• Title/Summary/Keyword: gamma-radiation sensitivity

Search Result 119, Processing Time 0.024 seconds

Induction of Micronuclei in Human and Mouse Lymphocytes Irradiated with Gamma Radiation and Effect of Panax ginseng C.A. Meyer (마우스와 사람 림프구에서 방사선에 의한 미소핵의 형성 및 고려인삼의 효과)

  • Kim, Sung-Ho;Oh, Heon;Lee, Song-Eun;Lee, Yun-Sil;Kim, Tae-Hwan;Jeong, Kyu-Sik;Ryu, Si-Yun
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.153-160
    • /
    • 1997
  • The frequencies of ${\gamma}$-ray-induced micronuclei (MN) in cytokinesis-blocked (CB) lymphocytes at several doses were measured in three donors of human and C57BL/6 mice. Measurements performed after irradiation showed a dose-related increases in MN frequency in each of the donors studied. The relative sensitivity of mouse in spleen lymphocytes (SLs) compared with human peripheral blood lymphocytes (PBLs) was estimated by best fitting linear-quadratic model based on the radiation-induced MN data over the range from 0 cGy to 400 cGy. In the case of MN frequency with 0.2 per CB cell, the relative sensitivity of mouse SLs was 1.67. Compared with the radiation-induced MN formation in the PBLs of human, the SLs of mouse were more radiosensitive. Using this MN assay with human PBLs and mouse SLs, studies were performed to determine whether the water fraction of ginseng (Panax ginseng C.A.Meyer) against radiation-induced MN in human PBLs after in vitro irradiation (3Gy) and in SLs of C57BL/6 mice after in vivo irradiation (3Gy). The frequency of MN in human PBLs was reduced by water fraction of ginseng (0.5mg/ml of medium) both pre-and post treatment (p<0.0l) in vitro. In addition, the frequency of MN in mouse SLs was also reduced by pretreatment of ginseng (2mg/ml of drinking water for 7days) in vivo. The data suggested that the ginseng may reduce cell damage caused by ${\gamma}$-rays in vitro and in vivo. Further studies are needed to characterize better the protective nature of ginseng extract, its fractions and compounds.

  • PDF

Evaluation of DNA Double Strand Breaks in Human and Mouse Lymphocyte Following ${\gamma}-Irradiation$ (${\gamma}-Ray$ 조사에 따른 사람의 정상임파구와 마우스 정상임파구의 DNA Double Strand Break 발생율에 대한 비교분석)

  • Kim Tae Hwan;Kim Sung Ho;Chung In Yong;Cho Chul Koo;Ko Kyung Hwan;Yoo Seong Yul
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.219-225
    • /
    • 1993
  • The evaluation of radiation-induced DNA double strand breaks (DSB) was made following irradiation of human lymphocytes, murine lymphocytes and EL-4 leukemia cells over a wide dose range of $^{60}Co\;{gamma}-rays.$ In lipopolysaccharide (LPS) or phytohemagglutinin (PHA)-stimulated murine lymphocytes, the slopes of the stand scission factor (SSF) revealed that lymphocytes with LPS increased DNA DSB formation by a factor of 1.432 (p<0.005). Furthermore, strand break production was relatively inefficient in the T lymphocytes compared to the B lymuhocytes. And EL-4 leukemia cells were found to form significantly more DNA DSB to a greater extent than normal lymphocytes (p<0.005). The in vitro studies of the intrinsic radiosensitivity between human lymphocytes and murine lymphocytes showed similar phasic kinetics. However, murine lymphocytes were lower in DNA DSB formation and higher in the relative radiation dose of 10 percent DNA strand breaks at 3.5 hours following ${gamma}-irradiation$ than human lymphocytes. Though it is difficult to interpret these results, these differences may be result from environmental and genetic factors. From our data, if complementary explanations for this difference will be proposed, the differences in the dose-effect relationship for the induction of DSB between humans and mice must be related to interspecies variations in the physiological condition of the peripheral blood in vitro and not to differences in the intrinsic radiation sensitivity of the lymphocytes. These results can be estimated on the basis of dose-effect correlation enabling the interpretation of clinical response and the radiobiological parameters of cytometrical assessment.

  • PDF

The Effect of Troglitazone on Thermal Sensitivity in Uterine Cervix Cancer Cells (자궁 경부암 세포에서 Troglitazone이 온열감수성에 미치는 영향)

  • Lee, Ji-Hye;Kim, Won-Dong;Yu, Jae-Ran;Park, Woo-Yoon
    • Radiation Oncology Journal
    • /
    • v.28 no.2
    • /
    • pp.91-98
    • /
    • 2010
  • Purpose: Troglitazone (TRO), a PPAR-$\gamma$ agonist, can reduce heat shock protein (HSP) 70 and increase the antioxidant enzymes, such as superoxide dismutase (SOD) and catalase, which might affect thermal sensitivity. Here, we investigated whether TRO modifies thermal sensitivity in uterine cervical cancer cells, which is most commonly treated by hyperthermia (HT). Materials and Methods: HeLa cells were treated with $5{\mu}M$ TRO for 24 hours before HT at $42^{\circ}C$ for 1 hour. Cell survival was analyzed by clonogenic assay. The expression of HSPs was analyzed by Western blot. SOD and catalase activity was measured and reactive oxygen species (ROS) was measured using 2',7'-dichlorofluorescin diacetate and dihydroethidium. Results: The decreased cell survival by HT was increased by preincubation with TRO before HT. Expression of HSP 70 was increased by HT however, it was not decreased by preincubation with TRO before HT. The decreased Bcl-2 expression by HT was increased by preincubation with TRO. SOD and catalase activity was increased by 1.2 and 1.3 times,respectively with TRO. Increased ROS by HT was decreased by preincubation with TRO. Conclusion: TRO decreases thermal sensitivity through increased SOD and catalase activity, as well as scavenging ROS in HeLa cells.

Optimization of Yonsei Single-Photon Emission Computed Tomography (YSECT) Detector for Fast Inspection of Spent Nuclear Fuel in Water Storage

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Kyunghoon Cho;Hakjae Lee;Yong Hyun Chung;Yeon Soo Yeom;Sei Hwan You;Hyun Joon Choi;Chul Hee Min
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.29-39
    • /
    • 2024
  • Background: The gamma emission tomography (GET) device has been reported a reliable technique to inspect partial defects within spent nuclear fuel (SNF) of pin-by-pin level. However, the existing GET devices have low accuracy owing to the high attenuation and scatter probability for SNF inspection condition. The purpose of this study is to design and optimize a Yonsei single-photon emission computed tomography version 2 (YSECT.v.2) for fast inspection of SNF in water storage by acquisition of high-quality tomographic images. Materials and Methods: Using Geant4 (Geant4 Collaboration) and DETECT-2000 (Glenn F. Knoll et al.) Monte Carlo simulation, the geometrical structure of the proposed device was determined and its performance was evaluated for the 137Cs source in water. In a Geant4-based assessment, proposed device was compared with the International Atomic Energy Agency (IAEA)-authenticated device for the quality of tomographic images obtained for 12 fuel sources in a 14 × 14 Westinghouse-type fuel assembly. Results and Discussion: According to the results, the length, slit width, and septal width of the collimator were determined to be 65, 2.1, and 1.5 mm, respectively, and the material and length of the trapezoidal-shaped scintillator were determined to be gadolinium aluminum gallium garnet and 45 mm, respectively. Based on the results of performance comparison between the YSECT.v.2 and IAEA's device, the proposed device showed 200 times higher performance in gamma-detection sensitivity and similar source discrimination probability. Conclusion: In this study, we optimally designed the GET device for improving the SNF inspection accuracy and evaluated its performance. Our results show that the YSECT.v.2 device could be employed for SNF inspection.

Comparison of the effects of gamma ray, electron beam, and X-ray irradiation to improve safety of black pepper powder (후춧가루의 위생화를 위한 감마선, 전자선 및 X-선 조사 효과 비교)

  • Park, Jae-Nam;Jung, Koo;Yoon, Young-Min;Choi, Soo-Jeong;Kim, Jae-Hun;Lee, Ju-Woon;Song, Beom-Seok
    • Food Science and Preservation
    • /
    • v.21 no.3
    • /
    • pp.315-320
    • /
    • 2014
  • This study evaluated the effects of a gamma ray (GR), electron beam (EB), and X-ray (XR) to improve the safety of black pepper powder. The black pepper powder was irradiated by GR, EB, and XR at 2, 4, 6, 8, and 10 kGy. The results of the total bacterial populations in the black pepper power sample showed a similar effect on microbial decontamination for radiation sources. Radiation sensitivity ($D_{10}$ value) on the initial bacteria loads in the sample was 2.24 kGy in GR, 2.37 kGy in EB, and 2.75 kGy in XR. In addition, there were no differences among the radiation sources. The color values, such as L (lightness), a (redness), and b (yellowness), were not changed significantly. The sensory characteristics of GR, EB, and XR irradiated black pepper powder were decreased when the radiation dose increased, but there was no significant changes among the radiation sources. The results can be applied to investigate the effects of radiation sources on the microbiological and sensory characteristics of black pepper powder.

Preliminary Study of Performance Evaluation of a Dual-mode Compton Camera by Using Geant4 (Geant4 몬테칼로 전산모사 툴킷을 이용한 이중모드 컴프턴 카메라 최적화 설계 및 성능평가)

  • Park, Jin Hyung;Seo, Hee;Kim, Seoung Hoon;Kim, Young Soo;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.191-196
    • /
    • 2012
  • A double-scattering type Compton camera which is appropriate to imaging a high-energy gamma source has been developed for nuclear material surveillance at Hanyang University. The double-scattering type Compton camera can provide high imaging resolution; however, it has disadvantage of relatively low imaging sensitivity than existing single-scattering type Compton camera. In this study, we introduce a novel concept of a dual-mode Compton camera which incorporates two different types of Compton camera, i.e., single- and double-scattering type. The dual-mode Compton camera can operate high-resolution mode and high-sensitivity mode in a single system. To maximize its performance, the geometrical configuration was optimized by using Geant4 Monte Carlo simulation toolkit. In terms of imaging sensitivity, high-sensitivity mode had higher sensitivity than high-resolution mode up to 100 times while high imaging resolution of the double-scattering Compton camera was maintained.

Conceptual Study of Brain Dedicated PET Improving Sensitivity

  • Shin, Han-Back;Choi, Yong;Huh, Yoonsuk;Jung, Jin Ho;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.236-240
    • /
    • 2016
  • The purpose of this study is to propose a novel high sensitivity neuro-PET design. The improvement of sensitivity in neuro-PET is important because it can reduce scan time and/or radiation dose. In this study, we proposed a novel PET detector design that combined conical shape detector with cylindrical one to obtain high sensitivity. The sensitivity as a function of the oblique angle and the ratio of the conical to cylindrical portion was estimated to optimize the design of brain PET using Monte Carlo simulation tool, GATE. An axial sensitivity and misplacement rate by penetration of ${\gamma}$ rays were also estimated to evaluate the performance of the proposed PET. The sensitivity was improved by 36% at the center of axial FOV. This value was similar to the calculated value. The misplacement rate of conical shaped PET was about 5% higher than the conventional PET. The results of this study demonstrated the conical detector proposed in this study could provide subsequent improvement in sensitivity which could allow to design high sensitivity PET for brain imaging.

Development of Electronic Personal Dosimeter with Hybrid Preamplifier using Semiconductor Detector (반도체 검출기를 이용한 Hybrid 전치증폭기형 전자식 개인선량계 개발)

  • Lee, B.J.;Kim, B.H.;Chang, S.Y.;Kim, J.S.;Rho, S.R.
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.51-57
    • /
    • 2002
  • An electronic personal dosimeter(EPD) with hybrid type preamplifier adopting a semiconductor detector as a radiation detector has been developed, manufactured and test-evaluated. The radiation detection characteristics of this EPD has been performance-tested by using a reference photon radiation field. After several test-irradiations to a $^{137}Cs$ gamma radiation source the radiation detection sensitivity of this EPD appeared to be $3.8\;cps/Gy{\cdot}h^{-1}$. The linearity of radiation response was kept within 8% of the dose equivalent ranges of $10{\mu}Sv{\sim}4Sv$ and the angular dependence was under less than 4% in angles of ${\pm}60^{\circ}$. It was confirmed that the energy response range was in $60{\sim}1,250keV$ given in the ISO standard. This EPD satisfied the international criteria for the EPD in the mechanical and the environmental performance test for 9 test categories according to IEC 61526.

Changes of Optically Stimulated Luminescence Dosimeter Sensitivity with High Dose (고선량에 대한 광자극발광선량계의 방사선 민감도 변화 연구)

  • Han, Su Chul;Kim, Kum Bae;Choi, Sang Hyoun;Park, Seungwoo;Jung, Haijo;Ji, Young Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.98-104
    • /
    • 2016
  • We investigated the effect of high dose on the sensitivity of optically stimulated luminance dosimeters (OSLDs) on Co-60 gamma rays and used a commercial OLSD (Landauer, Inc., Glenwood, IL). New OSLDs were chosen arbitrarily and were irradiated with 1 Gy repeatedly. We confirmed the change in the radiation sensitivity after repeated irradiation. The OSLD sensitivity increased up to 3% after irradiating for seven times and decreased continuously after the eighth time. It dropped by approximately 0.35 Gy per irradiation. Finally, after irradiating for 30 times, the OSLD sensitivity decreased by approximately 7%. When the OSLDs were irradiated 10 times with 1 Gy after their irradiation using a high dose of 15 Gy and 30 Gy, their sensitivity decreased by 6% and 12%, respectively, compared to that before high-dose irradiation. The change in the OSLD sensitivity with a high dose could be modeled by an exponential equation. We confirmed the radiation sensitivity variation caused by a high dose, and the irradiation history of dosimeters was considered to reuse OSLDs irradiated with a high dose.

Radio-sensitivity of Contaminated Pathogens in Marinated Beef Rib (Galbi) Treated with ${\gamma}-Irradiation$ and Its Sensory Properties (시판 양념갈비에 오염된 병원성 미생물의 감마선 감수성 및 감마선 조사된 갈비의 관능적 품질특성)

  • Lee, Na-Young;Cho, Cheo-Hoon;Kang, Ho-Jin;Kim, Dong-Soo;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.168-173
    • /
    • 2004
  • Radio-sensitivity of pathogens in commercial marinated beef ribs, Galbi, and effect of irradiation on microbiological safety and sensory properties of marinated beef rib were investigated. Commercial raw marinated beef ribs were highly contaminated by pathogenic microorganisms including Bacillus cereus, Salmonella typhimurium, Escherichia coli, and Staphylococcus aureus, ranged from $10^{3}\;to\;10^{4}\;CFU/g$. Gamma irradiation reduced pathogen count during storage. No viable cells of pathogens were observed in sample irradiated at 7.5 kGy except for Bacillus cereus. Radio-sensitivity of inoculated pathogens in marinated beef ribs and commercial one showed $D_{10}$ value of 0.54-0.60 and 2.15-2.98, respectively, In sensory evaluation irradiated sample showed highest color and overall acceptance among treatments (p<0.05). Results indicate low dose (2.5-5.0 kGy) irradiation is effective for ensuring safety of marinated beef ribs without decreasing sensory quality.