• Title/Summary/Keyword: freezer

Search Result 211, Processing Time 0.026 seconds

Effect of Freezing and Thawing Methods on Duck Meat Characteristics (냉동과 해동 방법이 오리고기의 특성에 미치는 영향)

  • Heo, Kang-Nyeong;Kim, Ji-Hyuk;Kim, Sang-Ho;Kang, Bo-Seok;Kim, Chong-Dae;Cha, Jae-Beom;Hong, Eui-Chul
    • Korean Journal of Poultry Science
    • /
    • v.43 no.4
    • /
    • pp.197-206
    • /
    • 2016
  • This work was carried out to investigate effects of the freezing/thawing method on duck meat kept in a freezer for a month. The meats used were breast muscle collected from Korean native ducks (KND) that were fed for 8 weeks (2.8 kg of live weight). Forty-five samples were used after being frozen in storage for one month and were then divided into 5 treatments (3 replications/treatment, 3 samples/replication). Five treatments (CON, FFFT, FFST, SFFT and SFST) were control groups (CON) and four were experimental groups, using $2{\times}2$ complex factors with two freezing methods (fast freezing, FF, $-50^{\circ}C$ in a deep freezer; slow freezing, SF, $-20^{\circ}C$ in a common freezer) and two thawing methods (fast thawing, FT, 5 h $12^{\circ}C$ with flow water; slow thawing, ST, 24 h $5^{\circ}C$ in a refrigerator). Lightness of KND meat in FF and FT groups was lower than that of control (P<0.05). Yellowness of KND meat of the ST group was higher than that of control (P<0.05). Cooking loss (CL) and water holding capacity (WHC) of KND meat in the control were lower than those of the freezing and thawing groups (P<0.01, P<0.05), but shear force (SF) of the control was higher than that of other groups (P<0.01). Moisture content of the ST group was higher than that of the FT group (P<0.05), and protein content of the FF group was higher than that of control (P<0.05). Stearic acid (C18:0) of the SF group was higher than that of the FF group (P<0.05). Arachidonic acid (C20:4n6) of control was higher than that of the SF and ST groups (P<0.01, P<0.05). Alanine, aspartic acid, glutamic acid, serine, and tyrosine content of the control were lower than that of the freezing and thawing groups (P<0.05). These results show that freezing and thawing methods affect meat color, shear force, cooking loss, and WHC-related water content.

Development of Rabbit Brain Tumor Model Using VX2 Cells and Verification with the MRI in Neuroradiologic Research (Neuroradiology 연구를 위한 VX2 세포를 이용한 토끼 뇌종양 모델 제작과 MRI를 이용한 검증)

  • Yong-Woo Kim;Seon Hee Choi;Hak Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.441-453
    • /
    • 2023
  • Purpose To evaluate the development, location, and volume of a VX2 carcinoma using four inoculation methods in a rabbit brain. Materials and Methods Inoculation of a VX2 cell suspension was performed 1) on the appointed day, 2) seven days after storing a VX2 carcinoma in a freezer or 3) seven days after storing a VX2 carcinoma in a deep freezer after sacrificing the donor rabbits. 4) Without sacrificing the rabbits, the VX2 cell suspension was obtained using a gun biopsy, inoculation was performed on the appointed day. MR imaging was performed 10 days after inoculation. Brain tissues were obtained the day after. The development, location, and volume of the tumor were evaluated. Results Seventeen of the 18 rabbits inoculated on the appointed day developed tumors (average tumor volume, 106.32 mm3). One of five inoculated seven days after storing the VX2 tumor in the freezer, and three of five inoculated seven days after storing the VX2 tumor in the deep freezer developed tumors. Inoculation with a VX2 cell suspension obtained with a gun biopsy from five rabbits revealed development of tumors in only two rabbits. The tumors mostly developed in the superficial cortex. Conclusion TVX2 rabbit brain tumor model is easy to develop and revealed variable reproducibility. This model can be applicable in radiologic imaging, treatment planning, interventional treatment and drug delivery research. VX2 cell can be successfully innoculated into the brain using variable methods under researcher's variable conditions.

Cryopreservation of Suspension Cultures of Camptotheca acuminata

  • Kim, Sung-Hye;Byun, Sang-Yo
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.3
    • /
    • pp.327-332
    • /
    • 2000
  • Supended cells of Camptotheca acuminata were observed to lose their ability to synthesize camptothecin and its derivatives as a result of repeated cultures. Accordingly, the maintenance of high-yield cells by cryopreservation was sudied to overcome this stability problem, and various factors involved were optimized. Pregrowing the cells in 8% myoinositol for 4 days was found to be the most effective in improving survival. The highest survival was obtained when the pregrown cells were cryoprotected with a mixture of 10% DMSO, 0.6M mannitol, and 10% glycerol. When the cryopreserved cells were maintained in a freezer at $-70^{\circ}C$, 94% survival was obtained after 4 months. The survivals after 5 and 8 months of storage decreased to 52% and 45%, respectively. No loss of biosynthetic capacility of camptothecin was observed after short to medium term cryopreservation of C. acuminata.

  • PDF

Optimization of Frosting Performance of a Fin-Tube Heat Exchanger (휜-관 열교환기의 착상 성능 최적화)

  • Yang Dong-Keun;Lee Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.974-980
    • /
    • 2005
  • The optimization of design factors on the frosting performance of a fin-tube heat exchanger is carried out using Taguchi method. The fin spacings of the heat exchanger are selected as design factors. Optimum values of the design factors under operating conditions of a household refrigerator/freezer are proposed. The average heat transfer rate and operating time of the optimum models, compared to those of a reference model, are increased at most by $6.5\%$ and $12.9\%$, respectively.

Effect of Cooking, Reheating Methods and Storage Conditions on the Quality Characteristics of ′Nuhbiani′ (조리, 재가열 방법 및 저장 조건이 너비아니 품질 특성에 미치는 영향)

  • 김정원;김희섭
    • Korean journal of food and cookery science
    • /
    • v.11 no.5
    • /
    • pp.494-502
    • /
    • 1995
  • The study was conducted to evaluate the characteristics of Nuhbiani qualities with the different cooking, reheating methods and storage conditions. Cooking and reheating methods were used with pan, microwave and their combinations. Precooked samples were stored for 0, 1, 4, 7, 15 days in the refrigerator and for 15, 30 days in the freezer. TBA value, shear value by rheometer and sensory attributes in rancidity, hardness, juiciness and overall acceptability were measured. There was no significant difference between cooking, reheating methods in TBA values. Lower values in TBA were noted in the Nuhbiani of frozen storage as compared with that of refrigerated storage. There is a tendency that TBA values were increased as the storage time extended during the refrigeration. Shear values were more increased by microwave cooking and microwave reheating than other methods showing harder texture. Results from sensory evaluation of rancidity, hardness, juiciness and overall acceptability show that there were no significant differences between storage methods, among storage periods and cooking, reheating methods.

  • PDF

Microsurgical Training using Reusable Human Vessels from Discarded Tissues in Lymph Node Dissection

  • Ishii, Naohiro;Kiuchi, Tomoki;Oji, Tomito;Kishi, Kazuo
    • Archives of Plastic Surgery
    • /
    • v.43 no.6
    • /
    • pp.595-598
    • /
    • 2016
  • The use of human vessels at the beginning of microsurgery training is highly recommended. But vessels with the appropriate length for training are not often obtained. Whether these vessels may be reused for training has not been reported. Accordingly, we harvested vessels from discarded tissues in lymph node dissection and demonstrated that vascular anastomosis training using the same human vessels several times is possible by placing the vessels in a freezer and defrosting them with hot water. Vascular walls can be stored for microsurgical training until about 4 years after harvest, as shown in the gross appearance and histologic findings of our preserved vessels. We recommend the technique presented here for the long-term reuse of human vessels for microsurgery training that closely resembles real procedures.

Identification and Reduction Method for Refrigerator Contraction and Expansion Noise (냉장고 수축팽창 소음원의 규명과 저감 방법)

  • Kim, Wonjin;Park, Seong Kyu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.4
    • /
    • pp.723-729
    • /
    • 2013
  • The contraction and expansion noise of a refrigerator are investigated, and some effective methods are proposed to reduce the level and occurrence frequency of noise. First, the noise of a refrigerator is measured to estimate the frequency spectrum and occurrence frequency of noise. Second, a sound visualization was conducted using an acoustic camera to determine the location of the noise source. From the results, it was observed that the internal part mainly producing noise was the third shelf in the freezer room. A method to estimate the acceleration on the location of the noise source is introduced to analyze the contraction and expansion noise precisely and accommodate experimental convenience. Noise reduction methods such as the replacement of the existing shelf with glass shelves, adoption of rail slides, and increase of roughness on the contact surface of the shelf are proposed and tested.

Studies on Simplified Procedures for Freezing and Thawing of Bovine Embryos VI. Effects of freezing procedures in a liquid nitrogen container on the survival rate of mouse embryos (육우수정란 간역동결 및 융해방법에 관한 연구 제육보. 내동제에 Sucrose 첨가에 따른 액체질소에 미치는 영향)

  • 이중계;이규훈;강만종;김영훈;문성호;김승호
    • Korean Journal of Animal Reproduction
    • /
    • v.12 no.2
    • /
    • pp.77-83
    • /
    • 1988
  • This study was done with mouse embryo to assess effects of freezing media containing sucrose, freezing metods(1-F, 0.3$^{\circ}C$/min;2-F, 3-5$^{\circ}C$/min;3-F, 15$^{\circ}C$min;4-F, LN2 vapour) and cell freezers on the embryo survival determined using the FDA test. The results are summarized as follows. 1. The FDA score obtained with 1, 2, 3 and 4-F was 3.8, 3.6, 3.2 and 3.2, respectively. There was a significant difference(P<0.05) between 1-F, 3-F and 2-F, 4-F. 2. The score at the morular stage(3.8) higher(P<0.005) than the blastocyst stage of embryos(3.2). 3. No difference (P>0.05) was found between the score obtained with a automatic embryo freezer(4.0) and a liquid nitrogen container(3.7).

  • PDF

Simulation for Improvement of Temperature Distribution Inside Refrigerator (냉장고 고내 온도산포 개선에 관한 전산모사)

  • Gao, Jia-Chen;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.12
    • /
    • pp.98-103
    • /
    • 2019
  • With the increasing need for environmental protection, it is particularly important to improve the energy saving and reliability of refrigerators. Generally, the cold air flowing into the freezer compartment transits to the bottom of the refrigerating compartment, which can lead to uneven temperature distribution. This paper proposes two design solutions for improving the temperature distribution problem. Of these, the optimal refrigeration design was selected and tested using Computational Fluid Dynamics (CFD) modeling and simulation. The results showed improved uniformity of the temperature distribution inside the refrigerator, thus benefitting food storage while reducing energy consumption.

Thermal Performance Analysis of Reciprocating Compressors for Refrigerator-freezers (냉장고용 왕복동 압축기의 성능 해석)

  • KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.2
    • /
    • pp.236-243
    • /
    • 2016
  • This paper presents a simple thermo-physical model of reciprocating compressors for household refrigerator-freezers. The compressor model has been developed based on thermodynamic principles and large data sets from the compressor calorimeter tests. The input data are compressor geometry (displacement and clearance volume), compressor speed, suction pressure and temperature, discharge pressure, and ambient temperature. The model can estimate mass flow rate and compressor power consumption within 3.0% accuracy, which is not much larger than measurement errors associated with calorimeter testing under ideal conditions.