• Title/Summary/Keyword: freezing air temperature

Search Result 159, Processing Time 0.119 seconds

Measurement of the Surface Heat Transfer Coefficients for Freezing Time Prediction of Foodstuffs (식품의 동결시간 예측을 위한 표면열전달계수 측정)

  • Jeong, Jin-Woong;Kong, Jai-Yul;Kim, Min-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.735-741
    • /
    • 1989
  • For the accurate prediction of freezing time, probably the most difficult factor to measure and major error source is the surface heat transfer coefficient. In this work, surface heat transfer coefficient were determined for still air freezing and immersion freezing methods by theory of the transient temperature method and confirmed by using a modification of plank's equation to predict the freezing time of ground lean beef. The results showed the cooling rate of immersion freezing was about 11 times faster than that of still air freezing method. A comparison of surface heat transfer coefficient of copper plate and ground lean beef resulted an difference of 25-30% because the food sample surface is not smooth as copper plate. Also, when h-values measured by ground lean beef were applicated to modified model, the accuracy of its results is very high as difference of about 8%.

  • PDF

Three Cases with the Multiple Occurrences of Freezing Rain in One Day in Korea (12 January 2006; 11 January 2008; and 22 February 2009)

  • Park, Chang-Kyun;Byun, Hi-Ryong
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.31-49
    • /
    • 2015
  • From the hourly data of 75 Korean weather stations over a 12-year period (2001~2012), this study has chosen three cases (January 12, 2006; January 11, 2008; and February 22, 2009) of multiple freezing rains and investigated the atmospheric circulations that seemed to cause the events. As a result, the receding high pressure type (2006), prevailing high pressure type (2008), and warm front type (2009) are confirmed as synoptic patterns. In all three cases, freezing rain was found in regions with a strong ascending current near the end point of a low-level jet that carried the warm humid air from low latitudes. The strong ascending current resulted from lower-level convergence and upper-level divergence. In 2006 and 2009, the melting process was confirmed. In 2008, the supercooled warm rain process (SWRP) was confirmed. In contrast to existing SWRP theory, it was found that the cool air produced at the middle atmosphere and near the earth's surface led to the formation of freezing rain. The sources of this cool air were supposed to be the evaporative latent heat and the cold advection coming from the northeast. On the other hand, a special case was detected, in which the freezing rain occurred when both the soil surface temperature and surface air temperature were above $0^{\circ}C$. The thickness distributions related to freezing rain in Korea were found to be similar to those in North America. A P-type nomogram was considered for freezing rain forecasting; however, it was not relevant enough to Korea, and few modifications were needed.

Freezing of Micro-size Water Droplet on Micro Porous Surface (박판형 미세다공 표면에서의 미소액적의 동결)

  • Park, Chun-Wan;Lee, Dong-Gyu;Peck, Jong-Hyeon;Kang, Chae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.173-178
    • /
    • 2011
  • Gas diffusion layer(GDL) in PEMFC performs the discharge of water vapor smoothly. When GDL is revealed to cold environment, the freezing of the water droplet or water net in GDL occurs. The purpose of this work is to observe the cooling and freezing behavior of the water droplet which meets to the microporous surface and air under the various low temperature conditions. GDL was coated with waterproof material, which has three types of coating rate, 0, 40 and 60%. Water droplets in series of sizes on GDL were supercooled, frozen and crystalized orderly by circulating low temperature brine. The process of cooling was investigated with the temperature and the snapshot of the water droplet.

A Study on the Airflow near the Cold Heat Source Using CFD in Merchandising Store (CFD를 이용한 대형매장 냉열원 주변의 공기유동에 관한 연구)

  • Cho Sung Woo;Park Min Young;Im Young Bin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.629-634
    • /
    • 2005
  • This paper performed to predict vertical temperature distribution and air flow near cold heat source in the mass merchandising store. At the height of 150 cm, the vertical air temperature difference between the results of CFD and of measurement field showed $10\%$ near the refrigeration zone and $8.8\%$ near the freezing zone. Therefore, it regarded as appropriate for the using CFD to investigate airflow near the heat sources. The 3 kinds of CFD model were divided by the disposition of diffuser/exhaust and diffuser air temperature. At the refrigeration and freezing zone in the Model 2 and 3, the temperature difference between the front and the back of human model were showed $6.8^{\circ}C\;and\;3.9^{\circ}C$ with diffuser air temperature $17^{\circ}C$ and were showed $6.8^{\circ}C$ and $4^{\circ}C$ with diffuser air temperature $19^{\circ}C$.

Fluid flow in the freezing compartment of the B/F Refrigerators (B/F형 냉장고 냉동실의 결빙원인에 관한 연구)

  • Yang, S.Y.;Kim, Y.K.;Park, J.S.;Jung, H.Y.;Lee, Y.W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.530-533
    • /
    • 2008
  • Refrigerators have some frost related problems in a freezing compartment. The frost formation in the refrigerator gives customers a bad impression concerning quality problems. Therefore, many engineers have been studying the optimum solution to avoid frost formation. But the problem of frost formation is very complex and hard to approach to the answer. The frost generation of a household refrigerator have been widely known that is closely related to the distribution of temperature inside the compartment. The distribution depends on the cold air circulation inside the refrigerator. So frost problem can be reduced and energy consumption efficiency also improved through optimization of air flow fields inside the freezing compartment. In this paper, numerical simulation has been carried out to check fluid flow. The variation of temperature at the walls was measured and quantitative analysis of frost generated from the freezing compartment was carried out. Through comparison between simulation and experiment, some correlation revealed.

  • PDF

On Study of Summertime Ice Formation in the Ice Valley at Unchiri, Gangwon-Province (강원도 정선군 운치리 얼음골의 여름철 결빙현상에 관한 연구)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.857-863
    • /
    • 2002
  • The meteorological elements were measured to investigate cause of summertime ice formation at Unchiri, Gangwon Province. The cause of freezing at valley was conformed as adiabatic expansion theory, latent heat of evaporation, natural convective theory, cold air remain theory, and convective freezing theory according to former study. However nither theory produced a satisfactory explanation. This studying area is not valley but ridge, and underground water surface exists at below than freezing height. wintertime temperature drop and summertime cold air spouting were explain as natural convective theory, generation of water drop on the rock was explained as cooling theory by air expansion, and ice formation on the rock was explained as adiabatic expansion theory. In conclusion, formation of ice valley at Unchiri was formed by natural convective theory, adiabatic expansion theory, and latent heat of evaporation successively.

An Experimental Study on the Freezing and Thawing of Concrete Mixed with Steel Slag (제강 슬래그를 이용한 콘크리트의 동결융해에 대한 실험적 연구)

  • 정원섭;조성현;권기주;박성우;김진만
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.48-53
    • /
    • 2003
  • The steel slag, a by-product which is produced on the process of manufacturing steel by refining pig iron is mainly used as road materials after aging it. It is necessary to age steel slag for long time in air because the reaction with water and free-CaO in steel slag could make the volume expanded. Due to this reason it prevents steel slag from being used as aggregate of concrete. But steel slag used in this study is controled by a air-jet method which rapidly cools substance melted at a high temperature. Rapid cooling prevents from generating of free-CaO in steel slag. In this study, it was investigated that steel slag manufactured by air-jet method affects on concrete in the freezing and thawing. As results of this study, concrete mixed with steel slag was worse in the freezing and thawing than concrete mixed with sand in spite of using air entraining agent. To obtain durability of concrete in the freezing and thawing, it is desirable to mix 50% of steel slag in concrete per unit weight of volume.

  • PDF

A Study on the Development of Heat-Recovery Ventilator for Preventing Freezing in a Cold Weather (혹한기 결빙 방지를 위한 열회수형 환기장치 개발에 관한 연구)

  • Park, Woo-Cheul;Kim, Il-Gyoum;Tae, Kyung-Eung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.593-598
    • /
    • 2018
  • Computational fluid dynamics was used to develop a heat-recovery ventilator for preventing freezing in cold weather. An optimal internal return damper was applied, and a prototype was made for frost and freezing experiments. A total of 16 models were used to design the optimal internal return damper with the maximum exhaust recirculation ratio. The exhaust recirculation ratio of the exhaust air to the outdoor air was 59.9-62.3%. The tests showed that frost and freezing did not occur at outdoor air temperatures of $-15^{\circ}C$ or higher in both exhaust recirculation operation and normal operation. However, at an outdoor air temperature of $-20^{\circ}C$, no freezing occurred in the outdoor air area when the internal return damper was opened by 45 degrees. Heat recovery ventilators for preventing cold weather frost and freezing should be operated in two operation modes: normal and exhaust recirculation mode. An operating algorithm was developed for the heat-recovery ventilator operating in normal mode when the outdoor temperature is higher than $-15^{\circ}C$ and recirculation mode when the temperature is lower.

Quality Characteristics of Wheat Flour Breads with the Doughs Frozen at the Different Freezing and Storage Conditions (반죽의 냉동과 저장 조건에 따른 빵의 품질 특성)

  • Koh, Bong-Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.413-418
    • /
    • 2002
  • The dough was frozen either before or after fermentation at the five different freezing and storage conditions. Although fermentation before freezing was effective for rapid freezing, it reduced bread volume of the dough frozen at both air freezer and liquid immersion freezer. Freezing at the air freezer set to $-70^{\circ}C$ took more time for freezing and resulted in lower bread volume than freezing at the immersion freezer set to $-20^{\circ}C$. Therefore, the freezing in the liquid immersion freezer was more effective to reduce the freezing time and increase the bread volume. At the liquid immersion freezer, the higher temperature was more effective than lower temperature. The doughs frozen in a liquid immersion freezer set to $-10^{\circ}C$ and fermented after de-frosting produced higher bread volume than control unfrozen dough. And also there was no significant difference in bread volume between the control unfrozen dough and the dough frozen in a liquid immersion freezer set to $-10^{\circ}C$, fermented before freezing and re-fermented after defrosting. The longer proof time and greater loaf volume obtained for the dough frozen and stored at the air freezer set to $-70^{\circ}C$. Therefore the optimum process for freezing the dough was freezing immediately after mixing, storing at $-10^{\circ}C$ in a liquid immersion freezer and fermented after defrosting.

Effects of Deep Freezing Temperature for Long-term Storage on Quality Characteristics and Freshness of Lamb Meat

  • Choi, Mi-Jung;Abduzukhurov, Tolibovich;Park, Dong Hyeon;Kim, Eun Jeong;Hong, Geun-Pyo
    • Food Science of Animal Resources
    • /
    • v.38 no.5
    • /
    • pp.959-969
    • /
    • 2018
  • This study investigated the effects of deep freezing and storage temperature ($-50^{\circ}C$, $-60^{\circ}C$, and $-80^{\circ}C$) on the quality and freshness of lamb. To compare the qualities of deep frozen and stored lamb, fresh control and normal freezing conditions ($-18^{\circ}C$) were adopted. As quality and freshness parameters, drip loss (thawing loss and cooking loss), water-holding capacity (WHC), texture profile analysis (TPA), thiobarbituric acid reactive substances (TBARS), and total volatile basic nitrogen (TVBN) were evaluated during 5 months of storage. Temperature influenced the drip loss and WHC, and deep freezing minimized the moisture loss during frozen storage compared to the normal freezing condition. Lamb frozen and stored at deep freezing temperature showed better tenderness than that stored in normal freezing conditions. In particular, lamb frozen at lower than $-60^{\circ}C$ exhibited fresh lamb-like tenderness. Regardless of temperature, evidence of lipid oxidation was not found in any frozen lamb after 5 months, while TVBN was dependent on the applied temperature. Therefore, this study demonstrated that deep freezing could potentially be used to maintain freshness of lamb for 5 months. From the quality and economic aspects, the freezing and storage condition of $-60^{\circ}C$ is estimated as the optimum condition for frozen lamb.