of Spathiphyllum, A. pusilla, and P. cadierei under SMF were statistically higher than those of controls. Tissue water content also increased under the influence of SMF in most species. The photosynthetic rate of Spathiphyllum under SMF significantly increased but other species showed no significant difference compared with control. Although there was no significant increase in the photosynthetic rates of A. pusilla, and P. cadierei, they showed remarkable increase in total fresh weight under SMF. This suggests that the demand of assimilates for normal metabolism could be decreased under magnetic influence and thereby biomass accumulation could be more favored. But this is not always true for all plant species because P. pereskiifolia in this experiment, showed no changes in both photosynthetic rate and biomass accumulation. Leaf nitrogen and chlorophyll contents were enhanced significantly in most plant species under influence of SMF. Chlorophyll a/b ratio also increased by SMF. Although there might be a limitation depending on plant species, these results suggest that long-term exposure to SMF might allow plant to have an enhanced acclimation capacity against environmental fluctuations and optimal application of SMF could increase the practical use of indoor plants such as an attempt to improve indoor air quality.

Variation of Lead Content in Paddy Rice and Soil of Janghang Smelter Area (장항제련소 지역의 토양과 수도체 중 Pb 함량의 변화에 관한 연구)

  • Kim, Seong-Jo;Ryu, Taek-Kyu;Lee, Man-Sang;Yang, Chang-Hyu;Jeon, Kyung-Soo;Beak, Seung-Hwa
    • Korean Journal of Environmental Agriculture
    • /
    • v.11 no.3
    • /
    • pp.185-193
    • /
    • 1992
  • To investigate differences in lead content in soils and paddy rices, affected by air pollutants from the Janghang Smelter, soil samples at the different directions, distances, and depths, surface(0-15cm depth) and subsurface(15-30cm depth) in 1982 and 1990, and rice plants at soil sampling sites in 1990 were separately collected at the Janghang Smelter area affected by combustible waste gas from the smelter chimney. Soil samples were extracted with $4M-HNO_3$ and plant samples were digested with mixture of $HNO_3$ and $HCIO_4$ for analyzing by atomic absorption spectrophotometry. The Pb contents in soils ranged from 10.3 to 644.8mg $kg^{-1}$. The average content in 1990 was higher than that in 1982. The Pb content in soils at sites nearer the center of the smelter was higher than that at sites farther from the center. The highest lead content was found at the east direction, and was low in order of east>north-north east>north east > north. The variation of Pb level in soils at east sites was more considerable than other directions. The Pb level in surface soils was higher than that in subsurface soils. The contaminated radius of Pb was until 3km all at east, north-north east and north east. A significant correlation was found between Pb content in surface soils of 1982 and that in surface soils of 1990, between Pb content in soils and contents of Cd and Zn in soils, and between Pb content in soils and soil properties as organic matter, available silicate, cation exchange capacity, exchangeable $Ca^{++}$, $Mg^{++}$ and $Na^+$. Pb content in brown rice was low in the panicle axis, and brown rice, and Pb content in stem was 3.26 times of that in brown rice. Pb content in brown rice ranged from 2.2 to 9.0 mg $kg^{-1}$.

  • PDF

Early Response of Cardiopulmonary Exercise Test(CPET) in Patients with Locally Advanced Non-Small Cell Lung Cancer Treated with Radiation (방사선 치료 후 폐암환자의 운동부하 심.폐 기능의 초기변화)

  • Shin, Kyeong-Cheol;Lee, Deok-Hee;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.4
    • /
    • pp.466-473
    • /
    • 2000
  • Background : Patients with locally advanced non-small cell lung cancer are often treated with radiation alone or in combination with chemotherapy. Both modalities have a potentially damaging effect on pulmonary function. In order to examine changes in the cardiopulmonary exercise function of patients with locally advanced non-small cell lung cancer before and after conventional radiotherapy, we conducted a prospective study involving patients with such cancer, that had received radiation therapy. Method : Resting pulmonary function test, thoracic radiographic finding and cardiopulmonary exercise test(CPET) were assessed prior to and 4 weeks following radiation therapy in 11 male patients with locally advanced non-small cell lung cancer. Patient with endobronchial mass were excluded. Results : The forces vital capacity (FVC), forced expiratory volume in 1 second ($FEV_1$ and maximal voluntary ventilation (MVV) did not decreased between before and 4 weeks after radiation but the diffusing capacity (DLCO) had decreased by 11% 4 weeks after radiation, which was not statistically significant. No changes in maximal oxygen consumption ($VO_2$max), carbon dioxide production ($VCO_2$), exercise time and work load were attributed to radiation therapy. Follow up cardiopulmonary exercise testing revealed unchanged cardiovascular function, ventilatory function and gas exchange. No difference in cardiopulmonary exercise test performance was observed between pre- and post-radiation. Conclusion : Cardiopulmonary exercise function did not decrease within the short-term after the radiation of patients with locally advanced non-small cell lung cancer.

  • PDF