• Title/Summary/Keyword: gamma-radiation

Search Result 2,196, Processing Time 0.028 seconds

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

  • Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.181-189
    • /
    • 2017
  • The conventional delivery quality assurance (DQA) process for RapidArc (Varian Medical Systems, Palo Alto, USA), has the limitation that it measures and analyzes the dose in a phantom material and cannot analyze the dosimetric changes under the motional organ condition. In this study, a DQA method was designed to overcome the limitations of the conventional DQA process for internal target volume (ITV) based RapidArc. The dynamic DQA measurement device was designed with a moving phantom that can simulate variable target motions. The dose distribution in the real volume of the target and organ-at-risk (OAR)s were reconstructed using 3DVH with the ArcCHECK (SunNuclear, Melbourne, USA) measurement data under the dynamic condition. A total of 10 ITV-based RapidArc plans for liver-cancer patients were analyzed with the designed dynamic DQA process. The average pass rate of gamma evaluation was $81.55{\pm}9.48%$ when the DQA dose was measured in the respiratory moving condition of the patient. Appropriate method was applied to correct the effect of moving phantom structures in the dose calculation, and DVH data of the real volume of target and OARs were created with the recalculated dose by the 3DVH program. We confirmed the valid dose coverage of a real target volume in the ITV-based RapidArc. The variable difference of the DVH of the OARs showed that dose variation can occur differently according to the location, shape, size and motion range of the target. The DQA process devised in this study can effectively evaluate the DVH of the real volume of the target and OARs in a respiratory moving condition in addition to the simple verification of the accuracy of the treatment machine. This can be helpful to predict the prognosis of treatment by the accurate dose analysis in the real target and OARs.

Effect of Citrus Pectin Oligosaccharide Prepared by Irradiation on High Cholesterol Diet B6.KOR-ApoE Mice

  • Kang, Ho-Jin;Kwon, Joong-Ho;Ahn, Dong-Uk;Lee, Ju-Woon;Lee, Wan-Kyu;Jo, Cheo-Run
    • Food Science and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.884-888
    • /
    • 2009
  • Effect of citrus pectin oligosaccharides produced by irradiation was studied on the ability to improve lipid metabolism and hypercholesterolemia in mice fed high cholesterol diets. A total of 35 mice were divided into 5 groups and fed the following diets for 6 weeks: normal diet (C), 0.5% cholesterol (CH), 0.5% cholesterol+5% non-irradiated pectin (P), 0.5% cholesterol+5% irradiated pectin at 20 kGy (PIR), and 0.5% cholesterol+5% irradiated at 20 kGy and dialyzed (PIR-F). CH group had significantly higher serum triglycerides, total cholesterol, and low density lipoprotein (LDL)-cholesterol contents than pectin oligosaccharide-treated groups (p<0.05). Triglycerides and total cholesterol contents was the lowest in C and PIR-F and followed by PIR and P group, and CH group had significantly higher LDL-cholesterol. Serum high density lipoprotein (HDL)-cholesterol content in C group was not different from that in CH and P groups, but lower than that of PIR and PIR-F groups. These results suggest that pectin oligosaccharides produced by irradiation can reduce the levels of serum triglyceride, total cholesterol, and LDL-cholesterol in the blood of mice fed high-cholesterol diets and therefore, irradiation can be used as a tool to produce functional oligosaccharides from citrus pectin.

Study of the used deuterium absorption material disposal

  • Kim, Dong-Gyung;Kim, Myung-Chul;Lee, Bum-Sig;Lee, Sang-Gu
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.64-72
    • /
    • 2004
  • The dryer (ten per unit) are operating to remove tritium in PHWR(Pressurized Heavy Water Reactor). There are coming out heavy water adsorbent from operating the dryer (95 drums for ten year per unit) The amount of radioactivity of heavy water adsorbent almost exceed ninety times more than disposal limit-in-itself showed by The Ministry of Science and Technology. It has to be disposed whole radioactive waste products, however there are problems of increase at the expense of their permanent disposal. In this research, We have studied how to remove kinds of nuclear materials and amount of tritium with in heavy water adsorbent. As the result we could develop disposal equipment and apply it. D20 adsorbent have to contain below Gamma nuclide O.3Bq/g and tritium 100Bq/g "The Regulation for disposal of the radioactivity wastes" showed by The Ministry of Science and Technology. There fore. So as to remove amount of tritium and kinds of nuclear materials (DTO) we needed a equipment. Also we have studied how to remove effectively radioactivity with in Adsorbent. As cleaning heavy water adsorbent and drying on each condition (temperature for drying and hours for cleaning). Because there is something to return heavy water adsorbent by removing impurities within adsorbent when it is dried o high temperature. After operating, we have been applying this research to the way to dispose heavy water adsorbent. Through this we could reduce solid waste products and the expense of permanent disposal of radioactive waste products and also we could contribute nuclear power plant run safely. According to the result we could keep the best condition of radiation safety super vision and we could help people believe in safety with Radioactivity wastes control for harmony with Environment.

  • PDF

TID and SEGR Testing on MOSFET of DC/DC Power Buck Converter (DC/DC 강압컨버터용 MOSFET의 TID 및 SEGR 실험)

  • Lho, Young Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.981-987
    • /
    • 2014
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a MOSFET (metal-oxide semiconductor field effect transistor), a PWM-IC (pulse width modulation-integrated circuit) controller, inductor, capacitor, etc. It is shown that the variation of threshold voltage and the breakdown voltage in the electrical characteristics of MOSFET occurs by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 5 heavy ions make the gate of MOSFET broken in SEGR (Single Event Gate Rupture) testing. TID testing on MOSFET is accomplished up to the total dose of 40 krad, and the cross section($cm^2$) versus LET(MeV/mg/$cm^2$) in the MOSFET operation is studied at SEGR testing after implementation of the controller board.

Quality Evaluation and Physical Identification of Irradiated Dried Fruits (감마선 조사 건조과일의 품질평가 및 물리적 판별)

  • Jung, Jae-Hoon;Jung, Yoonmi;Jo, Deokjo;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.11
    • /
    • pp.1559-1564
    • /
    • 2012
  • Raisins (Thailand), dried mangos (Philippines), and dried figs (Iran) were gamma-irradiated (0~5 kGy), and their quality and detection characteristics were investigated. Microbiological characteristics were at safe levels when samples were irradiated at higher than 3 kGy. In color change after irradiation, dried mangoes were the most sensitive. Photostimulated luminescence (PSL) measurement was not applicable to dried fruits, showing negative or intermediate values for the irradiated samples. Thermoluminescence (TL) measurement was good for dried figs, exhibiting a glow curve in range of $150{\sim}200^{\circ}C$, where the signal intensity was dependent on the irradiation dose. Electron spin resonance (ESR) measurement was suitable for raisins and dried mangos, resulting in dose-dependent radiation-induced sugar radical signals.

Development of Dose Verification Method for In vivo Dosimetry in External Radiotherapy (방사선치료에서 투과선량을 이용한 체내선량 검증프로그램 개발)

  • Hwang, Ui-Jung;Baek, Tae Seong;Yoon, Myonggeun
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • The purpose of this study is to evaluate the developed dose verification program for in vivo dosimetry based on transit dose in radiotherapy. Five intensity modulated radiotherapy (IMRT) plans of lung cancer patients were used in the irradiation of a homogeneous solid water phantom and anthropomorphic phantom. Transit dose distribution was measured using electronic portal imaging device (EPID) and used for the calculation of in vivo dose in patient. The average passing rate compared with treatment planning system based on a gamma index with a 3% dose and a 3 mm distance-to-dose agreement tolerance limit was 95% for the in vivo dose with the homogeneous phantom, but was reduced to 81.8% for the in vivo dose with the anthropomorphic phantom. This feasibility study suggested that transit dose-based in vivo dosimetry can provide information about the actual dose delivery to patients in the treatment room.

A Convenient System for Film Dosimetry Using NIH-image Software

  • Kurooka, Masahiko;Koyama, Syuji;Obata, Yasunori;Homma, Mitsuhiko;Imai, Kuniharu;Tabushi, Katsuyoshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.260-262
    • /
    • 2002
  • An accurate measurement of dose distribution is indispensable to perform radiation therapy planning. A measurement technique using a radiographic film, which is called a film dosimetry, is widely used because it is easy to obtain a dose distribution with a good special resolution. In this study, we tried to develop an analyzing system for the film dosimetry using usual office automation equipments such as a personal computer and an image scanner. A film was sandwiched between two solid water phantom blocks (30 ${\times}$ 30 ${\times}$ 15cm). The film was exposed with Cobalt-60 ${\gamma}$-ray whose beam axis was parallel to the film surface. The density distribution on the exposed film was stored in a personal computer through an image scanner (8bits) and the film density was shown as the digital value with NIH-image software. Isodose curves were obtained from the relationship between the digital value and the absorbed dose calculated from percentage depth dose and absorbed dose at the reference point. The isodose curves were also obtained using an Isodose plotter, for reference. The measurements were carried out for 31cGy (exposure time: 120seconds) and 80cGy (exposure time: 300seconds) at the reference point. While the isodose curves obtained with our system were drawn up to 60% dose range for the case of 80cGy, the isodose curves could be drawn up to 80% dose range for the case of 31cGy. Furthermore, the isodose curves almost agreed with that obtained with the isodose plotter in low dose range. However, further improvement of our system is necessary in high dose range.

  • PDF

Radiolysis of Oxygenated and Deoxygenated Glycylglycylglycine in Aqueous Solution and in the Solid State (酸素의 存在下와 無酸素下에서의 水溶液 및 固體 Glycylglycylglycine의 放射線分解)

  • Kang, Man-Sik
    • The Korean Journal of Zoology
    • /
    • v.13 no.3
    • /
    • pp.75-84
    • /
    • 1970
  • Gamma-radiolyses of oxygenated and deoxygenated glycylglycylclycine in aqueous solution and in the solid state are observed, with special regards to peptied bond rupture for elucidation of radiolytic mechanism of proteins, by means of chromatorgraphic separation of degradation products, spectrophotometric quantitation of carbonyl compounds, micro-titration of amide formation, infrared spectrophptometry, and ultraviolet spectrophotometry for evaluation of radiation damage. Essential difference of peptide bond rupture is observed in solution and in the solid state, being high in the former and negligible in the latter. On the other hand, the presence of and obsence of oxygen in solution during irradiation are not so significant with respect to peptide bond rupture, except the recombination of free-radicals produced in deoxygenated solution. Peptide bond rupture in solution is attributable to the mechanisms proposed by Garrison et al.; dehydrogenation followed by hydrolysis to yield acid amide and carbonyl function as found on the basis of radiolytic products. Peptide bond attack at $\\alpha$-carbon locus might be suggestive for irradiated solid but not significant in view of low degree of peptide bond rupture.

  • PDF

RTD Analysis using Radioisotope Tracer on the Water Flow Characteristics in a Flocculator of Wastewater Treatment Facility (방사성동위원소 추적자를 이용한 폐수처리시설의 응집조에서 유입수의 체류시간분포 분석)

  • Kim, Jin-Seop;Jung, Sung-Hee;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Using In-113m emitting gamma ray of 0.392MeV at radioisotope tracer the RTD (residence time distribution) of water in the flocculator of wastewater treatment facility was measured. The result was analyzed mathematically using K-RTD program constructed on the basis of CFSTR (constant flow stirred tank reactor) model. The mean residence time and the tank number are the main parameters which describe the flow behavior of the system. Those parameters were obtained in the fitting profess of the simulated curves to the experimental results. It was suggested to construct a modified numerical model to describe the bypass flow which was observed in the experiment.

Microbiological and chemical changes in the Pacific oysters, Crassostrea gigas exposed to gamma radiation during ice storage (감마선 조사된 참굴의 빙장 기간중의 세균학 및 화학적 변화)

  • CHUNG Jong Rak
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.7 no.4
    • /
    • pp.221-228
    • /
    • 1974
  • 산란직전의 남해산 참굴(Crassostrea gigas)을 산채로 구입하여 통상조건하에서 탈각하여 얻은 굴육질을 polyethylene laminated aluminium pouch (Al+PE : 0.03+0.03mm) 속에 밀봉하여 살균선량(0.2Mrad) 및 멸균선량(2.0Mrad)의 감마선으조 조사하고, 한편, 100ppm의 염소수에 굴육질을 2분간 침지한 후 탈수하여 같은 방법으로 포장하여 35일간의 빙장기간중 세균학적 및 화학적 변화를 대조 굴(조사치 않고 염소수 처리하지 않은)의 경우와 비교하였다. 굴육질의 시초의 총균수는 g당 700-800에 달했고, 0.2 Mrad의 감마선 조사는 빙장 10일째의 저장 기간중의 총 균수를 검측할 수 있는 선 이하로 감소시켰으며 2.0 Mrad 조사는 20일째까지 거의 무균상태를 가져왔다. 감마선 조사는 또한 세균활동을 표시하는 대사물질인 TMA와 TCA soluble nitrogen의 축적을 현저히 억제시켰으며 빙장 후기부터 번식하기 시작하여 총균수가 g당 100,000을 초과케 된 35일째까지도 대조굴의 동일한 총균수 시기에 비하여 이 대사물의 축적억제가 현저했음은 감마선 조사의 효과가 총균수의 양적인 감소뿐만 아니라 동시에 TMA를 생산하고 단백질을 분해할 능력이 있는 세균제거 내지는 번식의 억제라는 선택적인 양면을 가지고 있음을 보여 준다. 염소수 처리한 굴육질의 경우 총균수의 양적인 감소효과는 현저하지 않했는데도 불구하고 감마선 조사 경우처럼 세균대사물질 축적의 철저한 억제를 가져 왔음은 주목할만 하다. 굴육질의 glycogen 함량은 사후 저장 기간 중 쉽사리 감소되지 않했으며 PH 측정으로 본 생굴의 신선도와의 관련성은 희박하며 조사와 염소수 처리굴의 경우 더욱 그러했다.

  • PDF