• 제목/요약/키워드: frequency counting

검색결과 112건 처리시간 0.054초

점용접 표준시편에 대한 가속내구시험법의 적용 (Application of Accelerated Vibration Testing to Spot-welding Specimen)

  • 김관주;조성신;정진성
    • 한국자동차공학회논문집
    • /
    • 제11권3호
    • /
    • pp.209-213
    • /
    • 2003
  • It is advantage of accelerated vibration testing to compress service exposures to operating vibration into a reduced laboratory test by increasing the amplitude or frequency of the applied input excitations. This paper proposes an accelerated test method to estimate the high-cycle fatigue life under random excitation. The method consists of conducting a test with amplified input excitation and extrapolating linearly the lift in the accelerated condition into the real lift in field condition. The extrapolation is carried out applying the high-cycle irregular excitation fatigue theory including the rainflow counting, Miner’s damage accumulation rule, and Goodman’s mean stress correction. As a verification, those estimated lift is compared with that acquired by experiment f3r the simple case of spot welding specimen with good agreement. This testing procedure will provide an useful scheme that can reduce testing period associated with developing time schedule of new product.

Development of a Simplified Eddy Current Tester Specialized in Non-Iron Metals

  • Zhang, XiaoDong;Tamura, Muneyoshi;Aoyama, Tomoo;Nagashima, Umpei
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.805-808
    • /
    • 2005
  • We constructed an eddy current tester as education programs of electronics and computers. The tester is designed based on frequency counting of square-waves digitally, where information of phase is lost, but which is very compact. Main controller of the tester is PIC16HC84A. Other parts, detection-coils, oscillators, and stabilizers are made by us. The tester is able to detect change of order(-5) in waves of 1MHz, whose function is kept in several minutes. The measurement period is 10-20 msec in the several minutes. Using the tester, we observed narrow gaps of copper/aluminum wires, and detected resistivity difference of 1.7 or 2.7 [$10^{-8}$ $ohm^{\ast}m$].

  • PDF

음운론적 인식과 처리능력이 4-6세 유아의 한글 단어 읽기에 미치는 영향 (Kindergartners' Reading of Words in Hangul : Effects of Phonological Awareness and Processing)

  • 최나야;이순형
    • 아동학회지
    • /
    • 제28권4호
    • /
    • pp.73-95
    • /
    • 2007
  • Causal relationships of kindergarteners' phonological awareness and processing to their ability to read words was investigated with the participation of 289 4- to 6-year-old children attending three kindergartens in Busan. Results showed gradual growth in reading ability with age. Children performed best in reading words and poorest in reading low frequency letters. They showed continuous development in skills of syllable deletion, phoneme substitution, phoneme insertion, phonological memory and naming. Discontinuous development was found in counting syllables. Longer syllables were difficult to count, and middle syllables of 3 syllable words were hard to delete. Children had poor perception of final consonants of Consonant-Vowel-Consonant syllables. Children's phonological awareness and processing were latent variables strongly related to ability to read words written in Hangul.

  • PDF

Keyword Analysis Based Document Compression System

  • Cao, Kerang;Lee, Jongwon;Jung, Hoekyung
    • Journal of information and communication convergence engineering
    • /
    • 제16권1호
    • /
    • pp.48-51
    • /
    • 2018
  • The traditional documents analysis was centered on words based system was implemented using a morpheme analyzer. These traditional systems can classify used words in the document but, cannot help to user's document understanding or analysis. In this problem solved, System needs extract for most valuable paragraphs what can help to user understanding documents. In this paper, we propose system extracts paragraphs of normalized XML document. User insert to system what filename when wants for analyze XML document. Then, system is search for keyword of the document. And system shows results searched keyword. When user choice and inserts keyword for user wants then, extracting for paragraph including keyword. After extracting paragraph, system operating maintenance paragraph sequence and check duplication. If exist duplication then, system deletes paragraph of duplication. And system informs result to user what counting each keyword frequency and weight to user, sorted paragraphs.

RSFQ Toggle Flip-Flop 회로의 최적화를 통한 Program Counter의 개발 (Development of Program counter through the optimization of RSFQ Toggle Flip-Flop)

  • 백승헌;김진영;김세훈;강준희
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권1호
    • /
    • pp.17-20
    • /
    • 2005
  • We has designed, fabricated, and measured a Single flux quantum (SFQ) toggle flip-flop (TFF). The TFF is widely used in superconductive digital electronics circuits. Many digital devices, such as frequency counter, counting ADC and program counter be used TFF Specially, a program counter may be constructed based on TFF We have designed the newly TFF and obtained high bias margins on test. In this work, we used two circuit simulation tools, WRspice and Julia, as circuit optimization tools. We used XIC for a layout tool. Newly designed TFF had minimum bias margins of +/- $37\%$ and maximum bias margins of +/-$37\%$(enhanced from +/- $37\%$). The designed circuits were fabricated by using Nb technology The test results showed that the re-optimized TFF operated correctly on 100kHz and had a very wide bias margins of +/- $53\%$.

HEPATOTOXICITY OF T-2 TOXIN IN RATS

  • Kang, Tae-Gyu;Lee, Yong-Soon
    • Toxicological Research
    • /
    • 제2권2호
    • /
    • pp.89-102
    • /
    • 1986
  • T-2 toxin was given to rats(Spargue Dawley) with a 4mg/kg and 2mg/kg dose p.o. Data was based on the T-2 toxin 4mg/kg treated group except for counting of acidophil bodies. GPT activities increased significantly from 0.5 to 10 hours. GOT activities were also increased at 1 and 5 hours significantly and the relative weights of liver were increased at 0.5 and 5 hours significantly. There were slight necrotic foci in microscopic observation. There was dose-dependent trend for the frequency of the acidophil body between the 4mg/kg treated group and the 2mg/kg treated group.

  • PDF

유체속도 측정을 위한 레이저 도플러 유속계의 구성에 관한 연구 (A Study on the Construction of LDV System for a Measurement of the Fluid Velocity)

  • 최종원;조재흥;정명세
    • 전자공학회논문지A
    • /
    • 제28A권5호
    • /
    • pp.361-369
    • /
    • 1991
  • The optics and the signal processor of dual beam laser Doppler velocimeter(LDV) was fabricated. By using the dual beam and the forward scattering, the optics part of LDV was fabricated. And the signal processor of LDV was designed by the frequency counter type using new 11:6 period timing device in order to remove error signals, and was made of the reference clock of a 500 MHz ECL oscillator. Doppler frequencies from 10KHz to 70MHz can be measured using the signal processor. In the accuracy of the period counting part, from 1.81x10**-4% to 1.27% is estimated, and in the accuracy of the validation logic part, from 0.78% to 14.78% is estimated.

  • PDF

정량적 위험해석을 이용한 크레인 낙하물의 위험성 평가에 관한 연구 (Risk Assessment of Dropped Object in Offshore Engineering through Quantified Risk Analysis)

  • 장철호;이주성
    • 대한조선학회논문집
    • /
    • 제54권2호
    • /
    • pp.143-150
    • /
    • 2017
  • Previous methods to evaluate the risk of dropped objects rely on personnel experience of the engineer or operator without analyzed data. However analyzing historical statistic data is the best approach to find the safest operation route and to achieve more reasonable and reliable calculation results. By counting the failure frequency and fatal accident rate the risk can be quantified, and so controlled or mitigated with best economical risk reducing measures. This analysis gives a crane operator with useful information for selecting the best crane operation route, and a designer with an estimation of risk level for the dropped objects from a safety point of view.

회전 진동 교정 장치 구현을 위한 고정밀 측정기법에 대한 연구 (Study on the Precision Method of Measuring angular displacement for the Angular Vibration Calibration System)

  • 정완섭;이용봉;이두희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.685-688
    • /
    • 2004
  • This paper addresses the study on developing the angular vibration calibration system which requires the highly accurate measurement technique of the amplitude and period of an oscillating angular motion. Two developed models for the low and high frequency ranges are introduced and their main features are also compared. In addition to the angular vibration exciters, a new measurement method, referred to the 'equi-angle sampling method', is proposed and its theoretical backgrounds are introduced. The proposed method is shown to provide much less measurement uncertainty, compared the fringe counting method. Experimental results demonstrate what amount of angular vibration amplitude measurement uncertainty is improved by suing the proposed equi-angle sampling method.

  • PDF

Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma

  • Alexander Rau;Jakob Neubauer;Laetitia Taleb;Thomas Stein;Till Schuermann;Stephan Rau;Sebastian Faby;Sina Wenger;Monika Engelhardt;Fabian Bamberg;Jakob Weiss
    • Korean Journal of Radiology
    • /
    • 제24권10호
    • /
    • pp.1006-1016
    • /
    • 2023
  • Objective: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). Materials and Methods: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. Results: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). Conclusion: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.