• 제목/요약/키워드: full-mode

검색결과 882건 처리시간 0.022초

A Comparative Study of Simple Ac-Dc PWM Full-Bridge Current-Fed and Voltage-Fed Converters

  • Moschopoulos Gerry;Shah Jayesh
    • Journal of Power Electronics
    • /
    • 제4권4호
    • /
    • pp.246-255
    • /
    • 2004
  • Ac-dc PWM single-stage converters that integrate the PFC and dc-dc conversion functions in a single switching converter have been proposed to try to minimize the cost and complexity associated with implementing two separate and independent switch-mode converters. In this paper, two simple ac-dc single-stage PWM full-bridge converters are considered - one current-fed, the other voltage-fed. The operation of both converters is explained and their properties are noted. Experimental results obtained from simple lab prototypes of both converters are presented, then compared and discussed.

정확한 Full-Wave 해석방법을 이용한 자동모드 급전을 가지는 PCB Power-Distribution Network에서의 슬릿에 의한 영향 연구 (On the Effects of the Slits in the PCB Power-Distribution Network with the Differential-Mode Signaling using a Rigorous Full-Wave Method)

  • 강승택;주정호;장건호;김상훈;임동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.130-131
    • /
    • 2007
  • This study investigates the performances of the signaling techniques including differential signals for the power-distribution network(PDN)s with and without the slit, using a rigorous evaluation method, validated by the FDTD simulation up to 5 GHz.

  • PDF

Performance Improvement for Device-to-Device (D2D) Users in Underlay Cellular Communication Networks

  • Bin Zhong ;Hehong Lin;Liang Chen ;Zhongshan Zhang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제18권9호
    • /
    • pp.2805-2817
    • /
    • 2024
  • This study focuses on the performance of device-to-device (D2D) communications in underlay cellular networks by analyzing key metrics such as successful transmission probability, coverage probability, and throughput. Under the homogeneous Poisson point process (PPP) spatial distribution of full-duplex (FD)-D2D users in cellular networks, stochastic geometry tools are used to derive approximate expressions for D2D users' coverage probability and throughput. In comparison to the conventional half-duplex (HD) communication mode, when the self-interference cancellation factor β reaches -95 dB, there is a substantial improvement in the throughput of FD-D2D users, nearly doubling their gain. Additionally, experimental results demonstrate that the Newton iterative algorithm can be used to optimize the targeted signal-to-interference-plus-noise-ratio (SINR) threshold of users within the range of (10, 20) dB.

주철근 겹침이음된 휨-전단 RC교각의 실물모형 준정적 실험 (Quasi Static Test of Lap Spliced Shear-Flexure RC Piers Using Real Scale Models)

  • 곽임종;조창백;조정래;김영진;김병석
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.203-210
    • /
    • 2002
  • The past bridge design specifications of Korea didn't include 1imitation on the amount of lap splices in the plastic hinge zone of piers, and so do current specifications. But these specifications include just limitation on the minimal length of lap splices. Thus, a large majority of non-seismically designed bridge piers may have lap splices in plastic hinge zone. In this study, model pier was selected among existent bridge piers whose failure mode is complex shear-flexure mode. Full scaled RC pier models whose aspect ratio is about 2.67 were constructed and quasi static test according to the drift level history was implemented. From the test results, effect of the lap splices on the seismic performance of bridges piers was analyzed, and the seismic capacity of the model bridges was evaluated by capacity spectrum method.

  • PDF

원통형 배열 구조물의 접수진동 해석 (Vibration Analysis of Water-loaded Cylindrical Array Structures)

  • 신창주;홍진숙;정의봉;서희선
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.175-182
    • /
    • 2009
  • This paper summarizes a solution procedure for a large cylindrical structure mounted underneath a ship as a sonar. Vibration analysis of the water loaded structure is required to enhance the structural reliability as well as acoustic performance of the sonar. It is, however, often very difficult to solve such structures since they have many DOFs, considering the frequency of interest and the water-loading. The mode mapping method is proposed and verified to take into account the water-loading with the minimum DOF for the analysis. The cyclic symmetric method is then reviewed to show how the eigen properties of the full model can be obtained from the representative segment model. The solution procedure is finally proposed and applied successfully for a simplified water-loaded cylindrical array structure.

주기대칭법을 이용한 원통형 배열 구조물의 접수진동 해석 (Vibration Analysis of Waterloaded Cylindrical Aarray Structures)

  • 신창주;홍진숙;정의봉;서희선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1054-1059
    • /
    • 2007
  • This paper summarized a solution procedure for a large cylindrical structure mounted underneath a ship as a sonar. Vibration analysis of the water loaded structure is required to enhance the structural reliability as well as acoustic performance of the sonar. It is, however, often very difficult to solve such structures since they have many DOFs, considering the frequency of interest and the waterloading. The cyclic symmetric method is firstly reviewed to show how the eigen properties of the full model can be obtained from the representative segment model. The mode mapping method is then proposed and verified to take into account the waterloading with the minimum DOF for the analysis. The solution procedure is finally proposed and applied for a waterloaded cylindrical array structure.

  • PDF

실물 및 축소모형 비교실험을 통한 휨-전단 RC교각의 내진성능평가 (Seismic Performance Evaluation of Shear-Flexure RC Piers through Comparative test of Real Scale and Reduced Scale Model)

  • 곽임종;조창백;조정래;김영진;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.849-854
    • /
    • 2002
  • From the analysis results of some as-built drawings in national roadway bridges in Korea, many bridge piers are expected to show complex shear-flexural behaviour under earthquakes. But the previous research works about the seismic evaluation of bridges considered flexural behaviour RC piers only. In addition, the past bridge design specifications in Korea didn't include limitation on the amount of longitudinal lap splices in the plastic hinge zone of piers. Thus a large majority of non-seismically designed bridge piers in Korea may have lap splices in plastic hinge zone. In this study, prototype pier was selected among existent bridge piers whose failure mode is expected to be complex shear-flexural mode. And then, full scale and 1/2 reduced scale model RC piers with various longitudinal lap splice details were constructed. From the quasi static test results on these model RC piers, the effect of longitudinal lap splices on the seismic performance of bridges piers was analyzed. And the seismic capacity of the non-seismically designed shear-flexural RC piers was evaluated.

  • PDF

Controller Design and By-Pass Structure for the Two-Stage Grid-Connected Photovoltaic Power Conditioning System

  • 이성준;배현수;조보형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.206-208
    • /
    • 2009
  • In this paper, a systematical controller design method for a twostage grid-connected photovoltaic power conditioning system is proposed. For a pre-stage boost converter to achieve the stable operation in the entire region of solar array, the digital resistive current mode controller is used. This algorithm is very simple to implement with a digital controller and there is no power stage parameter dependency in the controller design. For a post-stage single-phase full-bridge inverter, a PI controller with a feedforward compensation for the inner current control is employed. Furthermore, in case that the operating point of the solar array under varying environmental conditions is higher than the required voltage for the inverter current control, the bypass mode for the boost converter is possible for the more efficient operation. The proposed control scheme is validated through the experiment of the prototype two-stage power conditioning system hardware with a 200W solar array.

  • PDF

급속 충전 시스템을 위한 DC-bias Pulse 충전 방식의 특성 연구 (The Characteristics Analysis of DC-Bias Pulse Method Charge for Fast Charging System)

  • 반충환;이영진;권완성;한동화;변병주;은종목;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.218-219
    • /
    • 2011
  • In this paper Li-polyer batteries, which are in use of EV recently, are used. The Li-polymer batteries have high density of energy and invulnerability of the fluids and explosion. It is confirmed that the DC-bias pulse mode/cc mode characteristics on charge by designing Fast-charging system designed in three phase PWM and full-bridge converter.

  • PDF

이중용량 왕복동 압축기 신뢰성 확보에 대한 연구 (A Study on the Reliability of a Dual Capacity Reciprocating Compressor)

  • 김종봉
    • 한국정밀공학회지
    • /
    • 제26권7호
    • /
    • pp.81-90
    • /
    • 2009
  • Due to environmental issues, the development of low energy consumption products has become one of the main topics in the home appliance industry. The energy consumption of a refrigerator depends on the efficiency of its compressor as well as on the refrigerator cycle design, such as the capacity modulation. In this study, a dual capacity, i.e., two-step capacity modulation (TCM), reciprocating compressor is developed. In a TCM compressor, capacity modulation is achieved by changing the dead volume in the cylinder. Instead of a concentric sleeve, an eccentric sleeve, a key, and a spring are used to change the dead volume for the clockwise and counterclockwise rotation of a motor. When the compressor changes its operating mode from full capacity to partial capacity or in opposite direction, the key may collide with the eccentric sleeve. The structural reliability and mode change reliability were confirmed by analysis and experiment.