• Title/Summary/Keyword: gap measurement

Search Result 700, Processing Time 0.033 seconds

An Experimental Study on the Influence of the Internal Cavity and Gap on the Bell Acoustics (내부 공동과 간극이 종 음향에 미치는 영향에 대한 실험적 연구)

  • Jeong, Won-Tae;Kang, Yeon-June;Kim, Seock-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.822-827
    • /
    • 2010
  • In this study, it is experimentally investigated how bell acoustics are influenced by the internal cavity of the bell and the gap between the bell bottom and the floor. Acoustic transmission function and natural frequency of a test bell are measured and analysed. Experimental study is conducted to evaluated how the resonance effect influences the bell sound and how the bell sound is different according to the striking condition and the measurement direction. Acoustic resonance frequency of the cavity-gap system is predicted by boundary element analysis using SYSNOIS and the validity of the predicted result is verified by experiment. The result of the study could be applied to determine the optimal gap size which makes the bell sound strong and long.

Measurement of Refractive Index of Solid Medium by Critical Angle Method When Air Gap is Present

  • Lim, Hwan-Hong;Kwon, Moon-Soo;Choi, Hee-Joo;Kim, Byoung-Joo;Cha, Myoung-Sik
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.210-214
    • /
    • 2008
  • A critical angle method was used to measure the index of refraction of a solid medium when an air gap between the prism and the medium is present. The gap effect was analyzed both numerically and experimentally. Since the total internal reflection is severely disturbed by the large gap, determination of the critical angle and the resulting refractive index becomes ambiguous and inaccurate. By using an index matching fluid, we could determine the index of refraction with an uncertainty of ${\pm}2{\times}1^{-3}$ even when the gap is as large as 1 ${\mu}m$.

Initial Release of Nuclides from Spent PWR Fuels

  • Kim, S. S.;K. S. Chun;Kim, Y. B.;Park, J. W.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.238-244
    • /
    • 2004
  • The relationship between the leaching and gap inventory of spent fuel has been studied. When a specimen of J44H08 spent PWR fuel with 38 GWD/MTU has been leached in the synthetic granitic groundwater in Ar atmosphere, the released fraction of cesium was increased rapidly up to 0.7% at around 500 days and stayed below 0.8% until 3 years. This 0.7% of cesium might be released from the gap in this fuel. The measurement of gap inventory with C15I08 spent PWR fuel, having 35 GWD/MTU and 0.22% of fission gas release, was also determined near 0.6% for the cesium, which is a similar fraction of cesium released from the leaching experiment with J44H08 fuel. Its gap inventories of strontium and iodine were about 0.03 and less than 0.2% respectively. Respective fractions of cesium and strontium in grain boundary of C15I08 were 0.78, 0.09%.

  • PDF

A Study on Direct Current Measurement Using Magneto-Optical LMF Method (자기장학 누설자속법을 응용한 직류전류계측법에 관한 연구)

  • Lee, Jin-Yi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.566-572
    • /
    • 2004
  • It is necessary to measure the direct current with a non-contact methodology for the liquid or gas phase, as welt as the conducting metals. This paper described a theoretical consideration and experimental verification for a non-contact quantitative direct current measurement system using the Faraday effect and magnetic flux leakage. The leakage of magnetic flux occurs around a gap when a ferromagnetic core including the discontinuous gap is magnetized. Two large anisotropic domains in a magneto-optical film are occurred by the vertical component of leaked magnetic flux and the domain walls are paralleled to the center of the gap. Here, the symmetrical arrangement of domains are deflected when a vertical magnetic field is applied to the magneto-optical film. The domain wall of the magneto-optical film are relocated when a measuring current passes through the ferromagnetic core. Therefore, a direct current passing through the core can be determined quantitatively by the measurement of moving distance of the domain wall.

Rapid Cooling Mechanism Utilizing Acoustic Streaming Generated by Ultrasonic Vibrations (초음파 진동에 의해 발생된 음향유동을 활용한 급속냉각 메카니즘)

  • Loh, Byoung-Gook;Kwon, Ki-Jung;Lee, Dong-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1057-1066
    • /
    • 2006
  • Acoustic streaming Induced by longitudinal vibration at 30 kHz is visualized for a test fluid flow between the stationary glass plate and ultrasonic vibrating surface with particle imaging velocimetry (PIV) To measure an increase in the velocity of air flow due to acoustic streaming, the velocity of air flow in a gap between the heat source and ultrasonic vibrator is obtained quantitatively using PIV. The ultrasonic wave propagating into air in the gap generates steady-state secondary vortex called acoustic streaming which enhances convective cooling of the stationary heat source. Heat transfer through air in the gap is represented by experimental convective heat transfer coefficient with respect to the gap. Theoretical analysis shows that gaps for maximum heat transfer enhancement are the multiple of half wavelength. Optimal gaps for the actual design are experimentally found to be half wavelength and one wavelength. A drastic temperature variation exists for the local axial direction of the vibrator according to the measurement of the temperature distribution in the gap. The acoustic streaming velocity of the test fluid in the gap is at maximum when the gap agrees with the multiples of half wavelength of the ultrasonic wave, which are specifically 6 mm and 12 mm.

Exploration and Development of SERVQUAL

  • Kim, Yong-Pil;Kim, Kye-Wan;Yun, Deok-Gyun
    • International Journal of Quality Innovation
    • /
    • v.4 no.1
    • /
    • pp.116-130
    • /
    • 2003
  • The gap-based SERVQUAL model is a popular service quality determinant due to its superior diagnostic capacity over alternative explanatory frameworks. However, some researchers criticize the performance of the SERVQUAL model and propose alternative service Quality measurement constructs. Nevertheless, it is argued that the superior diagnostic capacity of SERVQUAL is its key strength; and that any criticism made of it when making comparison with alternative models does not reflect the differing nature of scales of statistical analysis. Arguably, the only limitation of a gap-based model is misinterpretation of customers' evaluation and perception of a service. In this research, the gap score is transformed into a ratio score. Also, empirical tests and implications are presented to support this alternative contribution to the body of knowledge.

Elucidation of triggering characteristics for a trigatron spark gap by measuring UV light (자외선측정(紫外線測定)에 의한 트리거트론시동특성(始動特性)의 해명(解明))

  • Ko, K.C.;Ishii, S.;Chang, Y.M.;Kang, H.B.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.142-144
    • /
    • 1989
  • Triggering characteristics of a trigatron spark gap have been studied by measuring self-emission UV light. By combining the measurement of the UV light with that of the trigger gap voltage and the lain discharge current, we distinguished clearly the differences between the trigatron operations in which the lain discharge occurs after the trigger discharge in the case of sale polarity between the trigger pin and the lain electrode at the opposite side, and the lain gap breakdown takes place before the formation of the trigger spark in the case of different polarity. We show the observation of UV radiation with the other electromagnetic measurements is a simple and reliable scheme to investigate the triggering properties of the trigatron spark gaps.

  • PDF

Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor (중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발)

  • Jung, H.K.;Lee, D.H.;Lee, Y.S.;Huh, H;Cheong, Y.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.164-170
    • /
    • 2004
  • Liquid Injection Nozzle(LIN) tube and Calandria tube(CT) in pressurized Heavy Water Reactor (PHWR) are .ross-aligned horizontally. These neighboring tubes can contact each other due to the sag of the calandria tube resulting from the irradiation creep and thermal creep, and fuel load, etc. In order to judge the contact which might be the safety concern, the remote field eddy current (RFEC) technology is applied for the gap measurement in this paper. LIN can be detected by inserting the RFEC probe into pressure tube (PT) at the crossing point directly. To obtain the optimal conditions of the RFEC inspection, the sensitivity, penetration and noise signals are considered simultaneously. The optimal frequency and coil spacing are 1kHz and 200mm respectively. Possible noises during LIN signal acquisition are caused by lift-off, PT thickness variation, and gap variation between PT and CT. The simulated noise signals were investigated by the Volume Integral Method(VIM). Signal analysis on the voltage plane describes the amplitude and shape of LIN and possible defects at several frequencies. All the RFEC measurements in the laboratory were done in variance with the CT/LIN gap and showed the relationship between the LIN gap and the signal parameters by analyzing the voltage plane signals.