• 제목/요약/키워드: functional effect

검색결과 5,433건 처리시간 0.05초

소인제(Aeonium sedifolium) 잎 유래 phenolic 성분의 항산화, 피부주름생성 억제, 항염증 및 모공 수축 효과 (Anti-oxidation, anti-inflammation, anti-wrinkle, and pore-tightening effects of phenolic compounds from Aeonium sedifolium leaves)

  • 김정인;김민재;조하경;정다은;박혜진;조영제
    • 한국식품저장유통학회지
    • /
    • 제30권2호
    • /
    • pp.347-357
    • /
    • 2023
  • 소인제(Aeonium sedifolium) 잎의 total phenolics compounds 함량은 열수 및 ethanol 추출물에서 각각 34.49 mg/g, 61.64 mg/g으로 나타났다. 소인제 잎의 solid에 비해 phenolics의 DPPH, ABTS 효과가 더 우수한 결과를 나타내어 생리활성은 phenolic에 의해 발생하는 것으로 확인되었다. 소인제 잎의 항산화 효과는 DPPH가 100 ㎍/mL TPC 농도에서 85% 이상의 높은 소거 활성을 나타내었고, ABTS radical cation decolorization은 열수와 ethanol 추출물에서 모두 100%에 근접한 항산화 활성을 나타내었다. Antioxidant protection factor는 100 ㎍/mL phenolic 농도에서 열수와 ethanol 추출물에서 각각 1.07 PF와 1.22 PF를 나타내었으며, TBARs 저해 효과는 열수와 ethanol 추출물 모두 77% 이상의 활성을 나타내었다. 소인제 잎 추출물의 elastase 저해 활성은 phenolic 100 ㎍/mL의 ethanol 추출물에서 69.03%로, positive control인 ursolic acid의 35.83%보다 2배의 억제효과를 나타내었다. Collagenase 저해활성은 phenolic 농도 100 ㎍/mL에서 열수추출물이 29.82%, ethanol 추출물이 54.76%의 저해 효과를 나타내어 주름개선효과가 우수한 것으로 확인되었다. 소인제 잎의 HAase 저해활성은 400 ㎍/mL phenolic 농도의 열수 및 에탄올 추출물에서 각각 85%, 99.12%의 높은 저해활성을 나타내었다. 소인제잎 추출물의 모공수축 효과는 phenolic 농도 400 ㎍/mL에서 100% 가까운 매우 우수한 효과를 나타내었다. 이상의 결과를 종합해보면 소인제 잎 추출물은 항노화에 관여하는 높은 항산화 활성을 나타내었으며, 피부 주름 생성에 관여하는 elastase와 collagenase 저해활성과 염증반응에 관여하는 hyaluronidase 저해활성이 우수하였으며, 모공수축 효과 또한 매우 우수한 것으로 확인되었다.

왕벚나무 수피 추출물의 아미노산, 지방산 분석 및 항산화 활성 (Analysis of Amino Acids, Fatty Acids, and Antioxidant Activities of Prunus yedoensis Matsum. Bark Extracts)

  • 박성환;최예은;양정모;정채원;조현덕;조주현
    • 한국식품위생안전성학회지
    • /
    • 제39권3호
    • /
    • pp.288-298
    • /
    • 2024
  • 본 연구는 국내산 왕벚나무 수피를 건강기능식품 소재로서 활용 가능성을 확인하기 위하여 용매별 추출물에 대한 특성 분석과 항산화 활성을 평가하였다. 용매별 소재의 아미노산과 지방산 분석을 통하여 성분함량 및 조성 차이를 확인하였고, 항산화 활성 비교를 위해 총 폴리페놀 함량, 총 플라보노이드 함량, DPPH 라디칼 소거능, ABTS 라디칼 소거능, FRAP 활성을 측정 및 비교 후 상관관계를 분석하였다. 아미노산 분석 결과, 열수 추출물, 30% 에탄올 추출물, 70% 에탄올 추출물에서 13종의 아미노산이 검출되었고, 주요 아미노산으로 aspartic acid, arginine, proline으로 분석되었으며, 총 아미노산 함량은 각각 0.17%, 0.16%, 0.09%로 확인되었다. 지방산 분석 결과, 포화지방산(SFA)이 열수 추출물, 30% 에탄올 추출물, 70% 에탄올 추출물에서 62.7-66.7%로 높은 조성비를 보였고, 확인된 지방산은 열수 추출물에서 behenic acid (C22:0)을 제외한 13종의 지방산이 검출되었으며, 30% 에탄올 추출물과 70% 에탄올 추출물에서 14종 지방산이 검출되었다. 주요 지방산은 열수 추출물, 30% 에탄올 추출물, 70% 에탄올 추출물에서 palmitic acid (C16:0)로 확인되었고, 총 지방산 함량은 각각 0.66 mg/g, 2.46 mg/g, 10.04 mg/g으로 70% 에탄올 추출물에서 가장 높았다. 총 플라보노이드와 총 폴리페놀 함량은 열수 추출물, 30% 에탄올 추출물, 70% 에탄올 추출물에서 각각 727.70-769.87 mg QE/g, 309.24-348.09 mg GAE/g이었다. 항산화 활성 측정 결과 열수 추출물, 30% 에탄올 추출물, 70% 에탄올 추출물에서 DPPH 라디칼 소거능은 0.05-1 mg/mL 농도에서 각각 14.42-81.77%, 16.85-83.38%, 19.33-81.12%의 결과를 보였고, ABTS 라디칼 소거능은 0.05-1 mg/mL 농도에서 각각 6.32-89.55%, 16.14-70.61%, 8.99-92.08%의 결과를 보였으며, FARP 활성은 0.05-0.5 mg/mL 농도에서 각각 0.32-2.91, 0.07-0.61, 0.39-3.43으로 나타나 농도 의존적으로 항산화 효과를 증가시키는 것을 확인하였다. 용매별 추출물의 총 플라보노이드 함량, 총 폴리페놀 함량과 항산화 활성 간의 상관관계를 분석한 결과, 높은 양(+)의 상관성을 보였다(P<0.01). 본 연구결과를 통해 왕벚나무 수피 추출물을 이용한 건강기능식품 소재 개발의 기초 자료로 활용될 수 있을 것으로 사료된다.

뇌졸중환자의 물리치료경과에 따른 기능변화와 관련요인 (The Effect of Physical Therapy on Functional Change and Related Factors in Stroke Patients)

  • 이승주;예민해;천병렬
    • The Journal of Korean Physical Therapy
    • /
    • 제10권1호
    • /
    • pp.7-21
    • /
    • 1998
  • 본 연구는 뇌졸중 환자들의 퇴윈 후 1개월까지의 물리치료 양상 및 기능변화와 이에 관련된 요인을 알아보기 위해 1996년 11월 1일 부티 1997년 3월 31일까지 약 4개월 간 부산시 및 대구시, 안동시 등에 소재하고 있는 10개 병원에서 물리치료를 시작한 뇌졸중환자 101명을 대상으로 물리치료를 시작한 시점. 1개월 후, 퇴원 시, 그리고 퇴원 후 1개월이 지난 시점까지 추적하여 기능변화를 평가하였다. 뇌졸중환자의 물리치료 시작 시점의 BI점수는 $27.18\pm23.7$이었고, PS점수는 $17.54\pm4.33$이었다. 물리치료 시작시점을 기준으로 할 때 입원 1개월 후의 BI점수 변화는 평균 21.39(P<0.001), 퇴원시는 37.47(P<0.001), 퇴원 1개월 후는 46.49 만큼 호전되었다(P<0.001). PS점수도 각각 -2.02, -4.52, 리고 -6.26만큼 호전되었다(P<0.001). 그리고 퇴원시에 비해 퇴원후의 변화도 BI점수는 9.01만큼, PS점수는 -1.73만큼 유의하게 호전되었다.(P<0.001). 물리치료 시작시점과 퇴원 시의 BI점수 변화와 유의한 관련이 있는 요인은 물리치료 시작시점의 BI점수와 연령으로 (p<0.05), 물리치료 시작시점의 BI점수가 낮고 연령이 40세 미만에서 기능호전이 컸다. 물리치료 시작시점과 종료시점 사이의 BI점수의 변화는 물리치료 시작시점의 BI점수, 퇴원 1개월 후에 적극적으로 물리치료를 받았는지의 여부, 연령 그리고 수술여부와 유의한 관련성이 있었다. (p<0.05). 즉, 무리치료 시작시점의 BI점수가 낮고, 퇴원 1개월 후에 적극적으로 물리치료를 받은 환자, 연령 40세 미만에, 그리고 수술을 받지 않은 환자에서 기능호전이 컸다. 퇴원시와 퇴원 1개월 후의 BI점수 변화와 관련 있는 변수는 퇴원시의 BI점수, 마비부위, 종교유무 이었는데, 퇴원시의 BI점수가 낮고 좌측마비환자이며 종교를 믿는 환자의 기능호전이 유의하게 컸다(p<0.05). 물리치료 시작시점과 퇴원시의 PS점수 변화와 유의한 관련이 있는 요인은 물리치료 시작시점의 PS점수와 연령이었는데(p<0.05), 물리치료 시작시점의 PS점수가 높고 40세 미만에서 기능호전이 컸다. 물리치료 시작시점과 종료시점 사이의 PS점수 변화와 관련 있는 분수는 물리치료 시작시점의 PS점수, 퇴원 1개월 후에 적극적으로 물리치료를 받았는지의 여부, 연령, 교육수준, 퇴원 후 물리치료 받은 기간, 수술여부 등이었다.(p<0.05). 즉, 물리치료 시작시점의 PS점수가 높고, 퇴원 1개월 후에 적극적으로 물리치료 받은 환자, 연령이 40세 미만, 학력이 높을수록, 퇴원 후 물리치료 받은 기간이 짧은 환자, 그리고 수술을 받지 않은 환자에서 기능호전이 컸다. 퇴원시와 퇴원 1개월 후의 PS점수의 변화는 퇴원시 PS점수가 높고, 학력이 높을수록, 퇴원 1개월 후에 적극적으로 물리치료를 받은 환자, 그리고 퇴원 후 물리치료 기간이 짧고, 남자에서 기능호전이 유의하게 컸다.(p<005). 이상의 결과를 요약하면, 뇌졸중환자의 물리치료 효과를 BI점수로 평가하면 물리치료 시작시점의 BI점수와 연령이 중요한 요인이고, PS점수로 평가하면 역시 물리치료 시작시점의 PS점수와 연령 그리고 교육수준이 중요한 요인으로 생각된다.

  • PDF

치료 저항성 우울증 환자에서 반복적 경두개 자기자극후 국소뇌혈류 변화 (Effect of Repetitive Transcranial Magnetic Stimulation in Drug Resistant Depressed Patients)

  • 정용안;유이령;강봉주;채정호;이혜원;문현진;김성훈;손형선;정수교
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권1호
    • /
    • pp.9-15
    • /
    • 2007
  • 목적: 두부 외부에서 두뇌를 직접 자극하는 비침습적 두뇌 자극술인 경두개 자기자극(TMS, transcranial magnetic stimulation)은 특정 두뇌 부위를 자극하여 두뇌 활성을 증가 혹은 감소시킬 수 있다. 특히 반복 TMS(repetitive TMS, 이하 rTMS)는 우울증, 강박장애, 정신분열증 등 일부 신경 정신과적 질환의 새로운 치료법으로서의 가능성이 제시되면서 다양한 연구가 행해지고 있다. 이에 본 연구는 치료 저항성 우울증 환자를 대상으로 rTMS 치료 전후의 국소뇌혈류 변화를 알아보고자 하였다. 대상 및 방법: 1년 이상 적당한 항우울제 투여를 시도하였음에도 불구하고 치료에 반응하지 않았던 치료 저항성 우울증 환자 12명(남: 7, 녀: 5, 나이범위: $19{\sim}52$세, 평균나이: $29.3{\pm}9.3$세)을 대상으로 하여 3주간 15회의 rTMS(우측 전전두엽: 1Hz, 좌측 전전두엽: 20Hz) 치료 시행 전과 치료 후에 Tc-99m ECD SPECT를 얻었다. 치료 전과 후의 차이를 SPM2 소프트웨어를 이용하여 비교하였다.(t=3.14, uncorrected p<0.01, voxel=100) 결과: rTMS 치료 후에 좌측 측두엽 전내측부와 좌측 기저핵 그리고 양측 전전두엽 피질부위에 혈류가 유의하게 증가하였다. 또한 우측 전두엽과 좌측 후두엽에서는 혈류가 유의하게 감소하였다. 결론: 치료 저항성 우울증 환자의 rTMS 치료는 특정 부위 두뇌의 혈류 증가와 감소가 있음을 확인할 수 있었다. 치료 성과 및 개인 특성에 따른 차이에 대한 분석을 시행하고 보다 많은 수의 환자에서 자료가 확보된다면 rTMS 치료의 기전과 우울증의 병태생리를 규명하는데 rTMS-기능 뇌영상 연계 연구가 매우 유용할 것이다.인 PET 연구 절차를 고안하기 위해 고려해야 할 사항들에 대하여 논하였다.TEX>$29.9{\pm}1.8%$, DMF: $7.6{\pm}0.5%$이었다. MEK에서 얻은 $[^{11}C]1$의 비방사능은 98 ($GBq/{\mu}mol$)이다. 각 물질의 질량 분석은 1: m/z 257.3 (M+1), 2: 257.3 (M+1), 3: 271.3 (M+1)이었다. 각 생성물질의 표지효율은 MEK에서 $86.0{\pm}5.5%:5.0{\pm}3.4%:1.5{\pm}1.3%$ $([^{11}C]1:[^{11}C]2:[^{11}C]3)$, CHO에서 $59.7{\pm}2.4%:4.7{\pm}3.2%:1.3{\pm}0.5%$, DEK에서 $29.9{\pm}1.8%:2.0{\pm}0.7%:0.3{\pm}0.1%$, DMF에서 $7.6{\pm}0.5%:0.0%:0.0%$이다. 결론: $[^{11}C]1$은 4가지 반응용매 중 MEK 반응용매에서 가장 높은 표지효율을 나타냈다. 부산물인 $[^{11}C]3$은 고성능 액체 크로마토그래피의 자외선, 방사능 검출기와 질량 분석법을 통해 물질을 추정할 수 있었다.의 개선 효과가 있는 것으로 판단되며 지질과산화에 대해서 강한 억제 활성을 나타내는 것을 알 수 있었다. 이러한 결과로 복분자는 생활 습관병의 예방과 개선에 유효한 것으로 사료되었으며, 지질대사와 과산화지표의 검증을 통해 기능성 식품소재로 활용될 수 있음을 보여주었다.로서 역시 CTV 치료계획에서 적게 조사되었다(p=0.005). 기존의 ICRU 치료계획은 잔류종양의 크기가 작은 경우 불필요하게 정상조직에

실험적 급성호흡부전에서 호기말양압에 의한 폐유순도와 산소운반의 변화 및 상관관계 - 호흡부전의 기전에 따른 차이 - (Relationship of Compliance and Oxygen Transport in Experimental Acute Respiratory Failure during Positive End-Expiratory Pressure Ventilation)

  • 이상도;윤세진;이복희;한성구;심영수;김건열;한용철
    • Tuberculosis and Respiratory Diseases
    • /
    • 제40권1호
    • /
    • pp.6-15
    • /
    • 1993
  • 연구배경 : 성인성 호흡곤란증후군에서 호기말양압(PEEP)이 저산소혈증을 호전시키는 기전은 감소된 기능적잔기량의 증가에 따른 생리적단락의 감소이며 어느 수준 이상의 PEEP에서는 심박출량이 유의하게 감소해 산소운반은 오히려 감소하는 것으로 알려져 있다. 산소운반이 최대인 PEEP 수준을 결정하는 비관혈적 지표로 폐유순도(compliance)가 보고되었으나 이의 유용성에 대해서는 논란이 많다. 한편 급성 폐동맥색전증은 성인성 호흡곤란증후군과는 달리 기능성 잔기량의 감소가 유의하지 않은 질환이며 따라서 PEEP의 적용에 따른 환기 및 혈류역학의 변화도 다를 것으로 추측된다. 저자들은 성인성 호흡곤란증후군과 급성 폐동맥색전증에서 총정적유순도(total static compliance)가 산소운반을 최대로하는 PEEP 수준의 결정에 유용한 지표로 이용될 수 있는가를 검정해보고, 성인성 호흡곤란증후군과는 저산소증의 기전이 다른 급성 폐동맥색전증에서 PEEP 적용에 따른 환기 및 혈역학의 변화에 대한 기초자료를 제공하고자 본 연구를 시행 하였다. 방법 : 한국산 잡견 14마리중 7마리에는 oleic acid 0.07ml/kg를 정주해 성인성 호흡곤란증후군을 유발하고, 나머지 7마리에는 자가혈병을 이용해 급성 폐동맥색전증을 유발한 후 PEEP 수준을 0, 5, 8, 12, 15 cm$H_2O$로 증가시켜가며 환기 및 혈역학의 제지표를 측정하였다. 결과: 1) PEEP수준의 증가에 따른 환기 및 혈역학의 변화 ARDS군에서 PEEP수준의 상승에 따라 동맥혈 산소분압및 동맥혈 이산화탄소분압은 증가하였고, 생리적단락과 심박출량은 감소하였다 (p<0.05). 급성 폐동맥색전증군에서도 PEEP수준의 상승에 따라 생리적단락 및 심박출량은 감소하였고, 동맥혈 산소분압 및 동맥혈 이산화탄소분압은 증가하였다 (p<0.05). PEEP수준 1 cm$H_2O$ 상승에 따른 변화로 심박출량의 감소는 급성 폐동맥색전증군에서 ARDS 군에 비해 유의하게 컸고, 동맥혈 산소분압, 동맥혈 이산화탄소분압, 생리적단락 및 폐혈관저항의 변화는 두군간에 유의한 차이가 없었다. 2) 산소운반과 총정적유순도 ARDS군에서 총정적유순도와 산소운반은 PEEP 적용후 증가해 5 cm$H_2O$에서 가장 컸으며 (p<0.05), 급성 폐동맥색전증군에서는 PEEP 적용후 총정적유순도와 산소운반이 감소하였다(p<0.05). 양군 모두 산소운반이 최대인 PEEP 수준에서 총정적유순도도 최대치를 기록하였다. ARDS군에서 산소운반의 변화와 총정적유순도의 변화사이에는 유의한 상관관계가 있었고 (r=0.86, p<0.01), 급성 폐동맥색전증군에서도 산소운반의 변화와 총정적유순도의 변화사이에 약한 상관관계가 있었다(r=0.60, p<0.01). 결론 : 이상의 결과로 ARDS와 급성 폐동맥색전증에서 PEEP의 적용시 산소운반을 최대로 유지하기 위한 PEEP수준의 결정에 총정적유순도가 유용한 지표로 이용될 수 있을것으로 생각된다.

  • PDF

제주도(濟州道) 화산회토양(火山灰土壌)의 이화학적(理化学的) 특성(特性) 및 유기물(有機物) 성상(性状)에 관(関)한 연구(硏究) (Studies on the Physico-chemical Properties and Characterization of Soil Organic Matter in Jeju Volcanic Ash Soil)

  • 이상규;차규석;김인탁
    • 한국토양비료학회지
    • /
    • 제16권1호
    • /
    • pp.20-27
    • /
    • 1983
  • 제주도(濟州道) 화산회토양유기물(火山灰土壌有機物)의 화학성(化学性), 유기물(有機物) 성상(性狀) 및 부식산(腐植酸)의 광학적(光学的) 특성(特性)을 알고져 수종(数種)의 화산회토양(火山灰土壌)을 공시(供試)하여 실내시험(室內試験)한 결과(結果)를 요약(要約)하면 다음과 같다. 가. 토양(土壌)의 화학적(化学的) 성질(性質) 1) 화산회토양(火山灰土壌)은 비화산회토양(非火山灰土壌)에 비(比)하여 유기물(有機物)(4~27%), 유효규산(有効珪酸)(291~884ppm), 활성(活性) 알루미늄(150~478ppm) 및 활성철함량(活性鉄含量)(0.77~0.86%)이 많고 반대(反対)로 유효인산(有効燐酸)(4~15ppm) 함량(含量)이 현저(顕著)히 낮았다. 2) 가리(加里), 석화(石火), 고토등(苦土等)은 밭의 경우 화산회토양(火山灰土壌)에서 높은 편이나 삼림지(森林地) 및 유휴지토양(遊休地土壌)은 낮은 경향(傾向)을 보였다. 3) 화산회토양(火山灰土壌)은 규반비(珪礬比) 및 규산(珪酸)/유기물비(有機物比)가 낮은 반면(反面) K/Ca+Mg, Al/Fe(활성(活性)) 및 C/P비(比)가 현저(顕著)히 높았다. 나. 유기물(有機物) 및 질소분별정량(窒素分別定量) 1) 화산회토양(火山灰土壌)은 유기물(有機物)의 총탄소중(総炭素中) Humin-C의 비율(比率), 유기물중(有機物中) Humin산(酸) 그리고 Humin중(中) C/N율(率)이 비화산회토양(非火山灰土壌)보다 현저(顕著)히 높았다. 2) 화산회토양(火山灰土壌)은 비화산회토양(非火山灰土壌)에 비(比)하여 총질소(総窒素), 산(酸) 및 알카리가용성(可溶性) 질소함량(窒素含量)이 현저(顕著)히 높은 반면(反面) 총질소중(総窒素中) 무기태질소(無機態窒素)로 방출(放出)될 수 있는 무기화율(無機化率)은 높지 않았다. 다. 토양부식(土壌腐植)의 형태(形態) 1) 화산회토양(火山灰土壌)은 비화산회토양(非火山灰土壌)에 비(比)하여 광흡(光吸) 수능(收能)이 높고(K600, RF치(値), ${\delta}logK$) 부식화도(腐植化度)가 진전(進展)될수록 색농도(色濃度)가 짙은 것으로 나타났다. 2) 화산회토양(火山灰土壌)은 산화제(酸化劑)에 대(対)한 저항성(抵抗性)이 높고 산(酸) 및 알카리 가수분해성(加水分解性)이 강(强)하여 부식화도(腐植化度)가 높아 부식(腐植)의 자연분해(自然分解)가 극(極)히 어려운 것으로 나타났다. 라. Humin의 관능기조사(官能基調査) 화산회토양(火山灰土壌)의 유출부식산(油出腐植酸)의 관능기(官能基)는 phenolic-OH기(基), Alcoholic-OH기(基) 및 Carboxyl기(基)가 많고 비화산회토양(非火山灰土壌)은 Methoxyl기(基) 및 Carbonyl기(基)가 많았다. 마. 부식산(腐植酸)의 흡광도(吸光度) 1) 공시토양(供試土壌)의 가시광역(可視光域)은 200~500nm부근의 단파장영역(短波長領域)이었으며 주로 350, 420, 450 및 480nm 에서 4개(個)의 흡광곡선(吸光曲線)을 나타내었다. 2) 화산회토양(火山灰土壌)인 흑악통(黑岳統)은 362nm부근에서 단일(單一)의 높은 흡광도(吸光度)를 보였으며 비화산회토양(非火山灰土壌)인 영악통(永楽統)은 360nm와 390nm에서 2개(個)의 단순(單純)한 높은 흡광대(吸光帶)를 나타내었다. 마. 분해촉진제(分解促進剤) 처리효과(處理効果) 화산회토양(火山灰土壌)에 대(対)한 분해촉진효과(分解促進効果)는 이도통(統)은 역분해성(易分解性) 유기물(有機物) 첨가(添加)에 따른 "Priming Effect"가 증가(增加)되었으며 남원(南元)과 흑악통(黑岳統)은 Na-Pyrophosphate의 첨가효과(添加効果)가 있었다.

  • PDF

감염성 승모판 심내막염의 중단기 수술 성적 (Early and Mid-term Results of Operation for Infective Endocarditis on Mitral Valve)

  • 안병희;전준경;유웅;류상완;최용선;김병표;홍성범;범민선;나국주;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • 제37권1호
    • /
    • pp.27-34
    • /
    • 2004
  • 배경: 감염성 심내막염은 다른 심장질환에 비해 유병률과 사망률이 높고, 대부분의 임상연구가 대동맥판에 발생한 심내막염에 편중되어 있어, 승모판 심내막염에 대한 보고는 상대적으로 드문데 이에 대한 임상양상 및 수술 결과를 분석하여 보고하고자 한다. 대상 및 방법: 1995년 6월부터 2003년 5월까지 전남대학교병원에서 감염성 승모판 심내막염으로 단일 술자에 의해서 외과적 치료를 받았던 23 예을 대상으로 하였다. 2예는 인공판막 심내막염이었고 나머지 21예는 자가판막 심내막염이었다. 환자의 평균 연령은 44.8$\pm$15.7 (11∼66)세였고 연령분포에는 큰 차이가 없었다. 17예에서는 혈역학적 불안정이나 거대 우종으로 응급수술을 시행하였다. 수술 전 12예에서 울혈성 심부전, 4예에서 신부전, 2예에서 비장 및 신장경색, 2예에서 일시적 뇌손상, 1예에서 뇌농양 소견을 보였다. NYHA 기능 분류상 Grade II가 7예, Grade III가 9예, Grade IV가 6예이었다. 술 전 심초음파상 승모판 역류우세가 19예, 협착우세가 4예이었으며, 우종은 20예(86.9%)에서 관찰되었다. 혈액배양 검사상 10예(43.4%)에서 원인균이 동종되었는데 Streptococcus viridans 5예, methicillin sensitive Staphylococcus aureus 2예, 그리고 Corynebacterium, Haemophillis, Gernella 각각 1예씩 이었다. 수술 적응증은 ACC/AHA 지침에 근거하였으며, 평균 외래 추적관찰기간은 27.6$\pm$23.3 (1∼97)개월이었다. 결과: 13예에서 승모판치환술을 시행하였는데 9예에서 기계판막을 사용하였고 4예에서 조직판막을 사용하였다. 10예에서 다양한 수기의 승모판성형술을 시행하였다. 동반수기로는 6예에서 대동맥판 치환술, 2예에서 삼첨판 성형술, 1예에서 변형된 미로수술, 1예에서 심실중격결손 낙합술을 시행하였다. 술 후 합병증으로는 출혈에 의한 재수술 2예, 종격동염 1예, 저심박출증 1예, 페렴 1예가 있었다. 술 후 30일 이내의 조기사망이나 병원 내 사망 및 판막 연관성 합병증은 없었다. 1예의 환자가 수술 3개월 후 다시 판막성형술을 받았고, 술 전 우종 전색에 의한 뇌경색을 보인 1예의 환자가 술 후 31개월에 뇌출혈로 사망하여 만기 전 체판막 연관성 사망률은 4.3%, 판막연관성 합병증은 8.6%였다. 1, 3, 5년 valve-related event free rate는 90.8%, 79.5%, 79.5%이었고 1, 3, 5년 생존율은 100%, 88.8%, 88.8% 이었다. 결론: 승모판 심내막염의 외과적 치료 시에는 감염된 조직의 완전 절제가 중요하며, 감염된 조직을 완전히 제거하면 대체물이나 수술 기법상의 차이가 결과에 미치는 영향은 크지 않을 것으로 판단되고, 술 전에 감염이나 우종 전색에 의한 뇌손상이 의심되는 환자에서는 술 후 추적관찰 중에도 뇌혈관 손상 가능성에 대해 주의 깊게 관찰하여야 할 것으로 생각된다.

화타협척혈 침자극에 의한 손상 말초신경의 재생효과에 관한 연구 (Studies of the Effects of Acupuncture Stimulation at Huatuo Jiaji(EX B2) Points on Axonal Regeneration of Injured Sciatic Nerve in the Rats)

  • 김대필;박영회;금동호
    • 한방재활의학과학회지
    • /
    • 제18권4호
    • /
    • pp.39-61
    • /
    • 2008
  • 목적 : 좌골신경 압좌손상으로 유발된 쥐의 모델을 이용하여 손상된 말초신경의 재생효과에 관한 침자극 효과를 세포분자학적, 조직학적 관점에서 연구하였다. 아울러 손상 좌골신경을 지배하는 척수신경근과 가까운 부위 경혈자극과 좌골신경이 지배하는 말초부위 경혈자극과의 침자극 효과를 비교 연구하였다. 방법 : 한쪽 좌골신경에 압좌손상을 유발 한 실험쥐들을 1주, 2주로 나눈 뒤 각각에 대해 격일로 1주군은 3회, 2주군은 6회의 침자극을 시행하였다. 손상 좌골신경의 재생효과를 비교실험하기 위해 정상군, 압좌손상만을 유발한 실험군, 침자극 군으로 나누었다. 침자극 군 중 한 군은 손상신경을 지배하는 척수신경근에 가장 가까운 2개의 화타협척혈(EX B2)에 자침(근위부 자극군)하였고, 다른 한 군은 말초부위에 위치한 족삼리혈(ST 36)과 위중혈(BL 40) 2곳에 자침(원위부 자극군)하였다. 실험 후 각각의 조직을 분리하여 Western blotting 혹은 Hoechst staining으로 Gap-43, Cdc2, Cdk2, Erk1/2 단백질을 분석 및 좌골신경의 각 세포수를 측정하였다. Retrograde tracing을 통해 L5의 DRG와 척수에서 말초신경 재생 효과를 관찰하였고, Immunofluorescence staining을 통해 신경돌기 가지의 신장 정도를 파악하였다. 결과 : 좌골신경 손상 7일된 실험쥐의 근위부와 원위부 침자극군에서 GAP-43와 Cdc2 단백질수준이 향상된 것으로 나타났다. Cdk2 단백질수준은 압좌손상 실험군에서 강하게 증가하였지만 침자극군과 비교해서 별다른 차이는 보이지 않았다. Phospho-Erk1/2 단백질수준은 침자극군에서 향상된 것으로 나타났다. 손상 7일과 14일 된 실험쥐의 손상 원위부에서 슈반세포 수가 증가하였으며 특히 근위부 침자극군에서 더욱 증가한 것으로 나타났다. Retrograde tracing을 이용한 검사 결과 침자극군에서 L5의 DRG와 척수의 염색 세포 수가 증가된 것으로 나타나 침자극이 축삭재생에 효과적인 것으로 나타났다. L5의 DRG 감각신경의 신경돌기 가지 신장정도 및 GAP-43 단백질의 발현 정도를 측정한 결과 근위부 침자극군에서 효과적으로 GAP-43 단백질의 발현 및 신경돌기 가지가 신장된 것으로 나타났다. 결론 : 본 실험결과 침치료가 손상 좌골신경의 재생에 효과적인 것으로 보여지며, 특히 손상된 좌골신경을 지배하는 척수신경근 주위 화타협척혈에 대한 침자극이 말초부위의 침자극에 비해 신경재생에 더욱 효과적인 것으로 나타났다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF