• Title/Summary/Keyword: full feedback

Search Result 277, Processing Time 0.036 seconds

Human Postural Response to Linear Perturbation (선형외란에 대응하는 인체의 자세응답 해석)

  • Kim, Se-Young;Park, Su-Kyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • Human postural responses appeared to have stereotyped modality, such as ankle mode, knee mode and hip mode in response to various perturbations. We examined whether human postural control gain of full-state feedback could be decoupled along with the eigenvector. To verify the model, postural responses subjected to fast backward perturbation were used. Upright posture was modeled as 3-segment inverted pendulum incorporated with feedback control, and joint torques were calculated using inverse dynamics. Postural modalities such as ankle, knee and hip mode were obtained from eigenvectors of biomechanical model. As oppose to the full-state feedback control, independent eigenvector control assumes that modal control input is determined by the linear combination of corresponding modality. We used optimization method to obtain and compare the feedback gains for both independent eigenvector control and full-state feedback control. As a result, we found that simulation result of eigenvector feedback was not competitive in comparison with that of full-state feedback control. This implies that the CNS would make use of full-state body information to generate compensative joint torques.

Seismic test of modal control with direct output feedback for building structures

  • Lu, Lyan-Ywan
    • Structural Engineering and Mechanics
    • /
    • v.12 no.6
    • /
    • pp.633-656
    • /
    • 2001
  • In this paper, modal control with direct output feedback is formulated in a systematic manner for easy implementation. Its application to the seismic protection of structural systems is verified by a shaking table test, which involves a full-scale building model and an active bracing system as the control device. Two modal control cases, namely, one full-state feedback and one direct output feedback control were tested and compared. The experimental result shows that in mitigating the seismic response of building structures, modal control with direct output feedback can be as effective and efficient as that with full-state feedback control. For practical concerns, the control performance of the proposed method in the presence of sensor noise and stiffness modeling error was also investigated. The numerical result shows that although the control force may be increased, the maximum floor displacements of the controlled structure are very insensitive to sensor noise and modeling error.

Output feedback, decentralized controller design for an active suspension system using 7 DOF full car model (7 자유도 차량 모델과 출력 되먹임을 이용한 자동차 능동 현가장치 설계에 관한 연구)

  • 노태수;정길도;홍동표
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.871-875
    • /
    • 1996
  • The Output feedback linear quadratic regulator control is applied to the design of active suspension system using 7 DOF full car model. The performance index reflects the vehicle vertical movement, pitch and roll motion, and minimization of suspension stroke displacements in the rattle space. The elements of gain matrix are approximately decoupled so that each suspension requires only local information to generate the control force. The simulation results indicates that the output feedback LQ controller is more effective than purely passive or full state feedback active LQ controllers in following the road profile at the low frequency range and suppressing the road disturbance at the high frequency ranges.

  • PDF

Decentralized Supervision with Coordinator of Discrete Event Systems (Coordinator를 이용한 이산사건시스템의 분산관리제어)

  • 김성규;임종태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.35-35
    • /
    • 2000
  • In this paper, we introduce a conservative control approach using a full feedback map and suggest a switching control between the conservative and default control. For the conservative control, we use the coordinator which performs the conjunction operation of the full feedback map information of local supervisors. Since the switching control with the coordinator extends the ability of local supervisors in the decentralized supervisory control, we can solve the problem in case the coobservability condition can not be satisfied.

  • PDF

Closed Loop Quasi- Orthogonal ST8C with Antenna Selective Feedback (안테나 선택적 Feedback을 갖는 폐루프 준직교 STBC)

  • 김민수;김용석;황금찬
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04a
    • /
    • pp.511-513
    • /
    • 2004
  • IMT-2000 시스템에서 직교 STBC (Space-Time Block Code)와 같은 송신 다이버시티(diversity) 기법은 순방향 링크용량을 향상시킬 수 있다. 그러나 완벽한 다이버시티 (full diversity) 이득과 코드율 1 (full code rate)을 갖는 직교 STBC는 송신안테나 개수가 2개일 경우만 존재한다. 이 논문에서는 4개의 송신안테나와 1개의 수신안테나를 갖는 시스템에서 코드율 1 을 갖는 준직교 STBC를 사용할 경우 안테나 선택적 feedback 정보를 이용하여 완벽한 다이버시티 이득을 얻는 동시에 feedback 정보량은 줄일 수 있음을 보여 준다.

  • PDF

A Study on the Active Noise Control in Duct (닥트내 소음의 능동제어에 관한 연구)

  • Lee Chai-Bong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.3
    • /
    • pp.130-135
    • /
    • 2006
  • There have been experiments dealing with the possibility of the actualization of the ANC system by means of operating the DSP adaptation filter. This filter is composed of various filters(including X-LMS algorithm, Filter-U algorithm, and Full-Feedback-Filter-U algorithm) that use ventilation fans and loudspeakers as a primary source in a circular duct as an experimental device. In this operation, the ANC system using the X - LMS algorithm was found to be more effective in reducing noise than without such system. When applying the input signal of the DSP board Full Feedback-Filtered-U algorithm system while having in mind that the additionally installed second control signal was gone through feedback and mixed into the detection microphone installed near the ventilation fan when using the first ventilation fan, the system was not emitted, but maintained stable during the operation of the control filter. At this point, noise tended to decrease at a maximum of l0dB compared to other algorithms at the frequency band of 170-250Hz.

  • PDF

Gain Design of an Adaptive Full-order Observer Using a Pole Placement Technique for Speed Sensorless Induction Motor Drives

  • Yoo, Anno;Han, Sang-Heon;Son, Young Ik;Yoon, Young-Doo;Hong, Chanook
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1346-1354
    • /
    • 2016
  • This paper proposes a design guideline for the feedback gain of the adaptive full-order observer in the speed sensorless control of induction machines. The performance of the adaptive full-order observer is dependent on its feedback gain. This paper presents a pole placement method for the observer feedback gain design to improve the estimation performance of the speed adaptive observer. In the proposed method, the observer poles can be chosen independently of the induction motor poles. Instead, they can be positioned according to the operating speed. An analysis and experimental results obtained with the proposed method reveals better performances under general operating conditions.

Enhancing performance of full-text retrieval systems using relevance feedback (적합성피이드백을 이용한 전문검색시스템의 검색효율성 증진을 위한 연구)

  • 문성빈
    • Journal of the Korean Society for information Management
    • /
    • v.10 no.2
    • /
    • pp.43-67
    • /
    • 1993
  • The primary purpose of the study is to improve the low preclslon often found In full-text retrleval systems. In order to enhance the low precision of full-text retrleval wh~le retaining ~ t s hgh recall, relevance feedback mechanisms based on probabilistic retrieval models (binary independence and two-Polsson Independence models) were employed. Thls paper investigates the effect of relevance feedback on the performance of full-text retrieval systems.

  • PDF

Comparative Evaluation of Sky-Hook Controllers for a Full Car Model with Active or Semi-Active Suspension Systems (능동과 반능동 현가장치로 된 전차량 모델에 대한 스카이훅 제어기의 비교 평가)

  • Yun, Il-Jung;Im, Jae-Pil
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.7
    • /
    • pp.614-621
    • /
    • 2001
  • The controllers for a full car 7-DOF model with 4 active or semi-active suspension units are designed and evaluated in this research. The control algorithms for suspension systems, such as full state feedback active, full state feedback semi-active, sky-hook active, sky-hook semi-actvie, and on-off suspension systems, are analyzed and evaluated with respect to ride comfort. The vehicle dynamic performances are expressed by response curves to a bump input, performance indices for asphalt road input, and frequency characteristic curves. Heaving, rolling, and pitching inputs are applied to the vehicle dynamic system to evaluate frequency characteristics. The simulation results show that the ride quality of the sky-hook controller approaches that the full state feedback controller more closely in semi-active suspension system than in active suspension system. For the implementation of a vehicle with sky-hook suspension control systems in this paper, 7 velocity sensors are required to measure the states.

  • PDF

Characteristics of the Feedback Type Center-Tapped Full Wave Magnetic Amplifier (궤환형 중간 단자 전파형 자기증폭기의 특성)

  • Chang Yub Park
    • 전기의세계
    • /
    • v.13 no.4
    • /
    • pp.25-29
    • /
    • 1964
  • This paper shows that higher amplification can be achieved by applying load current on the internal feedback winding of the magnetic amplifier under test. Since the magnetic flux of the control winding and internal feedback winding saturate the core more fully, the permeability tends to zero and load current increases to the value more than that of ordinary magnetic amplifier without feedback.

  • PDF