• 제목/요약/키워드: full-scale section

검색결과 158건 처리시간 0.026초

Study on the progressive collapse resistance of CP-FBSP connections in L-CFST frame structure

  • Xiong, Qingqing;Wu, Wenbo;Zhang, Wang;Chen, Zhihua;Liu, Hongbo;Su, Tiancheng
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.437-450
    • /
    • 2022
  • When the vertical load-bearing members in high-rise structures fail locally, the beam-column joints play an important role in the redistribution of the internal forces. In this paper, a static laboratory test of three full-scale flush flange beam-reinforced connections with side and cover plates (CP-FBSP connection) with double half-span steel beams and single L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) was conducted. The influence of the side plate width and cover plate thickness on the progressive collapse resistance of the substructure was thoroughly analyzed. The failure mode, vertical force-displacement curves, strain variation, reaction force of the pin support and development of internal force in the section with the assumed plastic hinge were discussed. Then, through the verified finite element model, the corresponding analyses of the thickness and length of the side plates, the connecting length between the steel beam flange and cover plate, and the vertical-force eccentricity were carried out. The results show that the failure of all the specimens occurred through the cracking of the beam flange or the cover plate, and the beam chord rotations measured by the test were all greater than 0.085 rad. Increasing the length, thickness and width of the side plates slightly reduced the progressive collapse resistance of the substructures. The vertical-force eccentricity along the beam length reduced the progressive collapse resistance of the substructure. An increase in the connecting length between the beam flange and cover plate can significantly improve the progressive collapse resistance of substructures.

상부 슬래브와 합성된 원심성형으로 제작된 초고강도 각형보의 실험연구 (The Experimental Study of Full-scale Centrifugal Formed High Strength Concrete Prismatic Beam(CFPB) Composited with Deck Slab )

  • 이두성;김성진;김정회
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권1호
    • /
    • pp.19-29
    • /
    • 2023
  • 실리카 흄과 같은 고가의 혼화재 투입 없이 원심성형 공정 활용으로 콘크리트의 수밀성 증대 통한 콘크리트 압축강도 100 MPa급 초고강도 프리스트레스 각형보를 개발하였다. 벽체에 가설된 초고강도 원심성형 각형보는 상부슬래브 콘크리트와 합성된 후에 공용하중을 받게 되는데, 원심성형 보와 바닥판 사이에는 휨에 의해 수평전단응력이 발생되고 이는 스터드나 철근 등의 전단연결재를 통해서 보와 바닥판이 합성거동을 하게 된다. 본 연구에서는 공장에서 생산된 100 MPa급 원심성형 각형보 상부에 RC슬래브를 제작하여 합성시킨 실물모형 시험체에 대한 휨재하시험을 수행하였으며, 합성단면은 설계 공칭휨강도를 넘어 안정적인 합성거동을 하면서 파괴되어 구조적인 신뢰성을 입증하였다.

Identification of acrosswind load effects on tall slender structures

  • Jae-Seung Hwang;Dae-Kun Kwon;Jungtae Noh;Ahsan Kareem
    • Wind and Structures
    • /
    • 제36권4호
    • /
    • pp.221-236
    • /
    • 2023
  • The lateral component of turbulence and the vortices shed in the wake of a structure result in introducing dynamic wind load in the acrosswind direction and the resulting level of motion is typically larger than the corresponding alongwind motion for a dynamically sensitive structure. The underlying source mechanisms of the acrosswind load may be classified into motion-induced, buffeting, and Strouhal components. This study proposes a frequency domain framework to decompose the overall load into these components based on output-only measurements from wind tunnel experiments or full-scale measurements. First, the total acrosswind load is identified based on measured acceleration response by solving the inverse problem using the Kalman filter technique. The decomposition of the combined load is then performed by modeling each load component in terms of a Bayesian filtering scheme. More specifically, the decomposition and the estimation of the model parameters are accomplished using the unscented Kalman filter in the frequency domain. An aeroelastic wind tunnel experiment involving a tall circular cylinder was carried out for the validation of the proposed framework. The contribution of each load component to the acrosswind response is assessed by re-analyzing the system with the decomposed components. Through comparison of the measured and the re-analyzed response, it is demonstrated that the proposed framework effectively decomposes the total acrosswind load into components and sheds light on the overall underlying mechanism of the acrosswind load and attendant structural response. The delineation of these load components and their subsequent modeling and control may become increasingly important as tall slender buildings of the prismatic cross-section that are highly sensitive to the acrosswind load effects are increasingly being built in major metropolises.

Clinical and patient-reported outcomes after recession coverage using modified vestibular incision subperiosteal tunnel access with a volume-stable collagen matrix as compared to a coronally advanced flap with a subepithelial connective tissue graft

  • Chun-Teh Lee;Marlena Lange;Alain Jureidini;Nurit Bittner;Ulrike Schulze-Spate
    • Journal of Periodontal and Implant Science
    • /
    • 제52권6호
    • /
    • pp.466-478
    • /
    • 2022
  • Purpose: Coronally advanced split-or full-thickness (CAST or CAFT) flaps in combination with subepithelial connective tissue grafts (SCTGs) are commonly used in root-coverage procedures despite postoperative pain and bleeding from the graft donor site. Therefore, the modified vestibular incision subperiosteal tunnel access procedure (VISTAX) uses a novel collagen matrix (VCMX) instead of autogenous tissue to address the limitations associated with autogenous tissue grafting. This retrospective study compared the clinical outcomes of VISTAX to the results obtained after using a CAST or CAFT flap in combination with SCTG for root coverage. Methods: Patients with single or multiple adjacent recession I/II defects were included, with 10 subjects each in the VISTAX, CAFT, and CAST groups. Defect coverage, keratinized tissue width, esthetic scores, and patients' perceived pain and dentinal hypersensitivity (visual analogue scale [VAS]) were assessed at baseline, 3 months, and 6 months. Results: All surgical techniques significantly reduced gingival recession (P<0.0001). Defect coverage, esthetic appearance, and the reduction in dentinal hypersensitivity were comparable. However, the VAS scores for pain were significantly lower in the VISTAX group than in the CAFT and CAST groups, which had similar scores (P<0.05). Furthermore, the clinical results of VISTAX and CAFT/CAST generally remained stable at 6 months. Conclusions: The clinical outcomes of VISTAX, CAFT, and CAST were comparable. However, patients perceived significantly less pain after VISTAX, indicating a potentially higher patient acceptance of the procedure. A prospective trial with a longer follow-up period and a larger sample size should therefore evaluate VISTAX further.

SN 강재가 사용된 강구조 용접모멘트접합부의 내진성능 평가 (Evaluating Seismic Performance of Steel Welded Moment Connections Fabricated with SN Steel)

  • 오상훈;최영재;윤성기;이동규
    • 한국강구조학회 논문집
    • /
    • 제22권3호
    • /
    • pp.271-280
    • /
    • 2010
  • 본 연구에서는 국내 건축 구조용 강재인 SN490 강재를 사용하여 실물 크기의 H형강 보와 기둥으로 구성된 모멘트저항골조의 외부 T자형 용접모멘트접합부를 대상으로 실험을 계획하였다. 실험변수를 용접접근공형상, 접합부 이음 방식, RBS(Reduced Beam section)로 하여 9개의 시험체를 제작하였고, 반복재하 실물대 실험을 수행하였다. 실험에 따른 각 시험체의 파괴형태 및 모멘트-층간변위 관계, 변형률 분포를 나타내었으며, 재료인장 실험을 통하여 실험에 사용된 시험체의 전소성모멘트를 구한 다음 특수모멘트 접합부에 해당하는 시험체를 분류하였다. 각 시험체의 모멘트-층간변위 곡선을 골격곡선과 바우싱거곡선으로 분리하여 내력상승률, 소성배율, 에너지 소산량 등을 나타내었으며 이를 가지고 각 시험체의 소성변형능력을 평가하였다. 실험결과 용접접근공이 제거된 시험체가 기존 용접접근공형상을 가지는 시험체에 비하여 우수한 내진성능을 나타내었고, 보 웨브를 용접과 볼트를 병행하고 전단탭을 전체에 걸쳐 보강 용접한 시험체가 가장 우수한 내진성능을 나타내었다.

차분 진화 알고리즘 기반의 SI기법을 이용한 외부 긴장된 텐던의 장력추정 (Tensile Force Estimation of Externally Prestressed Tendon Using SI technique Based on Differential Evolutionary Algorithm)

  • 노명현;장한택;이상열;박대효
    • 대한토목학회논문집
    • /
    • 제29권1A호
    • /
    • pp.9-18
    • /
    • 2009
  • 본 논문은 외부 긴장된 텐던의 장력추정에 대한 차분진화기법의 적용을 소개한다. 제안된 차분진화 알고리즘의 SI기법은 기존의 구배 기반의 최적화 기법과는 다르게 전역해 탐색이 가능하다. 수치실험은 인식변수에 대한 사전정보 없이도, 제안된 차분진화기법이 외부긴장 텐던의 정확한 장력 추정뿐 아니라 유효공칭직경 추정이 가능하여 1%미만의 추정 오차를 갖는 유용한 기법임을 보여준다. 또한 긴장력 손실 유무의 사용 상태를 고려한 축소실험 모델 실험을 이용하여 제안된 기법의 타당성이 실험적으로 검증되었다. 실험의 결과는 긴장력 손실과 무관하게 정확한 장력 추정과 유효공칭직경의 추정뿐 아니라 실험 모델의 감쇠비까지 추정되어 제안된 기법이 적합하고, 효과적인 방법임을 보여준다. 유효공칭 직경의 2% 추정 오차는 실제 꼬여진 단면을 갖는 텐던의 직경과 충실단면을 갖는 FE 모델의 직경의 차이 때문이다. 마지막으로, 기존이론과의 비교 분석으로 제안된 차분진화 기법의 정확성과 우월성이 검증되었다.

단면회전방법을 적용한 강합성 소수주거더 개발 및 실험적 성능 평가 (Development and Experimental Performance Evaluation of Steel Composite Girder by Turn Over Process)

  • 김성재;이나현;김성배;김장호
    • 대한토목학회논문집
    • /
    • 제30권5A호
    • /
    • pp.407-415
    • /
    • 2010
  • 현재 국내에서 설계되고 있는 40~70 m 지간의 강도로교 90% 이상이 박스거더교 형식이며 박스거더교는 휨 강성과 비틀림 강성이 뛰어나 장경간이나 곡선을 갖는 교량 형식으로 적합할 뿐만 아니라 가설현장에서의 작업을 최소화 할 수 있어 현장 안전관리 면에서도 유리한 구조형식이다. 그러나 박스거더는 상하 플랜지와 복부판이 수직, 수평보강재로 보강되는 구조로 부재량과 용접량이 많이 소요되어 비경제적인 교량 형식으로 많이 지적되어 왔다. 따라서, 미국이나 일본에서는 상대적으로 부부재를 줄일 수 있는 보다 경제적인 플레이트거더교가 일반적으로 적용되고 있다. 이러한 플레이트거더교의 한 형식인 소수주거더교는 강합성교량의 합리화를 위해 많이 채용되는 형식으로, 주거더 간격을 종래의 3 m 정도에서 2배 정도인 6 m 이상으로 증가하여 주거더의 개수를 최소화시키는 경제적인 교량형식이다. 또한, 거더 단면의 단순화를 위하여 거더의 복부판에 부착되는 수평보강재와 수직보강재를 최대한 생략할 수 있다. 2주거더교는 소수주거더교의 대표적인 형식으로, 유효폭 10 m 전후의 교량에 적합하여 프랑스를 중심으로 유럽에서는 1960년대부터 본격적으로 개발되어왔다. 국내에서는 소수주거더교 적용시 안전율 확보를 위해 유럽이나 일본 등에 비해 많은 강재량을 사용하고 있으며, 설계자들의 친밀도 부족과 박스거더교에 비해 복잡한 설계 등과 같은 여러가지 실무적용 차원에서 적용이 제한되고 있는 실정이다. 이 연구에서는 합리화 강교량 형식인 소수주거더교의 제작방법을 개선하고 구속콘크리트를 활용하여 강교량에서 공사비와 직결되는 강중을 줄일 수 있는 신형식 강합성거더(Turn Over Composite Girder) 구조형식을 제안하고자 한다. 또한 실물 크기인 20 m 단면회전방법을 적용한 강합성 거더시험체 및 교량시험체를 제작하여 제작성을 평가하고 구조성능 실험을 하여 구조안전성을 평가하였다.

콘크리트 채움 U형 메가 합성보의 내진성능 평가 (Seismic Performance Evaluation of Concrete-filled U-shaped Mega Composite Beams)

  • 이철호;안재권;김대경;박지훈;이승환
    • 한국강구조학회 논문집
    • /
    • 제29권2호
    • /
    • pp.111-122
    • /
    • 2017
  • 본 연구에서는 1900mm급의 춤이 깊은 콘크리트 채움 U형 메가 합성보의 합성보통모멘트골조에 대한 적용성을 검토하였다. 대형 합성보의 실물대 내진성능실험에 대한 현실적 제약으로 인하여 작은 규모의 실험체에 대해 수행된 기존 실험결과의 분석과 수치해석연구의 보완을 통해 연구를 수행하였다. 이러한 형태의 합성보는 부모멘트 작용시의 웨브국부좌굴이 가장 중요하므로 선행 실물대 실험결과로부터 웨브의 판폭두께비와 층간변형능력 사이의 관계를 분석하였다. 그 결과, 25mm 두께의 U형 강재단면을 지닌 1900mm급의 대형 합성보라 하더라도 층간변위각 2% 이후 웨브국부좌굴을 경험하고 3% 이후 최대변형에 도달하는 것으로 확인되었다. 이는 합성보통모멘트골조의 요구조건을 상회하는 것으로 AISC 기준에 따른 웨브 판폭두께비 제한이 본 연구의 U형 단면에는 보수적임을 시사하기도 한다. 유한요소해석을 통해서는 합성보의 휨성능 및 웨브국부좌굴에 대한 수평스티프너의 영향을 분석하였다. 대형 합성보는 스티프너 보강과 관련없이 부모멘트 방향으로 공칭소성모멘트 이상의 휨성능을 발휘하였으며, 스티프너를 보강할 경우에는 웨브국부좌굴이 상당히 지연되는 긍정적인 효과가 있었다. 이상의 실험결과 분석 및 해석연구에 의하면 1900mm급의 춤이 깊은 콘크리트 채움 U형 메가 합성보는 합성보통모멘트골조에 보수적으로 적용가능한 것으로 판단된다.

새로운 날개단면을 이용한 KD-프로펠러 씨리즈 개발 (Development of KD- Propeller Series using a New Blade Section)

  • 이진태;김문찬;안종우;김호충
    • 대한조선학회논문집
    • /
    • 제28권2호
    • /
    • pp.52-68
    • /
    • 1991
  • 캐비테이션 특성이 우수하고 넓은 받음각에서 양력-향력비가 큰 새로운 날개단면(KH18 단면)을 사용하여 체계적인 방법으로 기하학적 형상을 변화시켜 설계된 새로운 계열 프로펠러의 개발을 시도하였다. 새로운 계열 프로펠러의 형상을 설계함에 있어 기존의 계열 프로펠러와는 달리 선택된 반류분포의 회전방향 평균 반류분포를 입력자료로 하여 반경방향 부하분포와 코오드 방향 부하분포를 동일하게 유지하면서 피치 및 캠버의 형상을 결정하였다. 또한 코오드 길이, 두께, 스큐 및 레이크 분포와 같은 형상은 최근 실적선 프로펠러의 형상 특성을 정형화하여 선택되었기 때문에 초기설계시 설계된 형상이 최종 설계 프로펠러의 형상과 크게 다르지 않을 것으로 생각되어 초기성능을 보다 정확하게 추정할 수 있게 하였다. 설계된 계열 프로펠러는 날개수 4개인 프로펠러를 대상으로 날개 전개면적비 4개($A_{E}/A_{O}$=0.3, 0.45, 0.6, 0.75)에 대하여 각 전개면적비에서 평균피치비를 5개(P/D=0.5, 0.65, 0.8, 0.95, 1.1)로 변화시켜 총 20개의 프로펠러로 구성되었으며 KD-프로펠러 씨리즈(KRISO-DAEWOO Propeller Series)라 명명하였다. 설계된 계열 프로펠러들에 대하여 단독특성시험, 캐비테이션 관찰시험, 변동압력 계측시험을 수행하였다. 프로펠러 단독특성 시험결과의 회귀해석결과로 부터 $B_{P}-\delta$ 곡선을 도출하여 초기설계 단계에서 최적 프로펠러 직경등을 쉽게 결정할 수 있게 하였다. 기준으로 선택된 반류분포(2700TEU 콘테이너선의 반류) 후류에서 프로펠러 추력계수 및 캐비테이션 수를 체계적으로 변화시킨 상태에서 캐비테이션 관찰시험 및 변동압력계측시험을 수행하였다. 양력면이론에 의한 비정상 프로펠러 성능해석에 의해 계산된 최대 국부양력계수 ($C^{max}_{l,0.8R}$)와 국부캐비테이션 수(${\sigma}_0=\frac{p-p_v}{\frac{1}{2}{\rho}V^2_{0.8R}}$)를 기준으로 캐비테이션 관찰시험 결과를 정리하여 KD-캐비테이션 챠트를 도출하였다. 기존의 캐비테이션 챠트는 균일류중의 시험 결과를 정리하여 작성되었으나 KD-캐비테이션 챠트는 반류분포중에서 시험된 프로펠러 관찰시험 결과로 부터 도출되었으므로 초기설계 단계에서 보다 정확한 캐비테이션 발생량 추정이 가능하리라 예상된다.

  • PDF

전단접합 및 리브 플레이트로 보강한 H형 보-기둥 접합부의 내진성능에 관한 실험적 연구 (An Experimental Study on the Seismic Performance of Shear Connections and Rib Plate H Beam to Column Connections)

  • 오경현;서성연;김성용;양영성;김규석
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.569-580
    • /
    • 2005
  • 기존 강구조 모멘트연성골조시스템의 기둥-보 접합부는 노스리지 지진과 고베 지진시 충분한 내진성능을 발휘하지 못하고 접합부에서 취성파괴가 발생하였다. 본 논문은 기존 접합부의 형상을 변화하여 H형강보 웨브의 고장력볼트 전단접합과 H형 플랜지의 리브보강 유무를 변수로 한 실대형 실험을 실시하였다. 실험목적은 보웨브의 2면전단접합으로 고장력 볼트수 감소와 시공성 향상을 기대하며, 리브플레이트 보강을 통해 내진성능을 향상시키고자 한다. H형강 보웨브의 2면전단접합과 리브플레이트로 보강한 접합부 실험결과, 기존 접합부보다 초기강성, 에너지 소산능력 및 소성회전능력이 높게 나타났으며, 내력상승률 및 변형능력은 전단탭의 위치로 인해 인장측과 압축측이 다소 차이를 보이고 있으나 전체적으로 우수한 내진성능을 나타냈다. 그리고 모든 시험체가 층간변위비 4%, 총소성회능력 약 0.029rad이상 및 접합부 최대내력이 원단면보 전소성모멘트의 약 130% 이상을 상회하여 중급모멘트연성골조이상의 설계가 가능하리라 사료된다.