• Title/Summary/Keyword: gamma spectra

Search Result 259, Processing Time 0.023 seconds

Radioisotope identification using sparse representation with dictionary learning approach for an environmental radiation monitoring system

  • Kim, Junhyeok;Lee, Daehee;Kim, Jinhwan;Kim, Giyoon;Hwang, Jisung;Kim, Wonku;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.1037-1048
    • /
    • 2022
  • A radioactive isotope identification algorithm is a prerequisite for a low-resolution scintillation detector applied to an unmanned radiation monitoring system. In this paper, a sparse representation with dictionary learning approach is proposed and applied to plastic gamma-ray spectra. Label-consistent K-SVD was used to learn a discriminative dictionary for the spectra corresponding to a mixture of four isotopes (133Ba, 22Na, 137Cs, and 60Co). A Monte Carlo simulation was employed to produce the simulated data as learning samples. Experimental measurement was conducted to obtain practical spectra. After determining the hyper parameters, two dictionaries tailored to the learning samples were tested by varying with the source position and the measurement time. They achieved average accuracies of 97.6% and 98.0% for all testing spectra. The average accuracy of each dictionary was above 96% for spectra measured over 2 s. They also showed acceptable performance when the spectra were artificially shifted. Thus, the proposed method could be useful for identifying radioisotopes in gamma-ray spectra from a plastic scintillation detector even when a dictionary is adapted to only simulated data. Furthermore, owing to the outstanding properties of sparse representation, the proposed approach can easily be built into an insitu monitoring system.

Conformation and Biological Activity of the Neuropeptide $\gamma$ (Neuropeptide $\gamma$의 구조 및 생리활성)

  • Ku Hee-Jung;SEO Jung-Kil;KIM Eun-Hi;HUH Min-Do;CHUNG Joon-Ki;PARK Jang-Su;KANG Shin-Won;PARK Nam Gyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.2
    • /
    • pp.244-251
    • /
    • 1997
  • The relationship between structure and biological activity was studied on the three neuropeptides (mammalian, trout- and goldfish-neuropeptide $\gamma$) that were syntheized by the solid-phase method. Circular dichroism spectra showed that mammalian, trout- and goldfish-neuropeptide $\gamma$ adopted an unordered structure in buffer solution. In the-presence of neutral and acidic liposomes, mammalian and trout-neuropeptioe $\gamma$ also took a random structure. However, goldfish-neuropeptide $\gamma$ took an $\alpha-helical$ structure in acidic liposomes. The intestinal motility response was investigated with carp intestines, guinea-pig ileums and rat duodenums. In case of carp intestine, contractile activity was as follows : goldfish-neuropeptide $\gamma\simeq$ trout-neuropeptide $\gamma>$ mammalian-neuropeptide $\gamma$, On the other hand, the contractile activity of mammalian-neuropeptide $\gamma$ was more potent than trout- and goldfish-neuropeptide $\gamma$ in the guinea-pig ileums and rat duodenums. These results suggest that neuropeptide $\gamma$ show the species-specific activity.

  • PDF

A Comparison Method of Silver Nanoparticles Prepared by the Gamma Irradiation and in situ Reduction Methods

  • Lee, Chul-Jae;Karim, Mohammad Rezaul;Vasudevan, T.;Kim, Hee-Jin;Raushan, K.;Jung, Maeng-Joon;Kim, Dong-Yeub;Lee, Mu-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1993-1996
    • /
    • 2010
  • Silver nanoparticles has been prepared by the $\gamma$-irradiation and in situ reduction methods. Based on the Raman spectra, TEM images, X-ray Diffraction (XRD) patterns and UV-vis spectra, the in situ reduction method is more stable and the average size of the silver nanoparticles is also smaller than by the $\gamma$-irradiation reduction method. It is identified that the silver ions interacting with nonbonding electrons of oxygen atom in the carbonyl group of polyvinylpyrrolidone (PVP) by the in situ reduction method. It is also found advantages of the in situ reduction method including no additional reducing agents, without $\gamma$-irradiations treatment and the room temperature treatment suitability.

Scaling law in MHD turbulence small-scale dynamo

  • Park, Kiwan;Ryu, Dongsu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.74.2-74.2
    • /
    • 2014
  • Magnetohydrodynamics(MHD) dynamo depends on many factors such as viscosity ${\gamma}$, magnetic diffusivity ${\eta}$, magnetic Reynolds number $Re_M$, external driving source, or magnetic Prandtl number $Pr_M$. $Pr_M$, the ratio of ${\gamma}$ to ${\eta}$ (for example, galaxy ${\sim}10^{14}$), plays an important role in small scale dynamo. With the high PrM, conductivity effect becomes very important in small scale regime between the viscous scale ($k_{\gamma}{\sim}Re^{3/4}k_fk_f$:forcing scale) and resistivity scale ($k_{\eta}{\sim}PrM^{1/2}k_{\gamma}$). Since ${\eta}$ is very small, the balance of local energy transport due to the advection term and nonlocal energy transfer decides the magnetic energy spectra. Beyond the viscous scale, the stretched magnetic field (magnetic tension in Lorentz force) transfers the magnetic energy, which is originally from the kinetic energy, back to the kinetic eddies leading to the extension of the viscous scale. This repeated process eventually decides the energy spectrum of the coupled momentum and magnetic induction equation. However, the evolving profile does not follow Kolmogorov's -3/5 law. The spectra of EV (${\sim}k^{-4}$) and EM (${\sim}k^0$ or $k^{-1}$) in high $Pr_M$ have been reported, but our recent simulation results show a little different scaling law ($E_V{\sim}k^{-3}-k^{-4}$, $EM{\sim}k^{-1/2}-k^{-1}$). We show the results and explain the reason.

  • PDF

A Study on the Characteristics of TSC for BOPP Irradiatied by $Co^{60}-{\gamma}$ ray ($Co^{60}-{\gamma}$ 선으로 조사된 이축 연신된 폴리프로필렌 필름의 열자격 특성에 관한 연구)

  • Song, K.Y.;Park, S.H.;Ryu, B.H.;Hong, J.W.;Lee, J.U.;Kim, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.195-198
    • /
    • 1990
  • In order to investigate the radiation effects induced to electrical properties of Biaxially-Oriented Polypropylen film, several observations were carried out to the sample irradiated to various dose by $Co^{60}-{\gamma}$ ray, on the characteristics of TSC spectra measuered as a function of electric field applied to a sample of 15[ ${\mu}m$] thick. The TSC spectra observed in the temperature range of $153{\sim}403[K]$ with the electric field of intensity $10{\sim}60$ [MV/m], have shown two of the distinguished peak such as ${\beta}$, ${\alpha}$, each of which appeared at $-5{\sim}20$ [ $^{\circ}C$] and 90 [ $^{\circ}C$] respectively. As the conclusions, obtained from the studies, the origin of ${\alpha}$ peak in TSC seems to be attributed by thermal excitation of ions trapped with $0.4{\sim}0.8[eV]$ deep, at the defects formed by $Co^{60}-{\gamma}$ irradiation in a crystaline region. The origin of ${\beta}$ peak was regarded as the depolarization process of "OH" or "CO" dipole with the activation energy of $0.4{\sim}0.6[eV]$ in an amorphous region.

  • PDF

Diagnostics of Diffuse Two-Phase Matter Using Techniques of Positron Annihilation Spectroscopy in Gamma-Ray and Optical Spectra

  • Doikov, Dmytry;Yushchenko, Alexander;Jeong, Yeuncheol
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.3
    • /
    • pp.115-119
    • /
    • 2019
  • This paper is a part of the series on positron annihilation spectroscopy of two-phase diffuse gas-and-dust aggregates, such as interstellar medium and the young remnants of type II supernovae. The results obtained from prior studies were applied here to detect the relationship between the processes of the annihilation of the K-shell electrons and incident positrons, and the effects of these processes on the optical spectra of their respective atoms. Particular attention was paid to the Doppler broadening of their optical lines. The relationship between the atomic mass of the elements and the Doppler broadening, ${\Delta}{\lambda}_D$ (${\AA}$), of their emission lines as produced in these processes was established. This relationship is also illustrated for isotope sets of light elements, namely $^3_2He$, $^6_3Li$, $^7_3Be$, $^{10}_5B$ and $^{11}_5B$. A direct correlation between the ${\gamma}-line$ luminosity ( $E_{\gamma}=1.022MeV$) and ${\Delta}{\lambda}_D$ (${\AA}$) was proved virtually. Qualitative estimates of the structure of such lines depending on the positron velocity distribution function, f(E), were made. The results are presented in tabular form and can be used to set up the objectives of further studies on active galactic nuclei and young remnants of type II supernovae.

Positional correction of a 3D position-sensitive virtual Frisch-grid CZT detector for gamma spectroscopy and imaging based on a theoretical assumption

  • Younghak Kim ;Kichang Shin ;Aleksey Bolotnikov;Wonho Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1718-1733
    • /
    • 2023
  • The virtual Frisch-grid method for room-temperature radiation detectors has been widely used because of its simplicity and high performance. Recently, side electrodes were separately attached to each surface of the detectors instead of covering the entire detector surface with a single electrode. The side-electrode structure enables the measurement of the three-dimensional (3D) gamma-ray interaction in the detector. The positional information of the interaction can then be utilized to precisely calibrate the response of the detector for gamma-ray spectroscopy and imaging. In this study, we developed a 3D position-sensitive 5 × 5 × 12 mm3 cadmium-zinc-telluride (CZT) detector and applied a flattening method to correct detector responses. Collimated gamma-rays incident on the surface of the detector were scanned to evaluate the positional accuracy of the detection system. Positional distributions of the radiation interactions with the detector were imaged for quantitative and qualitative evaluation. The energy spectra of various radioisotopes were measured and improved by the detector response calibration according to the calculated positional information. The energy spectra ranged from 59.5 keV (emitted by 241Am) to 1332 keV (emitted by 60Co). The best energy resolution was 1.06% at 662 keV when the CZT detector was voxelized to 20 × 20 × 10.

Radionuclide identification method for NaI low-count gamma-ray spectra using artificial neural network

  • Qi, Sheng;Wang, Shanqiang;Chen, Ye;Zhang, Kun;Ai, Xianyun;Li, Jinglun;Fan, Haijun;Zhao, Hui
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.269-274
    • /
    • 2022
  • An artificial neural network (ANN) that identifies radionuclides from low-count gamma spectra of a NaI scintillator is proposed. The ANN was trained and tested using simulated spectra. 14 target nuclides were considered corresponding to the requisite radionuclide library of a radionuclide identification device mentioned in IEC 62327-2017. The network shows an average identification accuracy of 98.63% on the validation dataset, with the gross counts in each spectrum Nc = 100~10000 and the signal to noise ratio SNR = 0.05-1. Most of the false predictions come from nuclides with low branching ratio and/or similar decay energies. If the Nc>1000 and SNR>0.3, which is defined as the minimum identifiable condition, the averaged identification accuracy is 99.87%. Even when the source and the detector are covered with lead bricks and the response function of the detector thus varies, the ANN which was trained using non-shielding spectra still shows high accuracy as long as the minimum identifiable condition is satisfied. Among all the considered nuclides, only the identification accuracy of 235U is seriously affected by the shielding. Identification of other nuclides shows high accuracy even the shielding condition is changed, which indicates that the ANN has good generalization performance.

A Copper Shield for the Reduction of X-γ True Coincidence Summing in Gamma-ray Spectrometry

  • Byun, Jong-In
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.137-142
    • /
    • 2018
  • Background: Gamma-ray detectors having a thin window of a material with low atomic number can increase the true coincidence summing effects for radionuclides emitting X-rays or gamma-rays. This effect can make efficiency calibration or spectrum analysis more complicated. In this study, a Cu shield was tested as an X-ray filter to neglect the true coincidence summing effect by X-rays and gamma-rays in gamma-ray spectrometry, in order to simplify gamma-ray energy spectrum analysis. Materials and Methods: A Cu shield was designed and applied to an n-type high-purity germanium detector having an $X-{\gamma}$ summing effect during efficiency calibration. This was tested using a commercial, certified mixed gamma-ray source. The feasibility of a Cu shield was evaluated by comparing efficiency calibration results with and without the shield. Results and Discussion: In this study, the thickness of a Cu shield needed to avoid true coincidence summing effects due to $X-{\gamma}$ was tested and determined to be 1 mm, considering the detection efficiency desired for higher energy. As a result, the accuracy of the detection efficiency calibration was improved by more than 13% by reducing $X-{\gamma}$ summing. Conclusion: The $X-{\gamma}$ summing effect should be considered, along with ${\gamma}-{\gamma}$ summing, when a detection efficiency calibration is implemented and appropriate shielding material can be useful for simplifying analysis of the gamma-ray energy spectra.

Interaction between Omeprazole and $\gamma$-Cyclodextrin (오메프라졸과 $\gamma$-시클로덱스티린과의 복합체 형성 및 제제학적 특성)

  • 이계주;김은영
    • YAKHAK HOEJI
    • /
    • v.39 no.2
    • /
    • pp.175-184
    • /
    • 1995
  • The interaction of omeprazole(OMP) with $\gamma$-cyclodextrin($\gamma$-CyD) was investigated by solubility study and the complexation was confirmed by means of UV/VIS spectrophotometer, circular dichroism, differential scanning calorimeter, and $^{1}$H nuclear magnetic resonance spectra. The stability, dissolution rate, and partition coefficient of the complex were measured. The results present that the benzimidazole moiety and a part of pyridine ring containing sulfur atom of OMP might be included into the cavity of $\gamma$-CyD and the formation type of inclusion complex appeared to be B$_{s}$. The stoichiometric ratio of OMP to $\gamma$-CyD in the complex was found to be 1:1 and the stability constant of the complex found to be 97.1 M$^{-1}$. And the dissolution rate of OMP was markedly increased by inclusion complex formation with $\gamma$-CyD, and so it was above 90% in 5 min. from solid complex. Oil to water partition coefficient of OMP-$\gamma$-CyD complex was 60, which is significantly higher than that of OMP itself, 36.4. The degradation rate constant of OMP were greater than OMP-$\gamma$-CyD complex in aqueous solutions of various pHs, and the half lives of OMP and OMP-$\gamma$-CyD at pH 9 were 279.2 and 509.9 days, respectively, showing that the complex was more stable than OMP, therefore it was thought that OMP was stabilized by inclusion formation with $\gamma$-CyD.

  • PDF