• 제목/요약/키워드: freeze-thaw cycle

검색결과 79건 처리시간 0.021초

Compressive behavior of concrete under high strain rates after freeze-thaw cycles

  • Chen, Xudong;Chen, Chen;Liu, Zhiheng;Lu, Jun;Fan, Xiangqian
    • Computers and Concrete
    • /
    • 제21권2호
    • /
    • pp.209-217
    • /
    • 2018
  • The dynamic compressive behavior of concrete after freezing and thawing tests are investigated by using the split Hopkinson pressure bar (SHPB) technique. The stress-strain curves of concrete under dynamic loading are measured and analyzed. The setting numbers of freeze-thaw cycles are 0, 25, 50, and 75 cycles. Test results show that the dynamic strength decreases and peak strain increases with the increasing of freeze-thaw cycles. Based on the Weibull distribution model, statistical damage constitutive model for dynamic stress-strain response of concrete after freeze-thaw cycles was proposed. At last, the fragmentation test of concrete subjected to dynamic loading and freeze-thaw cycles is carried out using sieving statistics. The distributions of the fragment sizes are analyzed based on fractal theory. The fractal dimensions of concrete increase with the increasing of both freeze-thaw cycle and strain rate. The relations among the fractal dimension, strain rates and freeze-thawing cycles are developed.

콘크리트 구조물의 반복적 동결융해에 의한 확률론적 열화예측모델 (Probabilistic Prediction Model for the Cyclic Freeze-Thaw Deteriorations in Concrete Structures)

  • 조태준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.957-960
    • /
    • 2006
  • In order to predict the accumulated damages by cyclic freeze-thaw, a regression analysis by the Response Surface Method (RSM) is used. RSM has merits when the other probabilistic simulation techniques can not guarantee the convergence of probability of occurrence or when the others can not differentiate the derivative terms of limit state functions, which are composed of random design variables in the model of complex system or the system having higher reliability. For composing limit state function, the important parameters for cyclic freeze-thaw-deterioration of concrete structures, such as water to cement ratio, entrained air pores, and the number of cycles of freezing and thawing, are used as input parameters of RSM. The predicted results of relative dynamic modulus and residual strains after 300 cycles of freeze-thaw for specimens show very good agreements with the experimental results. The RSM result can be used to predict the probability of occurrence for designer specified critical values. Therefore, it is possible to evaluate the life cycle management of concrete structures considering the accumulated damages by the cyclic freeze-thaw by the use of proposed prediction method.

  • PDF

콘크리트 동결-융해 손상의 비파죄 평가를 위한 One-Sided 응력파 속도 측정기법의 적용에 관한 연구 (Application of One-Sided Stress Wave Velocity Measurement Technique to Evaluate Freeze-Thaw Damage in Concrete)

  • 이준현;박원수
    • 비파괴검사학회지
    • /
    • 제20권4호
    • /
    • pp.269-275
    • /
    • 2000
  • 동결-융해 피로로부터 발생되는 손상이 콘크리트의 열화 및 붕괴를 초래하는 중대한 문제가 된다는 것은 이미 널리 알려져 있다. 일반적으로 동결-융해 피로가 지속되면 콘크리트의 미시조직에 내부응력과 크랙을 유발시킨다. 본 연구에서는 콘크리트에서의 동결-응해 손상을 평가하기 위해 종파와 표면파속도를 동시에 측정하는 one-sided 응력파 속도측정기법이라는 새로운 기법을 사용하였다. 상업용 시험장치를 이용하여 ASTM C666에 따라 제작된 $400{\times}350{\times}100mm$ 크기의 콘크리트 시편에 동결-융해 손상을 발생시켰다. 1사이클은 온도변화를 -14에서 $4^{\circ}C$로 하였고, $4{\sim}5$시간이 소요되었다. 매 5사이클마다 one-sided 응력파 속도측정기법에 기초하여 종파 및 표면파속도를 측정하였다. 동결-융해 손상이 증가함에 따라 종파 및 표면파속도의 변화가 있었고 이것은 동결-등채 피로 손상과정을 보다 유효하게 나타낸다는 것을 입증하였다. 또한 one-sided 기법에 의해 측정된 종파속도의 변화를 투과법을 이용하여 측정된 결과와 비교하였다.

  • PDF

동결융해 및 부착재료 변화에 따른 GFRP-구조물 경계면의 최대 부착강도 및 유효부착길이 평가 (Investigation of Maximum Strength and Effective Bonding Length at the Interface Between Structure and GFRP Material Under Freeze-thaw Cycles and Applied Different Bonding Materials)

  • 최현규;정우영;안미경
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.107-115
    • /
    • 2011
  • 본 연구는 부착재료의 변화 및 동결융해에 따른 FRP-콘크리트구조물 경계면의 거동을 조사하였다. 실험 시 고려된 연구변수로는 부착경계면의 부착강도, 경계면 유효부착길이 등을 조사하였다. 경계면 부착재료에 따른 거동변화 실험체의 경우 FRP-구조물 부착경계면에 사용되는 에폭시의 종류를 각각 3가지로 분류하며 FRP-콘크리트간 다양한 부착길이를 고려하여 시편을 제작하였으며 동결융해에 따른 경계면 거동조사의 경우 0 cycle에서 300cycle까지 계속적으로 증가되는 주기에 대하여 실험체들을 제작, 장기거동 부착실험을 수행하였다. 본 실험결과, 적용 부착재료의 종류에 따라 최대 유효부착길이는 5~7% 차이가 있었으며 동결융해 주기증가에 따른 최대부착하중 및 유효부착길이의 경우 초기에 나타난 급격한 거동변화 이후 상대적으로 불규칙한 변화를 장기적으로 나타내었다.

수분민감성 관련 소석회 및 박리방지제 첨가 투수성 가열 아스팔트 혼합물의 최적 함량 평가 (Evaluation of Optimum Contents of Hydrated-Lime and Anti-Freezing Agent for Low-Noise Porous Asphalt Mixture considering Moisture Resistance)

  • 김도완;이상염;문성호
    • 한국도로학회논문집
    • /
    • 제18권6호
    • /
    • pp.123-130
    • /
    • 2016
  • OBJECTIVES : The objective of this research is to determine the moisture resistance of the freeze-thaw process occurring in low-noise porous pavement using either hydrated-lime or anti-freezing agent. Various additives were applied to low-noise porous asphalt, which is actively paved in South Korea, to overcome its disadvantages. Moreover, the optimum contents of hydrated-lime and anti-freezing agent and behavior properties of low-noise porous asphalt layer are determined using dynamic moduli via the freeze-thaw test. METHODS : The low-noise porous asphalt mixtures were made using gyratory compacters to investigate its properties with either hydrated-lime or anti-freezing agent. To determine the dynamic moduli of each mixture, impact resonance test was conducted. The applied standard for the freeze-thaw test of asphalt mixture is ASTM D 6857. The freeze-thaw and impact resonance tests were performed twice at each stage. The behavior properties were defined using finite element method, which was performed using the dynamic modulus data obtained from the freeze-thaw test and resonance frequencies obtained from non-destructive impact test. RESULTS : The results show that the coherence and strength of the low-noise porous asphalt mixture decreased continuously with the increase in the temperature of the mixture. The dynamic modulus of the normal low-noise porous asphalt mixture dramatically decreased after one cycle of freezing and thawing stages, which is more than that of other mixtures containing additives. The damage rate was higher when the freeze-thaw test was repeated. CONCLUSIONS : From the root mean squared error (RMSE) and mean percentage error (MPE) analyses, the addition rates of 1.5% hydrated-lime and 0.5% anti-freezing agent resulted in the strongest mixture having the highest moisture resistance compared to other specimens with each additive in 1 cycle freeze-thaw test. Moreover, the freeze-thaw resistance significantly improved when a hydrated-lime content of 0.5% was applied for the two cycles of the freeze-thaw test. Hence, the optimum contents of both hydrated-lime and anti-freezing agent are 0.5%.

A Numerical Model for the Freeze-Thaw Damages in Concrete Structures

  • Cho Tae-Jun
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.857-868
    • /
    • 2005
  • This paper deals with the accumulated damage in concrete structures due to the cyclic freeze-thaw as an environmental load. The cyclic ice body nucleation and growth processes in porous systems are affected by the thermo-physical and mass transport properties, and gradients of temperature and chemical potentials. Furthermore, the diffusivity of deicing chemicals shows significantly higher value under cyclic freeze-thaw conditions. Consequently, the disintegration of concrete structures is aggravated at marine environments, higher altitudes, and northern areas. However, the properties of cyclic freeze-thaw with crack growth and diffusion of chloride ion effects are hard to be identified in tests, and there has been no analytic model for the combined degradations. The main objective is to determine the driving force and evaluate the reduced strength and stiffness by freeze-thaw. For the development of computational model of those coupled deterioration, micro-pore structure characterization, pore pressure based on the thermodynamic equilibrium, time and temperature dependent super-cooling with or without deicing salts, nonlinear-fracture constitutive relation for the evaluation of internal damage, and the effect of entrained air pores (EA) has been modeled numerically. As a result, the amount of ice volume with temperature dependent surface tensions, freezing pressure and resulting deformations, and cycle and temperature dependent pore volume has been calculated and compared with available test results. The developed computational program can be combined with DuCOM, which can calculate the early aged strength, heat of hydration, micro-pore volume, shrinkage, transportation of free water in concrete. Therefore, the developed model can be applied to evaluate those various practical degradation cases as well.

Effect of Multiple Freeze-Thaw Cycles on Lipid Degradation and Lipid Oxidation of Grass Carp Surimi Containing Different Amounts of Pork Back Fat

  • Shang, Xiaolan;Du, Juan;Zhao, Yuhan;Tian, Jiajia;Jiang, Shuhui
    • 한국축산식품학회지
    • /
    • 제41권6호
    • /
    • pp.923-935
    • /
    • 2021
  • Fresh grass carp was used to produce surimi samples that were supplemented with 50 g/kg, 100 g/kg, or 150 g/kg pork back fat. The lipid composition, lipase activity, lipid oxidation index, and lipoxygenase activity of samples subjected to repeated freezethaw process were determined to assess the effects of the added fat on lipolysis and lipid oxidation of grass carp surimi. Freeze-thaw treatment increased free fatty acid content, mainly due to the decomposition of phospholipids and some neutral lipids by lipase. With repeated freeze-thaw treatment, the levels of free fatty acids and phospholipids were correlated with the lipid oxidation indexes and lipoxygenase activity, indicating that lipid degradation can promote lipid oxidation. In the same freeze-thaw cycle, surimi products with high fat content are more vulnerable to oxidative damage, neutral lipids are the main source of free fatty acids in the early stage of freeze-thaw, and phospholipids are the main source of free fatty acids in the late stage.

Engineering Geological Characteristics of Freeze-Thaw Weathered Gneiss in the Wonju Area, Korea

  • Um, Jeong-Gi;Woo, Ik;Park, Hyuck Jin
    • 지질공학
    • /
    • 제24권2호
    • /
    • pp.161-169
    • /
    • 2014
  • We present the results of an experimental physical weathering study that focuses on fresh and slightly weathered gneiss samples from the Wonju area of Korea. The study investigated changes in the physico-mechanical properties of these samples during accelerated laboratory-based weathering, including analyses of microfracture formation. The deteriorated samples used in the study were subjected to 100-150 freeze-thaw cycles, with index properties and microfracture geometries measured between each cycle. Each complete freeze-thaw cycle lasted 24 hours, and consisted of 2 hours of saturation in a vacuum chamber, 8 hours of freezing at $-21^{\circ}C{\pm}1^{\circ}C$, and 14 hours of thawing at room temperature. Specific gravity and seismic velocity values were negatively correlated with the number of freeze-thaw cycles, whereas absorption values tended to increase. The amount of deterioration of the rock samples was dependent on the degree of weathering of the rock prior to the start of the analysis. Absorption, specific gravity, and seismic velocity values can be used to infer the amount of physical weathering experienced by a gneiss in the study area. The sizes and density of microfracture in the rock specimens varied with the number of freeze-thaw cycles. We found that box fractal dimensions can be used to quantify the formation and propagation of microfracture in the samples. In addition, these box fractal dimensions can be used as a weathering index for the mid-and long-term prediction of rock weathering. The present results indicate that accelerated-weathering analysis can provide a detailed overview of the weathering characteristics of deteriorated rocks.

남극 테라노바 만 편마암의 동결-융해에 따른 지반공학적 특성 변화 (Variations of Geotechnical Characteristics Following Freeze-Thaw of Terra Nova Bay Rocks, Antarctica)

  • 김영석;김기주;장현식;장보안
    • 대한토목학회논문집
    • /
    • 제33권4호
    • /
    • pp.1499-1508
    • /
    • 2013
  • 남극 암석의 동결-융해 풍화현상에 관한 연구를 위하여 테라노바 만 지역의 편마암을 대상으로 풍화등급에 따라 약한풍화(SW) 및 보통풍화(MW)로 분류하여 암석의 공학적인 특성 변화를 실험하였다. 동결-융해시험은 $-20{\pm}2^{\circ}C{\sim}20{\pm}2^{\circ}C$의 온도 조건에서 수행되었으며, 암석 시험편은 진공챔버에서 포화된 상태에서 5시간 동결과 5시간 융해 과정을 1 cycle의 동결-융해로 설정하였다. 본 논문에서는 전체 200 cycle의 동결-융해 과정을 진행하면서 20 cycle 마다 공극률, 흡수율, 초음파 속도 및 쇼어경도를 측정하였으며, 50 cycle 마다 일축압축시험을 수행하였다. SW 등급의 편마암은 동결-융해 1 cycle 마다 0.07 MPa 정도 일축압축강도가 감소하였으며, MW 등급의 암석은 0.2 MPa 정도 일축압축 강도가 감소하였다. 동결-융해가 200 cycle 진행되는 동안 SW 등급 암석의 흡수율은 0.23%에서 0.39%로 증가하였으며, P파 속도는 4,054 m/s에서 3,227 m/s로, S파 속도는 2,519 m/s에서 2,079 m/s로 감소하였다. 이와 유사하게 MW 등급 암석의 흡수율은 0.65%에서 1.6%로 증가하였으며, P파 속도는 3,207 m/s에서 2,133 m/s로, S파 속도는 2,028 m/s에서 1,357 m/s로 감소하였다. 동결-융해시험 결과, 남극 테라노바 만 지역의 SW 등급 편마암은 동결-융해가 200~300 cycle 반복될 경우 MW 등급 암석에 가깝게 풍화되는 것으로 밝혀졌다.

염해 및 동결융해의 복합열화 작용에 의한 부식촉진시험에 관한 연구 (A Study on Accelerated Corrosion Test by Combined Deteriorating Action of Salt Damage and Freeze-Thaw)

  • 박상순;소병탁
    • Corrosion Science and Technology
    • /
    • 제15권1호
    • /
    • pp.18-27
    • /
    • 2016
  • In this study, the accelerated corrosion test by combined deteriorating action of salt damage and freeze-thaw was investigated. freeze-thaw cycle is one method for corrosion testing; corrosion initiation time was measured in four types of concrete samples, i.e., two samples mixed with fly ash (FA) and blast furnace slag (BS), and the other two samples having two water/cement ratio (W/C = 0.6, 0.35) without admixture (OPC60 and OPC35). The corrosion of rebar embedded in concrete occurred most quickly at the $30^{th}$ freeze-thaw cycle. Moreover, a corrosion monitoring method with a half-cell potential measurement and relative dynamic elastic modulus derived from resonant frequency measures was conducted simultaneously. The results indicated that the corrosion of rebar occurred when the relative dynamic elastic modulus was less than 60%. Therefore, dynamic elastic modulus can be used to detect corrosion of steel bar. The results of the accelerated corrosion test exhibited significant difference according to corrosion periods combined with each test condition. Consequently, the OPC60 showed the lowest corrosion resistance among the samples.