• 제목/요약/키워드: gap sensor

검색결과 402건 처리시간 0.03초

양면 축방향 영구자석 전동기에서 자속위치 검출에 따른 특성 (Characteristic of Dual Air Gap AFPM along Flux Position Estimation)

  • 홍문환;김철호;이우석;공정식;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.828-830
    • /
    • 2002
  • Axial Flux Permanent Magnet motor could widely be used for low speed and high torque applications. In this paper, to analyse the sensor positioning effect of AFPM motor which has a new concentric winding method and to calibrate the switching timing according to speed, prototype motor is manufactured. As a result of experiment, advance angle from 30 degree to 45 degree of sensor position is more proper. So, this results can be used for design of sensor position to improve characteristic of the dual gap AFPM with coreless and slotless.

  • PDF

자기장 센서를 이용한 갭간격이 없는 박판 맞대기 용접부의 용접선 추적 장치 (Joint tracking system for butt joint welding process using eddy current sensors with the condition of no gap distance)

  • 김영선;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.836-839
    • /
    • 1997
  • In recent years, much progress has been made in the automation of welding coped with a variety of highly flexible sensors. Among these sensors, only the eddy current sensor can detect the center location of the butt joint whose gap distance is zero. Thus, in this study the eddy current sensor is used to develop a robust and useful joint tracking system. The developed system is tested to qualify the performance of the system and seam tracking algorithm is proposed and two simulation are executed to show the performance of the proposed tracking algorithm.

  • PDF

자속 센서를 이용한 농형 유도전동기의 진동검출 기법 (A Method for Vibration Detection of Squirrel Cage Induction Motors Using the Flux Sensor)

  • 황돈하;이상화;한상보;선종호;강동식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1057-1058
    • /
    • 2007
  • This paper proposes an alternative vibration detection method in a squirrel-cage induction motor using flux sensors. The air-gap flux will be changed when mechanical vibration occurs by bearing fault as well as broken rotor bar and air-gap eccentricity. For detecting those flux variations due to vibration, search coils are installed at stator slots. The induction motor with 380 [V], 7.5 [kW], 4 [Poles], 1,760 [rpm] ratings is used. Magnitudes and distortion of the induced voltage from flux sensors are used to discriminate faulted types. As a result, the flux sensor has been proven to be useful for vibration detection. It is compared to the result with vibration sensor as well.

  • PDF

Effective Sensing Volume of Terahertz Metamaterial with Various Gap Widths

  • Park, Sae June;Yoon, Sae A Na;Ahn, Yeong Hwan
    • Journal of the Optical Society of Korea
    • /
    • 제20권5호
    • /
    • pp.628-632
    • /
    • 2016
  • We studied experimentally and theoretically the vertical range of the confined electric field in the gap area of metamaterials, which was analyzed for various gap widths using terahertz time-domain spectroscopy. We measured the resonant frequency as a function of the thickness of poly(methyl methacrylate) in the range 0 to 3.2 μm to quantify the effective detection volumes. We found that the effective vertical range of the metamaterial is determined by the size of the gap width. The vertical range was found to decrease as the gap width of the metamaterial decreases, whereas the sensitivity is enhanced as the gap width decreases due to the highly concentrated electric field. Our experimental findings are in good agreement with the finite-difference time-domain simulation results. Finally, a numerical expression was obtained for the vertical range as a function of the gap width. This expression is expected to be very useful for optimizing the sensing efficiency.

약물 투여에 따른 기니피그 대장 운동 측정을 위한 압력센서 개발 (Development of Pressure Sensor for Identifying Guinea Pig's Large Intestinal Motility Caused by Drug)

  • 박재순;박정호;김응보;조성환;장수정;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제29권1호
    • /
    • pp.23-29
    • /
    • 2016
  • In this paper, in order to quantify the peristalsis occurrence in a guinea pig's large intestine, a miniaturized air-gap capacitive pressure sensor was fabricated through micro-electro-mechanical system (MEMS). The proposed pressure sensor is a two-layered biocompatible polyimide substrate consisting of an air-gap capacitive plates between the substrates. The proposed pressure sensor was designed with a careful consideration of the structure and motility mechanism of the guinea pig's large intestine. Artificial pellets were mounted on a prototype pressure sensor to provide some redundancies in the form of size and shape of the guinea pig feces. Capacitance of a prototype sensor was recorded to be 2.5 ~ 3 pF. This capacitance value was later converted to count value using a lab fabricated data conversion system. Sensitivity of the pressure sensor was recorded to be below 1 mmHg per atmospheric pressure. During in vivo testing, artificial peristalsis caused by drug injection was measured by inserting the prototype pressure sensor into the guinea pig's large intestine and pressure data obtained due to artificial peristalsis was graphed using a labview program. The proposed pressure sensor could measure the pressure changes in the proximal, medial, and distal parts of the large intestine. The results of the experiment confirmed that pressure changes of guinea pig's large intestine was proportional to the degree of drug injection.

횡자속 영구자석형 자기부상전자석 시스템의 공극제어에 관한 연구 (A Study on Air-gap Control for Transverse Flux Permanent Magnet Type Magnetic Levitation Electromagnet System)

  • 이재원;김명재;황선환
    • 한국산업융합학회 논문집
    • /
    • 제26권6_2호
    • /
    • pp.1127-1134
    • /
    • 2023
  • In this paper, we proposes a study on air gap control for magnetic levitation of transverse flux permanent magnet electromagnets. In general, mechanical systems have a high failure rate of bearings. Bearings in particular are problematic because they have high surface wear rate and degradations. To solve this problem, replacing the bearing with a magnetic levitation electromagnet system can provide lightweight and efficiency improvements. However, precise air gap control is essential to control the magnetic levitation electromagnet system. Therefore, in this paper, we identify the instable cause of gap control through a mathematical modeling and verify through experiment a control algorithm that can use compensation.

혈압 측정을 위한 외팔보형 접촉힘 센서 어레이 (A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement)

  • 이병렬;정진우;전국진
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

비선형성의 개선을 위한 Capacitive pressure sensor의 Touch mode 방식에 대한 유한요소 해석 (Finite Element Analysis of Capacitive pressure sensor with Touch mode for improving non-linearity)

  • 김도형;오재근;최범규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2087-2089
    • /
    • 2004
  • Capacitive pressure sensor는 Piezo type sensor에 비해 온도의 영향이 적어 공업계측, 전기용품 등 그 용도가 다양하여 폭넓게 사용되어지고 있지만, 측정값의 비선형성이 존재하여 측정값에 대한 신뢰도가 떨어지는 단점이 있다. 본 연구에서는 기존 capacitive pressure sensor의 비선형적 output을 개선하기 위한 방법으로 touch mode capacitive pressure sensor를 제안하였다. 또한, 실제 Device제작에 앞서 FEM 해석을 수행하였다. 2mm X 2mm 크기의 diaphragm, $25{\mu}m$의 두께, $20{\mu}m$의 gap을 갖는 Sensor를 Simulation하였으며 설계 변수를 추출하여 각각의 설계변수에 대한 해석을 실시하였다. 그 결과 15.2psi${\sim}$31psi의 영역에서 8.58pF${\sim}$54.31pF의 capacitance가 선형적으로 나타나는 sensor임을 확인하였다.

  • PDF

와전류 센서를 이용한 금속 모재 선별에 관한 연구 (A Study on sorting out base metal using eddy current sensor)

  • 이길승;김태옥;김화영;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1788-1792
    • /
    • 2005
  • Eddy current sensor is representative instrument measuring gap to base metal and sensing trouble in base metal. The existing eddy current sensor works as measuring variance of sensor coil's inductance. But, sensor coil have phenomenon that not only inductance but also real resistance varies in real action. Conductivity and Permeability are main variable in sensor coil's varying impedance(inductance, real resistance). By searching relationship between conductivity-permeability and sensor coil's impedance, eddy current sensor gain advantage of elevation of accuracy, removal of alignment to each base metal, and continuous sensing to varying base metal.

  • PDF

상전도 흡인식 자기부상열차 분기기 주행시의 부상공극변동과 분기기 거더의 진동 특성 (Vibration characteristics between levitation air-gap and switching system girders)

  • 신현재;이종민;최장영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.824-829
    • /
    • 2011
  • EMS-type Maglev vehicle maintains constant levitation air-gap between electromagnet and guideway by using gap sensor. The other words, when Maglev vehicles levitating over the guideway, mass of the vehicle effects through 1st (electromagnetic air-gap control) and 2nd (air-spring) suspension to grider. Resonace between electromagnetic suspension and grider could be occurred, which causes instability and poor ridecomfort. This paper is to test the dymanic interaction between levitation air-gap and switching system grider that has less mass and high natural frequencies than other type of general girders.

  • PDF