• Title/Summary/Keyword: fuel distribution

Search Result 1,400, Processing Time 0.035 seconds

Evaluation of Neutron Flux Distributions of SMART-P IST Region for the Design of Ex-Core Detector (SMART 연구로 노외계측기 설계를 위한 IST 영역의 중성자속 분포 평가)

  • Koo, Bon-Seung;Kim, Kyo-Youn;Lee, Chung-Chan;Zee, Sung-Quun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2005
  • The evaluation of neutron flux distribution was performed for the ex-core detector design of SMART-P. DORT and MCNP code were used for the calculation of energy-dependent neutron flux distribution at 100% full power condition. Two code results show that maximum thermal flux appears at the $1^{st}$ water region in IST region and agree within 10% difference. In addition, another evaluation was performed code with assumptions that cote was composed of fission source and control rod without fuel assemblies. These assumptions make neutron count rate to be minimized. As a results, maximum thermal flux showed $6.99{\times}10^{-2}(n/cm^2-sec)$, when the strength of initial fission source was assumed as $1.0{\times}10^8(n/sec)$. The main reason of these results is due to the thermalization of fast neutrons in the water region and thermal flux is proportional to 80% of total neutron flux. Therefore, optimization of filler material of detector guide tube, position of installation and axial length of detector segments is necessary for the design of ex-core detector to enhance the neutron count rate and above results could be used in ex-core detector design as a fluence requirement.

Simulation of Plume Length Induced by Orimulsion Combustion (오리멀젼 연소시 발생하는 백연의 연기거리 전산모사)

  • Kwak, Byoung-Kyu;Kim, Jong-Ho;Joo, Ji-Bong;Lee, Jeong-Jin;Kim, Jin-Soo;Kim, Young-Hun;Yi, Jong-Heop
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.136-143
    • /
    • 2008
  • The objective of this study is to investigate the visibility of plume at the Y power plant stack, which fires the orimulsion as a fuel. The plume contains numerous primary particles under $1\;{\mu}m$ size and inorganic ions possibly inferred by the chemicals of secondary aerosol formation. We evaluated the visibility of the plume using the modified PLUVUE-II model. The monitoring data on the particle size distribution (PSD) and secondary aerosols of sulfate were applied to estimate and evaluate the main factors of plume opacity. The chemical reactions were applied to the model for the secondary aerosol formation of $(NH_4)_2SO_4(s)$. The maximum plume length was estimated by an optic method using threshold contrast. The results showed that the plume length was strongly dependent upon the PSD and $(NH_4)_2SO_4(s)$ concentration of the plume emitted from the stack.

  • PDF

An Analysis of Economic Evaluation Related to Lane Departure Warning System (주행로이탈예방지원기술 관련 경제성평가 분석)

  • Ryu, Byung-Yong;Choi, Ji-Eun;Bae, Sang-Hoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.5
    • /
    • pp.85-97
    • /
    • 2009
  • Continuous increase of traffic demand has caused confirmed congestion, fuel consumption, emission, safety, etc. as serious social problems at the present time. The Smart Highway Project has been conducted by the supervision of Ministry of Land, Transport and Maritime Affaire to solve such problems since 2007. The Smart Highway Project includes LDWS (Lane Departure Warning System), a system to prevent broadside collisions and accidents, as a sub-technology of road-vehicle associating technologies. This system warns drivers when their vehicle deviates from the lane where they are traveling at high-speed on the highway. In this paper, the LDWS was evaluated using CBA to analyze the socio-economic consequences. Estimated benefits include reduction of accidents and convenience of drivers. In addition, the economics according to the distribution rate is various when it comes to Lane Departure Warning Technology, the economics of both cases - positive scenario and negative scenario, which was analyzed. As a result, the Benefit-Cost ratio(B/C) of negative scenario showed 0.97 in 2020 and 1.36 in 2030 while B/C ratio of the positive scenario showed 1.04 in 2020 and 1.59 in 2030, which indicated that the higher distribution rate is, the higher the economics generates. Therefore, it is judged that the introduction of Lane Departure Warning Technology will result in high economics.

  • PDF

Estimation of Benzene Emissions from Mobile Sources in Korea (국내 이동오염원에서 발생되는 벤젠 배출량 산정)

  • Lee, Ju-Hyoung;Cha, Jun-Seok;Hong, Ji-Hyung;Jung, Dong-Il;Kim, Ji-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.72-82
    • /
    • 2008
  • Benzene is a very harmful and toxic compound known as human carcinogen by all routes of exposure. Owing to the risky feature of benzene, several countries such as Japan, UK and EU have established the ambient air quality standard and protect from that risk of it. Korea also has designated it as one of the criteria air pollutants and established the concentration limit ($5\;{\mu}g/m^3$) in the air and is going to apply the standard from 2010. Benzene is emitted from various sources such as combustion plants, production processes, waste treatment facilities and also automobiles. Mobile source is known as one of the major emission sources of benzene. In this study, we estimated the domestic emissions of benzene from mobile source and compared the results with those of advanced countries. Mobile source was divided into 2 categories, Le., on-road source and non-road source. The total emissions of benzene from mobile source were estimated as 3,106 tons/yr and 1,612 tons/yr was emitted from on-road source and 1,494 tons/yr was from non-road source. Emission ratio of benzene from on-road source showed that 80.0% was from passenger cars, 10.1% was from taxis, 7.2% was from light-duty vehicles, 2.5% was from heavy-duty vehicles and 0.2% was from buses. In the case of non-road source, the distribution showed that 66.3% was from construction machineries, 14.5% was from locomotives, 11.7% was from ships, 7.1% was from agriculture equipments and 0.5% was from aircrafts. The cold-start emissions were estimated as 942 tons/yr and this value was almost 1.5 times greater than that for hot engine emissions (608 tons/yr). In addition, the fuel-based distribution was 65.9%, 31.1% and 2.8% from gasoline, LPG and diesel vehicles, respectively. The emission ratio from mobile source occupied 65% and 30% of total benzene emissions in USA and UK, respectively. In case of Korea, the emission ratio of benzene from mobile source occupied 29% (15% from on-road source, 14% from non-road source) which showed similar value with UK.

Experimental Study on the Heating Performances of the Air Heater with Diesel for Passenger Cabin Heating of an Electric Vehicle (전기자동차용 승차공간 난방용 디젤 공기 히터의 실차 성능에 관한 연구)

  • Bang, You-Ma;Seo, Jae-Hyeong;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7250-7255
    • /
    • 2015
  • The objective of this study is to experimentally investigate the heating performances of the portable air combustion heater using diesel fuel for auxiliary cabin heating of the battery electric vehicle. In order to evaluate the heating performances of the air combustion heater, the heating capacity was calculated by the temperature at inlet and outlet parts of the considered heater and the inner temperature distribution characteristics of the vehicle were measured during 1600 seconds with an interval of 1 second. The theoretical efficiency of the tested heater was calculated by temperature data of the air of supplying and exhausting to the cabin. As the air passed the heat-sink, the air temperature at the end of heat-sink reached to $101.3^{\circ}C$ and the difference of temperature on heat-sink was 67.8%. The average heating capacity of the air combustion heater showed 2.0 kW. After 1800 seconds, the inner temperature of the vehicle cabin was continuously increased. The temperatures of the top side and the bottom side of the car cabin under consideration were increased upto $42.5^{\circ}C$ and $24.3^{\circ}C$, respectively, and the theoretical efficiency of the tested heater was on average 63.7%.

Temporal and Spatial Distribution of Ambient Sulfur Dioxide Concentration in Forest Areas, Korea (우리나라 산림지역에서의 이산화황 농도의 시.공간적 분포)

  • Seung-Woo, Lee;Lee, Choong-Hwa;Ji, Dong-Hun;Youn, Hee-Jung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.1035-1039
    • /
    • 2010
  • For 65 national forest areas in 1993 to 2008, the ambient sulfur dioxide ($SO_2$) concentrations were measured monthly using passive samplers and compared to the those of urban areas in order to investigate the characteristics of temporal and spatial distribution. In the forest areas, annual average concentration of sulfur dioxide gradually decreased from the beginning year of monitoring to 1997 and then had no significant change, such as the annual trend in urban areas monitored by Ministry of Environment. For the monitoring term, average concentration of sulfur dioxide in the forest areas was 5.6ppb, which was lower than the 10.1ppb in the urban areas and the EC ecological standard level (7.6 ppb). Seasonally, both in forest areas and urban areas the monthly average concentrations were much higher in winter and spring due to much more heating fuel consumption, and lowest in summer. Regional comparison to other regions of Gyeongbuk and Gyeonggi province showed that the concentration of sulfur dioxide was the highest during year. A significant positive correlation between sulfur oxides' emissions and sulfur dioxide concentration by province was observed, reflecting that the size and proximity of sources of atmospheric sulfur oxides could be important factors in determination.

Anthracite Oxygen Combustion Simulation in 0.1MWth Circulating Fluidized Bed (0.1 MWth 급 순환유동층에서의 무연탄 연소 전산유체역학 모사)

  • Go, Eun Sol;Kook, Jin Woo;Seo, Kwang Won;Seo, Su Been;Kim, Hyung Woo;Kang, Seo Yeong;Lee, See Hoon
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.417-428
    • /
    • 2021
  • The combustion characteristics of anthracite, which follow a complex process with low reactivity, must be considered through the dynamic behavior of circulating fluidized bed (CFB) boilers. In this study, computational fluid dynamics (CFD) simulation was performed to analyze the combustion characteristics of anthracite in a pilot scale 0.1 MWth Oxy-fuel circulating fluidized bed (Oxy-CFB) boiler. The 0.1MWth Oxy-CFB boiler is composed of combustor (0.15 m l.D., 10 m High), cyclone, return leg, and so on. To perform CFD analysis, a 3D simulation model reactor was designed and used. The anthracite used in the experiment has an average particle size of 1,070 ㎛ and a density of 2,326 kg/m3. The flow pattern of gas-solids inside the reactor according to the change of combustion environment from air combustion to oxygen combustion was investigated. At this time, it was found that the temperature distribution in air combustion and oxygen combustion showed a similar pattern, but the pressure distribution was lower in oxygen combustion. addition, since it has a higher CO2 concentration in oxygen combustion than in air combustion, it can be expected that carbon dioxide capture will take place actively. As a result, it was confirmed that this study can contribute to the optimized design and operation of a circulating fluidized bed reactor using anthracite.

Stress Distribution Analysis for High Pressure CNG Pressure Vessel Using FEM (유한요소법을 이용한 고압 CNG압력용기 응력분포 해석)

  • Choi, Sang In;Kim, Young Chul;Kim, Myung Soo;Baek, Tae Hyun
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.2
    • /
    • pp.427-435
    • /
    • 2017
  • Most of the domestic city buses are equipped with the pressure vessels subjected to internal pressure applied by compressed natural gas. Pressure vessels subjected to internal pressure are used in various forms and purposes. Fuel is explosive and has flammable high pressure. The damage of the pressure vessel causes many property damage and loss of life. Safe design for pressure vessel is always necessary. Due to these reasons, many studies using finite element analysis have been conducted. In this paper, the stresses of cylindrical vessel and spherical dome were analyzed using ANSYS, a finite element analysis software. In order to verify the validity of the analysis, a model with a perfectly spherical shape of the dome was designed and observed. Based on the ASME standard in used, stress distribution was also analyzed for models designed with compressed natural gas(CNG). The FEM analysis software agreed with the theory when the dome shape was perfectly spherical. The model designed based on the ASME specification theory, stress concentration occurred in the knuckle part.

Manufacture of the vol-oxidizer with a capacity of 20 kg HM/batch in $UO_2$ pellets using a design model (설계 모델을 이용한 $UO_2$ 펠릿 20 kg HM/batch용 분말화 장치 제작)

  • Kim Young-Hwan;Yoon Ji-Sup;Jung Jae-Hoo;Hong Dong-Hee;Uhm Jae-Beop
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.255-263
    • /
    • 2006
  • Vol-oxidizer is a device to convert $UO_2$ pellets into $U_3O_8$ powder and to feed a homogeneous powder into a Metal Conversion Reactor in the ACP(Advanced Spent Fuel Conditioning Process). In this paper, we propose a design model of the vol-oxidizer, develop the new vol-oxidizer with a capacity of 20 kg HM/batch in $UO_2$ pellets, and conduct a verification for the device. Design considerations include the internal structure, the capacity, the heating position of the device, and the size. The dimensions of the new vol-oxidizer are decided by the design model. We determine a permeability test of the $U_3O_8$ measuring the temperature distribution, and the volume of $UO_2$ and $U_3O_8$. We manufactured the new vol-oxidizer for a 20 kg HM/batch in $UO_2$ pellets, and then analyzed the characteristics of the $U_3O_8$ powder for the verification. The experimental results show that the permeability of the $U_3O_8$ throughout mesh enhance more than old vol-oxidizer, the oxidation time takes only 8 hours when compared with the 13 hours of the old device, and the average distribution of particle size is $40{\mu}m$. The capacities of new vol-oxidizer for a 20 kg HM/batch in $UO_2$ pellets were agree well with the predictions of design model.

  • PDF

A Study on Construction and Application of Nuclear Grade ESF ACS Simulator (원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kei-Woo;Park, Jeong-Seo;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.319-327
    • /
    • 2010
  • A nuclear plant ESF ACS simulator was designed, built, and verified to perform experiment related to ESF ACS of nuclear power plants. The dimension of 3D CAD model was based on drawings of the main control room(MCR) of Yonggwang units 5 and 6. The CFD analysis was performed based on the measurement of the actual flow rate of ESF ACS. The air flowing in ACS was assumed to have $30^{\circ}C$ and uniform flow. The flow rate across the HEPA filter was estimated to be 1.83 m/s based on the MCR ACS flow rate of 12,986 CFM and HEPA filter area of 9 filters having effective area of $610{\times}610mm^2$ each. When MCR ACS was modeled, air flow blocking filter frames were considered for better simulation of the real ACS. In CFD analysis, the air flow rate in the lower part of the active carbon adsorber was simulated separately at higher than 7 m/s to reflect the measured value of 8 m/s. Through the CFD analyses of the ACSes of fuel building emergency ventilation system, emergency core cooling system equipment room ventilation cleanup system, it was confirmed that all three EFS ACSes can be simulated by controlling the flow rate of the simulator. After the CFD analysis, the simulator was built in nuclear grade and its reliability was verified through air flow distribution tests before it was used in main tests. The verification result showed that distribution of the internal flow was uniform except near the filter frames when medium filter was installed. The simulator was used in the tests to confirm the revised contents in Reg. Guide 1.52 (Rev. 3).