• Title/Summary/Keyword: full bond

Search Result 186, Processing Time 0.029 seconds

The Evaluation of the Preservative Treated Plywood Produced by Factory Processing (야외사용을 목적으로 공장라인에서 생산한 방부합판의 성능평가)

  • Son, Dong Won;Lee, Sang-Min;Lee, Dong-heub;Kang, Eun-Chang;Park, Byung Su
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.47-54
    • /
    • 2008
  • To make up original defects of the wooden materials for decks, and to supply the wooden material for outdoor, we fabricated preservative treated plywood(PTP). Copper azole (CUAZ-1) preservative was treated with a normal full-cell process. Bond Strength of PTP was not affected after the preservative treatment. The anti-fungal efficiency and dimensional stability were obtained from PTP. A little discoloration of the surface was detected, but the dimensional change or peel bonded area off were not observed after accelerated weathering test. Although some strength of PTP was reduced after 17 months of field exposure, the PTP should be applicable for outdoor applications.

Crystal Structure of Penicillin V Potassium Salt

  • Kim, Whan-Chul;Yi, Seung-Ho;Shin, Jung-Mi;Yoon, Tae-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.6
    • /
    • pp.713-717
    • /
    • 1993
  • The crystal structure of the potassium salt of penicillin V has been studied by the X-ray crystallographic methods. Crystal data are as follows; potassium 3,3-dimethyl-7-oxo-6-phenoxyacetoamido-4-thia-1- azabicyclo[3.2.0]-heptane-2${\alpha}$-carboxylate, $K^+{\cdot}C_{16}H_{18}N_2O_5S^-$, $M_r$= 388.5, triclinic, Pl, a= 9.371 (1), b= 12.497 (2), c= 15.313 (2) ${\AA},\;{\alpha}= 93.74\;(2),\;{\beta}=99.32\;(1),\;{\gamma}=90.17\;(1)^{\circ},\;V=1765.7\;(2)\;{\AA}^3$, Z=4, $D_m=1.461\;gcm^{-1},\;{\lambda}(Cu\;K{\alpha})=1.5418\;{\AA},\;{\mu}=40.1\;cm^{-1}$, F(000)=808, T=296 K. The structure was solved by the heavy atom and difference Fourier methods with intensity data measured on an automated four-circle diffractometer. The structure was refined by the full-matrix least-squares method to a final R= 0.081 for 3563 observed $[I_0{\geq}2{\sigam}(I_0)]$ reflections. The four independent molecules assume different overall conformations with systematically different orientations of the phenyl groups although the penam moieties have the same closed conformations. There are intramolecular hydrogen bonds between the exocyclic amide nitrogen and phenoxy oxygen atoms. The penam moiety is conformationally very restricted although the carboxyl and exocyclic amide groups apparently have certain rotational degrees of freedom but the phenyl group is flexible about the ether bond despite the presence of the intramolecular N-H${\cdots}$O hydrogen bond. There are complicated pseudo symmetric relationships in the crystal lattice. The penam moieties are related by pseudo 20.5 screw axes and the phenyl groups by pseudo centers of symmetry. The potassium ions, related by both pseudo symmetries, form an infinite zigzag planar chain parallel to the b axis. Each potassium ion is coordinated to seven oxygen atoms in a severely distorted pentagonal bipyramid configuration, forming the infinite hydrophilic channels which in turn form the molecular stacks. Between these stacks, there are only lipophilic interactions involving the phenyl groups.

Computational optimized finite element modelling of mechanical interaction of concrete with fiber reinforced polymer

  • Arani, Khosro Shahpoori;Zandi, Yousef;Pham, Binh Thai;Mu'azu, M.A.;Katebi, Javad;Mohammadhassani, Mohammad;Khalafi, Seyedamirhesam;Mohamad, Edy Tonnizam;Wakil, Karzan;Khorami, Majid
    • Computers and Concrete
    • /
    • v.23 no.1
    • /
    • pp.61-68
    • /
    • 2019
  • This paper presents a computational rational model to predict the ultimate and optimized load capacity of reinforced concrete (RC) beams strengthened by a combination of longitudinal and transverse fiber reinforced polymer (FRP) composite plates/sheets (flexure and shear strengthening system). Several experimental and analytical studies on the confinement effect and failure mechanisms of fiber reinforced polymer (FRP) wrapped columns have been conducted over recent years. Although typical axial members are large-scale square/rectangular reinforced concrete (RC) columns in practice, the majority of such studies have concentrated on the behavior of small-scale circular concrete specimens. A high performance concrete, known as polymer concrete, made up of natural aggregates and an orthophthalic polyester binder, reinforced with non-metallic bars (glass reinforced polymer) has been studied. The material is described at micro and macro level, presenting the key physical and mechanical properties using different experimental techniques. Furthermore, a full description of non-metallic bars is presented to evaluate its structural expectancies, embedded in the polymer concrete matrix. In this paper, the mechanism of mechanical interaction of smooth and lugged FRP rods with concrete is presented. A general modeling and application of various elements are demonstrated. The contact parameters are defined and the procedures of calculation and evaluation of contact parameters are introduced. The method of calibration of the calculated parameters is presented. Finally, the numerical results are obtained for different bond parameters which show a good agreement with experimental results reported in literature.

Behavior of Bond-type Shallow Anchors in Rock Masses ( I ) - Metamorphic Rock (gneiss) at Taean Test Site - (암반에 근입된 부착형 앵커의 거동특성 (I) - 태안지역 편마암 -)

  • Kim, Dae-Hong;Lee, Dae-Soo;Chun, Byung-Sik;Kim, Byung-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.12
    • /
    • pp.45-55
    • /
    • 2006
  • This paper presents the results of full-scale uplift load tests performed on 30 passive anchors grouted to various lengths at Taean site in Korea. Various rock types were tested, ranging from highly weathered to sound gneiss. Rock anchors were installed over a wide range of rock types and qualities with a fixed anchored depth of $1{\sim}4m$. The majority of installations used SD4O-D51 no high grade steel rebar to induce rock failure prior to rod failure. In many tests, rock failure was reached and the ultimate loads were recorded along with observations of the shape and extent of the failure surface. The test results, the failure mechanisms as well as uplift capacities of rock anchors depend mostly on rock type and quality, embedded fixed length, and the strength of rebar. Based on test results, the main parameters governing the uplift capacity of the rock anchor system were determined.

Seismic Retrofit of GFRP Wrapping on the Lap-spliced Bridge Piers (GFRP 래핑에 의한 겹침이음된 교각의 내진보강)

  • Youm, Kwang Soo;Kwon, Tae Gyu;Lee, Young Ho;Hwang, Yoon Kook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2A
    • /
    • pp.311-318
    • /
    • 2006
  • This paper presents experimental studies on investigating the seismic retrofit performance of reinforced concrete circular columns with poor lap-splice details using GFRP wrapping. Five full-scale model columns have been tested. The prototype structure is an existing circular reinforced concrete bridge piers designed following the pre-seismic codes and constructed in South Korea in 1979. The as-built column will be expected to suffer brittle failure due to the bond failure of lap-spliced longitudinal reinforcement. The retrofitted columns using GFRP wrapping showed significant improvement of seismic performance. However, the predicted flexural failure mode was not achieved and the longitudinal bars were not yielded. Failure modes of the retrofitted columns are considered to be the gradually delayed bond slip in lap-spliced longitudinal reinforcement. Suggested retrofit design methods using GFRP were validated experimentally.

Evaluation of Characteristics of Ground Anchor Using Large Scale Laboratory Test (실규모 실험을 이용한 그라운드 앵커의 거동 특성 평가)

  • Sangrae Lee;Seunghwan Seol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.11
    • /
    • pp.19-24
    • /
    • 2023
  • Ground anchor has been widely used specially for maintaining stability on reinforced cut slope in expressway. While the durability of the ground anchors should be ensured over the service life. However, the long-term loss of tensile force has occurred in most of field-installed anchors. Main causes are not clearly identified and very few studies have been made for analyzing long-term behavior of ground anchor in slopes. In this study, full-scale model tests and long-term measurements were made to obtain the load-displacement data and identified the causes of the long-term behaviors of ground anchor. As a result, the bond strength decreases exponentially with increasing water-binder ratio. Especially, groundwater is the most influencing factor to the bond strength. In the long-term behavior, the load decreases sharply until the initial settlement stabilized, and thereafter the tension force decreases constantly.

A comparative study on the fracture behavior of zironia, glass infiltrated alumina and PFM full crown system (지르코니아, 유리침투알루미나 및 PFM 전부관 시스템의 파절 경향에 관한 비교연구)

  • Lee, Sang-Hyeok;Ahn, Jin-Soo;Kim, Myung-Ho;Lim, Bum-Soon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.235-242
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the fracture behavior of Zironia, glass infiltrated Alumina and PFM full crown system. Materials and methods: Fifteen crowns for each of 3 experimental groups (Zironia, glass infiltrated Alumina and PFM full crown) were made by the conventional method. The crowns mounted on the testing jig were inclined in 30 degrees to the long axis of the tooth and the universal testing machine was used to measure the fracture strength. Results: 1. The mean fracture strengths were $588.3{\pm}49.6MPa$ for zirconia system, $569.1{\pm}61.8MPa$ for PFM system and $551.0{\pm}76.5MPa$ for glass-infiltrated alumina system (P>.05). 2. The mean shear bond strengths were $25.5{\pm}5.6MPa$ for zirconia system, $38.9{\pm}5.0MPa$ for Ni-Cr alloy system and $39.4{\pm}5.1MPa$ for glass-infiltrated alumina system. 3. The chemical bonding was observed at interfaces between PFM or glass-infiltrated alumina and veneering porcelain, however, no chemical bonding was observed at interface between zirconia and veneering porcelain. Conclusion: With the study, the fracture strengths of PFM crown system had a higher fracture strength than conventional zirconia system crown and glass-infiltrated alumina crowns. and than the shear bond strengths glass-infiltrated alumina system had a higher shear bond strength than conventional PFM system and zirconia system.

A Study on the determination of Residual Antibiotics and Synthetic Antibacterial Agents in Meas (II) - Simultaneous Gas Charomatography/Mass Spectrometry Analysis of Penicillin G, Chloramphenicol and Thiamphenicol - (식육중의 잔류 항생.항균제의 검정에 관한 연구 (II) - Penicillin G , Chloramphenicol, Thiamphenicol, Gas chromatography/Mass spectrometry 동시 분석 -)

  • 류재천;양종순;서지원;김명수;박종세
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 1993
  • In an attempt to quantitate and qualitate residual antibiotics and antibacterial agents in meat simultaneously, we studied a gas chromatography-mass spectrometry(GC/M8) analysis. For a simultaneous analysis of penicillin G, chloramphenicol and thiamphenicol in meat, a simple and rapid clean-up procedure including extraction with 0.01 M EDTA-2Na Mcilvaine buffer (pH 4.0), defatting with n-hexane, and elution with 0.01M-methanolic oxalic acid from Bond Elute $C_{18}$ cartridge, and quantitation by selected ion monitoring (SIM) mode after derivatization was performed. The recoveries (%) of penicillin G, chloramphenicol and thiamphenicol (CV, %) at 1 ppm fortification level were 63.5 (7.6), 76.3 (8.1) and 84.7 (2.0), and the detection limits of those were 0.6, 0.085 and $0.084\;\mu\textrm{g}$ beef, respectively. This method using 81M mode allows excellent detection and quantitation of residual antibiotics and antibacterial agents in meat. Moreover, confirmation by a full scan electron impact mass spectrum is possible if residual level in the sample in above 1 ppm.

  • PDF

The Crystal and Molecular Structure of Acetone 4-Benzylthiosemicarbazone (Acetone 4-Benzylthiosemicarbazone의 결정 및 분자구조)

  • Park Young Ja;Ahn Choong Tai
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.73-79
    • /
    • 1985
  • The crystal and molecular structure of acetone 4-benzylthiosemicarbazone, $C_{11}H_{15}N_3S$, has been determined by the single crystal X-ray diffraction methods. The crystals are monoclinic, space group $P2_1/c$ with unit cell dimensions, a = 10.249(7), b = 11.403(9), c = 10.149(7)TEX>${\AA}$, ${\beta}$ = 90.9$(1)^0$ and z = 4. The intensities were collected on an automatic four-circle diffractometer with graphite-monochromated Mo-$K_{\alpha}$ radiation. The structure was solved by direct methods and refined by full matrix least-squares methods. The final R was 0.045 for 1554 observed reflections. S-C(8)-N(2)-N(3)-C(9)-C(10) atoms make a zigzag planar chain. There are no unusual bond lengths and angles. There are two independent hydrogen bonds in the crystal structure. One is N-H${\cdots}$S intermolecular hydrogen bond with the length of 3.555${\AA}$ and makes dimer-like units. The other is N-H${\cdots}$N intramolecular hydrogen bond with the length of 2.568${\AA}$. The structure was compared with those of other thiosemicarbazone derivatives.

  • PDF

Comuarative Evaluation on Strength of Several Grout-filled Splice Sleeve (각종 그라우트 충전식 철근이음의 내력에 대한 비교평가)

  • Kim Hyong-Kee
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.635-643
    • /
    • 2004
  • In this study, the tensile strength of 321 full-sized grout-filled splice steeve specimens were compared and analyzed in order to afford the data for a reasonable and economical design of this system. The experimental variables analyzed in this study were embedment length of reinforcing bars, compressive strength of grout, sleeve geometry, loading pattern and final failure mode of specimen. Following main conclusions are obtained : 1) The strength of grout-filled splice sleeve tends to be improved with increasing compressive strength of grout and embedment length of reinforcing bars. Specially this tendency appears apparent in specimens of bond failure rather than rebar failure. 2) The results of this study show that the sleeve geometry have influence on the bond strength of grout-filled splice sleeve. 3) The grout-filled splice sleeve of bond failure don't show the difference of tensile strength according to size of rebar. 4) It is verified that the tensile strength required in ACI and domestic code is retained either when the compressive strength of grout over 70 MPa is used with embedment length of reinforcing bars over 4.5d or when the compressive strength of grout over 80 MPa is used with embedment length of rebars over 3.9d. 5) It is verified that the tensile strength required in AIJ code is retained in case when the embedment length of reinforcing bars is 0.8 times the rebar diameter longer than in ACI code.