• Title/Summary/Keyword: frequency resonance test

Search Result 341, Processing Time 0.029 seconds

Is Adjacent Segment Disease More Frequent in Proximal Levels in Comparison with Distal Levels? Based on Radiological Data of at Least 2 Years Follow Up with More than 2 Level Thoracolumbar Fusions

  • Kim, Jung-Ho;Ryu, Dal-Sung;Yoon, Seung-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.603-609
    • /
    • 2019
  • Objective : The purpose of this retrospective study was to determine which of the proximal adjacent segment disease (ASD) and distal ASD was more prevalent and what parameters is more related to ASD in proximal levels and distal levels after more than 2 levels fusions. Methods : The medical records were reviewed retrospectively for 856 cases. A total of 66 cases of ASD were enrolled. On preop magnetic resonance imaging, disc degeneration was measured at the upper and lower parts of surgically treated levels and confirmed by the commonly used Pfirrmann grade. Segmental flexibility in sagittal plane was embodied in segment range of motion (ROM) obtained through flexion and extension X-ray before surgery. Coronal angle was recorded as methods Cobb's angle including fusion levels preoperatively. For the comparison of categorical variables between two independent groups, the chi-square test and Fisher exact test were performed. Results : Proximal ASD and distal ASD were 37/856 (4.32%) and 29/856 (3.39%), respectively. The incidence of proximal ASD was relatively high but insignificant differences. In comparison between ASD group and non ASD group, proximal Pfirmman was higher in proximal ASD and distal Pfirmman was higher in distal ASD group (p=0.005, p<0.008, respectively). However, in the ROM, proximal ROM was higher in proximal ASD, but distal ROM was not different between the two groups (p<0.0001, p=0.995, respectively). Coronal angle was not quite different in both groups (p=0.846). Conclusion : In spite of higher frequency in ASD in proximal level in spinal fusion, it is not clear that incidence of ASD in proximal level is not higher than that of distal ASD group in more than 2 level thoracolumbar fusions. Not only Pfirrmann grade but also proximal segmental ROM is risk factor for predicting the occurrence of ASD in patients more than 2 level of thoracolumbar spine fusion operation excluding L5S1.

The Research of the Heavy-Weight Impact Sound Characteristic by Live load Installation on the Source Room (공동주택 음원실 바닥의 하중 설치에 따른 중량충격음 특성에 관한 연구)

  • Kim, Kyoung-Woo;Yang, Kwan-Seop;Sohn, Jang-Yeul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.6
    • /
    • pp.235-242
    • /
    • 2007
  • The test and evaluation of floor impact sound is mainly conducted before move in the residence. Floor impact sound generating is actually the conditions in which a heavy load like a curtain and furniture is installed, the situation before and after move in the residence is different. In this study, we investigate the floor impact sound variations according to the live load installation like furniture in the source room. The vibration acceleration level and floor impact sound level variation were measured before and after live load ($200kg/m^2$) installation in the floor impact sound test building and the field. The difference was not large although the vibration acceleration level and the floor impact sound level were reduced through measurement result of load installation. Resonance frequency was not changed by load installation.

A Study on the Model Test for Estimating Dynamic Vertical Load Added to Shallow Foundation for Machine (진동기 얕은기초에 추가되는 동적 연직하중 산정을 위한 모형실험 방안 연구)

  • Ha, Ik-Soo;Yoo, Mintaek
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.157-165
    • /
    • 2020
  • At present, there are no clearly stated criteria or theories in calculating additional vertical dynamic loads that occur at the machine foundation due to vibration and reflecting them in the design at home and abroad. According to the domestic standard, although it is not a serious vibration condition, the additional dynamic load due to vibration is considered up to 100% of the static load. This is an extremely conservative design. The purpose of this study is to propose a model test method for evaluating the quantitative magnitude of additional dynamic loads that are generated at certain static loads due to vertical mechanical vibrations. As preliminary basic tests for the model tests, the test for evaluating the effects of reflective wave that may occur within a limited size soil box and the test for estimating the natural frequency of the devised model soil-foundation system were carried out. From the analysis of results for basic tests, a method to minimize the influence of the reflected wave was prepared, and the effect of the resonance of the model system was minimized during the model tests. After the basic tests, the main model tests were conducted. Through the proposed main test, the quantitative magnitude of additional dynamic loads caused by machine vibration on a shallow foundation for machine on medium dense sand foundations were evaluated. From the results of the model test, the feasibility of design applied at home and abroad was reviewed.

Surface characteristics and stability of implants treated with alkali and heat (알칼리와 열처리에 의한 임플란트의 표면 특성 및 골유착 안정성에 관한 연구)

  • Song, Yun-Seok;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.490-499
    • /
    • 2008
  • Statement of problem: Bioactive materials must have the ability to spontaneously form a bone like apatite layer on their surface and induce direct biochemical bonding to bone. A simple chemical treatment via alkali and heat has been revealed to induce bioactivity in titanium. Purpose: The purpose of this study was to evaluate the surface characteristics and stability of alkali and heat treated implants. Material and methods: Specimens were divided into three groups; group 1 was the control group with machined surface implants, groups 2 and 3 were treated with alkali solutions and heat treated in the atmosphere and vacuum conditions respectively. The surface characteristics were observed with FESEM, XPS, TF-XRD and AFM. Stability was evaluated with the resonance frequency analysis, periotest and removal torque values. One-way ANOVA and Duncan test were used for statistical analysis. Results: 1. Groups treated with alkali and heat showed similar characteristics. Groups 2 and 3 showed high compositions of Na ions on the surface with sub-micron sized pores compared to group 1. Group 2 showed mixed compositions of anatase and rutile with superior contents of rutile. 2. Resonance frequency analysis : The ISQ of group 2 showed significantly higher values than that of groups 1 and 3 at 12 weeks. The ISQ of groups 1 and 2 showed significant increase after 4 weeks, and the ISQ of group 3 increased significantly after 2 and 4 weeks respectively (P < .05). 3. Periotest: The PTV of groups 1 and 2 showed significant decrease after 4 weeks, and the PTV of group 3 showed significant decrease after 2 and 4 weeks respectively (P < .05). 4. Removal torque analysis: The removal torque value of group 2 was significantly higher than those of groups 1 and 3 at 2, 4 and 8 weeks. The removal torque values of groups 1 and 3 showed increase at 4 and 12 weeks, but the removal torque value of group 2 showed increase after 4 weeks (P < .05). Conclusion: An oxide layer with appropriate crystal structure and amorphous sodium titanate layer can be obtained on titanium implants through alkali and heat treatment in the atmosphere, and even alkali and heat treatment in vacuum conditions, provided a bioactive surface containing sodium. These surface layers can be considered to be effective for enhancement of osseointegration and reduction of healing period for implant treatment.

Comparison of Measured Natural Frequencies of a Railway Bridge Specimen Between Different Excitation Methods (철도교량 시험체의 가진방법에 따른 고유진동수 측정치 변동에 대한 비교 분석)

  • Kim, Sung-Il;Lee, Jungwhee;Lee, Pil-Goo;Kim, Choong-Eon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6A
    • /
    • pp.535-542
    • /
    • 2010
  • Precise estimation of a structure's dynamic characteristics is indispensable for ensuring stable dynamic responses during lifetime especially for the structures which can experience resonance such as railway bridges. In this paper, the results of forced vibration tests of different excitation methods (vibration exciter and impact hammer) are compared to examine the differences and the cause of differences of extracted natural frequencies. Consequently a natural frequency modification method is suggested to eliminate effects of non-structural disturbance factors. Also, sequential forced vibration tests are performed before and after track construction according to the construction stage of a railway bridge, and the variation of natural frequencies are examined. Effect of added mass of vibration exciter and variation of support condition due to the level of excitation force are concluded as the major cause of natural frequency differences. Thus eliminating these effects can enhance the reliability of the extracted natural frequencies. Construction of track affects not only the mass of structure but also the stiffness of the structure. Also, the amount of increase in stiffness varies according to the level of structural deflection. Therefore, reasonable estimation of the level of structural response during operation is important for precise natural frequency calculation at design phase.

A Study on Clinical Findings about Vertebral Disease Diagnosed with MRI (MRI로 진단된 척추질환의 임상적 소견)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.157-165
    • /
    • 2006
  • In order to analyze clinical characteristics like sex- and age-based onset frequency and onset region from vertebral disease cases, this study investigated total 1,291 cases of vertebral disease that were diagnosed via magnetic resonance imaging(MRI) from January to December 2004 at B University Hospital in metropolitan area. For higher diagnostic accuracy in cases of spinal disorder diagnosed, this study analyzed findings from data reading conducted by veteran specialists in diagnostic radiology. But this study excluded uncertain lesion cases, the cases requiring differential diagnosis from other disorders and so on from subjects under analysis. This study employed superconductive 1.5 Tesla SIGNA MR/i for MRI test and basically received resulting images via FSE(fast spin echo). In particular, this study obtained T1 and T2 myelogram with regard to regional characteristics(such as cervical vertebrae, thoracic vertebrae and lumbar vertebra) and imaging characteristics for sagittal and transverse section. As a result, this study came to the following conclusions : 1. In terms of general characteristics of subjects under analysis, male group comprised 53.5% and female 46.5% out of total 1,291 subjects. 2. The regional onset frequency of spinal disorders was converged primarily on lumbar vertebra(65.5%), which was followed by cervical vertebrae(27.3%) and thoracic vertebrae(7.0%) respectively. 3. Top 10 cases with high onset frequency of spinal disorders can be listed as follows : 1) posterior bulging disc 65.8% 2) narrowing of neural foramen 23.8% 3) herniated intervertebral disc (HIVD) 22.4% 4) spinal stenosis 16.7% 5) osteochondrosis 6.4% 6) compression fracture 6.4% 7) facet joint arthropathy 6.2% 8) spondylolisthesis 6.0% 9) spinal cord tumor 3.5% 10) inter body fusion 2.6%

  • PDF

Seismic Performance Evaluation of the Li-Polymer Battery Rack System for Nuclear Power Plant (원자력발전소용 리튬폴리머 배터리 랙 시스템의 내진성능평가)

  • Kim, Si-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.13-19
    • /
    • 2019
  • After the Fukushima nuclear accident, a new power supply using a lithium polymer battery has been proposed the first time in the world as the safety of the emergency battery facility has been required. It is required to have the safety of the rack system in which the battery device is installed in order to apply the proposed technology to the field. Therefore, the purpose of this study is to evaluate the seismic performance of string and rack frame for lithium-polymer battery devices developed for the first time in the world to satisfy 72 hours capacity. (1) The natural frequency of the unit rack system was 9 Hz, and the natural frequency before and after the earthquake load did not change. This means that the connection between members is secured against the design earthquake load. (2) he vibration reduction effect by string design was about 20%. (3) As a result of the seismic performance test under OBE and SSE conditions, the rack frame system was confirmed to be safe. Therefore, the proposed rack system can be applied to the nuclear power plant because the rack system has been verified structural safety to the required seismic forces.

Performance Evaluation of the Vibro Hammer with Variable Amplitude by Field Tests (현장실험을 통한 저진동·저소음 진폭가변형 진동해머 성능 평가)

  • Han, Jin-Tae;Lee, Joonyong;Choi, Changho;Park, Jeong-Yel
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.3
    • /
    • pp.1-12
    • /
    • 2015
  • During installing sheet piles for an impermeable wall or a retaining wall, vibratory hammers are widely used. Among vibratory hammers, a hydraulic hammer is used most commonly. However, a hydraulic hammer causes excessive vibration and noise due to resonance by change of natural frequency according to movements of eccentric shaft when the hammer starts and stops. In this study, new variable amplitude type hammer is developed in order to reduce the vibration and noise due to resonance produced in starting and stopping the hammer. By controlling horizontal angle in two pairs of eccentric body inside of the hammer, the amplitude and vibration of the new hammer can be controlled. The performance tests with the new hammer and existing hammers such as the hydraulic hammer and electric hammer are carried out, and the new hammer shows reduced vibration and noise results in comparison with existing hammers from performance tests. Also, this study shows that penetration rates of sheet pile using the new hammer increase due to impellent force of a backhoe in comparison with the electric hammer and penetration rate increase in comparison with a general hydraulic hammer, since the new hammer can control the amplitude during penetration of sheet pile according to soil condition.

Intra-articular Lesions and Clinical Outcomes in Traumatic Anterior Shoulder Dislocation Associated with Greater Tuberosity Fracture of the Humerus

  • Lim, Kuk Pil;Lee, In Seung;Kim, In-Bo
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.195-200
    • /
    • 2017
  • Background: This study investigated and evaluated the clinical outcomes of intra-articular lesions of traumatic anterior shoulder dislocation (TASD) associated with greater tuberosity (GT) fracture of the humerus. Methods: Subjects included 20 patients who were surgically or non-surgically treated for GT fracture of the humeurs with TASD, and followed-up for at least 2 years. The mean follow-up period was 54.1 months (range, 24-105 months). Of the 20 patients, 12 were treated surgically. Intra-articular lesions were identified randomly on magnetic resonance imaging scans (repeated thrice) by experienced radiologists and orthopedic surgeons. The accompanying intra-articular lesions were left untreated. Clinical outcomes were evaluated by Simple Shoulder Test (SST) and Western Ontario Shoulder Instability index (WOSI) at the last follow-up. Results: Intra-articular lesions were identified in 19 patients: 7 Bankart lesions, 15 humeral avulsion of the glenohumeral ligament lesions, 3 glenoid avulsion of the glenohumeral ligament lesion, and 6 inferior capsular tears. Two or more intra-articular lesions were identified in 6 patients. The mean SST score was 10.9 and the mean WOSI score was 449.3 at the last follow-up. Conclusions: For GT fracture of the humerus with TASD, a high frequency of diverse intra-articular lesions was identified. There were no incidence of recurrent shoulder dislocations, and good clinical outcomes were obtained without treatment of the intra-articular lesions. We thereby comprehend that although intra-articular lesions may occur in TASD associated with GT fracture of the humeurs, merely treating the GT fracture of the humerus is sufficient.

Low Temperature Sintering and Microwave Dielectric Properties of Ca[Ti1-x(Ni1/3Nb2/3)x]O3 Ceramics (Ca[Ti1-x(Ni1/3Nb2/3)x]O3 세라믹스의 저온소결 및 마이크로파 유전특성)

  • Lee, Young-Gyu;Kim, Hyo-Tae;Nam, Joong-Hee;Kim, Jong-hee;Paik, Ungyu
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.1 s.284
    • /
    • pp.55-61
    • /
    • 2006
  • The microwave dielectric properties and low temperature sintering of $Ca[Ti_{1-x}(Ni_{1/3}Nb_{2/3})_x]O_3$ system were investigated at the sintering temperature $1,200\~1,350^{\circ}C$. The density and quality factors $(Q{\times}f)$ increased while dielectric constants slightly decreased with the decrease of Ti. The dielectric constant, quality factor, and temperature coefficient of resonance frequency $(\tau_f)$ were 64, 17,000 GHz, and $-9.1\;ppm/^{\circ}C$ respectively, when $CaTi_{1/2}(Ni_{1/3}Nb_{2/3})_{1/2}O_3$ ceramics were sintered at $1,300^{\circ}C$ for 4 h. $2Li_2O-B_2O_3$ was added to $CaTi_{1/2}(Ni_{1/3}Nb_{2/3})_{1/2}O_3$ to decrease the sintering temperature for LTCC application. The microwave dielectric properties of the samples sintered at $925^{\circ}C$ for 2 h with the addition of $6\;wt\%\;2Li_2O-B_2O_3$ were $\varepsilon_r=48.7,\;Q{\times}f=8,460\;GHz$, and $\tau_f=+5.6ppm/^{\circ}C$. Compatibility test of the composition with silver electrode shows no reaction with silver electrode, implying the feasibility as a high-K LTCC material.