• 제목/요약/키워드: free water

검색결과 3,595건 처리시간 0.031초

Free Radical Scavenging Activity of Enzymatic Hydrolyzates of Hot Water Extract from the Shell of Reeve's Turtle (Chinemys reevesii)

  • Je, Jae-Young;Kim, Eun-Kyung;Park, Pyo-Jam;Kang, Mi-Kyung;Ahn, Chang-Bum
    • Fisheries and Aquatic Sciences
    • /
    • 제11권2호
    • /
    • pp.71-75
    • /
    • 2008
  • The shell of Reeve's turtle has been used as a traditional folk medicine in Korea. We produced a hot water extract from Reeve's turtle shell according to the traditional medical practice. To release bioactive peptides, the hot water extract was enzymatically hydrolyzed with various proteases, and the free radical scavenging activity of the hydrolysate was investigated against 1,1-diphenyl-2-picryl-hydrazyl (DPPH), hydroxyl and peroxyl radicals. The free radical scavenging activity of the enzymatic hydrolysates varied from 1 to 79% depending on the enzymes, free radical species, and concentration. The $EC_{50}$ values demonstrated that the enzymatic hydrolysates of hot water extract from the shell of Reeve's turtle are potential antioxidants.

An improved Rankine source panel method for three dimensional water wave problems

  • Feng, Aichun;You, Yunxiang;Cai, Huayang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권1호
    • /
    • pp.70-81
    • /
    • 2019
  • An improved three dimensional Rankine source method is developed to solve numerically water wave problems in time domain. The free surface and body surface are both represented by continuous panels rather than a discretization by isolated points. The integral of Rankine source 1/r on free surface panel is calculated analytically instead of numerical approximation. Due to the exact algorithm of Rankine source integral applied on the free surface and body surface, a space increment free surface source distribution method is developed and much smaller amount of source panels are required to cover the fluid domain surface than other numerical approximation methods. The proposed method shows a higher accuracy and efficiency compared to other numerical methods for various water wave problems.

경제성 평가를 이용한 프리쿨링시스템의 국내 적용성 연구 (A Study on Application of the Free Cooling System with Dry Cooler Using Economic Evaluation)

  • 윤정인;손창효;김희민;김영민
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.50-55
    • /
    • 2015
  • Recently, because of the deterioration of the nuclear generating station and increase of the cooler and heater, energy problem is increasing. To save the energy, the free cooling system is developed. The free cooling system is that cool the water to use cooled air in winter and is used in industrial process or data center. Yoon check the energy of free cooling system with dry cooler in korea. In this study, the value of the free cooling system with dry cooler is confirmed through using the NPV that is economic evaluation. when temperature degree of the cooled water is 10, in Chuncheon and Seoul the value is the most high. When temperature degree of the cooled water is 20, in Ulsan the value is the most high. As the result, because the using the temperature degree of the cooled water is high in the industrial process, the free cooling system is advantageous in korea.

PREDICTION OF FREE SURFACE FLOW ON CONTAINMENT FLOOR USING A SHALLOW WATER EQUATION SOLVER

  • Bang, Young-Seok;Lee, Gil-Soo;Huh, Byung-Gil;Oh, Deog-Yeon;Woo, Sweng-Woong
    • Nuclear Engineering and Technology
    • /
    • 제41권8호
    • /
    • pp.1045-1052
    • /
    • 2009
  • A calculation model is developed to predict the transient free surface flow on the containment floor following a loss-of-coolant accident (LOCA) of pressurized water reactors (PWR) for the use of debris transport evaluation. The model solves the two-dimensional Shallow Water Equation (SWE) using a finite volume method (FVM) with unstructured triangular meshes. The numerical scheme is based on a fully explicit predictor-corrector method to achieve a fast-running capability and numerical accuracy. The Harten-Lax-van Leer (HLL) scheme is used to reserve a shock-capturing capability in determining the convective flux term at the cell interface where the dry-to-wet changing proceeds. An experiment simulating a sudden break of a water reservoir with L-shape open channel is calculated for validation of the present model. It is shown that the present model agrees well with the experiment data, thus it can be justified for the free surface flow with accuracy. From the calculation of flow field over the simplified containment floor of APR1400, the important phenomena of free surface flow including propagations and interactions of waves generated by local water level distribution and reflection with a solid wall are found and the transient flow rates entering the Holdup Volume Tank (HVT) are obtained within a practical computational resource.

On-line Conversion Estimation for Solvent-free Enzymatic Esterification System with Water Activity Control

  • Lee, Sun-Bok;Keehoon Won
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제7권2호
    • /
    • pp.76-84
    • /
    • 2002
  • On-line conversion estimation of enzymatic esterification reactions in solvent-free media was investigated. In principle, conversion to ester can be determined from the amount of water produced by the reaction, because water is formed as a by-product in a stoichiometric manner. In this study, we estimated the water production rate only from some measurements of relative humidity and water balances without using any analytical methods. In order to test the performance of the on-line conversion estimation, the lipase-catalyzed esterification of n-capric acid and n-decal alcohol in solvent-free media was performed whilst controlling water activity at various values. The reaction conversions estimated on-line were similar to those determined by offline gas chromatographic analysis. However, when the water activity was controlled at higher values, discrepancies between the estimated conversion values and the measured values became significant. The deviation was found to be due to the inaccurate measurement of the water content in the reaction medium during the initial stages of the reaction. Using a digital filter, we were able to improve the accuracy of the on-line conversion estimation method considerably. Despite the simplicity of this method, the on-line estimated conversions were in good agreement with the off-line measured values.

Antioxidant activity and total polyphenolics of Shiitake Mushroom extracts(Lentinus edodes)

  • Lee, Hee-Hwan;Jang, Jae-Soon;Hong, Eock-Kee
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVII)
    • /
    • pp.854-858
    • /
    • 2005
  • Methanol and water crude extracts, crude polysaccharides and crude polysaccharides-free of water crude extracts from Shiitake mush-room (Lentinus edodes) were investigated for their antioxidant capacity in total polyphenolics and 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activity. Total polyphenolics in the crude polysaccharides-free of water crude extracts were higher than that of the other ones. And crude polysaccharides-free of water crude extracts and water crude extracts show high on DPPH free radical scavenging activity. Positive correlations were found between total polyphenolics and their antioxidant activity.

  • PDF

농업유역 비점원오염 저감을 위한 자유수면형 인공습지 설계인자 평가 (Assessment of Free Water Surface Constructed Wetland Design Parameters for the Reduction of Agricultural Nonpoint Source Pollution)

  • 장정렬;권순국;최선화
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.637-642
    • /
    • 2005
  • The objective of this study is to evaluate design parameters of free water surface constructed wetland for the reduction of agricultural nonpoint source pollution. From literature review, the key design parameters were selected as influent concentration, influent water volume, hydraulic retention time and wetland system arrangement. The design value for each parameter was established after pilot study. Full-scale constructed wetland on the basis of the designed values was constructed to evaluate those reasonableness. The results of this study showed that the designed values for free water surface constructed wetland were appropriate for the reduction of agricultural nonpoint source pollution.

  • PDF

전기분해에 의한 잔류염소 생성 예측 모델 개발 (Model development for chlorine generation using electrolysis)

  • 손진식;이선재;신초롱
    • 상하수도학회지
    • /
    • 제23권3호
    • /
    • pp.331-337
    • /
    • 2009
  • Electrolysis produces hypochlorous acid by using a small quantity of NaCl as electrolyte. This process maximizes the stabilization of drinking water through the control of chlorine residual concentration. This study investigated free chlorine generation by an electrolytic method using $Ti/IrO_2$ and stainless steel. The generation of free chlorine was increased with increasing hydraulic retention time, voltage, chlorine ion concentration and the number of electrodes. However, the change of pH did not affect the generation of free chlorine. There was no significant difference on the behavior of chlorine concentration between electrolytic method and NaOCl injection. In this study, the concentration of free chlorine predicted model based on power functional model was developed various under conditions. Electrolysis free chlorine generation model can be effective tool in the estimation of free chlorine generation.

The deformation of a free surface due to the impact of a water droplet

  • Kwon, Sun-Hong;Park, Chang-Woo;Lee, Seung-Hun;Shin, Jae-Young;Choi, Young-Myung;Chung, Jang-Young;Isshiki, Hiroshi
    • International Journal of Ocean System Engineering
    • /
    • 제1권1호
    • /
    • pp.28-31
    • /
    • 2011
  • An attempt was made to compute the free surface deformation due to the impact of a water droplet. The Cauchy Poisson, i.e. the initial value problem, was solved with the kinematic and dynamic free surface boundary conditions linearized. The zero order Hankel transformation and Laplace transform were applied to the related equations. The initial condition for the free surface profile was derived from a captured video image. The effect of the surface tension was not significant with the water mass used in this investigation. The computed and observed free surface deformations were compared.

급배수시스템에서 잔류염소 농도 균등화를 위한 재염소 처리 (Rechlorination for residual chlorine concentration equalization in distribution system)

  • 김진근;한지안
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.91-101
    • /
    • 2014
  • Three water treatment plants(WTPs) in Jeju island whose source water have different characteristics from those of the mainland of Korea were investigated. Coefficients of bulk water decay($k_b$) of free chlorine at $5^{\circ}C$ for ES, GJ, NW WTPs were $-0.003hr^{-1}$, $-0.002hr^{-1}$ and $-0.001hr^{-1}$ respectively based on bottle tests. To simulate the free chlorine variations in the distribution system using EPANET, ES WTP was chosen. Free chlorine concentrations of several sites were less than the drinking water quality standards(i.e., 0.1 mg/L); E5(0.03 mg/L), E6(0.02 mg/L), W21(0.02 mg/L) and W25(0.03 mg/L). To maintain more than 0.1 mg/L of free chlorine in the distribution system, at least 1.9 mg/L of chlorine was needed at the WTP, which suggested rechlorination was needed to supply palatable tap water to customers. Two sites, one that diverged into E5 and E6 in the east-line and another located before E21 in the west-line were selected for the appropriate rechlorination locations. The recommended rechlorination dosages were 0.42 mg/L for the east and 0.27 mg/L for the west. The simulated results indicated that the free chlorine could be reduced to 0.4 mg/L at the WTP with rechlorination, and taps with excessive free chlorine could be more stabilized(i.e., 0.1~0.4 mg/L).