• Title/Summary/Keyword: gap measurement

Search Result 699, Processing Time 0.036 seconds

Fabrication of Nickel-based Piezoelectric Energy Harvester from Ambient Vibration with Micromachining Technology (마이크로 머시닝 기술을 이용한 니켈기반의 압전 진동형 에너지 하베스터 제작)

  • Cha, Doo-Yeol;Lee, Jai-Hyuk;Chang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.1
    • /
    • pp.62-67
    • /
    • 2012
  • Owing to the rapid growth of mobile and electronic equipment miniaturization technology, the supply of micro mobile computing machine has been fast raised. Accordingly they have performed many researches on energy harvesting technology to provide promising power supply equipment to substitute existing batteries. In this paper, in order to have low resonance frequency for piezoelectric energy harvester, we have tried to make it larger than before by adopting nickel that has much higher density than silicon. We have applied it for our energy harvesting actuator instead of the existing silicon based actuator. Through such new concept and approach, we have designed energy harvesting device and made it personally by making with micromachining process. The energy harvester structure has a cantilever type and has a dimension of $10{\times}2.5{\times}0.1\;mm^3$ for length, width and thickness respectively. Its electrode type is formed by using Au/Ti of interdigitate d33 mode. The pattern size and gap size is 50 ${\mu}m$. Based on the measurement of the nickel-based piezoelectric energy harvester, it is found to have 778 Hz for a resonant frequency with no proof mass. In that resonance frequency we could get a maximum output power of 76 ${\mu}W$ at 4.8 $M{\Omega}$ being applied with 1 g acceleration.

A Study on Stress Assessment of Standing Gas Pipeline Subjected to Ground-Subsidence (지반 침하를 고려한 도시가스 입상배관의 응력평가)

  • Kil, Seong-Hee;Kim, Byung-Duk;Kwon, Jeong-Rock;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.1-8
    • /
    • 2013
  • In this study, 120 cases of damage due to ground subsidence of city gas pipeline which is hanging on apartment outer wall were investigated. From the survey results, it was determined to be approximately 100m~200mm ground subsidence occurred and at severe damage, pipeline was cut and the gap was about 50mm between two cut pipeline. Device for measuring the amount of deformation of standing gas pipeline was designed and fabricated. And installed it on apartment outer wall for measuring the deformation due to ground subsidence, after 5 months measurement the amount of ground subsidence was measured to 1.3mm. Stress assessment was conducted based on results of ground subsidence occurred on standing gas pipeline.

Interfacial Damage Sensing and Evaluation of Carbon and SiC Fibers/Epoxy Composites with Fiber-Embedded Angle using Electro-Micromechanical Technique (Electro-Micromechanical시험법을 이용한 섬유 함침 각에 따른 탄소와 SiC 섬유강화 에폭시 복합재료의 계면 손상 감지능 및 평가)

  • Joung-Man Park;Sang-Il Lee;Jin-Woo Kong;Tae-Wook Kim
    • Composites Research
    • /
    • v.16 no.2
    • /
    • pp.68-73
    • /
    • 2003
  • Interfacial properties and electrical sensing fer fiber fracture in carbon and SiC fibers/epoxy composites were investigated by the electrical resistance measurement and fragmentation test. As fiber-embedded angle increased, the interfacial shear strength (IFSS) of two-type fiber composites decreased, and the elapsed time takes long until the infinity in electrical resistivity. The initial slope of electrical resistivity increased rapidly to the infinity at higher angle, whereas electrical resistivity increased gradually at small angle. Furthermore, both fiber composites with small embedded angle showed a fully-developed stress whitening pattern, whereas both composites with higher embedded angle exhibited a less developed stress whitening pattern. As embedded angle decreased, the gap between the fragments increased and the debonded length was wider for both fiber composites. Electro-micromechanical technique could be a feasible nondestructive evaluation to measure interfacial sensing properties depending on the fiber-embedded angle in conductive fiber reinforced composites.

Vibration Sensing and Impact Location Measurement Using Intensity-Based Optical Fiber Vibration Sensor (광강도형 광섬유 진동센서를 이용한 진동감지 및 충격위치 측정)

  • 양유창;황운봉;박현철;한경섭
    • Composites Research
    • /
    • v.13 no.5
    • /
    • pp.1-9
    • /
    • 2000
  • An intensity-based optical fiber vibration sensor is applied to monitor the structural vibration and detect impact locations on a plate. Optical fiber vibration sensor is constructed by placing two cleaved fiber end, one of which is cantilevered in a hollow glass tube. The movement of the cantilevered section lags behind the rest of the sensor in response to an applied vibration and the amount of light coupled between the two fibers is thereby modulated. For vibration sensing, optical fiber vibration sensor is mounted on the carbon fiber composite beam and its response is investigated to free and forced vibration. In impact location detection, four optical fiber vibration sensors whose location is predetermined are placed at chosen positions and the different arrival times of impact-generated vibration signal are recorded by an FFT analyzer. Impact location can be calculated from these time delays. Experimental results show that optical fiber vibration sensor signals coincide with gap sensor in vibration sensing. The precise location of impact can be detected on an acrylate plate.

  • PDF

Experimental Study of Internal Distribution of Temperature and Relative Humidity in Notebook LCD Module (노트북용 액정 모듈 내부의 온도 및 상대 습도 변화에 관한 실험적 연구)

  • Kim, Tae-Woo;Kim, Gi-Bin;Lee, Jae-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.2
    • /
    • pp.217-221
    • /
    • 2012
  • As a part of basic research to improve screen quality, which deteriorates when strain occurs within optical sheets in LCD modules for laptop computers, a measurement system is needed to analyze the influence of heat and moisture, which are the main factors causing the strain. It is assumed that the existence of an air gap less of than 0.5 mm inside the LCD module causes humid air from outside to permeate through the module. To investigate this phenomenon, in this study a thin printed circuit board (PCB) of compact sensors that measure temperature and humidity is inserted into LCD modules, and thus, the changes in temperature and humidity can be analyzed in real time. The results can be used as basic data for simulation of the deformation behavior and structural design of LCD modules in the future.

Statistical Observation for Measurement of Bone Mineral Density of the Spine in Korean Women Screening in a Health Clinic (건강진단상 여성골밀도 측정의 통계학적 관찰)

  • Kim, Hee-Seup;Park, Lee-Gap;Lee, Jung-Sook;Lee, Seung-Sub
    • The Journal of the Korean life insurance medical association
    • /
    • v.15
    • /
    • pp.93-98
    • /
    • 1996
  • During the period from January to September 1995, 1.010 Women(premenopausal 466 cases and postmenopausal 544 cases) of employees and family member were observed for bone mineral density of lumbar spine using Dual Energy X-ray Absorptiometry(DEXA) at Medical Department of Korea Life Insurance Co. Ltd. Results obtained were as follows: 1) In premenopausal women 466 cases, the ratio of decreased bone mineral density of lumbar spine according to age groups shows 3rd decade were 5 cases(9.80%) among 51 cases, 4th decade were 31 cases(8.68%) among 357 cases, and 5th decade were 10 cases(17.24%) among 58 cases. 2) In postmenopausal women 544 cases, the ratio of decreased bone mineral density of lumbar spine according to age groups shows 3rd decade were 2 cases(66.67%) among 3 cases, 4th decade were 28 cases(31.11%) among 90 cases, 5th decade were 168 cases(48.70%) among 345 cases, 6th decade were 73 cases(73.0%) among 100 cases, and 7th decade were 4 cases(66.67%) among 6 cases. 3) Bone mineral density begins to decrease with age as early as the 4th decade, even in the premenopausal state. In the 4th decade, premenopausal women exhibit an average 8.68% decrease in bone density. Postmenopausal women in this same age group, however, demonstrate an average bone density decrease of 31.11%.

  • PDF

Effects of Doping Concentrations and Annealing Temperatures on the Electrical and Optical Properties of Ga-doped ZnO Thin Films by Sol-gel Method (Sol-gel 법으로 제작한 Ga-doped ZnO 박막의 도핑 농도와 열처리 온도가 전기적 및 광학적 특성에 미치는 효과)

  • Kang, Seong-Jun;Joung, Yang-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.3
    • /
    • pp.558-564
    • /
    • 2012
  • We fabricated Ga doped ZnO (GZO) thin films on the glass substrate (Eagle 2000) with various of Ga doping concentration and annealing temperatures using sol-gel method, electrical and optical properties were investigated. When the GZO thin films doped with 1 mol% of Ga and annealed at $600^{\circ}C$, the excellent (002) orientation was observed. In the results of Hall measurement, carrier concentration decreased and resistivity increased due to segregation effect with increasing of the Ga doping concentration. The largest carrier concentration and lowest resistivity were $9.13{\times}10^{18}cm^{-3}$ and $0.87{\Omega}cm$, respectively, in the GZO thin films doped with 1 mol% Ga and annealed at $600^{\circ}C$. All films is higher than 80 % in the visible light region. Energy band gap narrowing due to Burstein-Moss effect was observed with increasing of Ga doping concentration from 1 to 4 mol%.

A Study of Polarity Effect of Parallel Plate Type ionization Chamber with Different Volume (평행평판형 전리함의 두 전극간의 거리에 따른 극성효과 연구)

  • 윤형근;신교철
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.69-73
    • /
    • 2002
  • Exposure measurement data with parallel plate ionization chambers were known to depend on the polarity ($k_{pol}$) effect. In this work, the polarity effect were investigated for three parallel plate ionization chambers with different volume. The ionization chamber was fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far were 0.9, 1.9, and 3.1 co. High voltage generator was fabricated using the conventional 9 V batteries to apply the high voltage (300-500 V) to the electrode of the parallel plate ionization chamber. The gap between two electrodes ranged from 3, 6, and 10mm. As the result of our experiment, the polarity effect was within 0.5% in photon beam and 1% to 3.5% in the electron beams. Among electron beams, 16 MeV beam, which had highest energy, showed less polarity effect than electron beams with other energies.

  • PDF

Growth of zinc oxide thin films by oxygen plasma-assisted pulsed laser deposition

  • Pak, Sang-Woo;Suh, Joo-Young;Lee, Dong-Uk;Kim, Eun-Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.208-208
    • /
    • 2010
  • Zinc oxide (ZnO) is a functional material with interesting optical and electrical properties, a wide band gap (more than 3.3 eV), a high transmittance in the visible light region, piezoelectric properties, and a high n-type conductivity. This material has been investigated for use in many applications, such as transparent electrodes, blue light-emitting diodes, and ultra-violet detector. ZnO films grown under low oxygen pressure by thin film deposition methods show low resistivity and large free electron concentration. Therefore, reducing the background carrier concentration in ZnO films is one of the major challenges ahead of realizing high-performance ZnO-based optoelectronic devices. In this study, we deposited ZnO thin films on sapphire substrates by pulsed laser deposition (PLD) with employing an oxygen plasma source to decrease the background free-electron concentration and enhance the crystalline quality. Then, the substrate temperature was varied between 200 'C to 900 'C The vacuum chamber was initially evacuated to a pressure of $10^{-6}$ Torr, and then a pure $O_2$ gas was introduced into the chamber and the pressure during deposition was maintained at $10^{-2}$ Torr. Crystallinity and orientation of ZnO films were investigated by X-ray diffraction (XRD). The film surface was analyzed with atomic force microscope (AFM). And electrical properties were measured at room temperature by Hall measurement.

  • PDF

Rapid and Accurate Measurement of Diffusion Length of Minority Carriers of CIGS Solar Cells (CIGS 태양전지의 소수캐리어 확산 거리에 대한 새로운 측정 방안 연구)

  • Lee, Don Hwan;Kim, Young Su;Mo, Chan Bin;Nam, Jung Gyu;Lee, Dong Ho;Park, Sung Chan;Kim, Byoung June;Kim, Dong Seop
    • Current Photovoltaic Research
    • /
    • v.2 no.2
    • /
    • pp.59-62
    • /
    • 2014
  • Minority carrier diffusion length is one of the most important parameters of solar cells, especially for short circuit current density (Jsc). In this report, we proposed the calculating method of the minority carrier diffusion length ($L_n$) in CIGS solar cells through biased quantum efficiency (QE). To verify this method's reliability, we chose two CIGS samples which have different grain size and calculated $L_n$ for each sample. First of all, we calculated out that $L_n$ was 56nm and 97nm for small and large grain sized-cell through this method, respectively. Second, we found out the large grain sized-cell has about 7 times lower defect density than the small grain sized-cell using drive level capacitance profiling (DLCP) method. Consequently, we confirmed that $L_n$ was mainly affected by the micro-structure and defect density of CIGS layer, and could explain the cause of Jsc difference between two samples having same band gap.