• 제목/요약/키워드: fully implantable hearing aids

검색결과 5건 처리시간 0.021초

완전 이식형 보청기 기술 평가 기반의 새로운 이식형 음향센서 제안 (Proposition of a New Implantable Acoustic Sensor Based on Technology Evaluation of Fully Implantable Hearing Aids)

  • 조진호;우승탁;임형규;정의성;이정현;이승하;성기웅
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.178-184
    • /
    • 2014
  • Key components of implantable hearing aids are consist of an acoustic sensor that collect external sound by suppressing the body noise, a signal processor module for compensation algorithm of hearing loss, and a output transducer which has tiny size but have high efficiency, respectively. In the partial implantable hearing aids, technologies of transducer and signal processor are so matured that can be applied not too much difficulty. However, due to the difficulties in implantable acoustic sensor technology, such as minimization of masticatory sound and damage of sensor's membrane from external impact, practical use of fully implantable hearing aids have not successful so far. In this paper, we have proposed a novel implantable acoustic sensor which has trans-tympanic structure, and is verified that the proposed method can be very useful for fully implantable hearing aids by cadaveric experiments.

피부에 의한 이득 감쇠를 줄이기 위한 FEA 시뮬레이션 기반의 이식형 마이크로폰 설계 및 구현 (Design and Fabrication of an Implantable Microphone for Reduction of Skin Damping Effect through FEA Simulation)

  • 한지훈;김민우;김동욱;성기웅;조성목;박일용;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.59-65
    • /
    • 2008
  • Nowadays, implantable hearing aids have been developed to solve the problems of conventional hearing aids. In case of fully implantable hearing aids, an implantable microphone is necessary to receive sound signal beneath the skin. Normally, an implantable microphone has poor frequency response characteristics in high frequency bands of acoustic signal due to the high frequency attenuation effect of skin after implantation to human body. In this paper, the implantable microphone is designed to reduce the high frequency attenuation effect of a skin by putting its resonance frequency at the attenuated range through a finite element analysis (FEA) simulation. The designed implantable microphone through the simulated results has been fabricated by manufacturing process using bio-compatible materials. By the several in-vitro experiments with pig skin, it has been verified that the designed implantable microphone has a resonance frequency around the starting part of the attenuated range and reduces the attenuation effect.

고막이식형 마이크로폰을 위한 이식형 인공중이 적응 피드백 제거기 구현 (An Adaptive Feedback Canceller for Fully Implantable Hearing Device Using Tympanic Membrane Installed Microphone)

  • 김태윤;김명남;조진호
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.189-199
    • /
    • 2016
  • Many implantable hearing aids are being developed as alternatives to conventional hearing aids which has inconveniences for use and social stigma that make hearing-impaired people avoid to wear it. Particularly, the fully-implantable middle ear hearing devices (F-IMEHD) are being actively studied for mixed or sensorineural hearing impaired people. In development of F-IMEHD, the most difficult problem is improving the performance of implantable microphone. Recently, Cho et al. have studied the tympanic membrane installed microphone which has better sensitivity and is easier to operate on patient than the microphone implanted under the skin. But, it may cause howling problem due to the feedback signal via oval window and ossicle chain from the transducer on round window in the middle ear cavity, therefore, a feedback canceller is necessary. In this paper, we designed NLMS (normalized least mean square) adaptive feedback canceller for F-IMEHD with tympanic membrane installed microphone and a transducer implemented at round window, and computer simulation was performed to verify its operation. The designed adaptive feedback canceller has a delay filter, a 64 point FIR fixed filter and a 8-tap adaptive FIR filter. Computer simulation of the feedback path is modeled by using the data obtained through human cadaver experiment.

완전 이식형 인공중이용 적합 소프트웨어의 구현 (Implementation of Fitting Software for Fully Implantable Middle Ear Hearing Device)

  • 이장우;정의성;임형규;이정현;성기웅;김명남;조진호
    • 재활복지공학회논문지
    • /
    • 제3권1호
    • /
    • pp.21-25
    • /
    • 2009
  • 일반적으로 완전 이식형 인공중이는 이식형 마이크로폰과 진동 트랜스듀서를 포함한 모든 구성 요소가 측두골 부근 피부 아래에 이식되는 보청기이다. 마이크로폰과 트랜스듀서의 경우 이식 전과 후의 동작 주파수 특성 등이 달라진다. 이러한 특성변화와 이식 대상자의 청력특성에 알맞은 보청기 동작을 수행하기 위해 적합과정을 수행하게 된다. 일반 공기전도형 보청기나 부분 이식형 보청기의 경우 적합을 위한 전선 연결부가 존재하나 완전이식형의 경우에는 몸속에 모두 이식됨으로 이러한 전선의 연결이 어려우며 이에 따라 기존 보청기의 적합 프로그램을 적용하는 하드웨어를 이용한 적합이 어렵다. 본 논문에서는 완전 이식형 인공중이를 위한 무선 적합 하드웨어에 적용 가능한 적합 소프트웨어를 설계 및 구현하였다. 구현한 적합 소프트웨어는 마이크로폰과 트랜스듀서의 특성과 난청자의 청력도를 반영하여 적절한 청력 보상치를 산출할 수 있다.

  • PDF

골전도를 통한 생체신호가 이식형 마이크로폰에 미치는 영향 및 고찰 (Study and Effects of Bone Conducted Signal on the Implantable Microphone)

  • 우승탁;정의성;김명남;조진호
    • 재활복지공학회논문지
    • /
    • 제4권1호
    • /
    • pp.29-34
    • /
    • 2010
  • 완전 이식형 보청기는 기존 보청기가 가지고 있는 여러 문제점들을 해결하기 위해 연구 개발되고 있다. 이러한 완전이식형 보청기에 사용되는 이식형 마이크로폰은 일반적으로 측두부의 피부아래 이식된다. 그런데 이식된 마이크로폰의 특성은 음식을 먹거나 치아의 마찰, 생체동잡음에 의해 영향을 받을 수 있다. 본 논문에서는 이식된 마이크로폰에 골전도를 통해 전달된 생체잡음신호가 미치는 영향을 조사하기 위하여, 사람의 측두부 및 피부의 특성이 유사한 물리모델을 제작하여, 이식된 마이크로폰의 감도측정실험을 수행하였다. 1 kHz의 순음신호를 이식된 마이크로폰에 인가하고, 동시에 여러 주파수대의 정현파진동을 인공뼈에 인가하여 측정되었다. 그 결과 마이크로폰의 출력은 골전도를 통한 신호의 영향을 받아 왜곡될 수 있으며, 그 영향은 주파수대역에 따라 달라짐을 확인하였다.