Charactristice of a colored Galvanized Coating using Ti-Zn Alloy System (Zn-Ti계용융아연 도금강판의 착색화 특성)

  • 전선호
    • Journal of the Korean institute of surface engineering
    • /
    • v.30 no.5
    • /
    • pp.320-332
    • /
    • 1997
  • The development of colored surface on zinc coating by the oxidation of a melten alloy of zinc with a minor amount of oxygen-avid additive such as tianium has been studied. Using a galvanizing Zinc alloy containing 0.1 to 0.3wt%Ti, gold, purple or blue color was developed clearly and stably, depending upon the extent of oxidation, by air cooling after hot dipping in a bath at temperature of $550^{\circ}C$ to $600^{\circ}C$. The source of the color is light interference with surface oxide layer. THe final color depends on the thickness of the color depends on the thickness of $TiO_2$, played So compositing, temperature and time at elevated temperature after are all controlling variables. Since oxidation film such as $TiO_2$ played role of passivation film, the corrosion resistance in a colored galvanized steel sheet. It is also thought that surface oxide layer of $TiO_2$ inhibited dissolution of the coating layer.

  • PDF

A Study on Elliptical Cup Drawing of Yoke products, Automobile (자동차 TOKE 제품의 타원용기 성형에 관한 연구)

  • 박동환;배원락;박상봉;강성수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.385-388
    • /
    • 2000
  • During the deep drawing process an initially flat blank is clamped between the die and the blank holder after which the punch moves down to deform the clamped blank into the desired shape. In general, sheet metal forming may involve stretching, drawing, bending or various combinations of those basic modes of deformation. The deformation problems of sheet metal working involve non-linearity in geometry and material. In this work, The punch load and thickness strain of electro-galvanized sheet steel (SECD) for elliptical deep drawing are examined under the various process conditions including, punch shape radius, die shape radius. The changes of punch load and thickness strain distribution of the deformed elliptical cup are affected by the size of each die shape radius.

  • PDF

Structural Performance of Trussed Bar Deck Plates of Metal Lath with Mortar (모르터와 메탈라스로 제작된 트러스형 테크플레이트의 구조적 성능)

  • Seo, Dong-Min;Kim, Sung-Bae;Lee, Chang-Nam;Kim, Sang-Seup;Hong, Sung-Gul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.41-44
    • /
    • 2006
  • Increase in use of deck plates is accelerated by a manpower shortage and the high cost of construction. Some of problems including fire resistance, waterproof, and low corrosion can be solved by development of new deck plates. This paper evaluates the structural performance of the LAMO Deck which metal laths instead of galvanized steel sheet is covered by mortar.

  • PDF

Paradigm Shift of Global Market and Pattern of Technology Innovation for Automotive Steel Sheets (자동차용 강판시장의 글로벌 패러다임 변화 및 기술혁신 패턴)

  • Jung, Kyung-Hee
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.4
    • /
    • pp.476-489
    • /
    • 1999
  • This paper is concerned with the deployment of core technologies for automotive steel sheets, based on the structural change of global market. The main tasks of automotive industry are to ensure the energy consumption, environmental regulations, and driving safety. With social and legal requirements, this study analyzes the market creation processes with technological innovations for hot rolled, cold rolled and galvanized steel sheets during the 20th century. It has been proven that the leading country in the steel industry was also that in the automotive. The purchaser-supplier relations of sheet materials are then patternized in the regional markets of the United States and Japan, who share nearly 50% of market in the world. According to the paradigm shift of globalization, the balance of power in Porter's 5 forces has been moved to the buyers', and both industries pursue Win-Win strategies such as the PNGV(Partnership for a New Generation of Vehicles ) and design-in system with the competition.

  • PDF

Behavior of Hybrid Stud under Compressive Load (복합스터드의 압축 좌굴 거동)

  • Lee, Sang Sup;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.609-619
    • /
    • 2004
  • An investigation was conducted on the activities around Europe in order to solve the problem of the thermal bridging of steel studs, which had caused a significant disadvantage. This study included the following: diminishing the contact area between the studs and the sheathing, lengthening the heat transfer route, replacing the steel web with a less conductive material, and placing foam insulation in locations where the thermal shorts are most critical. Although energy efficiency is usually the focus of such foreign cases because their stud application is mostly limited to low-rise residential buildings, both structural and thermal performance are taken into consideration in this study because these target middle-story buildings. A hybrid stud composed of steel and polymer was also developed. This hybrid stud, which is 150 SL in size, is made of a galvanized steel sheet (SGC58) and a glass fiber reinforced polymer (GFRP) withepoxy bonding. A total of 32 specimens were manufactured. Its parameters comprise two types of connection detail,s: the thickness of steel (1.0mm and 1.2mm) and of the GFRP (4mm-4ply and 6mm-6ply), and the ratio of the length to the depth (L/D = 3, 6, 9, 12). Steel stud specimens with the same conditions were compared to the hybrid stud. The test revealed that in the case of the steel specimen with a thickness of 1.0mm, the maximum load of hybrid studs increased an average of 1.62 times comparedto that of the steel stud. In the case of the steel specimen with a thickness of 1.2mm, on the other hand, the average increase was 1.46times. All specimens showed full composite action until the collapse.

Effects of Electrostatic Force on Movement of Sprayed Aerosol Particles in Continuous Galvanizing Process (용융도금강판의 제조 공정에 있어서 2-유체 분사 액적의 운동에 미치는 정전대전력의 영향)

  • Kim, S.H.;Kim, H.M.;Chung, H.C.;Chung, W.S.
    • Journal of ILASS-Korea
    • /
    • v.5 no.3
    • /
    • pp.45-54
    • /
    • 2000
  • A novel electrostatic splaying method for solidifying a galvanized coating layer was studied. Our experimental results and computer simulations showed that electric field could assist the fine droplets to attach on the steel surface and change the sprayed droplets trajectory especially in the space near the steel surface. It was necessary to apply the electric voltage higher than - 20 kV to obtain the enough electrostatic attraction force between droplets and the steel sheet.

  • PDF

Effects of Antimony and Lead in Galvanizing Bath on Spangle Formation in Galvanized Steel Sheet Coatings (용융아연도금강판의 스팡글 형성에 미치는 도금욕 중 안티몬 및 납의 영향)

  • 김상헌;김형민;정원섭;전선호
    • Journal of the Korean institute of surface engineering
    • /
    • v.33 no.5
    • /
    • pp.387-397
    • /
    • 2000
  • Antimony in the galvanizing bath had greater effect on the growth of grains in the solidification of molten coating layer and on the decrease of its surface roughness than lead. Particularly 0.01 wt % antimony in the galvanizing bath showed much stronger effect than expected considering its low surface tension value. These effects were seemingly originated from the development of preferred orientation of (0002) plane parallel to steel surface. Antimony was found to be widely distributed in form of orderly arrangement throughout the coating layer unlike lead from the results of surface analyses on coating layers as received and on those as etched in chromating solution. In addition, supercooling in the 0.07 % antimony and the 0.2 % lead galvanizing bath was also measured to be in the range of$ 2~4^{\circ}C$ and $9~11^{\circ}C$ respectively, and it indicates that antimony forms fine dendrite expanded rapidly on the steel surface.

  • PDF

A comparative study of constant current control and adaptive control on electrode life time for resistance spot welding of galvanized steels (용융아연도금 강판 저항 점 용접 시 정전류 및 적응제어 적용에 따른 연속타점 특성 평가 및 고찰)

  • Seo, Jeong-Chul;Choi, Il-Dong;Son, Hong-Rea;Ji, Changwook;Kim, Chiho;Suh, Sung-Bu;Seo, Jinseok;Park, Yeong-Do
    • Journal of Welding and Joining
    • /
    • v.33 no.2
    • /
    • pp.47-55
    • /
    • 2015
  • With using adaptive control of the resistance spot welding machine, the advantage on electrode life time for galvanized steels has been addressed. This study was aimed to evaluate the electrode life time of galvanized steels with applying the constant current control and the adaptive control resistance spot welding process for a comparison purpose. The growth in diameter of electrode face was similar for both the constant current and the adaptive control up to 2000 welds. The button diameter was decreased with weld numbers, however, sudden increase in button diameter with use of the adaptive control after 1500 welds was observed. The peak load was continuously decreased with increasing number of welds for both the constant current and the adaptive control. The current compensation during a weld was observed with using the adaptive control after 1800 welds since the ${\beta}$-peak on dynamic resistance curve was detected at later weld time. The current compensation with adaptive control during resistance spot welding enhanced the nugget diameter at the faying interface of steel sheets and improved the penetration to thinner steel sheet.

Development of Thermal Properties on the Roof Waterproof with Insulation System using the Diffused Reflection Material (확산반사를 이용한 경질시트 옥상 단열방수공법의 열성능 개선에 관한 연구)

  • Koo, Jae-Oh
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.73-80
    • /
    • 2007
  • This paper aims to develop the diffused reflection material in order to reduce the solar absorption coefficient, and to compare the thermal properties with the different roof structure system; one is using the diffused reflection material applied the upper side of the rigid sheet waterproof system and the other is using the conventional up-side down waterproof system on the roof. For this purpose two experimental test boxes were made of same iso-panel wall and floor with different roof system. The experiment was carried out under these process; measure the surface temperature exposed solar radiation of the variation of the reflection materials(cement paste, silica, galvanized steel and titanium dioxide(TiO2)), measure and analyze the variation of the temperature distribution of the each roof system and indoor air in order to evaluate the thermal properties according to the different roof system. The result shows clearly that using the titanium dioxide(TiO2) might be more effective to reduce the solar insolation.

A Study on the Structural Performance of Hybrid Studs Subjected to Compression and Torsion (압축과 비틂을 동시에 받는 복합스터드의 구조적 성능에 관한 연구)

  • Jung, Yun Jin;Kwon, Young Bong;Kwak, Myong Keun;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.543-551
    • /
    • 2006
  • Cold-formed steel studs that are being used as load-bearing members of wall panels for steel houses have a problem with their insulation due to the heat bridging of their web. Some additional thermal insulating materials should be used. To solve this problem, the new-concept hybrid stud, which consists of a galvanized steel sheet (t = 1.0 m - 12.0 m) and a GFRP panel (t = 4.0-6.0 mm), has recently been developed. An investigation on the structural behavior and the strength capacity of this new hybrid stud has been conducted so that it can be used in load-bearing wall panels of residential buildings. This paper describes the axial compression-torsion test results of the hybrid studs under both axial compression and torsion using ATTM. The main factors of the test were the stud length, the magnitude of the initial compressive force, and the loading method of the monotonic or cyclic loading. The torsion was applied increasingly while the initial compression was kept constant to the failure of the hybrid section. The advanced analysis results obtained form the finite element procedure that considered the material properties of the high-strength galvanized steel and the GFRP were compared with the test results for verification.