• Title/Summary/Keyword: fundamental solution.

Search Result 737, Processing Time 0.02 seconds

Nonlinear Finite Element-Boundary Element Analysis of Multi-Layered Structural Systems (유한요소와 경계요소의 조합에 의한 다층 구조계의 비선형 해석)

  • 김문겸;허택녕;이상도
    • Computational Structural Engineering
    • /
    • v.7 no.4
    • /
    • pp.57-67
    • /
    • 1994
  • It is usual that underground structures are constructed within a multi-layered medium. In this paper, an efficient numerical modelling of multi-layered structural systems is studied using coupled analysis of finite elements and boundary elements. The finite elements are applied to the area in which the material nonlinearity dominates, and the boundary elements are applied to the far field where the nonlinearity is relatively weak. In the boundary element modelling of the multi-layered medium, fundamental solutions are not readily available. Thus, methods which can utilize existing Kelvin solutions are sought for the interior multi-layered domain problem. The interior domain problem which has piecewise homogeneous layers is analyzed using boundary elements with Kelvin solution, by discretizing each homogeneous subdomain and enforcing compatibility and equilibrium conditions between interfaces. Developed methodology is verified by comparing its results with those from the finite element analysis and it is concluded that coupled analysis using boundary elements and finite elements can be reasonable and efficient.

  • PDF

A Fundamental Study of Structure-Property Relationships in $Eu^{3+}$ Luminescence ($Eu^{3+}$ 이온의 발광성에 대한 구조와 성질의 기본적인 연구)

  • Chang, Ki-Seog
    • Korean Journal of Crystallography
    • /
    • v.13 no.1
    • /
    • pp.25-30
    • /
    • 2002
  • The M/sub 1-x/Na/sub 2x/Al₂(BO₃)₂O (M = Ca and Sr) solid solution systems have been shown interstitial solid solutions and continuous substitutional solid solutions. The symmetry around the Eu site of yEu/sup 3+/ : M/sub 1-x/Na/sub 2x/Al/sub 2-y/Mg/sub /(BO₃)₂O (M = Ca and Sr) changes the intensities and the chromaticities of transitions. The Eu/sup 3+/ion can be very bright and efficient and have the desired emission wave-length depending on the site symmetry of the Eu/sup 3+/ion site. As the amount of Na in the Eu/sup 3+/ion doped Ca/sub 1-x/Na/sub 2x/Al₂(BO₃)₂O system increases, the Eu site symmetry is going to be a noncentrosymmetric site. With increasing x, the decreased intensity in the /sup 5/D/sub 0/→/sup 7/F₁(590 nm) transition relates to the low symmetry of the Eus/up 3+/-doped Ca/sub 1-x/Na/sub 2x/Al₂(BO₃)₂O system, because of the Ca-centered octahedron in the CaAl₂(BO₃)₂O compound. The SrAl₂(BO₃)₂O compound also provides an improved chromaticity due to the lower site symmetry of Eu/sup 3+/ion.

Biodegradable PLGA Polymer Coating on Biomedical Metal Implants Using Electrospraying (전기분사를 이용한 의료용 금속 임플란트의 생분해성 PLGA 고분자 코팅)

  • Cho, Seong-Bae;Park, Chul-Ho;Park, Kwi-Deok;Chung, Dong-Jun;Han, Dong-Keun
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.620-624
    • /
    • 2009
  • Biomedical metal implants have been used clinically for replacement, restoration, or improvement of injury bodies based on high mechanical properties, but it has some risks such as the inflammatory, late thrombosis, or restenosis due to the low biocompatibility and toxicity. In various techniques of surface treatment developed to preserve these drawbacks, this study examined the electrospray coating technology with biodegradable poly (lactic-co-glycoic acid) (PLGA) on metal surface. Based on fundamental examination of electrospraying and solution parameters, the surface morphology of coated film was closely related to the boiling point of solvent, in-flight distance, and droplet size. The thickness of polymer film was linearly proportional to the emerged volume. This result exhibits that the polymeric droplets were continuously deposited on the polymer film. Therefore, the electrospray coating technology might be applied into the fabrication of single/multi-layered polymer film in nano-/micro-thickness and the control of the topology for biomedical metal implants including stents.

Development and Verification of Inundation Modeling with Urban Flooding Caused by the Surcharge of Storm Sewers (도시배수체계와 연계한 내수침수모형의 개발 및 검증)

  • Kim, Ji-Sung;Han, Kun-Yeun;Lee, Chang-Hee
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.12 s.173
    • /
    • pp.1013-1022
    • /
    • 2006
  • Urban flooding is usually caused by the surcharge of storm sewers. For this reason, previous studies on urban flooding are mainly concentrated on the simulation of urban drainage systems. However these approaches that find the pipes which have insufficient drainage capacity are very approximate and unreasonable ways in establishing both flood prevention and flood-loss reduction planning. In this study, a two-dimensional model linked the existing ILLUDAS model is developed to calculate the accurate and resonable solution about urban flood inundation and it is verified by using the simulation of July 2001 flood in Seoul. In the urban area with a small difference of ground elevations, the two-dimensional flood propagation phases must be considered to make a accurate analysis for inundated area and depth. The result of this study can be used to construct fundamental data for a flood control plan and establish a urban flood forecasting/warning system.

A Study on Functional Design of Electronic Records Management System in Records Centers (전자기록관리시스템의 기능 설계에 관한 연구)

  • Kim, Yong
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.7 no.1
    • /
    • pp.61-82
    • /
    • 2007
  • With changes of information environment on records managements, ERMS can be a suitable solution for managing multi-typed records. In this point, this study performed analysis and design of ERMS based on key functions and requirements to perform creation, preservation, management and use of electronic records. Especially, this study focused on interoperability with the related systems, security issues and back-up methods for secured preservation and management including fundamental requirements. Also, ERMS has a close relation with related systems such as intranet system, electronic document settlement system, and so on. compared to digital library managing information resources. Considering those features mentioned above, this study proposes functional requirements and a system architecture of ERMS which is satisfied with four characteristics of electronic records mentioned on ISO 15489 and environmental requirements.

Some Basic Investigation on Wireless Power Transfer (무선 전력 전송에 관한 기본적인 고찰)

  • Park, Jongmin;Nam, Sangwook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.10
    • /
    • pp.959-965
    • /
    • 2014
  • This paper summarizes the previous research results of fundamental investigation done in SNU on the wireless power transfer. Firstly, the physical limitation of a wireless power transfer using the spherical modes is reviewed. It is found that wireless power transfer depends only on the radiation efficiency of the antennas and the distance between two antennas involved. Secondly, we review the characteristics of WPTS with different sources and compare the performance differences of WPTS according to the source type. In addition, the method for efficient WPTS is suggested when the distance between antennas is varied. Finally, by using the time domain solution of the coupled mode equation, we present an analytic formula which can be used to differentiate Inductive Coupling(IC) and Magnetic Resonance Coupling(MAC) which are often used ambiguously in wireless power transfer system.

Photolytic Characteristics of Ni-TiO2 Composite Coating from Electroless Plating (무전해 Ni-TiO2 복합도금을 이용한 광분해 특성 연구)

  • Choi, Chul-Young;Han, Gil-Soo;Jo, Il-Guk;Kim, Young-Seok;Kim, Yang-Do
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.4
    • /
    • pp.157-160
    • /
    • 2009
  • Many fundamental studies have been carried out regarding waste water and hazardous gas treatments technologies using the photolysis effect of $TiO_2$. However, a permanent use of $TiO_2$ particles immobilized using organic or organic-inorganic binders is impossible. In this study, Ni-$TiO_2$ composite coating was produced by electroless plating to trap $TiO_2$ particles in the Ni coating layer. The electroless plating was performed in the bath solutions with three different concentrations of $TiO_2$ particles : 10 g/l, 20 g/l, and 40 g/l. The surface and photolytic characteristics of the coating layer was investigated by the use of SEM, a scratch tester, and an UV-Visible spectrophotometer. The results showed that the amounts of immobilized $TiO_2$ particles and the photolytic rate of the coating increased with the initial content of $TiO_2$ particles in the electroless bath. In addition, the photolytic rate of the Ni-$TiO_2$ composite coating was remarkably promoted by etching process in 10% HCl solution.

A Study on RFID Based QoS Guarantee between O/D Container terminals for Biz-Model (RFID을 활용한 기종점 컨테이너 터미널간 QoS 보장을 위한 비즈니스 모델 연구)

  • Park Doo-Jin;Kim Hyun;Nam Ki-Chan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.303-309
    • /
    • 2005
  • This paper will suggest how can we guarantee terminal QoS like ship waiting time ratio and ship residing time applying RFID(Radio Frequence Identification) technology, raising up rapidly as a fundamental solution of new growing industry, to port information system. Also, lead time of whole port logistics can be decreased for reduction of loading & discharging time resulted from productivity improvement of Twinlift G/C(Gantry Crane) and Y/T(Yard Tract) etc as applying RFID technology to terminal operation. The purpose of this paper is suggesting of new business model of u-Port that port QoS can be guaranteed from mutual agreement of each terminals RFID technology applied and focusing on the implementation plan.

  • PDF

Structural and Physicochemical Studies on DA-5018, a New Capsaicin Derivative (새로운 Capsaicin 유도체 DA-5018의 구조 및 물리화학적 성질 연구)

  • Kim, Heung-Jae;Lee, Jong-Jin;Lee, Eung-Doo;Shim, Hyun-Joo;Lee, Sang-Deuk;Ok, Kwang-Dae;Kim, Won-Bae;Park, No-Sang
    • Journal of Pharmaceutical Investigation
    • /
    • v.27 no.2
    • /
    • pp.119-123
    • /
    • 1997
  • The physicochemical and structural properties of new capsaicin derivative, DA-5018, were examined. The reference standard of this compound was obtained by the recrystallization. A method for the determination of the dissociation constant of the compound is described. pH-solubility and distribution coefficient were determined by chromatographic method. Fundamental properties on thermal behaviors were investigated by TG, DTA and DSC. Structural analysis based on spectroscopic method coincided with the chemical structure of DA-5018. Approximate dissociation constant of the compound determined by UV spectral method was 9.35. Solubilities and partition coefficients in various pH buffer solution appeared pH-dependency. No crystal transition or further transition was found in the thermal analysis. This compound showed good stability, but pH 13 buffer and acetone made some degradative products.

  • PDF

Fundamental Studies for the Automatic Control System in the Greenhouse Using Microcomputer(II) -A Development of a Controller for an Automatic Control System- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(II) -자동화 시스템의 종합제어기 개발-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • v.20 no.1
    • /
    • pp.73-86
    • /
    • 1995
  • The automatic control system in the greenhouse have to be developed to the direction of considering various factors the variables such as condition of the cultivation and greenhouse, the properties and types of products. Therefore, it is more important to set up variables appropriately than the problems of automatic control system itself, and the automatic control system which satisfy these problems should be simplified in the aspect of operation. In addition, even the individual automations are not perfect yet, so more studies are required for the development of comprehensive automatic system in korea. This study was carried out to automatize environment control systems for greenhouse, especially from most intensive labor requiring parts such as watering, irrigating liquefied fertilizer, spraying chemicals, mixing and ventilation system, etc. The results are summarized as follows. 1. Control type tensiometer was expected to be desirable in the automation of watering system, therefore, a new tensiometer was designed and developed through this study. 2. The chemical spraying system developed through this study was found to be excellent in the aspect of operation. 3. When pulse type water discharge meter was used in the mixing of liquefied fertilizer and chemical solution, the error of mixing were range $\pm$0.1~0.15%. 4. The water level switch of electrod type used for controlling water level was found to be affective in both control performance and operation cost. 5. The water and level control system can be omitted if each tank size are standardized in accordance with greenhouse size, therefore, the installation cost might be significantly reduced. 6. The developed general controller was excellent in hardware parts, but still remained to be improved in software parts.

  • PDF