A Novel System with EMG-controlled FES Enhanced Gait Function and Energy Expenditure for Older Adults
-
- Physical Therapy Rehabilitation Science
- /
- v.13 no.2
- /
- pp.152-162
- /
- 2024
Objective: This study was conducted to analyze the effect of wearable Electromyography-controlled functional electrical stimulation (EMG-controlled FES) System on Gait Function and cardiopulmonary metabolic efficiency during walking in older adults. Design: Cross-section study Methods: Total 22 older adult participants suitable to selection criteria of this study participated in this study. The EMG-controlled FES System, which functions as a wearable physical activity assist FES system was used. All participations performed randomly assigned two conditions (Non-FES assist [NFA], FES assist [FA]) of walking. In all conditions, spatio-temporal parameters and kinematics and kinetics parameters during walking was collected via 3D motion capture system and 6 minutes walking test (6MWT) and metabolic cost during walking and stairs climbing was collected via a portable metabolic device (COSMED K5, COSMED Srl, Roma, Italy). Results: In Spatio-temporal parameters aspects, The EMG-controlled FES system significantly improved gait functions measurements of older adults with sarcopenia at walking in comparison to the NFA condition (P<0.05). Hip, knee and ankle joint range of motion increased at walking in FA condition compared to the NFA condition (P<0.05). In the FA condition, moment and ground reaction force was changed like normal gait during walking of older adults in comparison to the NFA condition (P<0.05). The EMG-controlled FES system significantly reduced net cardiopulmonary metabolic energy cost, net energy expenditure measurement at stairs climbing (P<0.05). Conclusions: This study demonstrated that EMG-controlled FES is a potentially useful gait-assist system for improving gait function by making joint range of motion and moment properly.
Objective : Post-stroke shoulder pain (PSSP) is a common complication that limits the range of motion (ROM) of the shoulder, the patient's rehabilitation and in turn, affects the patients' quality of life (QoL). Several treatment modalities such as sling, positioning, strapping, functional electrical stimulation, and nerve block have been suggested in literatures, however none of the treatments had long-term effects for PSSP. In this study, the authors evaluated clinical efficacy of pulsed radiofrequency (PRF) neuromodulation on the suprascapular nerve for PSSP, and suggested it as a potential treatment with long-term effect. Methods : This retrospective case series was conducted at a single center, a private practice institution. From 2013 to 2021, 13 patients with PSSP underwent PRF neuromodulation of the suprascapular nerve. The primary outcome measure was the Visual analog scale (VAS) score. The secondary outcome measurements included the shoulder ROM, Disability assessment scale (DAS), modified Ashworth scale, modified Rankin scale (mRS), and EuroQol-5 dimension-3L questionnaire (EQ-5D-3L) scores. These parameters were evaluated before PRF modulation, immediately after PRF modulation, and every 3 months until the final follow-up visit. Results : Six men and seven women were enrolled, and all patients were followed-up for a minimum of 12 months. The mean VAS score was 7.07 points before PRF neuromodulation and 2.38 points immediately post-procedure. Shoulder ROM for abduction and flexion, DAS for pain, mRS, and EQ-5D-3L demonstrated marked improvement. No complications were reported. Conclusion : PRF neuromodulation of the suprascapular nerve is an effective modality in patients with PSSP, and has long-term effect of pain relief, improvement of QoL.
Objectives: There have been several studies evaluated effect of electroacupuncture (EA) on spasticity but most studies could not assess spasticity quantitatively because they used clinical rating scales for assessment spasticity. The objective of this study is to evaluate effect of EA on poststroke spasticity quantitatively using tendon reflex (T-reflex). Methods: 29 stroke patients with upper extremity spasticity were randomized to EA group and control group. The EA group received combined EA and rehabilitation therapy 5 times a week for 3 weeks. Acupuncture treatment was given at Jian Yu (LI 15), Qu Chi (LI 11), Shao Hai (HT 3), Wai Guan (TE 5), He Gu (LI 4), Lie Que (LU 7), Hou Xi (SI 3) of the affected side, 30 minutes of electrical stimulation with a frequency of 40/13 Hz was applied at Qu Chi (LI 11), He Gu (LI 4). The control group received only rehabilitation therapy. The efficacy of treatment was assessed using T-reflex latency and amplitude, modified Ashworth scale (MAS) of biceps brachii, brachioradialis and triceps brachii. Fugl-Meyer motor function assessment (FMA) and functional independence measure (FIM) were also measured to assess motor function and functional independence. All outcomes were measured before treatment, immediately after 3 weeks of treatment and 1 week after 3 weeks of treatment. Results: No statistically significant differences were found in outcomes including T-reflex between the study groups except for FIM values immediately after 3 weeks of treatment (p=0.037). Conclusions: These results suggest that 3 weeks of EA does not reduce poststroke upper extremity spasticity electrophysiologically and clinically. However, small sample sizes and contradictory tendency between results from T-reflex and those from MAS require cautious judgement on interpretation of the results. A larger, well-designed clinical trials for quantitative evaluation of effect of EA on poststroke spasticity will be needed.
Frontotemporal dementia, the second most common cause of early onset dementia, is a neurodegenerative clinical syndrome characterized by progressive deficits in behavior, executive function and language. Although motor symptoms in frontotemporal dementia are represented by motor neuron disease, parkinsonism and progressive supranuclear palsy syndrome, there have been no reports of motor weakness caused by the direct involvement of central motor nervous systems in frontotemporal dementia. Moreover, no association between clinical dementia groups and complex regional pain syndrome has been reported. We diagnosed a rare case with motor weakness and complex regional pain syndrome of lower limbs due to central nervous system lesion in a patient with frontotemporal dementia by magnetic resonance imaging, electrodiagnostic study and three phase bone scan. Following steroid therapy for complex regional pain syndrome, pain was improved. Functional improvement was noted after rehabilitation therapy, including functional electrical stimulation, muscle strengthening exercise and gait training during hospitalization. This case report suggests that rehabilitation therapy for motor weakness in frontotemporal dementia could be effective for improving overall function.
his study was to investigate effects of improvement of balance abilities through 8-weeks Transcutaneous Electrical Nerve Stimulation (TENS) and balance training in the women elderly. 42 women elders who were participated in silver college. Randomized study design of two groups was used: TENS group (21 women, 84.53 years old) and balance training group(21 women, 79.93 years old). Each group had a application of TENS, balance training by a researcher three times per week for 8 weeks. Measurements of static postural sway velocity on the floor and foam, timed get up and go test (TUG), functional reach test (FRT), and lateral functional reach test (LFRT) were evaluated at initial presentation (pretest) and after completion of the each intervention program (posttest). The results showed that the TUG was significantly decreased in all groups (p<.05) and the postural sway velocity using force plate in all conditions was significantly decreased in all groups (p<.05). FRT and LFRT were significantly increased in all groups (p<.05). There were significantly differences in TUG and postural sway velocity on the eye closed condition between two groups (p<.05). In conclusion, the application of TENS to older adults whose somatosensory were deteriorated was effective for improvement balance ability.
The following results were obtained, after experimenting on change of masseter muscle and bloodstream epithelium with Transcutaneous Electrical Nerve Stimulator(TENS), among 16 male adults. 1. According to applying TENS, it was observed that bloodstream in muscle increases at 1.5, 3.0 Hz. 2. According to applying TENS, it was observed that concentration of moving blood cells in muscle increase at 1.5, 3.0, 6.0 Hz. 3. According to applying TENS, it was observed that velocity of bloodstream in muscle increases only at 1.5 Hz 4. Through experiment, applying TENS at level of 6.0 and 10.0 Hz, all bloodstream, concentration of moving blood cells, and velocity of bloodstream increasing rates were lower in muscle compared to of them in overlying epithelium; and especially increasing bloodstream and its velocity were most frequent at 6.0 Hz, and bloodstream of 10.0 Hz. From the results above when a physical therapy of TENS is carried out the frequency of 1.5, 3.0 H is effective, and as the frequency increases it is disadvantageous to the muscle.
Retinal ganglion cells transmit visual scene as an action potential to visual cortex through optic nerve. Conventional recording method using single intra- or extra-cellular electrode enables us to understand the response of specific neuron on specific time. Therefore, it is not possible to determine how the nerve impulses in the population of retinal ganglion cells collectively encode the visual stimulus with conventional recording. This requires recording the simultaneous electrical signals of many neurons. Recent advances in multi-electrode recording have brought us closer to understanding how visual information is encoded by population of retinal ganglion cells. We examined how ganglion cells act together to encode a visual scene with multi-electrode array (MEA). With light stimulation (on duration: 2 sec, off duration: 5 sec) generated on a color monitor driven by custom-made software, we isolated three functional types of ganglion cell activities; ON (35.0
Objective : The purpose of this study was to systematically review dysphagia rehabilitation treatment for children with feeding disorders. Methods : The articles evaluated in this study were collected from the PubMed, Medline Complete, and CINAHL databases and subsequently reviewed using the PRISMA flow chart and PICOS approach. A total of 13 papers were analyzed for study quality, disease groups, evaluation tools, interventions, and post-intervention effects. Results : Of the reviewed papers, six (46.15%) related to autism spectrum disorder (ASD) and seven (53.85%) to cerebral palsy (CP) with age ranges of between 2 and 8 years for the ASD studies and between 12 months and 18 years for CP. In evaluating the types of feeding disorder involved, the ASD group exhibited predominantly behavioral conditions while the CP subjects had a larger number of functional oral and swallowing issues. In terms of interventions, behavior modifications were used most frequently with ASD while oral-sensory motor, texture modifications, and electrical stimulation were applied at the same frequency with children with CP. All interventions were found to be effective. Conclusion : In this study, research into children with feeding disorders was reviewed according to condition, evaluation tool, and method of intervention. It is expected that this review can be used as basic data for developing a protocol that will allow clinicians to efficiently apply condition-specific interventions for eating disorders without resorting to trial and error.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70