• Title/Summary/Keyword: freezing condition

Search Result 303, Processing Time 0.025 seconds

Changes in Insulation Performance of Organic Insulating Materials for Building Construction by Accelerated Durability Test Conditions (가속내구성 조건에 따른 건축용 유기계 단열재의 단열성능 변화)

  • Lim, Soon-Hyun;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.595-601
    • /
    • 2016
  • The insulation performance of the insulation currently used in building structures is reflected only during design based on initial performance and the reduction in heat insulation performance due to the degradation of long-term durability is not reflected. This study reviewed the degradation of heat insulation performance due to the durability degradation of insulating materials through the accelerated durability test. The study findings showed that the foamed polystyrene insulation bead method did not show performance degradation due to aging in the standard environmental condition and laboratory accelerated test condition but the performance is degraded in the freeze-thaw test condition. On the other hand, in the case of the extrusion method, the degradation of the heat insulation performance was less in the freeze-thaw test condition, but the rapid performance degradation was caused by the release of the internal gas at the beginning of aging. In addition, the hard polyurethane foam insulation showed better initial insulation performance than other insulation materials, but the performance was found to be degraded somewhat under laboratory accelerated test conditions and freeze-thaw test conditions.

Evaluation of the Shear Strength and Stiffness of Frozen Soil with a Low Water Content (함수비가 낮은 동결토의 전단강도 및 강성 평가)

  • Kim, Sang Yeob;Lee, Jong-Sub;Kim, Young Seok;Byun, Yong-Hoon
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.93-102
    • /
    • 2015
  • The characteristics of frozen soils are one of most important factors for foundation design in cold region. The objective of this study is to evaluate the shear strength and stiffness of frozen soils according to the confining conditions during the freezing and shearing phase. A direct shear box is constructed for the frozen specimens and bender elements are mounted on the wall of the shear box to measure shear wave velocities. Specimens are prepared by mixing sand and silt with a silt fraction of 30% in weight and the degree of saturation of 10%, giving a relative density of 60% for all tests. The temperature of the specimens in the freezer is allowed to fall below -5℃, and then direct shear tests are performed. A series of vertical stresses are applied during the freezing and shearing phase. Shear stress, vertical displacement, and shear wave along the horizontal displacement are measured. Experimental results show that in all the tests, shear strength increases with increasing vertical stress applied during the freezing and shearing phases. The magnitude of the increase in shear strength with increasing vertical stress during shearing under fixed vertical stress in the frozen state is smaller than the magnitude of the increase in vertical stress during freezing and shearing. In addition, the change in shear wave velocities varies with the position of the bender elements. In the case of shear waves passing through the shear plane, the shear wave velocities decrease with increasing horizontal displacement. This study provides an evaluation of the properties of shear strength and stiffness of frozen soils under varied confining condition.

Residual Shear Strength Evaluation for RC Beam Member (RC 보 부재의 잔존 전단강도 평가)

  • Myung, Gun-Hak;Rhee, Chang-Shin;Kim, Dae-Joong;Mo, Gui-Suk;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.283-286
    • /
    • 2005
  • Recently, the deterioration of concrete structures have been increased by the damage from salt, carbonization, freezing & thawing and the others. Reinforcement corrosion is the principal cause of deterioration of reinforced concrete. Unfortunately, full bond is assumed in all existing shear models, a condition which is often not fulfilled when assessing damaged structures. It is therefore very important to increase the understanding of how reduced bond influences the load carying capacity particularly for shear. Therefore in this study an equation is proposed to evaluate the residual shear strength considered deterioration.

  • PDF

Evaluation of Durability of Highstrength Light-weight Aggregate Concretes (고강도 경량골재 콘크리트의 내구성에 관한 연구)

  • 김광우;이상범;조회원;정규동;이석홍
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.416-421
    • /
    • 1997
  • This study was conducted to evaluate durability of high-strength light-weight aggregate concretes which are increasingly demanded recently. Two different artificial light-weight aggregates were used and two levels of high-strength concretes were made using w/c of 33% and 37% for target strength of 500kg/$\textrm{cm}^2$ and 400kg/$\textrm{cm}^2$, respectively. Cylinder specimens($\phi$=10cm and h=20cm) were made and treated with freezing-and-thawing(F/T) cycle at $-18^{\cire}C$ and $4^{\cire}C$. Dynamic modulus of elasticity and surface condition were evaluated with F/T cycle increase. The results showed that durability of the light-weight aggregate concretes was worse than that of conventional concrete, and the light-weight high-strength concrete with w/c=37% had the better durability than the one with w/c=33%.

  • PDF

An Experimental Study on the Improvement of Durability for the Foundation Concrete under Cold Weather Condition (혹한지역 기초 콘크리트의 내구성 향상을 위한 실험 연구)

  • 우상균;송영철;김경민;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.645-650
    • /
    • 2003
  • The purpose of this study is to provide the optimum mix design of cold weather concrete to be placed at the foundation structures in substation. The basic performance tests including slump and slump flow, air content, compressive strength and freezing & thawing resistance were conducted for cold weather concrete by varying with W/C ratios such as 40%, 50% and 60% and air contents such as 3%, 4%, 5% and 6%. The effect on durability of concrete corresponding to the increasing amount of air content and W/C ratio was evaluated and the optimum mix design was recommended. From this study, the concrete mix design containing 6% of air content and 45% of W/C ratio is recommended for the foundation concrete of substation.

  • PDF

Factor Analysis of Deterioration in Namhansanseong Yeojang (남한산성 여장 손상원인 분석)

  • Chung, Kwang-Yong;Lee, Sang-Ok;Yang, Hee-Jae
    • Journal of architectural history
    • /
    • v.25 no.1
    • /
    • pp.59-68
    • /
    • 2016
  • There are many reasons of damage in Namhansanseong Yeojang. Lots of damage types are observed in each Yeojang. There are many types of damage factors but major damage factor is breakage by freezing and thawing. So Conduct non-destructive evaluation about damage factors in Namhansanseong Yeojang to analysis weathering factors in Yeojang by measuring directional microclimate. The study will pave the way for conservation management in Namhansanseong by suggesting the conservation calendar about weather condition and damage factors.

Robust Self-Tuning Regulator without Persistent Excitation (지속여기 조건이 없는 강인한 자조 안정기)

  • 김영철;이철희;양흥석
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.11
    • /
    • pp.1207-1218
    • /
    • 1990
  • The lack of persistent excitation (PE) can be the reason of freezing in the recursive least square estimators and the covariance windup in the exponential weighted least square estimators. We present a theoretical analysis of these phenomena and a simple method to check the exciting condition in real time. Using these results and under some conditions such as slowly time varying Plant and a tracking problem for set point, a robust self-tuning regulators without PE is proposed. In this algorithm, when PE is not satisfied, only plant gain is estimated, and then the system parameters are corrected by it. It is shown that the gain adaptive scheme makes the robustness to be improved against modeling error, off-set, and correlated noise etc, by the results of analysis and simulations.

Properties of Strength Development Under Various Curing Condition at Early Age of Cement Mortar Using Agent for Enduring Cold Weather (내한성 혼화제를 이용한 시멘트 모르타르의 초기양생 온도변화에 따른 강도증진 특성)

  • Han, Cheon-Goo;Hong, Sang-Hee;Kim, Hyun-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.191-197
    • /
    • 2001
  • In this study, the admixtures for agents for enduring cold weather used widely are collected and applied to cement mortar to analyze the strength development due to variation of curing temperature at early age. The test results show that anti-freezing admixture have some problems due to high chloride content, which may cause the corrosion of reinforcement embedded in concrete. However, the mortar applied by accelerator and another kind of agent for enduring cold weather produced by S company lead to delay of strength development in low temperature. Also, it is clarified that there are no significant problems for cement mortar in strength development due to low temperature if a suitable kind of agent enduring cold weather is used and cement mortar is cured for more than $7.5^{\circ}D.D$ at early age.

  • PDF

A Study on the Characteristics of the Refrigerator Using a Refrigerant Injection Type Expansion Device (냉매분사식 팽창장치를 적용한 냉동기의 특성에 관한 연구)

  • 조병옥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.925-931
    • /
    • 2000
  • Refrigerating ability of vapor compression refrigerator is decided by the harmonic work of it's components such as compressor, condenser, evaporator, expansion device, and so on. In this study, choosing refrigerant injectors as a new one of expansion device, temperature change of the cold room, ice freezing ability, and power consumption on flowrate of injector and refrigerant charging condition are evaluated experimentally. As the results of this study, it is verified that the spray injection type refrigeration system has some merits according to the flowrate and spray pattern of injector and charging quantum of refrigerant. And there are some design factors such as spray pattern and shape of spray chamber to utilize and fabricate this refrigerant injection type refrigerator.

  • PDF

Super-cooled State Cloud Generation System Development for T-50 Supersonic Jet Trainer Icing Test (T-50 고등훈련기 빙결시험을 위한 과냉각구름 생성시스템 개발)

  • Lee, Cheol;Jeon, Cheol-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.580-586
    • /
    • 2008
  • Icing cloud generation system was developed to perform the in-flight icing simulation test for T-50 Supersonic Jet Trainer on the ground. The developed system successfully generated the almost natural icing cloud in the super-cooled state (liquid state) below freezing point and with the required LWC (Liquid Water Content). For full-scale aircraft icing test, an icing scaling method was adopted due to the limitation of wind generation speed with open-circuit type blower and its applicability was experimentally verified. Under the required in-flight icing condition based on the icing scaling method, T-50 aircraft subsystems were successfully operated and functionally checked.