• Title/Summary/Keyword: frequency resonance test

Search Result 341, Processing Time 0.028 seconds

Study on Thickness Measurement about Insulation Rubber of Steel Motor Case Using Ultrasonic Resonance (초음파 공진을 이용한 스틸 연소관의 내열 고무 두께 측정 기법 연구)

  • Kim, Dong-Ryun;Kim, Jae-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.562-569
    • /
    • 2012
  • The rubber side could be contaminated using the existing pulse echo method because the ultrasonic wave was incident on the rubber side from the interior of the steel motor case, which could lead to the critical disbond defect. To develop the test method which can be replaced the existing method, the ultrasonic wave was incident on steel face of the steel/rubber adhesive test block. Rubber resonance frequencies measured from the steel/rubber adhesive test block were in good agreement with theoretically predicted rubber resonance frequencies. This paper was described about the ultrasonic resonance method to convert the rubber resonance frequency into the rubber thickness.

  • PDF

Development of the Predicted Model for the HMA Dynamic Modulus by using the Impact Resonance Testing and Universal Testing Machine (충격공진실험과 만능재료시험기에 의한 아스팔트 공시체의 동탄성계수 예측 모델 개발)

  • Kim, Do Wan;Kim, Dong-Ho;Mun, Sungho
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.43-50
    • /
    • 2014
  • PURPOSES : The dynamic modulus can be determined by applying the various theories from the Impact Resonance Testing(IRT) Method. The objective of this paper is to determine the best theory to produce the dynamic modulus that has the lowest error as the dynamic modulus data obtained from these theories(Complex Wave equation Resonance Method related to either the transmissibility loss or not, Dynamic Stiffness Resonance Method) compared to the results for dynamic modulus determined by using the Universal Testing Machine. The ultimate object is to develop the predictive model for the dynamic modulus of a Linear Visco-Elastic specimen by using the Complex Wave equation Resonance Method(CWRM) came up for an existing study(S. O. Oyadiji; 1985) and the Optimization. METHODS : At the destructive test which uses the Universal Testing Machine, the dynamic modulus results along with the frequency can be used for determining the sigmoidal master curve function related to the reduced frequency by applying Time-Temperature Superposition Principle. RESULTS : The constant to be solved from Eq. (11) is a value of 14.13. The reduced dynamic modulus obtained from the IRT considering the loss factor related to the impact transmissibility has RMSE of 367.7MPa, MPE of 3.7%. When the predictive dynamic modulus model was applied to determine the master curve, the predictive model has RMSE of 583.5MPa, MPE of 3.5% compared to the destructive test results for the dynamic modulus. CONCLUSIONS : Because we considered that the results obtained from the destructive test had the most highest source credibility in this study, the dynamic modulus data obtained respectively from DSRM, CWRM were compared to the results obtained from the destructive test by using th IRT. At the result, the reduced dynamic modulus derived from DSRM has the most lowest error.

Resonance Mode Anlaysis in a Single Can-type Combustor through 3D Thermo-acoustic Analysis based on Helmholtz Solver (헬름홀츠 솔버 기반의 3차원 열음향해석을 통한 발전용 단일 캔 연소기에서의 공진 모드 분석)

  • Junwoo Jung;Daesik Kim
    • Journal of ILASS-Korea
    • /
    • v.29 no.1
    • /
    • pp.23-31
    • /
    • 2024
  • This study conducted a 3D thermo-acoustic analysis based on the helmholtz solver to analyze the major resonance modes causing combustion instability in a single-can combustor. The experimental investigations were carried out on a test rig designed by the Korea Institute of Machinery & Materials (KIMM) under various conditions of hydrogen co-firing and fuel staging. Through these experiments, two primary unstable frequencies were identified. To determine the resonance modes of these frequencies, a 3D thermo-acoustic analysis was conducted using temperature information from the test rig. The results confirmed that the unstable frequencies observed in the experiments were all longitudinal modes. Additionally, the mode shapes identified in the analysis facilitated a simplification of the exit geometry for the low-order network model, confirming that this did not significantly affect the fundamental resonance modes.

Evaluation of Blade Resonance of 5MW Power Generation Gas Turbine (발전용 소형가스터빈 블레이드 공진 안정성 평가)

  • Ahn, Sung-Jong;Park, Lu-Ke;Yun, Tae-Jun;Suk, Jin-Ik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.433-438
    • /
    • 2011
  • Doosan has been developing a 5MW class gas turbine engine, DGT-5. Campbell diagram has been used for prediction of possible occurrence of resonances of rotating machinery. The Campbell diagram consists of blade natural frequency and excitation frequency. In this paper, modal characteristics of compressor and turbine blades are investigated and Campbell diagram is obtained. We calculated compressor and turbine blade's natural frequency using ANSYS tool. The result has been verified through test.

  • PDF

Estimation of Mechanical Properties of Concrete in Early Age by Resonance Frequency Test (공명주기식 동탄성계수를 이용한 초기재령 콘크리트의 역학적 성질 예측)

  • Kim, Jin-Keun;Kiim, Hoon;Noh, Jae-Ho
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.5
    • /
    • pp.164-171
    • /
    • 1995
  • Drying shrinkage and hydration heat are important factors on the initiation of the crack in con crete at early age. Therefore, the stress caused by hydration heat and drying shrinkage should be .analyzed to predict whether the crack occurrs or not. And, mechanical properties of early age concrete is also required for the predicting crack formation In this study, non-destructive test method of resonance frequency was used to find the relation between dynamic modulus and mechanical properties of concrete in early age. Test results were compared with existing equations, and a new equation based on test. results in this study and other data was also proposed

Numerical study on the resonance behavior of submerged floating tunnels with elastic joint

  • Park, Joohyun;Kang, Seok-Jun;Hwang, Hyun-Joong;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.207-218
    • /
    • 2022
  • In submerged floating tunnels (SFTs), a next-generation maritime transportation infrastructure, the tunnel module floats in water due to buoyancy. For the effective and economical use of SFTs, connection with the ground is inevitable, but the stability of the shore connection is weak due to stress concentration caused by the displacement difference between the subsea bored tunnel and the SFT. The use of an elastic joint has been proposed as a solution to solve the stability problem, but it changes the dynamic characteristics of the SFT, such as natural frequency and mode shape. In this study, the finite element method (FEM) was used to simulate the elastic joints in shore connections, assuming that the ground is a hard rock without displacement. In addition, a small-scale model test was performed for FEM model validation. A parametric study was conducted on the resonance behavior such as the natural frequency change and velocity, stress, and reaction force distribution change of the SFT system by varying the joint stiffness under loading conditions of various frequencies and directions. The results indicated that the natural frequency of the SFT system increased as the stiffness of the elastic joint increased, and the risk of resonance was the highest in the low-frequency environment. Moreover, stress concentration was observed in both the SFT and the shore connection when resonance occurred in the vertical mode. The results of this study are expected to be utilized in the process of quantitative research such as designing elastic joints to prevent resonance in the future.

A study on the design optimization of baseframe to avoid resonance of diesel generator set (발전기세트 공진 회피를 위한 베이스프레임 최적설계에 관한 연구)

  • Jeong, S.H.;Kwak, Y.S.;Kim, W.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.157-162
    • /
    • 2012
  • A structural modification of baseframe is an effective method to avoid resonance in marine diesel generator (D/G) set which consists of diesel engine, generator and baseframe. However the reinforcement with thick plates or additional parts to increase the natural frequency can be less effective because of increased weight. Especially fine control of target mode based on the experience is difficult because the weight and interference of system have to be considered. In this paper, the design optimization of baseframe was performed to reduce the resonant vibration using a gradient descent method. The design parameters such as thickness, shape and location of baseframe parts are optimized to increase the torsional natural frequency of D/G set. From the actual test, the new designed baseframe reduced the vibration level in resonance by 55% without any increase of weight and interference. interference.

  • PDF

A Study for Evaluation of Hot Mixed Asphalt Mixtures with Tack-Coat Regarding High-Frequency Dynamic Resistance Performance and Bonding Property (택코트 첨가 가열아스팔트 혼합물의 고주파 동적저항 특성 및 접착성능 평가에 대한 연구)

  • Kim, Dowan;Mun, Sungho
    • International Journal of Highway Engineering
    • /
    • v.17 no.3
    • /
    • pp.35-47
    • /
    • 2015
  • PURPOSES : A tack coat has been utilized to increase the bond performance between the surface layer and base course (intermediate course) at various road pavement sites. This is similarly true in other nations. Based on this connection, the objective of the present study is to evaluate the properties of hot mix asphalt (HMA) mixtures with an RSC-4 or BD-Coat and determine the application rate of the tack coat. METHODS : The HMA specimens were manufactured using superpave gyratory compaction. The HMA mixtures were composed of a 5-cm thick surface layer and a 10-cm thick base course. An impact hammer resonance test (IHRT) and a static load shear test were conducted to evaluate the performance of the HMA mixtures with a tack coat. From these tests, the dynamic moduli related to the high-frequency resistance and interlayer shear strength (ISS) of HMA could be obtained. RESULTS : The results of the dynamic moduli of HMA are discussed based on the resonance frequency (RF). To check the accuracy of the IHRT, we conducted a coherence analysis. A direct shear test using the application of a static load test was carried out to evaluate the interlayer shear strength (ISS) of HMA. CONCLUSIONS : The maximum ISS was demonstrated at an RSC-4 application rate of 462 gsm, and the maximum dynamic modulus was demonstrated at an RSC-4 application rate of 306 gsm. By averaging the results of the ISS, the maximum ISS values were obtained when a BD-Coat application rate of 602 gsm was applied.

An Experimental Study on the Modal Test of Steam Turbine Shround Band (터빈 Shroud Band Modal Test에 관한 실험적 연구)

  • 조철환;양경현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.470-476
    • /
    • 2002
  • We tested the natural frequency for the 1st moving blades of a steam turbine in general power plants, carried out the modal test of the blade groups each natural frequency. By this test results, we identified the resonance results largely in damaging the blades. We can predict damage probability for the blade groups and change state of material property by using the result of this study.

  • PDF

Effect of Mixing and Placing in Hot Weather on Hardened Concrete Properties

  • Ham, Suyun;Oh, Taekeun
    • International Journal of Concrete Structures and Materials
    • /
    • v.7 no.2
    • /
    • pp.165-174
    • /
    • 2013
  • Portland cement concrete exposed to high temperatures during mixing, transporting, casting, finishing, and curing can develop undesirable characteristics. Applicable requirements for such the hot weather concrete differ from country to country and government agencies. The current study is an attempt at evaluating the hardened properties of the concrete exposed to hot weather in fresh state. First of all, this study reviews the current state of understanding and practice for hot weather concrete placement in US and then roadway sites with suspected hot weather concrete problems were investigated. Core samples were obtained from the field locations and were analyzed by standard resonance frequency analysis and the boil test. Based on the results, there does not appear to be systematic evidence of frequent cracking problems related to high temperature placement. Thus, the suspicious deteriorations which are referable to hot weather concreting would be due to other factors.