• Title/Summary/Keyword: free length

Search Result 1,347, Processing Time 0.025 seconds

Dynamic response of free-end rod with consideration of wave frequency

  • Kim, Sang Yeob;Lee, Jong-Sub;Tutumluer, Erol;Byun, Yong-Hoon
    • Geomechanics and Engineering
    • /
    • v.28 no.1
    • /
    • pp.25-33
    • /
    • 2022
  • The energy transferred on drill rods by dynamic impact mainly determines the penetration depth for in-situ tests. In this study, the dynamic response and transferred energy of drill rods are determined from the frequency of the stress waves. AW-type drill rods of lengths 1 to 3 m are prepared, and strain gauges and an accelerometer are installed at the head and tip of the connected rods. The drill rods are hung on strings, allowing free vibration, and then impacted by a pendulum hammer with fixed potential energy. Increasing the rod length L increases the wave roundtrip time (2L/c, where c is the wave velocity), and hence the transferred energy at the rod head. At the rod tip, the first velocity peak is higher than the first force peak because a large and tensile stress wave is reflected, and the transferred energy converges to zero. The resonant frequency increases with rod length in the waveforms measured by the strain gauges, and fluctuates in the waveforms measured by the accelerometer. In addition, the dynamic response and transferred energy are perturbed when the cutoff frequency is lower than 2 kHz. This study implies that the resonant frequency should be considered for the interpretation of transferred energy on drill rods.

Determination of Dynamic Free Span Length for Subsea Pipelines with General Boundary Conditions (일반화된 경계조건을 갖는 해저파이프라인의 동적 자유경간 결정 방법)

  • 박한일
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.4
    • /
    • pp.290-295
    • /
    • 2001
  • Subsets pipelines are exposed to several potential risks of damage due to corrosion, soil instability, anchor impact and other hazards. One of the main risk factors for the safety of a subsea pipeline is its free spanning. This paper examines the safety of subsea pipelines with free span under axial compressive load. The variation of allowable lengths of dynamic free span is examined for generalized boundary conditions. The free span is modelled as a beam with an elastic foundations and the boundary condition is replaced by linear and rotational springs at each end. A dynamic free span curve is obtained with a function of non-dimensional parameters and can be used usefully for the design of subsea pipelines with a free span. A case study is carried out to introduce the application method of the curve.

  • PDF

The Distribution of Boundaty Stresses around the Lightening Hole in a Triangular Bracket. (Bracket의 Lightening Hole 주변(周邊)에서의 응력분포(應力分布))

  • Hyo-Chul,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.3 no.1
    • /
    • pp.11-18
    • /
    • 1966
  • In a polarized light field, triangular plate bracket specimen of CR-39 with lightening hole were subjected to tension. The variables of the models used in the experiment were taken in the range of length-depth $ratio=0.583{\sim}1.715$, eccentricity of lightening hole from the geometrical center of $bracket=-1/4"{\sim}+1/4"$, and the lightening hole $diameter=1/2"{\sim}2"$. The isoclinics were drawn and from those the stress trajectories were constructed. Then the distributions of boundary stress around the lightening holes were determined from the isochromatic fringe pattern. The conclusions reached in this investigation are as follows: 1. Maximum stresses of the hole boundary are gradually increased when the diameter of the lightning hole increase. 2. Maximum stresses of the lightning hole boundary are decreased gradually when the eccentricity of the lightning hole from the geometrical center of the bracket to the farther side from the free end. 3. If the minimum distances from the free end of the brackets to the lightening hole boundaries are equal, the variation of the maximum stresses are in a small range for the change of lightening hole diameter and its location. 4. When the length-depth ratios are smaller than 0.8, the maximum stresses increase steeply. In the range of $0.8{\sim}1.2$ maximum stresses increase gradually and thereafter increase rapidly when the length-depth ratio of the bracket increase for the same diameter of a lightening hole.

  • PDF

Four unrecorded species of free-living nematodes from the sublittoral zone in the East Sea, Korea

  • Jung-Ho Hong;Kichoon Kim;Seunghan Lee;Kanghyun Lee
    • Journal of Species Research
    • /
    • v.13 no.2
    • /
    • pp.147-158
    • /
    • 2024
  • Four species of the free-living nematodes were collected from marine sediments in the sublittoral zone in the East Sea, Korea and were identified, described, and illustrated. Paranticoma tricerviseta Zhang, 2005, originally described from the Bohai Sea, China, is recorded for the first time in the East Sea, Korea; only in body length and thickness (1902-2282 ㎛ compared to 2472-3300 ㎛, 50-62 ㎛ compared to 57-82 ㎛, respectively). Specimens of Parodontophora marina Zhang, 1991, from East Sea, Korea largely agrees with the original description of Zhang (1991) of nematodes from the Bohai Sea, except for differences in body length and thickness (1190-1345 ㎛ compared to 1235-1408 ㎛, 40-44 ㎛ compared to 42-72 ㎛). Terschellingia longicaudata de Man, 1907 is reported for the first time in Korea, but was previously considered a cosmopolitan species of nematodes with a widespread distribution from the North Sea, Belgium to the Exclusive Economic Zone of New Zealand; it differs from the original description in body thickness(30-38 ㎛ vs. 40-62 ㎛). Vasostoma brevispicula Huang & Wu, 2011, originally described from the subtidal muddy sediment in the Yellow Sea, China, is newly reported in Korea; apart from a few minor morphological differences, body length and thickness (2009-2425 ㎛ vs. 2119-2906 ㎛, 41-48 ㎛ vs. 37-58 ㎛). The present study on unrecorded species improves our understanding of nematode species diversity in Korean waters.

The Regional Anatomy of Perforating artery and Pedicle for the Anterolateral Thigh Free Flap in the Korean (한국사람의 앞가쪽넙다리유리피판술에서의 관통동맥과 피판줄기에 대한 국소 해부)

  • Song, Hyun Suk;Park, Myong Chul
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.20-27
    • /
    • 2008
  • Purpose: The anterolateral thigh flap has many advantages over other conventional free flaps. But the anterolateral thigh flap has yet to enter widespread use because perforating arteries exhibit a wide range of anatomic variations and are difficult to dissect when small. The aim of this study is to identify the vascular variability of perforating arteries and pedicle in the anterolateral thigh free flap. Methods: We studied 12 cadavers and dissected 23 thighs. An anterolateral thigh flap ($12{\times}12cm$) was designed and centered at the midpoint of the line drawn from anterior superior iliac spine to the superolateral border of the patella. After we identifed the perforating arteries we dissected up to their origin from lateral circumflex femoral artery along descending branch of lateral circumflex femoral artery. We then investigated the number and the position of perforating arteries, length and diameter of vascular pedicle and pattern of lateral circumflex femoral arterial system. Results: On average $2.3{\pm}1.1$ perforating arteries per thigh were identified. The musculocutaneous perforators were 63.1%. In those perforators five perforators were arose from transverse branch of lateral circumflex femoral artery and two were arose from rectus femoral artery. Most of the perforators were near the intermuscular septum between rectus femoris muscle and vastus lateralis muscle. The length and diameter of pedicle were $11.9{\pm}3.5cm$ and $3.1{\pm}0.8mm$ on average. Conclusion: This study will be helpful for the success in anterolateral thigh free flap.

The effect on the formation of keratinized attached gingiva using free gingival graft with strip technique (Strip 형 유리치은 이식술이 부착지은 형성에 미치는 영향)

  • Lee, Dong-Yeol;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.305-318
    • /
    • 2006
  • This study was performed to evaluate the effect on the formation of keratinized attached gingiva when free gingival graft with strip technique was used. After the partial thickness flap was prepared, it was positioned apically more than 7mm using mucoperiosteal suture. At the donor site, strip was achieved with 2mm width, less than 1mm thickness, (mesiodistal teeth length + 6)$^{\ast}$2 mm length. Then, it was divided into 2 same pieces and located at the recipient bed apico-coronally with more or less 3mm interval. Follow-up check was made at 1,2,4,8,12 weeks after the operation. The results of this study were as follows : 1. The inter-strip space was mostly filled with keratinized attached gingiva. 2. The contraction of the graft was nigligible, and 92% of planned area was filled with keratinized attached gingiva. 3. The inconvenience of the patients at donor site was minimal. 4. The width of the strip was widened. In conclusion, free gingival graft using strip technique is useful to achieve the keratinized attached gingiva maximally with free gingival graft minimally and to minimize the inconvenience of donor palatal site of the patients.

Hand Reconstruction Using Anterolateral Thigh Free Flap by Terminal Perforator-to-Digital Artery Anastomosis: Retrospective Analysis

  • Jin Soo Kim;Ho Hyung Lee;Sung Hoon Koh;Dong Chul Lee;Si Young Roh;Kyung Jin Lee
    • Archives of Plastic Surgery
    • /
    • v.51 no.1
    • /
    • pp.87-93
    • /
    • 2024
  • This study aimed to analyze cases of anterolateral thigh (ALT) free flap used for hand reconstruction with terminal perforator-to-digital artery anastomosis. Patients who underwent ALT free flap placement with terminal perforator-to-digital artery anastomosis for hand reconstruction between January 2011 and August 2021 were included. The number, length, and diameter of the perforators and veins, flap size, and operative time were investigated through a retrospective review of charts and photographs. The occurrences of arterial thrombosis, venous thrombosis, arterial spasm, and flap necrosis were analyzed. In total, 50 patients were included in this study. The mean diameter and length of the perforators were 0.68 mm and 3.25 cm, respectively, and the mean number of veins anastomosed was 1.88, with a mean diameter of 0.54 mm. Complications included four cases of arterial thrombosis, one case of venous thrombosis, seven cases of partial necrosis, and one case of total flap failure. Regression analysis showed that a longer perforator was associated with arterial thrombosis whereas larger flap size and number of anastomosed veins were associated with partial necrosis (p < 0.05). The terminal perforator-to-digital artery anastomosis offers advantages in using compact free flaps with short pedicle lengths to cover small hand defects.

Design and Strength Evaluation of an Anodically Bonded Pressurized Cavity Array for Wafer-Level MEMS Packaging (기판단위 밀봉 패키징을 위한 내압 동공열의 설계 및 강도 평가)

  • Gang, Tae-Gu;Jo, Yeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.1
    • /
    • pp.11-15
    • /
    • 2001
  • We present the design and strength evaluation of an anodically bonded pressurized cavity array, based on the energy release rate measured from the anodically bonded plates of two dissimilar materials. From a theoretical analysis, a simple fracture mechanics model of the pressurized cavity array has been developed. The energy release rate (ERR) of the bonded cavity with an infinite bonding length has been derived in terms of cavity pressure, cavity size, bonding length, plate size and material properties. The ERR with a finite bonding length has been evaluated from the finite element analysis performed for varying cavity and plate sizes. It is found that, for an inter-cavity bonding length greater than the half of the cavity length, the bonding strength of cavity array approaches to that of the infinite plate. For a shorter bonding length, however, the bonding strength of the cavity array is monotonically decreased with the ratio of the bonding length to the cavity length. The critical ERR of 6.21J/㎡ has been measured from anodically bonded silicon-glass plates. A set of critical pressure curves has been generated for varying cavity array sizes, and a design method of the pressurized cavity array has been developed for the failure-free wafer-level packaging of MEMS devices.

Growth Characteristics and Yield of Sweet Potato Cultivars between Virus-free and Farmer's Slips in Late Season Cultivation (고구마 바이러스 무병묘와 농가묘의 만기재배에서 품종 간 생육 및 수량특성)

  • Yoo, Kyoung-Ran;Lee, Seung-Yeob
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.1
    • /
    • pp.43-49
    • /
    • 2013
  • This work was conducted to obtain some information about stable production of high quality seed-tubers in the late season cultivation of virus-free sweet potato [Ipomoea batatas (L.) Lam.]. Growth characteristics and storage root yield between virus-free and farmer's slips in 9 cultivars were investigated using black-film vinyl mulching cultivation with $75{\times}25cm$ planting density on July 10. At 30 days after planting, vine length, vine diameter, number of node, and number of branch in virus-free slips were significantly increased than those in farmer's slips. The vine growth was significantly different among cultivars, and vine elongation was excellent in 'Kogeonmi', 'Shincheonmi', 'Shinhwangmi', 'Shinyulmi', and 'Yeonhwangmi' compared to the other cultivars. At 110 days after planting, vine length, vine diameter, number of node, number of branch, and fresh weight were significantly different among cultivars, but no significant differences between virus-free and farmer's slips were seen except number of node. Total yield in virus-free slips was increased by 12-49% among cultivars than that in farmer's slips. The mean yields between virus-free and farmer's slips were 1,625 kg/10a and 1,230 kg/10a, respectively, and it was significantly different between virus-free and farmer's slips. Percentage of marketable storage root in virus-free slips was 65.6%, and it was significantly higher than 57.8% in farmer's slips. Marketable yields ($40g{\leq}$) between virus-free and farmer's slips were 1,067 kg/10a and 710 kg/10a, respectively. Marketable yield in 'Shincheonmi', 'Shinyulmi' and 'Shinzami' was more than 1,300 kg/10a, and these cultivars showed to be highly adaptable for the late-season cultivation among 9 tested cultivars.

Surface and size dependent effects on static, buckling, and vibration of micro composite beam under thermo-magnetic fields based on strain gradient theory

  • Mohammadimehr, Mehdi;Mehrabi, Mojtaba;Hadizadeh, Hasan;Hadizadeh, Hossein
    • Steel and Composite Structures
    • /
    • v.26 no.4
    • /
    • pp.513-531
    • /
    • 2018
  • In this article, static, buckling and free vibration analyses of a sinusoidal micro composite beam reinforced by single-walled carbon nanotubes (SWCNTs) with considering temperature-dependent material properties embedded in an elastic medium in the presence of magnetic field under transverse uniform load are presented. This system is used at micro or sub micro scales to enhance the stiffness of micro composite structures such as bar, beam, plate and shell. In the present work, the size dependent effects based on surface stress effect and modified strain gradient theory (MSGT) are considered. The generalized rule of mixture is employed to predict temperature-dependent mechanical and thermal properties of micro composite beam. Then, the governing equations of motions are derived using Hamilton's principle and energy method. Numerical results are presented to investigate the influences of material length scale parameters, elastic foundation, composite fiber angle, magnetic intensity, temperature changes and carbon nanotubes volume fraction on the bending, buckling and free vibration behaviors of micro composite beam. There is a good agreement between the obtained results by this research and the literature results. The obtained results of this study demonstrate that the magnetic intensity, temperature changes, and two parameters elastic foundations have important effects on micro composite stiffness, while the magnetic field has greater effects on the bending, buckling and free vibration responses of micro composite beams. Moreover, it is shown that the effects of surface layers are important, and observed that the changes of carbon nanotubes volume fraction, beam length-to-thickness ratio and material length scale parameter have noticeable effects on the maximum deflection, critical buckling load and natural frequencies of micro composite beams.