• Title/Summary/Keyword: gas appliance

Search Result 47, Processing Time 0.021 seconds

Optimal Design of Cylinder Configuration for a 1-Stage Two Cylinder $CO_2$ Compressor (1단 2실린더 $CO_2$ 압축기의 실린더 형상 최적 설계)

  • Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.119-124
    • /
    • 2008
  • Recently, focus has been drawn on natural refrigerants due to increasing concern on global warming. As a consequence, CO2 systems such as a heat pump water heater using CO2 as a refrigerant are rapidly growing on the market. Currently, rolling piston rotary compressors are widely used for CO2 heating and/or refrigeration systems. There are several ways of realizing gas compression structure. They are single stage compression with single cylinder, single stage compression with two cylinders, and two stage compression with two cylinders. In this paper, computer simulation program which was validated for a single stage rotary compressor with one cylinder has been extended for a single stage, two cylinder rotary type. Numerical investigation has been made on optimal design for the cylinder configuration using the extended simulation program. For a single stage two cylinder rotary compressor having a displacement volume of 4 cc for each cylinder, compressor efficiency has been found to be maximum when the cylinder radius and height are 31mm and 10mm, respectively.

  • PDF

Study of Thermal Conductivity and Mechanical Property of Elastic Epoxy (탄성형 에폭시의 열전도율 및 기계적 특성에 대한 연구)

  • Lee, Kwan-Woo;Lee, Kyoung-Yong;Choi, Yong-Sung;Park, Bok-Ki;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.319-322
    • /
    • 2004
  • In this paper, we studied on the thermal conductivity and a mechanical property of the elastic epoxy. According to industrial development, insulation materials have various properties. They are solid, liquid, gas state, there are various type. Epoxy, a kind of insulation material, demand of not only high hardness but also elastic property. When the electric current flows into the conductor and the place where the heat occurs, this heat becomes the cause which shortens the life of the electrical appliance. Therefore, for the heat occurred transmit quickly, thermal conductivity of the insulation material is highly demanded. We studied on the thermal conductivity of elastic epoxy on the high voltage. In this result, thermal conductivity confirmed that it followed thermal property of mixed epoxy and addictives. Hardness is decreased when addictives increased.

  • PDF

An Experimental Study on the High Performance Optimal Discharge System of a Rotary Compressor for an Air Conditioner using alternative Refrigerant R410a (대체냉매 공기조화기용 로터리 압축기의 성능향상을 위한 최적 토출계에 관한 실험적 연구)

  • Youn, Young;Chung, Jin-Taek;Min, Man-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.96-105
    • /
    • 2001
  • R410a which is one of HFC refrigerants is being considered to be a promising replacement for R22 widely used in domestic air conditioners. The rolling piston type rotary compressors for R410a have lower energy efficiency than those for R22 because of the high pressure difference between a suction chamber and a discharge chamber in the compression mechanism. in addition, the re-expansion gas loss of the rotary compressor for R410a which occurs a ta clearance volume in a discharge port becomes larger than that for R22 due to high density of R410a refrigerant. Therefore, Pressure-Volume analyses for various design parameters of a discharge system were carried out to improve efficiency of a R410a rotary compressor. The results such as performance dta, over-compression loss, and re-expansion loss were acquired by P-V analyses and analyzed quantitatively. As a conclusion, the optimal specifications of several design parameters of a discharge system were obtained by analyzing P-V diagrams.

  • PDF

Enhanced TPH Degradation of Diesel-Contaminated Soil by Microwave Heating (디젤오염토양의 TPH 분해를 위한 마이크로파의 가열특성)

  • Jung, Byung-Gil;Kim, Dae-Yong;Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.17 no.5
    • /
    • pp.479-484
    • /
    • 2008
  • The application of microwave technology has been investigated in the remediation of diesel-contaminated soil. The paper deals with economic assessment by means of cost analysis and degradation characteristics at different microwave powers for total petroleum hydrocarbon (TPH) in diesel contaminated soils. The soils from S Mountain around the D University were sampled. The samples were screened with 2.0 mm mesh and dried for 6 hours before the diesel was added into the dried soils. The diesel-contaminated soil (3,300 mg THP/kg soil) was prepared with diesel (S Co.). The drying process was carried out in a microwave oven, a standard household appliance with a 2,450 MHz frequency and 700 W of power. The experiments were conducted from 0 to 20 minutes as the microwave powers increased from 350W to 500W to 700W. The concentrations of TPH were analysed using a gas chromatography/mass spectrometer (GC/MS). The initial concentration of TPH was 3,300 mg TPH/kg soil. The weight of contaminated soil was 200g. The concentration of TPH was decreased to 1,828 mg TPH/kg soil (44.7%), 1,347 mg TPH/kg soil (59.2%) and 1,014 mg TPH/kg soil (69.3%) at 350W, 500W and 700W for 15 minutes respectively. In addition, the curve was best fit with first order kinetics using the least-square method. The ranges of a first order rate constant k and r-square were $0.0298{\sim}0.0375min^{-1}$ and $0.9373{\sim}0.9541$ respectively.

Secure Data Transaction Protocol for Privacy Protection in Smart Grid Environment (스마트 그리드 환경에서 프라이버시 보호를 위한 안전한 데이터 전송 프로토콜)

  • Go, Woong;Kwak, Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.8
    • /
    • pp.1701-1710
    • /
    • 2012
  • Recently, it has been found that it is important to use a smart grid to reduce greenhouse-gas emissions worldwide. A smart grid is a digitally enabled electrical grid that gathers, distributes, and acts on information regarding the behavior of all participants (suppliers and consumers) to improve the efficiency, importance, reliability, economics, and sustainability of electricity services. The smart grid technology uses two-way communication, where users can monitor and limit the electricity consumption of their home appliances in real time. Likewise, power companies can monitor and limit the electricity consumption of home appliances for stabilization of the electricity supply. However, if information regarding the measured electricity consumption of a user is leaked, serious privacy issues may arise, as such information may be used as a source of data mining of the electricity consumption patterns or life cycles of home residents. In this paper, we propose a data transaction protocol for privacy protection in a smart grid. In addition, a power company cannot decrypt an encrypted home appliance ID without the user's password.

Performance Analysis of a $CO_2$ Two-Stage Twin Rotary Compressor ($CO_2$ 2단 트윈 로타리 압축기 성능해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • Analytical investigation on the performance of a two stage twin rotary compressor for $CO_2$ heat pump water heater system has been carried out. A computer simulation program was made based on analytical models for gas compression in control volumes, leakages among neighboring volumes, and dynamics of moving elements of the compressor. Calculated cooling capacity, compressor input, and COP were well compared to those of experiments over the compressor speeds tested. For the operating condition of suction pressure of 3 MPa, and discharge pressure of 9 MPa, and compressor inlet temperature of $35^{\circ}C$, the compressor efficiency was calculated to be 80.2%: volumetric, adiabatic, and mechanical efficiencies were 88.3%, 93.2%, and 92.7%, respectively. For the present compressor model, volumetric and adiabatic efficiencies of the second stage cylinder were lower by about $6{\sim}7%$ than those of the first stage mainly due to the smaller discharge port at the second stage. Parametric study on the discharge port size showed that the compressor performance could be improved by 3.5% just by increasing the discharge port diameter by 20%.

A Study for Performance Estimation Standard and Standardization of u-IT Convergence Equipment (u-IT Convergence 기기의 성능평가기준과 표준화 연구)

  • Chun, Woo-Sung;Park, Dea-Woo;Lee, Sang-Ick;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.457-460
    • /
    • 2009
  • u-IT Convergence appliances study and are developed in communication by development of u-IT technology, broadcasting, portal, contents, equipment and all fields of business such as solution. This treatise presents valuation basis of, economic performance, administration sex etc. by temperature, pressure, own, storehouse, gas, justice for humidity sensors and valuation basis that define u-IT Convergence, and sense information u-IT Convergence devices and terminal. Also, studied standardization standard of u-IT Convergence network appliance that follow in valuation basis for u-IT Convergence devices. Is going to contribute establish value as estimation product that equip stability and authoritativeness through correct certification assessment for technological development and appliances on Ubiquitous information-oriented society through this research and accomplish standardization.

  • PDF