• 제목/요약/키워드: fuel cell test

검색결과 438건 처리시간 0.027초

연료전지 차량 주행시 스택의 진동 특성 연구 (A Study on the Vibratory Characteristics of the Stack in Fuel Cell Vehicle at Driving Condition)

  • 주형준;김기훈;박재용
    • 한국자동차공학회논문집
    • /
    • 제18권5호
    • /
    • pp.50-55
    • /
    • 2010
  • In recent years, the development of fuel cell vehicles has further accelerated because of environmental problem and petroleum resources shortage. The fuel cell vehicles have the stack which converts fuel to electricity. The stack is usually mounted by bush to isolate the vibration of chassis and body. This paper analyzed the vibratory characteristics of stack and chassis, body system. The wheel forces of fuel cell vehicle are measured to estimate the road load data. And the paths of vibration from wheel to stack are analyzed by CAE. According to the test and CAE results, the improvement of stack vibration are evaluated.

Synthetic Jet Air Blower를 이용한 Free Breathing 연료전지의 성능 평가 (Performance Evaluation of Free breathing Fuel Cell by using Synthetic Jet Air Blower)

  • 최종필;구보성;장재혁;서영호;김병희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2834-2838
    • /
    • 2008
  • An free breathing proton exchange membrane fuel cell (PEMFC) was developed. This paper presents a study of the several effect on the performance of a fuel cell such as air flow rate, opening ratio, and cathode structures. Especially, an air flow rate is critical condition to improve the fuel cell performance. In this paper, we developed a synthetic jet micro air blower to supply high stoichiometric air. The synthetic jet actuation is usually generated by a traditional PZT-driven actuator, which consists of a small cylindrical cavity, orifices and PZT diaphragms. In comparison with free convection fuel cells, the forced-convection fuel cell which equipped synthetic jet micro air blower brings higher performance and stability for long term test. Also, power consumption of the synthetic jet micro air blower is under 0.3W. The results show that the maximum power density was $188mW/cm^2$ at $400mA/cm^2$. The maximum power density was higher 40% than power density of free convection fuel cell.

  • PDF

연료전지 발전을 위한 바이오가스정제 (Biogas Purifying for Fuel cell Power Plant)

  • 이종규;전재호
    • 상하수도학회지
    • /
    • 제21권4호
    • /
    • pp.439-444
    • /
    • 2007
  • Using the anaerobic digester gas as a fuel, fuel cells have the potential to provide significant environmental and economic benefits. A molten carbonate fuel cell power plant was installed in the municipal sewage works of Tancheon in Seoul. The fuel cell unit operates on anaerobic digester gas and provides power and heat for the sewage works. This is the first project of its kind in Korea. This article outlines the experiences of gas purification process with planning, installation and operation. The engineering and installation phase is described regarding to the special features of digester gas, for example impurities in gas composition. Such impurities would be harmful to fuel cells. Operational results from the field test with a gas purification process plant are presented in this paper.

입자법을 이용한 회전익항공기 연료셀 피탄 수치모사 (Numerical Simulation of Bullet Impact for Fuel Cell of Rotorcraft using Smoothed Particle Hydrodynamics)

  • 김현기;김성찬
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.2553-2558
    • /
    • 2014
  • 회전익 항공기 중 군에서 운용하는 기동헬기는 전장상황에서 운용되기 때문에 연료셀 피탄 시 발생 가능한 상황을 예측하여 설계에 반영해야 한다. 연료셀 설계 고려사항은 피탄 상황의 연료셀 내부 압력, 충격파에 의한 연료셀 자체 및 금속 피팅부 응력, 탄의 운동에너지 등이 포함될 수 있다. 중요 설계데이타 확보를 위해서는 실물 연료셀을 이용한 입증시험을 수행하는 것이 가장 좋은 방법이다. 그러나, 극한조건하의 입증시험은 상당한 비용과 시간이 요구되며, 실패 위험성도 높다. 따라서, 실물을 이용한 시험을 수행하기 전 시행착오의 가능성을 줄이기 위해서는 다양한 수치해석을 통해 연료셀 내부압력과 응력 등의 설계 데이타 예측이 반드시 필요하다. 본 연구에서는 입자법을 사용하여 연료셀의 중요 입증시험 중 하나인 피탄시험에 대한 수치해석을 수행하였다. 수치해석은 전용 충돌해석 프로그램인 LS-DYNA를 사용하였고, 피탄의 영향으로 연료셀 내부 압력은 350~360MPa, 수압램에 의한 굽힘하중으로 260~350MPa의 등가응력이 금속피팅부에 발생하는 것으로 파악되었다.

An Experimental Analysis of the Ripple Current Applied Variable Frequency Characteristic in a Polymer Electrolyte Membrane Fuel Cell

  • Kim, Jong-Hoon;Jang, Min-Ho;Choe, Jun-Seok;Kim, Do-Young;Tak, Yong-Sug;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • 제11권1호
    • /
    • pp.82-89
    • /
    • 2011
  • Differences in the frequency characteristic applied to a ripple current may shorten fuel cell life span and worsen the fuel efficiency. Therefore, this paper presents an experimental analysis of the ripple current applied variable frequency characteristic in a polymer electrolyte membrane fuel cell (PEMFC). This paper provides the first attempt to examine the impact of ripple current through immediate measurements on a single cell test. After cycling for hours at three frequencies, each polarization and impedance curve is obtained and compared with those of a fuel cell. Through experimental results, it can be absolutely concluded that low frequency ripple current leads to long-term degradation of a fuel cell. Three different PEMFC failures such as membrane dehydration, flooding and carbon monoxide (CO) poisoning that lead to an increase in the impedance magnitude at low frequencies are simply introduced.

Modeling and Energy Management Strategy in Energetic Macroscopic Representation for a Fuel Cell Hybrid Electric Vehicle

  • Dinh, To Xuan;Thuy, Le Khac;Tien, Nguyen Thanh;Dang, Tri Dung;Ho, Cong Minh;Truong, Hoai Vu Anh;Dao, Hoang Vu;Do, Tri Cuong;Ahn, Kyoung Kwan
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권2호
    • /
    • pp.80-90
    • /
    • 2019
  • Fuel cell hybrid electric vehicle is an attractive solution to reduce pollutants, such as noise and carbon dioxide emission. This study presents an approach for energy management and control algorithm based on energetic macroscopic representation for a fuel cell hybrid electric vehicle that is powered by proton exchange membrane fuel cell, battery and supercapacitor. First, the detailed model of the fuel cell hybrid electric vehicle, including fuel cell, battery, supercapacitor, DC-DC converters and powertrain system, are built on the energetic macroscopic representation. Next, the power management strategy was applied to manage the energy among the three power sources. Moreover, the control scheme that was based on back-stepping sliding mode control and inversed-model control techniques were deduced. Simulation tests that used a worldwide harmonized light vehicle test procedure standard driving cycle showed the effectiveness of the proposed control method.

마이크로 연료전지용 강제 호흡형 공기 공급 모듈에 관한 연구 (A Study on Forced Aspirating Air Supplying Module for Micro Fuel Cell)

  • 황준영;윤효진;이상호;강희석;강경태
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.49-52
    • /
    • 2008
  • The present study conducts a series of experiments to develop a novel air supplying module for a micro fuel cell using piezoelectric linear actuator. An intermittently and operating air breathing module with reciprocating motion of the linear actuator has been suggested in the present study. A test bench for a micro fuel cell system has been constructed to estimate performance of the active fuel cell system using the air supplying module. With the stroke and operating duty as main control parameters, the optimal operating method of the air supplying module has been discussed.

  • PDF

연료전지차용 수소배출 배관 및 배관이음매 안전성 평가를 위한 기초 연구 (The Basic Study on the Leak Test Method of the Hydrogen Exhaust Pipe for a Fuel Cell Vehicle)

  • 서호철;박경석;서경두;용기중
    • 한국정밀공학회지
    • /
    • 제28권2호
    • /
    • pp.185-192
    • /
    • 2011
  • This study deals with a basic proposal to prove the safety for the exhausted fittings of the hydrogen fuel cell vehicle. First, this study was approached to numerical analysis solving to close the exact boundary condition (Axial, Bending, Lateral) and the second, this study produced the Lateral movement equipment for the vibration. For the numerical analysis, This study was considered with the exact solution of Lateral movement and the resonance effect for durability sample according to fitting positions. The second, This study was made for special equipment for displacement/gas leak and the frequency because the domestic samples were comparing with foreign fitting and foreign fitting for the hydrogen fuel cell vehicle. The result of this study was satisfied with domestic fittings for the basic reference but it need more test because of other situation for hydrogen fuel cell vehicle.

고분자 연료전지시스템의 기동 및 정지특성에 관한 연구 (A Study on the Start-up and Shut-down Characteristics for PEMFC System)

  • 이정운;서원석;김영규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.29-32
    • /
    • 2008
  • Testing was conducted to determine the performance of a residential fuel cell system when subjected to DSS and WSS operation, especially for start-up and shut-down characteristics. In terms of start-up time, it took about 70min to start output power generation and stably to reach 1kW at cold start. Measurement of the characteristics of heat and power generation were carried out at start-up and shut-down time. Fuel gas is used for heating both reformer and stack from start-up to the beginning of power generation. In terms of start-up and shut-down characteristics, it was important to control the reformer temperature precisely. The average output water temperature during the rated output operation(960W) was $63.2^{\circ}C$ constantly. The results of the investigation are being used to develop a new test protocols for residential fuel cell system.

  • PDF

연료전지 차량용 TYPE3 복합재 고압용기 개발 (Development of Hydrogen Type3 composite cylinder for Fuel Cell vehicle)

  • 정재한;조성민;김태욱;박지상;정상수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.165-168
    • /
    • 2007
  • The objective of this study is to demonstrate and commercialized for on-board fuel storage system for the hydrogen fuel cell vehicles. Type3 composite cylinder is consisting of the full wrapped composites on a seamless aluminum liner. Especially, the seamless aluminum liner has been commercialized with development of fabrication through this study. The key technologies, including design, analysis and the optimized filament winding process for 350bar composite cylinder, were established and verified with design qualification test in accordance with international standard. And the facilities for fabrication and design qualification test have been constructed.

  • PDF